| 1 | L1₹36.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.9 L+₹20,028.25 (0.53%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹38.9 L+₹1.2 L (3.20%)Rejected-Finance 2 755 ELAIYATHAMMAN KOIL MAIN ROAD BHARADHI NAGAR PTMS IAF POST AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹39.5 L+₹1.8 L (4.91%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹40.8 L+₹3.2 L (8.40%)Rejected-Finance PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | L5 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | ACCITE L1 | S K ENTERPRISES L4 | Banyan Engineers and Contractors L5 | G HARI ELECTRICALS L3 | Shri Varaghaa L6 | RUBYONEBUILDERS L2 | SAMYDOSS CONSTRUCTIONS L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Part - I B/R Portion | ||||||||||
| 2.00 | Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and as directed. | 150 | RM | 180 ₹27,000 | 123 ₹18,450 | 100 ₹15,000 Lowest | 120 ₹18,000 | 100 ₹15,000 Lowest | 100 ₹15,000 Lowest | 500 ₹75,000 |
| 3.00 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. | 200 | RM | 120 ₹24,000 | 69 ₹13,800 | 100 ₹20,000 | 60 ₹12,000 Lowest | 100 ₹20,000 | 250 ₹50,000 | 500 ₹1,00,000 |
| 4.00 | Taking out shrubs / vegetation / tree growth from building at any height & any location and applying a Glyphosate pesticide or any other equivalent pesticide in a 10ml of solution with one litre of water on roots using spray gun including taking down cement plaster not exc 0.50 sqm for each tree and making good surface by plastering the same area with 20mm thick plastering in cement mortar 1:4 with WPC and finishing the surface to mathc existing surface with necessary scaffolding and other required T & P complete all as specified and directed . | 120 | Each | 80 ₹9,600 Lowest | 249 ₹29,880 | 150 ₹18,000 | 230 ₹27,600 | 250 ₹30,000 | 210 ₹25,200 | 500 ₹60,000 |
| 5.00 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed . | 20.6 | Cum | 150 ₹3,090 Lowest | 1,545 ₹31,827 | 500 ₹10,300 | 810 ₹16,686 | 250 ₹5,150 | 1,540 ₹31,724 | 1,000 ₹20,600 |
| 6.00 | M & L for 40mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) (Padding concrete) with water proofing compound and finished even and fair complete all as specified and as directed .
Note : Supply only water proofing compound will be measured and paid separately. | 220 | Sqm | 300 ₹66,000 | 222 ₹48,840 Lowest | 270 ₹59,400 | 250 ₹55,000 | 350 ₹77,000 | 228 ₹50,160 | 350 ₹77,000 |
| 7.00 | M & L for screed bed of mortar 15 mm thick in cement mortar 1:4 for laying APP membrane and including mixing water proofing compound as per manufactureres instructions complete all as specified and directed.
Note :- Water proofing compound shall be measured and paid for separately under appropriate item of Sch "A' as supply only. | 220 | Sqm | 550 ₹1,21,000 | 231 ₹50,820 | 270 ₹59,400 | 225 ₹49,500 Lowest | 250 ₹55,000 | 350 ₹77,000 | 300 ₹66,000 |
| 8.00 | Supply only Liquid water proofing compound complete all as specified and as directed . | 29.6 | Ltr | 180 ₹5,328 | 249 ₹7,370.4 | 60 ₹1,776 Lowest | 160 ₹4,736 | 200 ₹5,920 | 220 ₹6,512 | 160 ₹4,736 |
| 9.00 | Preparation of RCC roof surface for waterproofing treatment including cleaning the surface thoroughly with wire brushes to remove dust, loose particles, laitance, and all foreign matter, followed by washing with clean water and allowing it to dry. Applying neat cement slurry @ 3.0 kg of cement per square metre uniformly over the prepared surface. Thereafter, applying one coat of bituminous primer @ 200 gm/sqm and laying 3 mm thick APP (Atactic Polypropylene) modified bituminous membrane weighing not less than 3.5 kg/sqm and reinforced with polyester mat of minimum 160 gm/sqm, laid using torch-on application method with 75 mm overlap on longitudinal joints and 100 mm on transverse joints. All corners, angles, and junctions shall be sealed with cement mortar 1:3 mixed with waterproofing chemical as per manufacturer’s instructions and cured adequately prior to laying of membrane. Finally, applying aluminium paint @ 100 gm/sqm over the membrane surface on both horizontal and vertical faces, including all labour, materials, tools, scaffolding and handling, complete as specified and directed. | 340 | Sqm | 550 ₹1,87,000 | 429 ₹1,45,860 Lowest | 500 ₹1,70,000 | 500 ₹1,70,000 | 500 ₹1,70,000 | 650 ₹2,21,000 | 900 ₹3,06,000 |
| 10.00Note: a)Surface preparation, cement slurry, primer, membrane, and aluminium paint shall be treated as a single composite item and measured under net surface area of application in square metres. b)Overlaps in APP membrane (both longitudinal and transverse) shall not be measured separately. c)Waterproofing chemical for mortar work shall be of approved make and mixed strictly as per manufacturer’s instructions. d)The APP membrane shall have manufacturer’s test certificate indicating thickness, weight, reinforcement class, and conformity to IS:1322/ASTM standards. e)A 5-year warranty shall be furnished by the contractor for the complete waterproofing treatment from the date of completion. f)Aluminium paint shall be applied only after thorough drying and curing of the membrane surface. g)All tools, scaffolding, blow torches, safety equipment, and curing arrangements shall be provided by the contractor at no extra cost. | ||||||||||
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 Jun 2025, 6:00 pmClosed
GE Avadi
Garrison Engineer , Muthapudupet, Air Force Area, Avadi, Chennai-55
SPECIAL REPAIRS TO BLDG NO P-29 AT OF JCOS MD ACCN AND CERTAIN MINOR WORK AT DQA CV AVADI UNDER GE AVADI
2025_MES_713156_1
8287/E8
Open Tender
Civil Works
Item Rate
180 days
GE Avadi
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE Avadi
₹90,000
Yes
6 Aug 2025
9 Jun 2025
2 Jul 2025
9 Jun 2025
30 Jun 2025
18 Jun 2025
9 Jun 2025 - 13 Jun 2025
Amount
Part - I B/R Portion
Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and as directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
Taking out shrubs / vegetation / tree growth from building at any height & any location and applying a Glyphosate pesticide or any other equivalent pesticide in a 10ml of solution with one litre of water on roots using spray gun including taking down cement plaster not exc 0.50 sqm for each tree and making good surface by plastering the same area with 20mm thick plastering in cement mortar 1:4 with WPC and finishing the surface to mathc existing surface with necessary scaffolding and other required T & P complete all as specified and directed .
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed .
M & L for 40mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) (Padding concrete) with water proofing compound and finished even and fair complete all as specified and as directed . Note : Supply only water proofing compound will be measured and paid separately.
M & L for screed bed of mortar 15 mm thick in cement mortar 1:4 for laying APP membrane and including mixing water proofing compound as per manufactureres instructions complete all as specified and directed. Note :- Water proofing compound shall be measured and paid for separately under appropriate item of Sch "A' as supply only.
Supply only Liquid water proofing compound complete all as specified and as directed .
Preparation of RCC roof surface for waterproofing treatment including cleaning the surface thoroughly with wire brushes to remove dust, loose particles, laitance, and all foreign matter, followed by washing with clean water and allowing it to dry. Applying neat cement slurry @ 3.0 kg of cement per square metre uniformly over the prepared surface. Thereafter, applying one coat of bituminous primer @ 200 gm/sqm and laying 3 mm thick APP (Atactic Polypropylene) modified bituminous membrane weighing not less than 3.5 kg/sqm and reinforced with polyester mat of minimum 160 gm/sqm, laid using torch-on application method with 75 mm overlap on longitudinal joints and 100 mm on transverse joints. All corners, angles, and junctions shall be sealed with cement mortar 1:3 mixed with waterproofing chemical as per manufacturer’s instructions and cured adequately prior to laying of membrane. Finally, applying aluminium paint @ 100 gm/sqm over the membrane surface on both horizontal and vertical faces, including all labour, materials, tools, scaffolding and handling, complete as specified and directed.
Note: a)Surface preparation, cement slurry, primer, membrane, and aluminium paint shall be treated as a single composite item and measured under net surface area of application in square metres. b)Overlaps in APP membrane (both longitudinal and transverse) shall not be measured separately. c)Waterproofing chemical for mortar work shall be of approved make and mixed strictly as per manufacturer’s instructions. d)The APP membrane shall have manufacturer’s test certificate indicating thickness, weight, reinforcement class, and conformity to IS:1322/ASTM standards. e)A 5-year warranty shall be furnished by the contractor for the complete waterproofing treatment from the date of completion. f)Aluminium paint shall be applied only after thorough drying and curing of the membrane surface. g)All tools, scaffolding, blow torches, safety equipment, and curing arrangements shall be provided by the contractor at no extra cost.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises complete all as specified and as directed .
M & L for coloured Glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm/ 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles and including rendering 10 mm thick in CM (1:4) on fair faces of brick work complete all as specified and as directed .
M & L for Non-Skid coloured ceramic tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor finishes like tiles complete all as specified and as directed .
M & L for Joint free Non-Skid coloured ceramic tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor finishes like tiles complete all as specified and as directed.
M & L for Joint free Non-Skid coloured ceramic tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in . set and jointed in neat cement slurry and pointed in white or coloured cement to match and rendering 10 mm thick in CM (1:4) on fair faces of brick work complete all as specified and as directed.
M & L for 40mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) cement concrete in sub base complete all as specified and as directed .
Demolition of precast concrete block walling and similar items i.e. ashlar facing dressing stone work, precast concrete articles etc of any description and in any position built in cement mortar including all quoins, arches and pillars etc. complete all as specified and as directed .
M & L for precast cement concrete block masonry with solid blocks exc 10 cm in width and set and jointed in C M 1:6 having ratio of PCC 1:3:6 type C1 (using 20mm graded stone aggregate as directed complete all as specified and as directed .
S & F in repairs of stainless steel kitchen plate rack size 750 x 600 x 250 mm & 0.63 mm thickness of grade AISI 304 incl suitable arrangements for hanging to wall complete all as specified and as directed .
Dismantling of structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed.
M & L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed .
M&L for preparation of new or previously untreated steel surfaces and applying two coats of synthetic enamel paint over a coat of primer red oxide, zinc chrome complete all as specified and as directed.
Taking down of chowkhats / frames n exc 1.50 sqm each without taking off shutter each complete all as specified and as directed .
Taking down of chowkhats / frames exc 1.50 Sqm but n exc 4.0 sqm each without taking off shutter each complete all as specified and as directed .
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. complete all as specified and as directed.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass / stainless steel screws all complete as specified and directed.
S & F of Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as specified and directed.
S & F of Anodised aluminium window powder coating of any colour (Thickness or powder coating not less than 50 micron). and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed .
S & F of 5.5mm thick Sheet glass, ordinary quality and and glazing with oil putty in square n exc 0.5 sq. m in each pane and sheet glass is ground or obscured or frosted, on one side complete all as specified and as directed .
S & F of 5.5mm thick Sheet glass, ordinary quality and and glazing with oil putty in square exc 0.5 sq. m in each pane and sheet glass is ground or obscured or frosted, on one side complete all as specified and as directed by Engineer in charge.
S & F of 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and as directed .
S & F of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed by Engineer in charge.
S & F of aluminium (extruded section) body door closer hydraulically regulated designation No 3, universal type,suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kg complete all as specified and as directed .
Taking down cement plaster of any description from brick wall or concrete surfaces including racking out joints and hacking for key, scrubbing down with water etc complete all as specified and as directed.
M & L for 15 mm thick plaster in CM (1:6) on brick work / RCC concrete surfaces of wall and finish the surface even and smooth without using extra cement complete all as specified and as directed.
M & L for 5 mm thick plaster in CM (1:3) on brick work / RCC concrete surfaces of ceilings complete all as specified and as directed .
M & L for rendering 15 mm thick in CM 1:4 on concrete / fair surfaces of block masonary and including mixing water proofing compound as per manufactureres instructions and finished even and smooth without using extra cement complete all as specified and as directed . Note :- WPC shall be measured and paid for seperately.
M & L for preparation of newly plastered ceiling surfaces and applied three coats of white wash complete all as specified and as directed by Engineer in charge.
M & L for preparation of old plastered ceiling surfaces and applied one coats of white wash complete all as specified and as directed .
M & L for preparation of newly plastered wall surfaces and Providing and applying 3mm thick wall care putty on wall to prepare the surface even and smooth, including priming plastered and other surfaces with alkali resistant priming paint and Material and labour for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work complete all as specified and directed.
M & L for preparation of newly plastered wall surfaces and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by Engineer in charge.
Complete removal of existing treatment on wall (any number of layers) by scarping with steel scrapers or any other mean and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
Complete removal of existing treatment on wall (any number of layers) by scarping with steel scrapers or any other mean including filling depressions of scrapped surface with putty and including priming plastered and other surfaces with alkali resistant priming paint and Material and labour for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work complete all as specified and directed.
Demoltion of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed .
M & L for cement concrete type C-2, 1:3:6 (40mm graded aggregate), 75mm thick. as in plinth protection finished even and smooth without using extra cement including expansion joints complete all as specified and as directed .
Taking up or down steel tubing / CPVC Pipes and connection including cleaning for refixing or removed to store complete for following sizes all as specified and as directed .
16 mm bore
20 mm bore.
25 mm bore.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified & directed of following sizes :-
16 mm outer dia
20 mm outer dia
25 mm outer dia
Cutting chases, pinning in making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good ,cutting n, exc. 10cm girth complete all as specified and as directed .
S & F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white, including trap and connection to drain and flushing pipe (excluding flushing cistern) including seat cover with recessed bottom and mild steel chromium plated or aluminium hinging devices for pedstal pan and Flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and as directed .
S & F in repair vitreous China squatting pan, 'Orissa patteren, size 580 x 440 mm white, with integral footrests including provision of lime concrete bedding (excluding flushing cisteren and flush pipe) and supply and fixing of Flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and directed .
S & F in repairs Vitreous China Wash basins, white, flat back, size 630x450mm, including cutting for and pinning in ends of brackets or erecting stand but inclusive of supply and fixing of waste couplings and waste pipe complete all as specified and as directed.
S & F in repairs 10 litre capacity PVC low level flushing cistern with all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete all as specified and as directed.
S & F in repair PVC connection 15mm size PTMT nuts of length 450 mm complete all as specified and as directed .
S & F in repair 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed .
S & F in repair of two way bib cock chromium plated fancy type 15 mm bore with wall flange complete all as specified and as directed .
S & F in repair fancy type CP pillar tap with capstan heads, spindles and washer plates cofirm to IS 1795 having mark 'Cold' or 'Hot' and weight not less than 0.65 Kg complete all as specified and as directed
S & F in repair 15 mm bore fancy type bib taps long body cast copper alloy chromium plated, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed .
S & F in repairs to health faucet with 1200 mm long flexible 32mm dia outlet pipe and having 184.5mm length of handle with wall hook complete all as specified and as directed.
S & F in repairs 15 mm bore overhead shower Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
S & F in repair CP Soap dish of having size 160x 160x90mm, fixed to plugs with chromium plated brass screws complete all as specified and as directed.
S & F in repairs Tubular towel rail, 20mm dia, D type, 60cm long between flanges brass chromium plated complete all as specified and as directed.
S & F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long below WHB mirror complete all as specified and as directed.
S & F in repairs SS cockroach trap / nahani trap having size of 150mm x 150mm in sqaure shape SS 304 Grade glossy finish complete all as specified and as directed .
S & F in repairs SS floor drain having dia of 125mm in circular shape SS 304 Grade glossy finish with or without hole for waste pipe complete all as specified and as directed.
S & F in repairs PVC Waste pipe / outlet connector pipe 32mm dia / 40mm and length 1150mm and corrugated profile for fixing in WHB / Sink complete all as specified and as directed .
S & F of 25 mm bore ball brass valves,high pressure,with polythene float and flunut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed .
S & F in repairs 25 mm bore dia gun-metal,globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
Dismantling water tanks and removing to store Exc 500 litre & n exc 1000 litre amd Supply and fixing of 1000 litre capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed .
Taking down of chowkhats / frames n exc 1.50 sqm each without taking off shutter each complete all as specified and as directed.
Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm single piece extruded PVC profiles reinforced with 19 x 19mm MS square tube provided with EPDM rubber gasket weather seal through out the frame and the profile mitre cut at two corners and joined by inserting 2 nos 150mm long brackets of 15 x 15mm MS square tube inside 19 x 19mm MS square tube suitably screwed complete all as specified and as directed .
Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes of size 15 x 15mm for top and bottom rails and 19 x 19mm for stiles, MS frame covered with 5mm thick single piece extruded PVC profile 'C' channel having a 5mm thick PVC sheet strip of 20mm width struck inside with solvent cement, forming stiles, and 5mm thick single piece extruded PVC profile for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail; panelling of 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc all as per manufacturer's instructions and drawings as shown in SSR Part-I 2009 complete all as specified and as directed .
S & F of aluminium anodised 200 mm barrel tower bolts of extruded section complete all as specified and as directed by Engineer in charge.
S & F of 150mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed .
S & F of 100 mm butt hinges extruded aluminium alloy with galvanized mild steel hinges pin anodised type `C'-22 complete all as specified and as directed .
S & F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement morter to dwarft wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed .
S & F of 40mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed .
S & F of stainless steel decorative curtain rod of 25 mm bore (weight not less 400 gms per running meter) incl fancy finial caps (02 nos in each curtain rod) etc complete all as specified and as directed .
S & F of Brass Chromium Plated designer Bracket for curtain rod of dia 25 mm dia made out of SS Flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with Rawl Plug of size not less than 50 mm long etc complete all as specified and as directed .
S & F of Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed.
S & F of small articles of steel such as hold fast, etc of Gde Fe 410-0 or Fe-290 Gde E-165 complete all as specified and as directed .
M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in hold fast etc complete all as specified and as directed .
Material and labour for preparation of wood and wood based materials, new or old, of any description and girth, not otherwise described, and treating ends of posts,back of chowkhats,etc. area tarred exc 0.1 sq m but n. exc. 0.5 sq m each and treated with tar or coal tar black paint complete all as specified and as directed.
Material and labour for preparation of wood and wood based materials, new or old, of any description and girth, not otherwise described, treating small articles such as holdfasts,end of posts,backs of chowkhats, etc area n. exc. 0.1 sq m each and treated with tar or coal tar black paint complete all as specified and as directed .
S & F of 35 mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers , etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed .
S & F of factorymade 35mm thick 2nd class hardwood rail and style Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed .
S & F of 30 mm thick flush shutter, solid core construction, with block board core and plywood face panel, commercial type on both sides complete all as specified and as directed .
S & F of aluminium anodised 200 mm barrel tower bolts of extruded section complete all as specified and as directed by Engineer in charge.
S & F of 150mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed .
S & F of 100 mm butt hinges extruded aluminium alloy with galvanized mild steel hinges pin anodised type `C'-22 complete all as specified and as directed .
S & F of 300mm long aluminium alloy, anodised sliding door bolt with haps, staple(bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and as directed.
S & F of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
M & L for providing water proofing treatment to sunken portion of WCs, bathroom etc by applying cement slurry mixed with two component Elastomeric Acrylic based polymer modified cementitious composite compound coating. incl taking down existing treatment incl demolition of PCC as in sunken protion of Toilet, Bathroom etc and removing beyond the premises of site complete all as specified and as directed. The following procedures to be adopted during the execution of work :- (a) M & L for cleaning of the sunken / lowered portion of the RCC slab surface (including vertical total depth plus 300mm above FFL) of floors by wire brush, chiesel out any mortar sticking to the surface and brooming / washing completely. (b) Rendering of uneven surfaces with 5 mm thick CM 1:4 mixed with and incl integral liquid WPC as per mannufacturer instruction. Fill it with water and check dampness and seepage. where dampness and seepage noticed nozzles shall be fixed and epoxy grouting to be carried out. (c) All junctions points of side walls where PVC pipes are passing through shall be sealed with epoxy putty and After drying of putty, washing the slab and sides of sunken portion with water and make it clean and clear .
(d) First layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm. The layer will be allowed to air cure for 4 hours. (e) Second layer of slurry of cement @ 0.242 kg/sqm mixed with with Acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm. The layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (f) Provide 40mm dia medium grade GI spout at the lowest point with 400mm long. (g) 50 mm Avg thick PCC 1:2:4 type B-0 using 12.5 mm graded aggregate as in padding conc to achieve proper slope with WPC and All pipes laid in sunken portion shall be covered with 50 mm thick PCC 1:3:6. (h) Cement concrete PCC 1:5:10 type E-2 using 20mm graded brick aggregates as in sunken portion. (j) 20mm thick screed in cement mortar 1:3 mixed with liquid water proofing compound. Note : (i) For Payment purpose, plan area of Sunken portion to be measured. (ii) Testing the water proofed area (ponding test) by filling water for atleast 72 hours and tested for leakage seepage and to the entire satisfaction of GE . (iii) Test shall be done in presence of reps of user and photographical record for each sunken slab shall be maintained. (iv) The treatment shall be carried out by authorised applicators of chemicals.
S & F of factory made 18mm thick single extruded WPC (Wood Plastic composite) solid board of any colour, texture and pattern for cup board as in Kitchen cabinet and loft shutter and similar nature of work of required sizes comporising of virsin polymer of K Value 58-60 (Suspension grade), Calcium carbonate and natural fibres(wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density 650kg/cum and screw withdrawl strength of 1800N (Face) & 900 N (Edge) , minimum compressive strength 50 N/mm2, modulus of elasticity 850N/mm2 and resistance to spread of flame of Class A category with property of being termite / borer proof, water / moisture proof, and fire retardent complete all as specified and as directed
S & F of stainless steel Auto / Self closing concealed hinges 9.5 cranks for half overlay doors with opening angle 95* (14-32mm) with integrated overlay adjustment +_ 2.50mm & depth adjustment 4mm complete all as specified and as directed .
S & F of round stainless steel cabinet knobs handlers dia of 27mm complete all as specified and as directed by Engineer in charge.complete all as specified and as directed.
S & F of floor door stopper of aluminium alloy body and tongue, anodised , with hard drawn steel spring overall length of cover plate 140 mm, complete all as specified and as directed by Engineer in charge.
M & L for preparation of new wooden surfaces of any description, not otherwise described,over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary paint tint) (each coat) over a coat of pink primer including scaffoldings of any hieght complete all as specified and as directed .
Demolition of stone slabs and tiles of any description or thickness in floors, aprons,dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site complete all as specified and as directed .
M & L for granite (of any colour) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform, counter for wash basin, flooring and all other similar works and 15mm thick screed bed mortar in CM 1:4 complete all as specified and as directed .
M & L for Machine cut kota stone slab flooring 20-25mm thick ini flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and 15mm thick screed bed mortar in CM 1:4 complete all as specified and as directed .
M & L for Machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing rendering 10 mm thick in CM (1:4) on fair faces of brick work complete all as specified and as directed .
Demolition and breaking up drain pipes upto 100/110 mm dia (Salt glazed ware, AC, PVC or reinforced concrete) set in cement mortar complete all as specified and as directed .
Demolition and breaking up drain pipes upto 75 mm dia (Salt glazed ware, AC, PVC or reinforced concrete) set in cement mortar complete all as specified and as directed .
Supply and fixing of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall/floor with suitable clamp complete all as specified and as directed
Supply and fixing of 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall/floor with suitable clamp complete all as specified and as directed .
Supply and fixing of PVC (SWR) junction single, (single T) equal or unequal provided with access door suitable for 110mm bore PVC pipes complete all as specified and as directed .
Supply and fixing of PVC (SWR) bends any radius suitable for 110mm bore PVC pipes with access door complete all as specified and as directed by Engineer in charge.complete all as specified and as directed .
Supply and fixing of PVC (SWR) bends any radius suitable for 75mm bore PVC pipes with access door complete all as specified and as directed.
Supply and fixing of PVC (SWR) vent cowl for 110mm bore PVC pipes complete all as specified and as directed .
Supply and fixing of PVC (SWR) WC connector bent type for 110mm bore PVC pipes complete all as specified and as directed .
Supply and fixing of PVC (SWR) for 75mm Diameter of outlet floor trap, plain with grating including jointing with solvent cement etc complete all as specified and as directed .
Supply and fixing of PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed.
Part - II Internal Electrification (E/M)
Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc.,removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc.,complete all as specified and as directed.
Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated FRLSH ,1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly, including Modular boxes, frames and cover plates all as specified and as directed for (a) one light point controlled by one switch. Note : Cost of Modular box, frame, cover plates and cutting chases for concealing pipes is deemed to be included in the item rates quoted for point wiring.
One ceiling fan point controlled by one switch and regulator
One Exhaust fan point controlled by one switch.
One bell / buzzer point controlled by one bell push
One switch socket outlet 3 pin 5 Amps on same board along with other switches
One switch socket outlet 3 pin 5 Amps on independent board.
All as per item No 123.00 here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded FRLSH cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor green in colour including steel box of required module for modular switches/sockets all as specified for one 3 pin switch socket outlet, 15 Amps, complete all as specified and as directed.
Supply and Fixing Modular switch 1 way 6A, 1 module complete all as specified and as directed
Supply and Fixing Modular switch 1 way16A, 1 module complete all as specified and as directed
Supply and Fixing Modular Bell push 6A, 1 module complete all as specified and as directed
Supply and Fixing Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed
Supply and Fixing Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed
Supply and Fixing Modular fan step regulator , 120w, 2 module complete all as specified and as directed
S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface complete all as specified and as directed
S&F Bell ding-dong type , AC, 215 volts, 50 HZ complete all as specified and as directed
S&F for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including LED Bulbs 9/10 Watts complete all as specified and directed.
Taking down carefully Power / Sub main wirings with PVC aluminum conductor cables in PVC/STEEL conduits / TW battens up to 2 runs of 4/6 Sq.mm removing materials from site, taken as credit , making good the disturbed surfaces all as specified and as directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 4 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 4 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting to common earth dolly complete all as specified and as directed.
Supply and Fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
Taking down existing unserviceable MCB's/MCCB's/DBs any capacity complete all as specified & directed .
S&F MCB DB SPN 08 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, fixed on wall semi flush type, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevant items.
S&F Load line MCB DB TP&N 4 way, vertical, double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for FP MCCB 100 Amps as incomer and SP MCBs 32 amps as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming MCCB and Outgoing MCB measured separately relevant items.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and Neutral current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning completeall as specified and directed.
S&F MCCB 100 Amps 415V,16KA, 4 Pole complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20/22W, 220V,AC with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 9/10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete aall as specified and directed.
S&F LED building security light fitting 45 W made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07, complete pre-wired and connecting up with suitable twin core flexble copper wire including provision of necessary GI tubing medium grade 25mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to Bldg etc complete all as specified and as directed.
Supply & fix ceiling fans ceiling BLDC type complete with accessories 230 V,1400 mm sweep. BEE 5 star rated with provn of necesary hanging hook on ceiling complete all as specified and directed.
S&F of Exhaust fan, heavy duty, 450 mm sweep, 1370 RPM, with louvers, metal body conforming to IS, AC single phase, 240 Volts, 50 Hz and connecting including provision of two way PVC connectors, 1.50 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan including earthing and fixing arrangements complete all as specified and as directed.
S & F Ventilation fan 200mm sweep, Power 22 W, Operating voltage 230 Volts with louvers and shutters plastic body type with all accessories and connecting up with suitable size 1 sqmm three core copper conductor flexible wire,screws,gutties complete all as specified and directed.
M&L for making hole for fixing of ventilation fan/Exhaust fan size 200/300 mm with necessary civil work, alteration in exist ventilation window of iron/aluminium frame for fixing of fan as per site requirement complete make good the wall/ventilation window match with exist complete all as specified and directed.
Supply and fix Water heater storage type, electric, capacity 25 litres, BEE 5 star rated (incl inlet, out let pipes), adjustable thermostat, Efficient long-life copper heating element, Shock-resistant and rust-proof engineering, thermoplastic body, IPX4 waterproof technology, tank designed to withstand 8 bar pressure, tank marine grade glass line coated,PUF insulation, Magnesium anode complete with all fixing arrangements all as specified and directed.
Material and labour for earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire all as specified and directed .
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Part - III External Electrification (E/M)
Supply, laying and testing cable XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables 1100 Volts grade with stranded aluminium conductor of size 35 sqmmx 3.5 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out any type of soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed.
Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
Laying in trenches fine sieved excavated dry soil including spreading/ leveling, cushioning for underground cables all as specified and as directed.
Supply and laying of common burnt clay building bricks, sub class B size for cable protection all as specified and as directed.
Material and labour for GI tubing light grade 50 mm for cable protection laid in trenches in road crossing or fixed to wall/Pole complete all as specified and as directed.
M & L for Cutting of road/path for laying of GI tubing and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded stone aggregate all as specified and directed.
Part - IV (04 X 1.5 TON Split Air Conditioner)
Supply, installation and testing of hi wall split units indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with minium 5 star rating inverter Airconditioner 1.5 Ton capacity with copper condensing coil complete all as specified and as directed .
Supply and fix Voltage stabilizer for automatic operation, single Phase naturally air cooled indoor type & designed for input variation between 90V to 260V with output voltage stabilized at 230v with accuracy of +/- 2.5% and of capacity of 4.0 KVA complete all as specified and as directed.
Supply and Fix Supporting MS frame for Outdoor Unit all as specified and directed.
Supply and Fix 240V 20 Amps Single Pole and neutral enclosure with a two Pin and earth Plug and Socket Complete with one single pole MCB complete all as specified and as directed.
Wiring for circuit / submain wiring alongwith earth wire 4.0 sqmm sizes of FR is PVC insulated copper conductor , single core cable in surface / recessed as required 2x4.0 sqmm+1x4.0 sqmm earth wire.in PVC conduit wiring all as specified and directed.
Supply and Fix SPN MCB 32 Amp,10KA,"C" curve complete all as specified and as directed.
Supply and fix copper tubing set 1/4" and 1/2" suitable for Split AC including PUF insulation and connected accessories complete all as specified and directed.
RUBYONEBUILDERS (BID ID -3332360)
G HARI ELECTRICALS (BID ID -3341666)
S K ENTERPRISES (BID ID -3333956)
Banyan Engineers and Contractors (BID ID -3340627)
Shri Varaghaa (BID ID -3334010)
SAMYDOSS CONSTRUCTIONS (BID ID -3332978)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .