GE TIRUNELVELI
Garrison Engineer Naval Post Base Vijayanarayanam Tirunelveli -627119
8632 MAINTENANCE OF WATER SUPPLY INSTALLATIONS, STP AND REPAIR/REPLACEMENT OF WATER SUPPLY PIPE LINE AND ITS CONNECTED ITEMS AT SESS PALAYAMKOTTAI UNDER GE TIRUNELVELI
2026_MES_796629_1
GE/TVL/8632/E8 of 2026-27
Open Tender
Civil Works
Item Rate
270 days
Palayamkottai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
₹51,200
Yes
30 Oct 2026
30 Oct 2026
23 Nov 2026
30 Oct 2026
20 Nov 2026
13 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for taking up submersible pump set 7.5 HP 3-phase 415v,50Hz from Deep wells, AC, opening the motor, cutting and removing the burnt windings, cleaning the starter and rotor with cleaning agent. rewinding the motor with appropriate gauge of super enameled copper wire of approved make insulating the winding with same class of insulation and refixing at the same location complete all as specified and directed. | 4 | Each Job | - | - |
| 2 | Material and labour for taking up Fountain pump set 7.5 HP 3-phase 415v,50Hz, AC, from Fountain opening the motor, cutting and removing the burnt windings, cleaning the starter and rotor with cleaning agent. rewinding the motor with appropriate gauge of super enameled copper wire insulating the winding with same class of insulation and repairing the pump portion by checking and replacing any damaged gasket etc and refixing at the same location complete all as specified and directed. | 1 | Each Job | - | - |
| 3 | Material and labour for taking out Pump set 5HP 3-phase 415v,50Hz, AC, opening the motor, cutting and removing the burnt windings, cleaning the starter and rotor with cleaning agent. rewinding the motor with appropriate gauge of super enameled copper wire insulating the winding with same class of insulation and repairing the pump portion by checking and replacing any damaged gasket etc and refixing at the same location complete all as specified and directed. | 2 | Each Job | - | - |
| 4 | Material and labour for taking out Pump set 3 HP 3-phase 415v,50Hz, AC, opening the motor, cutting and removing the burnt windings, cleaning the starter and rotor with cleaning agent. rewinding the motor with appropriate gauge of super enameled copper wire insulating the winding with same class of insulation and repairing the pump portion by checking and replacing any damaged gasket etc and refixing at the same location complete all as specified and directed. | 3 | Each Job | - | - |
| 5 | Material and labour for spray Painting of motor/ pump, Two coat enameled paint before one coat of red oxide paint including scraping and writing MES/SM No. complete all as specified and directed of the 7.5/5/3 HP capacities. | 4 | Each Job | - | - |
| 6 | Excavation in trenches for laying of CPVC water tubing etc., getting out in soft/loose soil n.exc 1.5m wide and n.exc 1.5m depth complete all as specified and directed. | 36.5 | Cum | - | - |
| 7 | Returning, filling in trenches including spreading, leveling, watering and in layers n.exc 25cms thick without damaging pipes/special fittings as in any type of soil complete all as specified and directed. | 32.1 | Cum | - | - |
| 8 | Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. | 4.4 | Cum | - | - |
| 9Material and labour for repair/check Pump starter Panel by disconnecting the electric supply and finding out defects and replacing the existing damage items such as bus bar, timer ,power contactor , relay, start stop push button, for the starter panel of for the following capacity of electric motor/ pump complete all as specified and directed. | |||||
| 9.01 | motor/ pump of capacity 7.5HP 415V , 50 HZ | 6 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
8632TENDERDOCS.pdf
Tender Documents • 0.74 MB
BOQ_893532.xls
BOQ • 1.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .