| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC NERIPAL PAJHOTA DISTT SIRMAUR H P | SIRMAUR | HIMACHAL PRADESH | L1 | Accepted-AOC ok | |
| 2 | L2₹5.7 L+₹17,020.24 (3.10%)Rejected-Finance 284 VEENA NAGAR CAMP DISTT JAGADHARI YAMUNA NAGAR 135001 HARYANA | YAMUNANAGAR | HARYANA | 135001 | L2 | Rejected-Finance ok | |
| 3 | Rejected-Technical | - | Rejected-Technical ok | |
| 4 | Rejected-Technical 1386 4 GULLIANA NEW DELHI CENTRAL DELHI 110006 | NEW DELHI | CENTRAL DELHI | DELHI | 110006 | - | Rejected-Technical ok |
Tender Value
Refer Docs
EMD Value
₹5,490
Closing Date
2 Nov 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Resident Engineer
Larji Power House Division HPSEBL Thalout
Tender for repair and refurbishment of various items and their successful testing and commissioning at 3x1.5 MW Thirot Powerhouse under Resident Engineer, Larji Powerhouse Division, HPSEBL Thalout.
2026_HPSEB_146357_1
HPSEBL/RELPHD/DB-10/ 2026-27-28
Open Tender
Repair and Maintenance Works
Percentage
30 days
3x1.5MW Thirot Power house
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹5,490
16 Nov 2026
24 Oct 2026
2 Nov 2026
24 Oct 2026
2 Nov 2026
24 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repair and Refurbishment of Nozzle Tip.
Scope of work :- The work shall comprise comprehensive inspection, repair, refurbishment and precision machining of the existing hydro turbine Nozzle Tip to restore its original design profile, dimensional accuracy, surface integrity and functional performance in accordance with the approved OEM drawings and technical requirements as per the Engineer-InCharge and also include:
• Initial visual inspection and dimensional assessment to identify erosion, cavitation, corrosion, pitting, cracks, wear and material loss.
• Cleaning and preparation of damaged surfaces, including removal of defective material wherever required and technically permissible.
• Restoration of worn or damaged areas through an approved repair methodology, including weld build-up or material deposition, wherever necessary and suitable for the parent material.
• Precision machining and profile restoration of the nozzle tip, including the internal water passage, nozzle exit profile, seating surfaces and mounting interfaces, as applicable.
• Restoration of critical dimensions, concentricity, geometrical accuracy and surface finish in accordance with the approved OEM drawings or purchaser-approved dimensional requirements.
• Non-destructive testing (NDT), including Liquid Penetrant Testing (LPT/DPT) and other applicable examination methods, to verify the integrity of repaired areas.
• Final dimensional inspection, surface finish verification and preparation of inspection reports documenting actual measurements and conformity with specified acceptance criteria.
Submission of a comprehensive repair and inspection report, including details of repair methodology, NDT results and final dimensional inspection records and successful testing and commissioning at 3x1.5 MW Thirot Powerhouse under the supervision of contrctor complete job in all respect as per the direction and entire satisfaction of Engineer-in-Charge | 4 | Job | 57,220 | ₹2,28,880 |
| 2 | Repair and Refurbishment of Deflector.
Scope of work :- The work shall comprise comprehensive inspection, repair, refurbishment, profile restoration and precision machining of the existing Hydro Turbine Deflector to restore its original design geometry, dimensional accuracy, structural integrity and functional performance in accordance with approved OEM drawings and technical specifications as per the Engineer-In-Charge and also include :-
1 Initial Inspection and Condition Assessment: Detailed visual and dimensional inspection to identify erosion, cavitation, corrosion, pitting, cracking, material loss, deformation and wear on the deflecting surface and associated mounting interfaces.
2 Cleaning and Surface Preparation: Thorough cleaning and preparation of the component, including removal of deposits, corrosion products and defective material wherever required and technically permissible.
3 Repair and Material Restoration: Restoration of worn or damaged areas using an approved repair methodology, including weld build-up or material deposition, wherever necessary and compatible with the parent material.
4. Profile Restoration and Precision Machining: Restoration of the original deflector contour, jet-deflecting surface, edge geometry and critical functional dimensions through suitable machining and finishing operations, as applicable.
5. Mounting and Operating Interface Restoration: Inspection and refurbishment of pivot holes, bush seating areas, mounting faces, linkage interfaces and other associated components, wherever applicable, to ensure correct alignment, fitment and operating clearances.
6. Dimensional and Geometrical Verification: Verification of critical dimensions, profile accuracy, alignment, clearances and geometrical tolerances in accordance with approved OEM drawings or purchaserapproved dimensional requirements.
7. Surface Finishing: Final finishing of the deflecting surface to achieve the specified surface quality and profile continuity, ensuring the absence of unacceptable projections, irregularities and machining defects that could adversely affect jet-deflection performance.
8. Non-Destructive Testing (NDT): Liquid Penetrant Testing (LPT/DPT) and other applicable NDT examinations shall be performed on repaired areas, wherever required, in accordance with approved procedures and applicable acceptance criteria.
9. Functional Inspection: Verification of fitment compatibility, alignment and freedom of movement throughout the specified operating travel, wherever the associated operating arrangement is available for inspection.
10. Final Inspection and Documentation: Comprehensive final dimensional inspection and submission of inspection reports, NDT reports, repair records and applicable quality assurance documentation and successful testing and commissioning at 3x1.5 MW Thirot Powerhouse under the supervision of contrctor complete job in all respect as per the direction and entire satisfaction of Engineer-in-Charge | 2 | Job | 60,134 | ₹1,20,268 |
| 3 | Repair and Refurbishment of Nozzle Seat Ring
Scope of work: The work shall comprise comprehensive inspection, repair, refurbishment and precision machining of the existing hydro turbine Nozzle Seat Ring to restore its original design profile, dimensional accuracy, surface integrity and functional performance in accordance with the approved OEM drawings and technical requirements as per the Engineer-In-Charge and also include:
• Initial visual inspection and dimensional assessment to identify erosion, cavitation, corrosion, pitting, cracks, wear and material loss.
• Cleaning and preparation of damaged surfaces, including removal of defective material wherever required and technically permissible.
• Restoration of worn or damaged areas through an approved repair methodology, including weld build-up or material deposition, wherever necessary and suitable for the parent material.
• Precision machining and profile restoration of the nozzle Seat Ring, including the internal water passage, nozzle Seat Ring exit profile, seating surfaces and mounting interfaces, as applicable.
• Restoration of critical dimensions, concentricity, geometrical accuracy and surface finish in accordance with the approved OEM drawings or purchaser-approved dimensional requirements.
• Non-destructive testing (NDT), including Liquid Penetrant Testing (LPT/DPT) and other applicable examination methods, to verify the integrity of repaired areas.
• Final dimensional inspection, surface finish verification and preparation of inspection reports documenting actual measurements and conformity with specified acceptance criteria.
Submission of a comprehensive repair and inspection report, including details of repair methodology, NDT results and final dimensional inspection records and successful testing and commissioning at 3x1.5 MW Thirot Powerhouse under the supervision of contrctor complete job in all respect as per the direction and entire satisfaction of Engineer-in-Charge | 4 | Job | 49,973 | ₹1,99,892 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.81 MB
tenderdoc.pdf
Tender Documents • 0.85 MB
BOQ_218183.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .