Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.6 LAccepted-AOC 433 USTAD AMIR KHAN SARANI HARIDEVPUR KOLKATA 700082 | KOLKATA | KOLKATA | WEST BENGAL | 700082 | L-1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L-2₹1.6 L+₹220.48 (0.14%)Rejected-Finance 33 LINTON STREET 33 LINTON STREET 33 LINTON STREET 33 LINTON STREET VILLAGE TOWN 33 LINTON STREET CITY KOLKATA KOLKOTA WEST BENGAL 700014 INDIA | KOLKATA | WEST BENGAL | 700014 | L-2 | Rejected-Finance GREATER THAN L-1 | |
| 3 | L-3₹1.6 L+₹431.46 (0.27%)Rejected-Finance 32A MAHATMA GANDHI ROAD KOLKATA 700041 | KOLKATA | KOLKATA | WEST BENGAL | 700041 | L-3 | Rejected-Finance GREATER THAN L-1 |
| Sl No | Description | Qty | Unit | SOUMEN ELECTRIC L1 | SUJATA ENTERPRISE L3 | MAITY ENTERPRISE L2 |
|---|---|---|---|---|---|---|
| 1.00 | Withdrawing the 2 nos. existing damaged 250mm dia CIDF NRV from the delivery pipe line of 90KW HSC centrifugal pump with the help of existing lifting arrangement for replacement as per direction of EIC.
( for P-3 & 6 of route-II) | 1 | no. | 10,000 ₹11,918 Lowest | 10,020 ₹11,941.84 | 10,010 ₹11,929.92 |
| 2.00 | Supply and delivery of following materials at site:-
CIDF PN: 1.6 rating DN250 single door swing check NRV generally conforming to IS:5312 Part I, having body, door, cover in graded cast iron to IS:210 Gr. FG200, body and door rings & bearing block of leaded tin bronze to IS: 318 GR. LTB 2, hinge pin of st. AISI410, valve suitable for a maximum working pressure of 16 Kg/Sq.cm ( seat test) & body tested to 24 kg/sq.cm.
Carrying charges for valve | 2 | nos. | 75,376 ₹89,833.12 Lowest | 75,430 ₹89,897.47 | 75,400 ₹89,861.72 |
| 3.00 | M20 X 100mm long M.S Bolt. | 30 | nos. | 3,300 ₹3,932.94 Lowest | 3,360 ₹4,004.45 | 3,330 ₹3,968.69 |
| 4.00 | M20 X 450mm long M.S full thred stud. | 4 | nos. | 1,372 ₹1,635.15 Lowest | 1,392 ₹1,658.99 | 1,380 ₹1,644.68 |
| 5.00 | M20 X 250mm long M.S full thred stud. | 8 | Nos. | 2,400 ₹2,860.32 Lowest | 2,464 ₹2,936.6 | 2,440 ₹2,907.99 |
| 6.00 | M20 Hex Nut | 70 | nos. | 1,610 ₹1,918.8 Lowest | 1,645 ₹1,960.51 | 1,624 ₹1,935.48 |
| 7.00 | Washer for above Nut | 40 | nos. | 480 ₹572.06 Lowest | 492 ₹586.37 | 486 ₹579.21 |
| 8.00 | Gasket | 1 | item | 1,489 ₹1,774.59 Lowest | 1,496 ₹1,782.93 | 1,492 ₹1,778.17 |
| 9.00 | Fitting fixing of the above newly supplied NRV ( as in item no. 2.01) in the existing pipe line along with supplied bolt-nut, stud & gasket (as in item no. 2.02 to 2.07) with the help of existing lifting arrangement as per requirement
( for P-3 & 6 of route-II) | 1 | item | 13,500 ₹16,089.3 Lowest | 13,525 ₹16,119.1 | 13,515 ₹16,107.18 |
| 10.00 | Repairing of gear box of DN250 mm Actuator | 1 | no | 10,000 ₹11,918 Lowest | 10,025 ₹11,947.8 | 10,010 ₹11,929.92 |
Tender Value
Refer Docs
EMD Value
₹3,800
Closing Date
12 Jun 2026, 5:00 pmClosed
Assistant Engineer, Haldia Electrical Sub-Division
Government of West Bengal Office of the Assistant Engineer, Haldia Electrical Sub-Division P.H. Engineering Directorate Barada, Chaitanyapur, Haldia, Purba Medinipur
Repairing of DN250 NRV at CLWPH of WTP, under Panskura-II block in the District of Purba Medinipur under MMD PHE Dte.
2026_PHED_1025479_2
WBPHE/AE/HESD/NIeT01OF202627
Open Tender
Electrical Work/ Equipment
Item Wise
15 days
Haldia, Purba Medinipur
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,800
19 Jun 2026
29 May 2026
15 Jun 2026
1 Jun 2026
12 Jun 2026
1 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.0 | Withdrawing the 2 nos. existing damaged 250mm dia CIDF NRV from the delivery pipe line of 90KW HSC centrifugal pump with the help of existing lifting arrangement for replacement as per direction of EIC.
( for P-3 & 6 of route-II) | 1 | no. | - | - |
| 0.0 | Supply and delivery of following materials at site:-
CIDF PN: 1.6 rating DN250 single door swing check NRV generally conforming to IS:5312 Part I, having body, door, cover in graded cast iron to IS:210 Gr. FG200, body and door rings & bearing block of leaded tin bronze to IS: 318 GR. LTB 2, hinge pin of st. AISI410, valve suitable for a maximum working pressure of 16 Kg/Sq.cm ( seat test) & body tested to 24 kg/sq.cm.
Carrying charges for valve | 2 | nos. | - | - |
| 0.0 | M20 X 100mm long M.S Bolt. | 30 | nos. | - | - |
| 0.0 | M20 X 450mm long M.S full thred stud. | 4 | nos. | - | - |
| 0.0 | M20 X 250mm long M.S full thred stud. | 8 | Nos. | - | - |
| 0.0 | M20 Hex Nut | 70 | nos. | - | - |
| 0.0 | Washer for above Nut | 40 | nos. | - | - |
| 0.0 | Gasket | 1 | item | - | - |
| 0.0 | Fitting fixing of the above newly supplied NRV ( as in item no. 2.01) in the existing pipe line along with supplied bolt-nut, stud & gasket (as in item no. 2.02 to 2.07) with the help of existing lifting arrangement as per requirement
( for P-3 & 6 of route-II) | 1 | item | - | - |
| 0.0 | Repairing of gear box of DN250 mm Actuator | 1 | no | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
Tendernotice_2.pdf
PDF • 0.30 MB
BOQ_2519897.xls
BOQ • 0.29 MB
EtenderNoticofAEHESD01of202627.pdf
Tender Documents • 0.57 MB
WB2911.pdf
Additional Documents • 1.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .