Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.9 L+₹14,030 (1.10%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹13.9 L+₹1.1 L (8.74%)Rejected-Finance 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹13.9 L+₹1.1 L (8.80%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹14.5 L+₹1.7 L (13.4%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹18.2 L
EMD Value
₹36,380
Closing Date
23 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Bharat Lal IDSE EE SG
GE(P) CH Chandimandir
REPAIR MAINT REPLACEMENT OF INDOOR FEEDER PILLERS MCCBS AND ACCESSORIES INSTALLED IN SWITCH ROOM AT VARIOUS FLOORS OF CH WC CHANDIMANDIR UNDER GE P CH CHANDIMANDIR
2020_MES_348784_1
GE(P)CH/CHM-11/2020-21
Open Tender
Miscellaneous Works
Item Rate
270 days
GE(P) CH Chandimandir
CLASS E CAT b(i)
8 documents required · 8 mandatory
₹500
Yes
GE(P) CH Chandimandir
₹36,380
Yes
6 Mar 2021
1 Jun 2020
25 Jun 2020
1 Jun 2020
23 Jun 2020
13 Jun 2020
60 days
Amount
Replacement Indicator lamp, LED type of colour red, blue and yellow complete all as specified and directed
Replacement MCCB 250 Amps 4 pole 36 kA Ics=100% Icu, with complete having fixed magnetic setting and adjustable thermal setting with extended terminal for easy connections duly fixed in enclosure made out of 2mm thick MS sheet having 100mm clearance to left and right side of MCCB and 150mm clearance on top and bottom side for easy maintenance, MCCB to fixed on 12mm thick hylam sheet for insulation purpose in MS box and top cover of enclosure to be hinged on one side and lockable on other side including welding 04 Nos MS plate 40x5mm thick 100mm long for fixing the box with existing wall with fixing arrangement and accessories all as specified and directed at site. (Make : Legrand Cat Part No.420239 Or equivalent in siemen/C&S).
Replacement MCCB 200 Amps 4 pole 25 kA Ics=100% Icu, with complete having fixed magnetic setting and adjustable thermal setting with extended terminal for easy connections duly fixed in enclosure made out of 2mm thick MS sheet having 100mm clearance to left and right side of MCCB and 150mm clearance on top and bottom side for easy maintenance, MCCB to fixed on 12mm thick hylam sheet for insulation purpose in MS box and top cover of enclosure to be hinged on one side and lockable on other side including welding 04 Nos MS plate 40x5mm thick 100mm long for fixing the box with existing wall with fixing arrangement and accessories all as specified and directed at site. (Make : Legrand Cat Part No.420239 Or Indo Asian equivalent in siemen/C&S).
Replacement MCCB 400 Amps 4 pole 36 kA Ics=100% Icu with complete having fixed magnetic setting and adjustable thermal setting with extended terminal for easy connections duly fixed in enclosure made out of 2mm thick MS sheet having 100mm clearance to left and right side of MCCB and 150mm clearance on top and bottom side for easy maintenance, MCCB to fixed on 12mm thick hylam sheet for insulation purpose in MS box and top cover of enclosure to be hinged on one side and lockable on other side including welding 04 Nos MS plate 40x5mm thick 100mm long for fixing the box with existing wall with fixing arrangement and accessories all as specified and directed at site. (Make : Legrand Cat Part No.420239 Or equivalent in siemen/C&S).
Replacement MCCB 4 pole 160 Amps 25 kA, Ics=100% Icu with complete having fixed magnetic setting and adjustable thermal setting with extended terminal for easy connections duly fixed in enclosure made out of 2mm thick MS sheet having 100mm clearance to left and right side of MCCB and 150mm clearance on top and bottom side for easy maintenance, MCCB to fixed on 12mm thick hylam sheet for insulation purpose in MS box and top cover of enclosure to be hinged on one side and lockable on other side including welding 04 Nos MS plate 40x5mm thick 100mm long for fixing the box with existing wall with fixing arrangement and accessories all as specified and directed at site. (Make : Legrand Cat Part No.420239 Or equivalent in siemen/C&S).
Replacement MCCB 4 pole 100 Amps 16 kA, Ics=100% Icu with complete having fixed magnetic setting and adjustable thermal setting with extended terminal for easy connections duly fixed in enclosure made out of 2mm thick MS sheet having 100mm clearance to left and right side of MCCB and 150mm clearance on top and bottom side for easy maintenance, MCCB to fixed on 12mm thick hylam sheet for insulation purpose in MS box and top cover of enclosure to be hinged on one side and lockable on other side including welding 04 Nos MS plate 40x5mm thick 100mm long for fixing the box with existing wall with fixing arrangement and accessories fixing in repairs all as specified and directed at site. (Make : Legrand Cat Part No.420239 Or equivalent in siemen/C&S).
Replacement MCCB 3 pole 63 Amps 16 kA, Ics=100% Icu with complete having fixed magnetic setting and adjustable thermal setting with extended terminal for easy connections duly fixed in enclosure made out of 2mm thick MS sheet having 100mm clearance to left and right side of MCCB and 150mm clearance on top and bottom side for easy maintenance, MCCB to fixed on 12mm thick hylam sheet for insulation purpose in MS box and top cover of enclosure to be hinged on one side and lockable on other side including welding 04 Nos MS plate 40x5mm thick 100mm long for fixing the box with existing wall with fixing arrangement and accessories all as specified and directed at site. (Make : Legrand Cat Part No.420239 Or equivalent in siemen/C&S).
MCCB 160 Amps 3 pole 415 volts 25 kA Ics=75% Icu including extended terminals all as specified and directed.Make: Legrand / Siemen/Hager/ C&S/ABB
MCCB 100 Amps 3 pole 415 volts 25 kA Ics=75% Icu including extended terminals all as specified and directed.Make: Legrand / Siemen/Hager/ C&S/ABB
MCCB 63 Amps 3 pole 415 volts 25kA Ics=75% Icu including extended terminals all as specified and directed.Make: Legrand / Siemen/Hager/ C&S/ABB
MCCB 125 Amps 3 pole 415 volts 25 kA Ics=75% Icu including extended terminals all as specified and directed.Make: Legrand / Siemen/Hager/ C&S/ABB
Replacement VTPN DB 4-ways, IP 43 - IK 09 with metal door (DPX3 160+12) suitable for surface/flush mounting as per site requirement with copper bus bar, with neutral bar, earth bar and cable ties for cable arrangement, fully insulated bus bar and neutral bar, door earthing, corner shield for better protection, pan assembly confirming to IS 8623 including making fixing arrangement with existing wall fixing in repairs all as specified and directed. Make : Legrand Cat Part 607913/ Siemen/Hager/C&S/ABB
MCB TPN 63 Amps . 10 KA ,IP 20 protection,C curve,operating voltage 240v/415v AC fixing in repairs complete all as specified and directed.Make : Legrand cat part 4086 83/Indoasian/Hager /Havells
Replacement VTPN DB 12-ways, IP 43 - IK 09 with metal door (DPX3 250+36) suitable for surface/flush mounting as per site requirement with copper bus bar, with neutral bar, earth bar and cable ties for cable arrangement, fully insulated bus bar and neutral bar, door earthing, corner shield for better protection, pan assembly confirming to IS 8623 including making fixing arrangement with existing wall fixing in repairs all as specified and directed. Make : Legrand Cat Part 607924 / Siemen/Hager/C&S/ABB
MCB SP, 'C' series. 10 KA, 240 Volts, 40 Amps capacity fixing in repairs complete all as specified and directed. Make : Legrand/C&S/ Siemens.
Replacment MCB SP, 'C' series. 10 KA, 240 Volts, 6-32 Amps capacity fixing in repairs complete all as specified and directed.. Make : Legrand/C&S/ Siemens.
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit etc. removing materials deposited in store for keeping in safe custody and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated multistranded copper conductor cable 1.1 KV grade (main cable two runs of main cable) alongwith one run of single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade of earth for earthing in concealed conduits with 4 run of 25 Sqmm cable + 2 run of 25 Sqmm as earth cable complete all as specified and directed.
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated multistranded copper conductor cable 1.1 KV grade (main cable two runs of main cable) alongwith one run of single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade of earth for earthing in concealed conduits with 4 run of 10 Sqmm cable + 2 run of 10 Sqmm as earth cable complete all as specified and directed.
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated multistranded copper conductor cable 1.1 KV grade (main cable two runs of main cable) alongwith one run of single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade of earth for earthing in concealed conduits with 2 run of 10 Sqmm cable + 1 run of 10 Sqmm as earth cable complete all as specified and directed.
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated multistranded copper conductor cable 1.1 KV grade (main cable two runs of main cable) alongwith one run of single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade of earth for earthing in concealed conduits with 4 run of 16 Sqmm cable + 2 run of 16 Sqmm as earth cable complete all as specified and directed. Notes: (i) Conduit & conduit accessories shall be measured & paid for separately. For item No 20, 21, 22 & 23 (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE" MAKE OF CABLE: FINOLEX/KEI/RPG/PLAZA.
40mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified and directed.
25 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified and directed.
Cutting chases in existing wall for laying of PVC conduits including making good disturbed surfaces of wall after concealing the conduit in wall complete all as specified directed.
Supply, install testing and commissioning in replacement of Automatic transfer switch (ATS) of capacity three phase 415 Volt, 50Hz, 4 pole and 160 Amp having suitable to 02 incoming and one out going with inbuilt time delay. The ATS should be capable of transfering load of first feeder to second feeder on failure of first feeder and wise versa automatically. the switch should have provision for automatic operation as well as manual operation and should be able for wall mounted including sheet metal enclouser with extrended terminal if required easy fixing of incoming and outgoing connection with free maint of work complete all as specified and directed. Make: Havells cat part No. 1HYFSAO160 or equivalent to L&T.
Supply, install testing and commissioning in replacement of Automatic transfer switch (ATS) of capacity three phase 415 Volt, 50Hz, 4 pole and 100 Amp having suitable to 02 incoming and one out going with inbuilt time delay. The ATS should be capable of transfering load of first feeder to second feeder on failure of first feeder and wise versa automatically. the switch should have provision for automatic operation as well as manual operation and should be able for wall mounted including sheet metal enclouser with extrended terminal if required easy fixing of incoming and outgoing connection with free maint of work. Make: Havells cat part No. 1HYFSAO160 or equivalent to L&T.
On load change over switch 4 pole of capacity 63A in sheet steel enclosure including complete arrangement for fixing on wall Complete all as specified and directed . Make Indo asian/ legrand / C&S / Hager
Replacement of spreaders 3P/ 4P compete all as specified and directed . Make Indoasian/ Legrand/ C&S
Supply and lay XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of 35 Sqmm 3.5 core.Complete all as specified and directed.
Supply and lay XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of 25 Sqmm 3.5 core.Complete all as specified and directed.
Replacement bus bar of alumnium strip of 100 Amps cap insulated with insulator including colour coding mounted on busbar.
Replacement bus bar of copper strip of 100 Amps cap insulated with insulator including colour coding mounted on busbar.
VCB 800A 11 KV (HT) , 3 phase , 50 Hz including taking out VCB trolly and replacement of common truck 12.12.25(P210) ,Checking the maint of barrier and replacing the Damaged parts if any , measurement of insulation resistance between the main circuit terminal , cleaning the surface of vacume inter surface ,measurement of contact resistance across each set of contact , greasing of trolly mounted strip and roller , spring loaded mechanism and hand operating key mechanism including nut bolt and washer and gasket for VCB Cover , complete all as specified and directed. Make : ABB Note : Repair / serviceing of VCB , replaccement of necessary parts under sr No 33,36, 37 & 38 will be carried out through OEM
Repalcement of Vaccum bottles (Complete Poles) for VCB Model VD4 12.12.25, complete all as specified and directed . Make ABB
Checking maint switch operating mechanism and replacement of burnt out mian , auxillary and tripping assembly VCB Model VD4 12.12.25. Make ABB
Replacement of Jaw contact (6 Pcs per set of VCB ) VCB Model VD4 12.12.25 compelete all as specified and directed. Make: ABB
ELECTROMAX OF INDIA
PARTAP ENGINEERING WORKS
AK Construction Co
R D Bansal
M/S Gupta and Sons
Bharat Enterprises
CHADHA ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .