Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAdmitted-Fee/PreQual/Technical/Finance | ₹1.9 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹1.9 L+₹0.13 (<0.01%)Admitted-Fee/PreQual/Technical/Finance | ₹1.9 L+₹0.13 (<0.01%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹2.0 L+₹5,887.99 (3.04%)Admitted-Fee/PreQual/Technical/Finance | ₹2.0 L+₹5,887.99 (3.04%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | L4₹2.1 L+₹13,244.33 (6.84%)Admitted-Fee/PreQual/Technical/Finance | ₹2.1 L+₹13,244.33 (6.84%) | L4 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | L5₹2.1 L+₹17,934.33 (9.27%)Admitted-Fee/PreQual/Technical/Finance | ₹2.1 L+₹17,934.33 (9.27%) | L5 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | N CHANDRU L3 | N DINESH KUMAR L4 | N S CHELLAPANDIAN L2 | K RAVICHANDRAN L5 | Delve engineering Private limited L1 |
|---|---|---|---|---|---|---|---|---|
| 1.01 | Supply and delivery of 9m Free Standing 8 sided Octogonally continously tapered structured pole with base plate of size 300 x 300 x 12mm as per IS-875 with following specification.
Bottom Pole Dia - 130mm,D11 Top Pole Dia - 70 mm
Thickness of Pole - 3 mm,The pole should be hot dip galvanized confirming to BESN ISO-1461 with thickness of 65 Micron With lader | 1 | Nos | 26,075 ₹26,075 | 25,550 ₹25,550 | 25,305 ₹25,305 Lowest | 27,650 ₹27,650 | 25,983.04 ₹25,983.04 |
| 2.01 | Supply and delivery of 200W LED (Flood light Type) Lamp Fittings made of pressure die cast aluminium housing with heat resistant toughened glass cover confirming to IP65. Separate compartment for LEDs & electronic driver with CCT of 5700K, PF > 0.9. System efficacy >85, Operating Volage Range120 -270 ~ Rated Power 200W Current (A) @240V 0.880, Wattage (W) @ 240V - 200W , Power Factor >0.9 Current Harmonics (THD) <10% Operating Conditions Operating Frequency 50Hz Operating Temperature Range -20°C to +50°C Colour Temperature Cool White (5700+_300K) Luminous Flux >22000 Lumens package not less 100 - 110 lm/W Life Span > 50,000 Hours Approx,waight in (KG) 12.65kg :. Body Alluminium Die casting Body Heat Sink Optimized thermal design to ensure maximum life.Protection of IP 65 Standards for Dust and Water including interconnection etc; complete as per Standard Specification.as directed by the departmental officer. ( Need to get a DMA Approved 3rd party Testing Certificate) | 6 | Nos | 14,751 ₹88,506 | 16,060 ₹96,360 | 14,315.4 ₹85,892.4 | 15,642 ₹93,852 | 11,632.88 ₹69,797.28 Lowest |
| 3.01 | 1 Mtr dia galvanised Tubular Ring Made up to 40mm x3mm "C" Class galvanised Pipe for Mini mast | 1 | Nos | 5,587.5 ₹5,587.5 | 5,475 ₹5,475 | 5,422.5 ₹5,422.5 | 5,925 ₹5,925 | 2,892 ₹2,892 Lowest |
| 4.01 | Concreting and masonary work for the foundation including hire charges for welding machine compressor etc for Mini mast | 1 | Job | 8,940 ₹8,940 | 8,760 ₹8,760 | 8,676 ₹8,676 Lowest | 9,480 ₹9,480 | 23,903.17 ₹23,903.17 |
| 5.01 | Labour Charges for erection of the pole and fixing the fittings, testing and commissioning of the lights including hire charges for crane for Mini mast | 1 | Job | 9,312.5 ₹9,312.5 | 9,125 ₹9,125 | 9,037.5 ₹9,037.5 Lowest | 9,875 ₹9,875 | 11,154.81 ₹11,154.81 |
| 6.01 | Supply and run of 2 of 4 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100V on 7 /20 GI bearer wire for service connection mains. | 90 | Mtr | 111 ₹9,990 | 108.77 ₹9,789.3 | 107.73 ₹9,695.43 Lowest | 117.71 ₹10,593.9 | 127.48 ₹11,473.2 |
| 7.01 | Supply and Erection of Panel Board subscribed with EB service Board, 25A Contactor-1 No, 16A 2 Pole MCB-1 No, Timer-1 No and Toggle Switch-1No.for Mini Mast | 1 | No | 18,252.5 ₹18,252.5 | 17,885 ₹17,885 | 17,713.5 ₹17,713.5 | 19,355 ₹19,355 | 10,836.11 ₹10,836.11 Lowest |
| 8.01 | Earthing as per the ISI Specification with and earth electrode of 2.1 mt Class 'B' GI pipe of dia not less than 40mm, with Copper earth plate of Size 125mm x 50mm x6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC Cover Siad for the brick masonry. | 1 | No | 2,334.1 ₹2,334.1 | 2,287.09 ₹2,287.09 | 2,265.16 ₹2,265.16 Lowest | 2,475.07 ₹2,475.07 | 7,967.72 ₹7,967.72 |
| 9.01 | Add GST 18% | 1 | GST | 30,419.1 ₹30,419.1 | 31,541.65 ₹31,541.65 | 29,521.35 ₹29,521.35 Lowest | 32,257.07 ₹32,257.07 | 29,521.38 ₹29,521.38 |
Tender Value
₹2.7 L
EMD Value
₹2,677
Closing Date
16 Sept 2026, 3:00 pmClosed
The Commissioner Madurai Corporation
Aringar Anna Maligai, Thallakulam, Madurai.
Supply and Erection of 9M Mini Mast with 6 Nos 200 W LED Flood Lamp at South Avani Moola street Appavu Chettoar Jewellery opp side ward no 52.
2026_MAWS_700006_1
E7/Est No 19/26-27 (MP)
Open Tender
Civil Works
Lump-sum
Madurai
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹2,677
16 Sept 2026
1 Sept 2026
16 Sept 2026
1 Sept 2026
16 Sept 2026
1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply and delivery of 9m Free Standing 8 sided Octogonally continously tapered structured pole with base plate of size 300 x 300 x 12mm as per IS-875 with following specification.
Bottom Pole Dia - 130mm,D11 Top Pole Dia - 70 mm
Thickness of Pole - 3 mm,The pole should be hot dip galvanized confirming to BESN ISO-1461 with thickness of 65 Micron With lader | 1 | Nos | - | - |
| 2.01 | Supply and delivery of 200W LED (Flood light Type) Lamp Fittings made of pressure die cast aluminium housing with heat resistant toughened glass cover confirming to IP65. Separate compartment for LEDs & electronic driver with CCT of 5700K, PF > 0.9. System efficacy >85, Operating Volage Range120 -270 ~ Rated Power 200W Current (A) @240V 0.880, Wattage (W) @ 240V - 200W , Power Factor >0.9 Current Harmonics (THD) <10% Operating Conditions Operating Frequency 50Hz Operating Temperature Range -20°C to +50°C Colour Temperature Cool White (5700+_300K) Luminous Flux >22000 Lumens package not less 100 - 110 lm/W Life Span > 50,000 Hours Approx,waight in (KG) 12.65kg :. Body Alluminium Die casting Body Heat Sink Optimized thermal design to ensure maximum life.Protection of IP 65 Standards for Dust and Water including interconnection etc; complete as per Standard Specification.as directed by the departmental officer. ( Need to get a DMA Approved 3rd party Testing Certificate) | 6 | Nos | - | - |
| 3.01 | 1 Mtr dia galvanised Tubular Ring Made up to 40mm x3mm "C" Class galvanised Pipe for Mini mast | 1 | Nos | - | - |
| 4.01 | Concreting and masonary work for the foundation including hire charges for welding machine compressor etc for Mini mast | 1 | Job | - | - |
| 5.01 | Labour Charges for erection of the pole and fixing the fittings, testing and commissioning of the lights including hire charges for crane for Mini mast | 1 | Job | - | - |
| 6.01 | Supply and run of 2 of 4 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100V on 7 /20 GI bearer wire for service connection mains. | 90 | Mtr | - | - |
| 7.01 | Supply and Erection of Panel Board subscribed with EB service Board, 25A Contactor-1 No, 16A 2 Pole MCB-1 No, Timer-1 No and Toggle Switch-1No.for Mini Mast | 1 | No | - | - |
| 8.01 | Earthing as per the ISI Specification with and earth electrode of 2.1 mt Class 'B' GI pipe of dia not less than 40mm, with Copper earth plate of Size 125mm x 50mm x6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC Cover Siad for the brick masonry. | 1 | No | - | - |
| 9.01 | Add GST 18% | 1 | GST | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
docup.pdf
Tender Documents • 0.86 MB
BOQ_841452.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .