Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹26.9 L+₹92,900 (3.58%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹27.6 L+₹1.6 L (6.23%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹28.9 L+₹2.9 L (11.1%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹30.4 L+₹4.4 L (16.9%)Rejected-Finance 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Sept 2022, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
REPAIRS RE WIRING AND REPLACEMENT OF CONVETIONAL LIGHTS WITH LED TUBE LIGHTS CEILING LIGHTS AND CONNECTED REPAIRS AT VARIOUS LOCATION AT HQ CAFVD ARSENAL DEPOT AND MISCELLENEOUS BUILDINGS UNDER AGE EM II IN GE CENTRAL KIRKEE
2022_MES_545876_1
8683/E8 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CAFVD area
Class D Category b(i)
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹90,000
Yes
27 Sept 2022
17 Aug 2022
8 Sept 2022
17 Aug 2022
6 Sept 2022
1 Sept 2022
17 Aug 2022 - 31 Aug 2022
Amount
NOTE :- Contractor has to submit two years manufacturer's Guarantee certifcate from the certified date of completion for all the light fittings catered in this BoQ.
Taking down existing unserviceable aluminum / copper point wiring of any description and in any position including all fittings and making good the disturbed surface to match with the existing surfaces complete all as specified and as directed.
Material and labour for point wiring in PVC conduit of suitable size but not less than 20mm dia including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sq.mm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sq.mm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and including PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and as directed.
All as per Srl Item No 3 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl Item No. 3 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Srl Item No 3 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amps on independent board using 2.5 sq.mm two run and one run 2.5 sq.mm (nominal area) stranded copper conductor cable.
Material and labour for point wiring in casing & caping of suitable size but not less than 20mm size including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sq.mm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sq.mm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and including PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge.
All as per Srl Item No. 7 above but one bell/buzzer point controlled by one push button on independent with cables1.5 sq.mm size.
All as per Srl Item No. 7 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl Item No. 7 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Srl Item No. 7 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amps on independent board using 2.5 sq.mm two run and one run 2.5 sq.mm (nominal area) stranded copper conductor cable.
Material and labour for point wiring for one light / fan / bell point controlled by one switch in steel conduit with all steel enamelled fittings such as elbow bends, junction boxes, supporting clamps for proper hanging arrangements made out from 20x1mm flat aluminium patti including nuts, bolts and bending to shape etc. of appropriate size but not less than 20mm on surface with two run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sq.mm nominal cross sectional area 1100 volts grade and including one run of 1.5 sq.mm (green colour) PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire including suitable size sunken type Galvanised pressed sheet steel 1.6 mm thick terminal box of suitable size with 3 mm thick laminated hylam sheet for mounting switches, sockets etc. and making good the disturbed wall and painting the same with matching colour of the existing wall, all as specified and as directed.
All as per Srl Item No. 12 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl Item No. 12 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Srl Item No. 12 above but point wiring for one five pin switch socket outlet combination, 15 Amps & 5 Amps (independent) with using 2.5 sq.mm two run and one run 2.5 sq.mm (nominal area) stranded copper conductor.
Supply and fix switch flush type, 5 Amps, single pole, one way, 230 volts AC circuit complete all as specified as directed.
Supply and fix switch flush type, 5 Amps, bell push, flush type, 230 volts AC circuit complete all as specified and as directed.
Supply and fix socket outlet, five pin, 5 Amps, flush type, multipurpose, 230 volts AC circuit complete all as specified and as directed.
Supply and fix switch flush type, 15 Amps, single pole, one way, 230 volts AC circuit complete all as specified and as directed.
Supply and fix Socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type, 230 volts AC circuit complete all as specified and as directed.
Supply and fix ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified and as directed.
Supply and fix in replacement of stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50 Hz supply, 100 Watt complete all as specified and as directed.
Dismantling and taking out old unserviceable copper/aluminium sub main wiring / unarmoured cable (used as sub main wiring) from any height of any size and core with all connecting accessories including conduit or casing caping and including making good to the disturbed wall and painting the same with matching paint as of existing wall including material all as specified and as directed by Engineer in charge.
Material and labour for sub main wiring at any height with two single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sq.mm, 1100 volts grade conforming to IS drawn through and including new 20 mm dia steel conduit and including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sq.mm FRLSH green in colour as contineous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and as directed.
Material and labour for sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 sq.mm, 1100 volts grade, drawn through and including new PVC non metallic conduit 20 mm dia including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sq.mm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and as directed by Engineer in charge.
Material and labour for sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 sq.mm, 1100 volts grade, drawn through and including casing caping including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sqmm, 1100 Volts grade green in colour as earth contuinity wire all as specified and as directed by Engineer in charge.
Material and labour for sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 6.0 sq.mm, 1100 volts grade, drawn through and including casing caping including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sq.mm, 1100 Volts grade green in colour as earth contuinity wire all as specified and directed by Engineer in charge.
Dismantling and drawing out old unserviceable sub main aluminium / copper wiring from existing steel / PVC conduit of any size and any type from any height with all connecting accessories (excluding conduit or casing caping) and making good the disturbed wall and painting the same with matching to existing wall including material all as specified and directed by Engineer in charge.
Material and labour sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 1.5 sq.mm 1100 volts grade conforming to IS drawn through existing Steel/ PVC conduit including 1.5 sq.mm PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and as directed.
Material and labour sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 2.5 sq.mm 1100 volts grade conforming to IS drawn through existing Steel/ PVC conduit including 2.5 sq.mm PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and as directed.
Material and Labour for Sub main wiring at any height with four single core PVC insulated copper conductor cable (FRLSH) of size 6 sqmm 1100 volts grade conforming to IS drawn through existing Steel / PVC conduit including two single core 6.0 sqmm PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and as directed. NOTE FOR Sl ITEM No 28 to 31 :- Two / four runs of wiring cable and one/two runs of earth continuity wire shall be measured as one length for payment purpose.
Disconnecting and taking down old existing damaged metallic rigid steel conduit of any size and any type from any height with all fittings complete all as specified and as directed.
Supply and fix hot galvanised rigid steel conduit 25 mm dia, light grade, at any height with and including of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing , conduits etc. to walls,ceiling, steel joists etc. complete all as directed.
Supply and fix hot galvanised rigid steel conduit 20 mm dia, light grade, at any height with and including of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing , conduits etc. to walls,ceiling, steel joists etc. complete all as directed.
Disconnecting and taking down old distribution box with MCB / fuse grip, TPN/SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position and making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and as directed by Engineer in charge.
Supply, fix, connecting and testing of VTPN DB of 12 way suitable for MCCB up to 160 Amps as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09, conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint by preventing rusting. DB shall be with Insulated busbar with withstand capacity of 36 KA, shrouded neutral bar, door earthing, corner safe. wire sets, shrouded neutral bar, earth bar & wire ties all as per Legrand Cat.No. 507748 or equivalent makes in Schneider / L&T complete all as specified and as directed. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule.
Supply, fix, connecting and testing of VTPN DB of 8 way suitable for MCCB up to 160 Amps as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09, conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint by preventing rusting, DB shall be with Insulated busbar with withstand capacity of 36 KA, shrouded neutral bar, door earthing, corner safe, wiresets, shrouded neutral bar, earth bar & wire ties, all as per Legrand Cat.No. 507745 or equivalent in Schneider- Acti-9/ L&T-Exora all as specified and as directed. NOTE:- MCCB, MCB will be measured and paid separately under relevant item of this schedule.
Supply, fix, connecting and testing of VTPN DB of 4 way suitable for MCCB up to 160 Amps as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09, conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint by preventing rusting. DB shall be with insulated busbar with withstand capacity of 36 KA, shrouded neutral bar, door earthing, corner safe, wiresets, shrouded neutral bar, earth bar & wire ties, all as per Legrand Cat.No. 507745 or equivalent in Schneider- Acti-9/ L&T-Exora all as specified and as directed. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule.
Supply, fix, connecting and testing SPN DBs of 8 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09, conforming to IEC 61439-3 & made of high quality CRCA sheet, shall have integrated door earthing system, reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint by preventing rusting, DB shall be with insulated busbar with withstand capacity of 10KA, shrouded neutral bar, door earthing, corner safe. wiresets, shrouded neutral bar, earth bar & wire ties, all as per Legrand Cat.No. 507611 or equivalent in Schneider/L&T all as specified and as directed.
Supply, fix, connecting and testing SPN DBs of 12 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09, conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint by preventing rusting, DB shall be with insulated busbar with withstand capacity of 10KA, shrouded neutral bar, door earthing, corner safe, wiresets, shrouded neutral bar, earth bar & wire tiesall as per Legrand Cat.No. 507612 or equivalent in Schneider/L&T all as specified and as directed.
Supply and fix, thermal magnetic adjustable MCCB 160 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as per Legrand-DPX3 cat No 420057 / Schneider-NSX/L&T all as specified and as directed
Supply and fix, Thermal magnetic adjustable MCCB 100 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as per Legrand-DPX3 cat No 420057 / Schneider-NSX/L&T all as specified and as directed
Supply and fix, Thermal magnetic adjustable MCCB 63 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as per Legrand-DPX3 cat No 420057 / Schneider-NSX/L&T all as specified and as directed
Supply and fix MCB 40 to 63 Amps, TP "C" curve 10 KA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and directed. MAKE :- Legrand/ABB/L&T/ Seimens.
Supply and fix MCB 6 to 32 Amps, single pole and neutral, "C" curve 10 KA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and directed. MAKE :- Legrand/ABB/L&T/ Seimens.
Supply and fix MCB 6 to 32 Amps, single pole, 10 KA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, complete all as specified and as directed. MAKE :- Legrand/ABB/L&T/ Seimens.
Removing of old HPMV / MH high bay light fittings at 12 to 15 mtr height carefully without dammaging connector or ceiling rose. If any damage made to the government property the same shall be repaired by the contractor without any extra cost complete all as specified and as directed.
Supply and fix at 5 to 9 mtr height,150W industrial LED highbay luminaire with >120Lm/W, powder coated PDC Aluminium body & optical lenses, toughned glass difuser with complete all accessories having IP 66 degree of protection, power factor >0.95,THD<10%, potted driver, internal surge protection-4KV & external surge protection-10KV, LED source make Cree,Osram including safety chain with i bolt complete all as specified and directed by Engineer-in-Charge. MAKE :- Wipro/Crompton / philips/ bajaj. NOTE :- The quoted rates are deemed to be included the cost of Nut-bolts washars or clamps required to be replaced if old one are found unserviceable.
Removing of old main switch after disconnecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 25 KA 63 Amps all as per Legrand Cat No 420053 /L&T /ABB with one way metal enclosure Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nut bolt etc including making good the disturbed suface of wall including material complete all as specifide and as directed.
Removing of old main switch after disconnecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 25 KA 100 Amps all as per Legrand Cat No 420055 /L&T /ABB with one way metal enclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nut bolt etc including making good the disturbed suface of wall including material complete all as specifide and as directed.
Removing of old main switch after disconnecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 25 KA 160 Amps all as per Legrand Cat No 420057 /L&T /ABB with one way metal enclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nut bolt etc including making good the disturbed suface of wall including material complete all as specifide and as directed.
Removing of old main switch after disconnecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 25 KA 200 Amps all as per Legrand Cat No 420057 /L&T /ABB with one way metal enclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nut bolt etc including making good the disturbed suface of wall including material complete all as specifide and as directed.
Removing of old main switch after disconnecting the incoming and out going cables, supply and fix Industrial plug and socket board TP 32 Amps including plug top and MCB "C" curve 10 KA 32 Amps all as per Legrand Cat No 5078 18 and 4086 58 /L&T /ABB and making conections of cables with suitable size of nut bolt etc including making good the disturbed suface of wall including material complete all as specifide and as directed.
Removing of old main switch after disconnecting the incoming and out going cables, supply and fix one way metal inclosure all as per Legrand Cat No 5077 93 /L&T/ABB and MCB "C" curve TPN 10 KA 32Amps all as per Legrand Cat No. 4086 80 /L&T/ ABB and making conections of cables with suitable size nut bolt etc. including making good the disturbed suface of wall including material complete all as specified and as directed.
Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven single phase including MCB 'C' series SP 20 Amps and supplied with neutral links complete all as specified and as directed.
Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven three phase including MCB 'C' series TP 20 Amps and supplied with neutral links complete all as specified and as directed.
Dismantling and taking down unserviceable any light fitting from any location/height after disconnecting of electrical connection complete including all connected accessories all as directed by Engr-in-Charge.
Supplying, fixing, connecting up to existing/new ceiling rose and testing industrial box type batten with precoated CRCA body. LED tube light fitting suitable for and including 1x20 W 4 feet long tube with polycarbonate diffuser ,LED lamp efficay -110 Lum/W ,THD ≤15% with operating voltage range 100-300V, driver efficency >85%, surge voltage withstand 2.5 KV , power factor ≥0.9 including all accessories for fixing on steel trusses / false ceiling all as specified & directed. MAKE:- Crompton Cat No-IGP161LT8-16 & LT8-20-865 or equivalent in Bjajaj / Philips / Havells
Supplying, fixing, connecting in at any height up to existing/new ceiling rose and testing LED luminarie made up of precoated CRCA housing provided with cum reflector finished in white powder coating, completely prewired with accessories up to terminal block suiatble for 2x 20W 4 feet long LED tubes(High Lumen-110 Lumen/Watt) including fixing arrangements for fixing on steel trusses / false ceiling all as specified & directed. MAKE :- Crompton Cat No IGP162LT8-16 & LT8-20-865 or equivalent in Bjajaj / Philips / Havells
Supplying, fixing, connecting in at any height up to existing/new ceiling rose and testing LED inverter batten with 20 W LED light source in integral module with polycarbonate/Acrylic diffuser more than 85%efficiency of light with LED lamp efficay as 110 Lum/W THD ≤15% with operating voltage range 100-300V, driver efficency >85%, surge voltage withstand 2.5 KV , power factor ≥0.9, fittings conection complete all as specified & directed. NOTE - Quoted rate is deemed to be inclusive of any misc materials required for fixing new luminaries. MAKE :- Crompton/bajaj/philips
Supplying, fixing and connecting up to existing/new ceiling rose and testing 12W 6500K LED recessed mounting round down light fittings with PDC aluminium body, CRI > 80 beam angle 36 degree including suitable LED driver and connecting to existing/new ceiling rose and including mounting accessories complete all as specified and as directed by Engineer in charge. MAKE :- Crompton Cat No-CDR212-12-40-SL-NWH or equivalent in Bjajaj / Philips / Havells
Supplying, fixing and connecting up to existing/new ceiling rose and testing 12W 6500K 1' x 1' LED recess mounting light fitting in grid/armstrong type ceiling including suitable LED driver and connecting with 23/0.0076 copper conductor flexible twisted two core cable to existing/new ceiling rose and including mounting accessories complete all as specified and as directed by Engineer in charge.
Supplying, fixing, connecting up to existing/new ceiling rose and testing 36 W aesthetically designed 2' x 2' LED recess mounting light fittings in grid/armstrong type ceiling including suitable LED driver and connecting with 23/0.0076 copper conductor flexible twisted two core cable to existing/new ceiling rose and including mounting accessories complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 2.5 meters length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthling lead of 32x6 mm galvanised iron or steel strip all as shown in Plate No. 4 to the earthing test point all as specified and indicated including testing on completion including excavation and earth work of any strata, pit cover , funnel etc and connected items complete all as specified and as directed.
Supply and fix in replacement GI strip 32 mm x 6 mm to be buried in ground as earth continuity conductor to be fixed from test point to test point complete all as specified and as directed.
Dismantling and taking down existing high bay light/light fitting of any type from 9 to 15 mtr height including repairs by replacement of burnt/worn out accessories and refixing in position all as directed by Engr-in-Charge. NOTE :- (i) Accessories/material only wherever required shall be measured and paid seperately. (ii) Labour charges for taking down and refixing after repair including, minor spares like nuts, bolts and insulation materials shall be deemed to be included in the rate quoted. (iii) The maintanance/repairs of luminaries will be carried out as per requirement.
Supply only electronic internal surge protector capacity 10 KV suitable for different type and diferent make LED street / flood lights as per old / existing makes like C&S,Havells, HPL, Bajaj, Crompton etc. fixed internaly all as specified and as directed.
Supply only electronic driver suitable for 120 to 150 watt LED light fitting post top / high bay / mid bay etc of existing make of Bajaj/HPL/CG/ Wipro/philips/Havells all as specified and as directed.
Supply only electronic extenal surge protector capacity 5 KV suitable for different type of light fittings as per existing makes like C&S,Havells, HPL, Bajaj, Crompton etc all as specified and as directed.
Veekay Enterprises
metro electrical services
ONKAR ELECTRIC AND GENERAL STORE
SBS Enterprises
T.H.ASSOCIATES
M/S. Niksun Electro-Infra Private Limited
Kedar Electricals
M/S. OM ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .