| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹38.6 L+₹1.4 L (3.73%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹38.6 L+₹1.4 L (3.79%)Rejected-Finance | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder | |
| 4 | L4₹40.5 L+₹3.3 L (9.00%)Rejected-Finance H NO 1 BLOCK NO 2 SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L4 | Rejected-Finance Rejected being 4th Lowest Bidder | |
| 5 | L5₹42.1 L+₹4.9 L (13.3%)Rejected-Finance | L5 | Rejected-Finance Rejected being 5th Lowest Bidder |
Tender Value
₹59.9 L
EMD Value
₹1.1 L
Closing Date
5 Feb 2020, 6:00 pmClosed
CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
SPECIAL REPAIRS / REPLACEMENT OF ACC SHEET OF BUILDING NO. P-683, P-686 TO P-689, P-691 TO P-695 AND SPECIAL REPAIR TO BUILDING NO. T-529 AND T-531 OF MILITARY HOSPITAL AND PROVISION RAIN WATER HARVESTING FOR CHILDREN SCHOOL AT MIL STN SRI GANGANAGAR
2019_MES_284722_1
CA NO. CWE SGNR - 39 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
GE SRI GANGANAGAR
Class C
Category a(i)
10 documents required · 10 mandatory
₹1,000
GE SRI GANGANAGAR
₹1.1 L
Yes
24 Feb 2020
1 Jan 2020
7 Feb 2020
1 Jan 2020
5 Feb 2020
22 Jan 2020
Amount
Dismantling asbestos cement (corrugated / semi corrugated) sheets including ridges as in roof covering all as specified & directed by Engineer-in-Charge.
Dismantling of wall and ceiling boards any thickness including cover fillets complete all as specified & directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, pillars etc of any description and in any position complete all as specified and directed by Engineer-in-Charge.
Dismantling of floor, hearth or wall tiling including cement mortar bedding and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with old size fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
S&F Pre- painted galvalume aluminium zink coating GI based corrugated sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws all as specified and directed by Engineer-in- charge.
&F Pre- painted galvalume aluminium zink coating GI based plain sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in in ridges, hips, valley gutter , drip and straight flashing all as specified and directed by Engineer-in- charge.
S&F Pre- painted (green) galvalume aluminium zink coating GI based corrugated sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws all as specified and directed by Engineer-in- charge.
&F Pre- painted (green) galvalume aluminium zink coating GI based plain sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in in ridges, hips, valley gutter , drip and straight flashing all as specified and directed by Engineer-in- charge.
S&F PVC false ceiling consisting of 600mmx 600mmx 5mm thick plain PVC sheet as panel fixed in GI Snap Grid Frame work using 'T' section of size 25mmx25mm x 1mm thick in square pattern of grid size 600mmx 600mm. The GI frame work is supported from the ceiling with the help of galvanised iron hook and galvanised iron wire or 6mm dia mild steel rods to maintain proper level etc. The GI frame work on wall side shall be supported with GI angel of size 25mmx25mmx1.5mm thick complete all as specified and directed by Engineer-in-Charge and manufacturer instructions. Make of PVC Ceiling : Rajshree / Sintex/ Polycon
Taking down cement plaster of any description from brick walls or concrete surfaces of walls and ceiling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for 15 mm thick rendering in cement mortar (1:6) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-Charge.
M&L for 15 mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of cement primer including 1mm thick acrilic wall putty complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surface of walls and applying two coats of cement based paint over one coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old plastered surfaces of wall by complete removing old treatment and applying two coats of distemper oil emulsion over a coat of cement primer including 1mm thick acrilic wall putty complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old plastered surfaces of wall by complete removing old treatment and applying two coats of cement based paint over one coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for glazed ceramic coloured tiles 300mmx200mmx7mm thick as in vertical surface on walls set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 10mm thick rendering in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
S&F for non skid coloured ceramic tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge
M & L for 25mm thick plain cement concrete (1:2:4) type B-0 using 12.50mm graded stone aggregate as in floors finished even and fair complete all as specified and directed by Engineer-in-Charge.
S&F for non skid coloured ceramic tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge
M&L for 25mm thick green/black marble machine cut as in vertical surfaces such as skirting/ dado, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slabs laid over and including 10mm thick rendering in CM 1:3 including rubbing, polishing also moulding edges complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each complete all as specified & directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each complete all as specified & directed by Engineer-in- charge.
Cutting holes into brick wall for inserting hold fast etc built in CM n exc half brick wall and making good in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in- charge.
M&L for cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as for doors/ windows, bed blocks, coping , splash stone, filling of chowkhats etc including necessary form work complete all as specified and directed by Engineer-in-Charge .
S&F Anodised aluminium frame for doors, windows with one or more rebates including joining cleat for fixing etc. including powder coating (minimum thickness of powder coating shall be 50 micron as per the specification) complete all as specified and directed by Engineer-in-Charge. Make of aluminium section: Jindal/Nalco/Hindalco
S&F powder coated aluminium doors shutters aluminium sections weighting 0.55 Kg/RM (minimum thickness of powder coating shall be 50 micron) including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws complete all as specified and directed by Engineer-in-Charge. Make of aluminium section: Jindal, Hindalco, NALCO
S&F anodised aluminium windows and ventilator shutters, side hung type, without sash bars aluminium section weighting 0.55 Kg/RM (minimum thickness of powder coating shall be 50 micron) including necessary jointing cleats, glazing clips, anodised aluminium snap beading, screws including aluminium grill “(Approx weight not less then 1.0Kg/Sqm), anodised aluminium fitting such as peg stay 150mm long (1 No), hinges type B21 100mm size (2 Nos), suitable handle (1No) complete all as specified and directed by Engineer-in-Charge. Make of aluminium section: Jindal/Nalco/Hindalco
S&F Fibreways Brand Fiber Glass Reinforced plastic (FRP) Door Frames of three legged of cross section 90mmx45mm having single rebate of 32mmx15mm to receive shutter of 30 mm thickness. The laminate door frame molded with fire retardant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiberglass from all sides. M S Stay shall be provieded at the bottom to steady the frame complete all as specified and directed by Engineer-in-Charge.
S&F Fibreways Brand 30mm thick Glass Fiber Reinforced Plastic (FRP) Paneled door shutter of required coloured and approved brand and manufacture,made with fibre retardant grade unsaturated polyster resin moulded to 3mm thick FRP laminate for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings,cast monolithically with 5mm thick FRP Laminate for panels and conforming tp IS 14856-2000 complete all as specified and directed by Engineer-in-Charge
S&F 150mm long aluminium, anodized barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge
S&F 125mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed by Engineer-in-Charge
S&F 100 mm mild steel cold rolled butt hinges complete all as specified and directed by Engineer-in-Charge
S&F in repair, 10 ltr capacity low level PVC valveless, syphonic action type flushing cistern, white, with inlet, ball valve, flush pipe, float and handle incl bracket. complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china wash down water closet pan (padestel pattern) white complete including plastic seat cover with mild steel chromium plated hinging device complete all as specified and directed by Engineer-in-Charge.
S&F in repair for vitreous china wash basin white, flat back size 550x400mm with pedestal including brackets incl cutting for and pinning in end of brackets or erecting stand etc complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia pillar taps cast copper alloy with capsten heads and chromoium plated screwed down high pressure with or without lettered HOT or COLD with long screwed shanks and flynut screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm dia fancy type pillar taps (elbow operated type) cast copper alloy with capsten heads and chromoium plated screwed down high pressure with or without lettered HOT or COLD with long screwed shanks and flynut screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair, 15mm bore stop valves, cast copper alloy screwed down, high pressure wih crutch or butterfly handles, screwed both ends complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm bore bib taps cast copper aloy fancy type chromium plated with crutch or butterfly handles, screwed down complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
S&F Vitreous china laboratory sink, white,flat back, size 600x450x200mm (for Hospital use) excluding taps, chain and plug and porcelain stopper but including brackets, waste pipe & coupling, bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm dia bib tap cast copper alloy, with crutch or butterfly handles, screwed down, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F towel rail CP 600mm long 25mm dia complete all as specified and directed by Engineer-in-Charge.
S & F for soap dish 100mm dia round or oval complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15mm dia, steel tubing & connections including cleaning for refining or removal to store complete all as specified and directed by Engineer-in-Charge.
Taking up or down 20mm dia, steel tubing & connections including cleaning for refining or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F steel water tubing galvanised 15mm bore, medium grade fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 50 here-in-before but fixing only old mild steel tubes with new fittings complete all as specified and directed by Engineer-in-charge.
S&F steel water tubing galvanised 20mm bore, medium grade with all fittings fixed to wall and ceiling or in floor complete all as specified and directed by Engineer-in-charge.
All as per Ser item No 52 here-in-before but fixing only old mild steel tubes with new fittings complete all as specified and directed by Engineer-in-charge.
M&L for cuting chases for conceled water tubing and making good in CM (1:3) cutting not ec 10 cm girth complete all as specified and directed by Engineer-in-charge.
M&L 100 mm internal dia cast iron sand cast soil, waste and vent pipes in any length with or without ears, with cement joints laid in trenches complete all as specified and directed by Engineer-in-charge.
Dismantling, disconnecting existing water tank of capacity exc 500 litres but not exceeding 1000 Ltrs all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tank (cylindrical vertical triple layered white colour with closed top) hoisted and fixed in position of capacity 1000 litres including 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 0.20 metre long fitted with brass anti-mosquito net coupling at the end of over flow pipe & 15mm bore GI air vent pipe 0.20 metre long fitted with tee at the end of air vent pipe (all GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) complete all as specified and directed by Engineer-in-Charge.
M&L hard core broken bricks of gauge not exc 63 mm deposited spread and levelled inn layer not exc 15 cm thick watered and rammed to a true surface using broken brick bats omplete all as specified and directed by Engineer-in-Charge. .
M&L 75 mm thick PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in plinth protection omplete all as specified and directed by Engineer-in-Charge.
S&F mild steel work (flat iron) for wind ties for roof including for securing bolts complete all as specified and directed .
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed by Engineer-in-Charge.
M&L for provinding reinfored cement concrete (1:1.5:3) B-1 as in slab supported on walls, beams and columns in floors, roofs, landing and like complete all as specified and directed by Engineer-in-Charge.
M&L for form work to side & soffits of suspended slab supported on wall for rough finish surface for thickness n exc 200 mm complete all as specified and directed by Engineer-in-Charge.
S & F for Mild Steel TMT bars 8mm dia and over cut to length, bent to shape required including bending, cranking spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in- charge.
M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of dry distemper over a coat of chalk whitening complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moss and efflorescent salts and applying one coat of dry distemper complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moss and efflorescent salts and applying one coat of cement base paint complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old painted wood and wood base surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed by Engineer-in-Charge.
S&F mild steel work, framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and complete conforming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in- charge.
Erection and fixing only steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 Grade St-240 complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new steel surface over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L for 6mm thick AC sheets (corrugated, semi corrugated) in roof fixed with L type, J type or cranked bolt complete all as specified and directed by Engineer-in- charge.
M&L for 6mm thick AC sheets one piece plain angular ridge fixed with L type, J type or cranked bolt complete all as specified and directed by Engineer-in- charge.
Excavation over areas not exceeding 1.50 metre deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 1 above but depth exceeding 1.5 metre but not exceeding 3.0 metre complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 150 mm thick(1:4:8) type D2 using 40mm graded stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed by Engineer-in-charge .
Material and labour for brick work using subclass 'B' bricks (old size bricks) laid on edge in floors bedded and jointed in cement mortar (1:6) including flush pointing in cement mortar 1:3 complete all as specified & directed by Engineer-in- charge.
Material and labour for brick work using subclass 'B' bricks (old size bricks) straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:3) complete all as specified & directed by Engineer-in- charge.
Material and labour for flush pointing brick walls in cement mortar 1:4 on brick work of drain etc complete all as specified & directed by Engineer-in- charge.
M & L for PCC (1:2:4) type B2 using 40mm graded stone aggregate as in in walls or retaining walls boundary pillars and post complete all as specified and directed by Engineer-in-charge .
Material and labour for brick work in wall using subclass 'B' bricks (old size bricks) straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified & directed by Engineer-in- charge.
M&L 50 mm thick PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as floor finish omplete all as specified and directed by Engineer-in-Charge.
S&F Mild steel framed work as in grills, grating, railings etc with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railing, frame work for water tanks and similar work conforming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including fittings such as switches, ceiling roses, pendent holders, light fittings any type, sockets, regulators etc and making good disturbed surfaces of walls and floors etc to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring complete with 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable drawn in and including concealed regid PVC conduit including provision of 1.2mm thick pressed steel sunken terminal boxes 60mm deep, suitable length and painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5 Sqmm PVC insulated solid / multi standard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point controlled by one switch, bell push or one fan point controlled by one switch complete including making good to disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 89 here in before, but for one switch socket combination 5/6 Amps on independent board.
All as per Srl item No 89 here in before, but for one 3 pin socket outlet 5 Amps on same board with other switches
All as per Srl item No 89 here in before, but with multi-stranded copper conductor FRLS PVC unsheathed cable of cross sectional area 2.5 Sqmm for one switch socket combination 6 pin, 15 Amps on independent board including 2.5 Sqmm PVC insulated solid / multi standard copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush type single pole one way 5/6 Amps, 230 volts complete all as specified & directed by Engineer-in- charge.
S&F Switch socket combination 5 pin, 5/6 Amps, flush type complete all as specified & directed by Engineer-in-Charge.
S&F Switch socket combination 6 pin, 5/16 Amps, flush type complete all as specified & directed by Engineer-in-Charge.
S & F bell push flush type 5/6 Amps 230 volts complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 5 pin, 5 Amp flush type complete all as specified & directed by Engineer-in- charge.
S&F electronic bell ding dong type, AC 230 Volt single pole complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose polycarbonate surface bakelite 65 x 50mm size three terminals complete all as specified and directed by Engineer-in-Charge.
&F in repair recess mounting LED 2x2 luminaire 1 x 36 watt with white powder coated CRCA housing with LEDs, Seamless front frame with flat white high transmission acrylic cover including electric connection surge protector connecting with using flexible copper wire twin core 23/0.2mm upto ceiling rose/connector, including taking down unserviceable old fitting any type complete all as specified and directed by Engineer-in-Charge complete conforming to Make : Havells CAT Part No. VENUSNEOHE 2X2PLR36W LED 8NS or equivalent in Philips / Bajaj
upply and fixing in replacement Baton integrated LED channel 1 x 18 watt LED (4 feet long) (Integral sleek extruded aluminium LED channel with white acrylic cover ) tube light fitting wall mounted complete with rod, driver and all other accessories including electric connection connecting with using flexible copper wire twin core 23/0.2mm upto ceiling rose/connector, including taking down unserviceable old fitting any type complete all as specified and directed by Engineer-in-Charge. Make : BCLSB 18 WH of Bajaj / LHEXBPL71N1W018 Havells or equivalent make as specified
Supply and fixing stepped electronic regulator 400 watt (flush type) for ceiling fan on the existing phenolic laminated sheet etc as required complete all as specified by Engineer-in-charge.
S&F factory made sheet metal enclosure for double door distribution board with epoxy powder coated surface mounted SP & N 8 way, protection class IP-43 suitable for mounting MCB, conforming to IS-8623, BS-5484 with 200 Amps rated copper bus bar stove enameled dust and vermin proof suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in-Charge. Make : Indoasian / C&S / Legrand
S&F factory made sheet metal enclosure for double door distribution board with epoxy powder coated surface mounted VTP&N 4 way, protection class IP-43 suitable for mounting and including MCCB, 160Amp conforming to IS-8623, BS-5484 with 200 Amps rated copper bus bar stove enameled dust and vermin proof suitable for working on 415 volts AC supply complete all as specified & directed by Engineer-in-Charge. Make : Indoasian / C&S / Legrand
S&F factory made sheet metal enclosure for double door distribution board with epoxy powder coated surface mounted SP & N 4 way, protection class IP-43 suitable for mounting MCB, conforming to IS-8623, BS-5484 with 200 Amps rated copper bus bar stove enameled dust and vermin proof suitable for working on 240 volts AC supply complete all as specified & directed by Engineer-in-Charge. Make : Indoasian / C&S / Legrand
S&F MCCB TPN 63 Amps with breaking capacity 25 KA, fixed TM and 415 Volts AC supply, ISI marked complete all as specified and directed by Engineer-in-Charge. Make : HAVELLS / LEGRAND / INDO ASIAN
S&F MCB 'B' Series 05 to 30 Amp, 240 volts, single pole with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed by Engineer-in-Charge. Make : Indoasian L&T / Legrand
S&F MCB 'B' series 5 to 30 Amp, 240 volts, SP & N with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and directed by Engineer-in-Charge. Make : Indoasian L&T / Legrand
S&F in replacement of sub-main wiring with two runs of single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn into and including 20mm PVC concealed medium grade conduit, including one run of 6 Sqmm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in panel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with top edge of earth plate at a depth not less than 1.5 Mtr below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts and washers of galvanized iron or steel and thimbles upto equipment and other end of the earth wire connected to earthing test point and protected by galvanized iron pipe light grade 20mm dia upto earthing test point / equipment fixed with 2 Nos. of mold steel clamps made out of 25mm x 3mm flat iron and preforated water pipe 20mm dia galvanized iron pipe heavy grade 2.25 Mtr long and top with socket and plug and bottom connected to earth plate by silt and two bolts / nuts / washers complete with funnel and wire mesh, PCC chamber in cement concrete (1:3:6) type C-1 and cast iron cover with frame all as shown on electrical plate No. 3 of MES Schedule Part - I of SSR-2009 complete all as specified and directed by Engineer-in-Charge. Note : (i) Outer edge of earth pit will be 1 Mtr away from the outer edge of PCC Chamber. (ii) Galvanized iron earth wire 4mm dia upto earthing test point / equipment is encluded in this item. (iii) Water pipe shall be provided in slainting position. (iv) 20mm dia galvanized iron pipe for watering shall be provided with a socket and plug and shall be 10cm above the ground level.
S&F pressure die cast aluminium housing LED security light luminaires 25 watts, 6000k clear transperant acrylic cover with IP66, grey colour and fixting to wall/ on pole including fixing arrangement with suitable galvanized iron pipe 40mm boe light grade brackets 2 mtr length bent to shape required including clamps, buts/ bolts/ washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer-in-Charge. Make : Havells / Crompton / Bajaj / Wipro.
Supply, fixing, testing and commissioning of Double Dome LED Surgical Light (United) USI LED 48D incl single non winged round shape lamp head without any slots for easy maintenace and better sealing against dust and fumigation (diameter of lamp head for main dom 600mm) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED 'Duranto' highbay luminaire 80W having fin ventilation technology for better thermal management and its cutting edge LED technology seeks to various industrial application Make : Bajaj Cat part No BGHB80W complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing and commissioning in replacement of 06 sqmm, 2 core XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 volts grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles/wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earth work, sand cushioning and brick protection required for item shall be measured and paid separately under respective items of BOQ.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out including taking out old brick or precast cable cover for reuse complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
M & L for sand cushioning with dry coarse sand to under ground cable around the cable after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
Supply and fix GI pipe 20 mm bore light grade for protection of cable including provision of clamps, nuts, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all as specified and directred by Engineer-in-Charge.
S&F of sub-main wiring with two runs of single core cables PVC insulated and un-sheathed 4 sqmm (Nominal Area) FRLS stranded copper conductor drawn into and including 20mm Non metalic PVC concealed medium grade conduit, including one run of 4 Sqmm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in panel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 4 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F of sub-main wiring with two runs of single core cables PVC insulated and un-sheathed 2.5 sqmm (Nominal Area) FRLS stranded copper conductor drawn into and including 20mm Non metalic PVC concealed medium grade conduit, including one run of 2.5 Sqmm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in panel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 2.5 Sqmm single core cable and one run of 2.5 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
Taking down existing ceiling fan/ exhaust fan of any size and Hanging/ refixing after fixing of the new hanging rod and making electric connections with 0.60RM long flexible cable of size 23/0.0076 mm complete all as specified and directed by the engr-in-charge.
M&L for painting of existing of ceiling fan any size complete in situ with synthetic enamel paint by spraying inluding filling cavities with filer one coat after cleaning all dust and change of capacitor complete all as specified and directed by the engr-in-charge.
Supplying and laying for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed by Engineer-in-Charge -------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,81,548.50 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 30 & 31(R)(R) (Schedule of Credit) of Tender document
M/S BUDHRAM BISHNOI
M/S KARNI CONSTRUCTION COMPANY
Gyan Chand Marothia Engineer Contractor And Suppliers
M/s Balvinder Singh Engineer and Contractors
Aggarwal brothers and company
M/s MITTAL CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .