Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC | ₹1.4 L | L1 | Accepted-AOC Award of Contract |
| 2 | L2₹1.8 L+₹39,600 (27.8%)Rejected-Finance 23609 A INDERJEET SINGH BATH MANSA ROAD NEAR I T I CHOWK BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | ₹1.8 L+₹39,600 (27.8%) | L2 | Rejected-Finance Higher than lowest Bidder |
| 3 | L3₹2.7 L+₹1.3 L (91.0%)Rejected-Finance | ₹2.7 L+₹1.3 L (91.0%) | L3 | Rejected-Finance Higher than lowest Bidder |
| 4 | L4₹3.2 L+₹1.8 L (123.3%)Rejected-Finance 36 RANJEET NAGAR SHAHBAD MARKANDA NH 1 KURUKSHETRA HARYANA 136135 | KURUKSHETRA | HARYANA | 136135 | ₹3.2 L+₹1.8 L (123.3%) | L4 | Rejected-Finance Higher than lowest Bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical as per tender documents |
Tender Value
₹3.3 L
Closing Date
19 Dec 2024, 9:00 amClosed
GE (P) Bikaner
GE (P) Bikaner Bikaner Mil Stn Bikaner-334001
Soil Investigation for Job No MWP SWC 04 2024 2025 Demolition and reconstruction of Single Living Accn of INF BN
2024_MES_687350_1
3004/Q/01/2024-25/E3
Open Tender
Civil Works
Works
90 days
GE (P) Bikaner
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
6 Jan 2025
6 Dec 2024
21 Dec 2024
6 Dec 2024
19 Dec 2024
6 Dec 2024
Amount
Soil investigation shall be carried out as per IS-1892 Bore hole dia shall be 150mm. Depth of bore shall be decided as per the soil condition and may be taken 15m or N value reaches 50, whichever is earlier. Note : Under this test preferably following results to be provided:
(i) Grain size analysis, identification & classification of soil:- (ii) Soil characteristics and Unit weight (bulk density), natural moisture content, liquid limit, plastic limit, shrinkage limit, plasticity index, specific gravity, (iii) Value of cohesion and angle of internal friction and Dry penalty, degree of saturation of soil. (iv) Free swelling index & swelling pressure if expansive soil is encountered. (v) Shear parameters (C-Φ analysis). (vi) Consolidation test & permeability test. (vii) Depth of water label below ground level. (viii) Presence of loose soil, if any and its depth. (ix) If weak soil with lesser N value as specification in table 1 of IS 1893 (part) 2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified. (x) SPT test shall be done at 1.0m interval. (xi) Recommendation for filling under floor and filling under protection including plinth protection. (xii) For open foundation, calculation of net SBC at 1.5m, 2m, 2.5m, 3.0m, 3.50m from sheet as well as settlement criteria. SBC values shall be calculated based on C-Φ analysis as well as SPT value. Test for C-Φ analysis will be carried out at site. For calculation formula given in IS 6403 shall be used. (xiii) If pile foundation are required the depth of pile shall be mentioned and pile capacity in compression, uplift & lateral load shall be given for 300, 400, 450, 500 dia for under reamed piles & 450, 500, 550, 600mm dia for long piles. (xiv) Recommendation regarding type of foundation to be adopted & net SBC/pile capacity to be adopted. Also recommendation shall be give regarding stability of soil stabilization required, if any. (xv) Recommended SBC at different depths of foundation seperately for the portions with and wothout basement. (xvi) Borehole position duly marked on plan and their distance form adjacent prominent reference points. Plan size of bldgs shall also be marked in the plan. Recommendation of footing at deferent depth i.e. 1.5, 2, 2.5, 3 & 3.5 M. (xvii) SBC and its calculation based on "N" value, shear strength and settlement criteria. Bore log detail shall be as per Appx 'D' of IS 1892 N values depth wise shall also be shown in bore log details. Bore log details shall be signed by soil consultant. Details of soil profile and bore logs also required. (xviii) Colour photograph on A4 size photo paper of the site with the locations of the boreholes duly flagged should be any reference structure and the identification of the same be marked. (xix) Modulus of sub grade reaction for Raft/Mat foundation. (xx) Depth of expansive soil and its properties, if any (xxi) Undisturbed soil sample shall be collected at 1.5m interval and at change of strata.
Test for chemical charecteristics of soil in foundation at depths of 0.5m, 1.0m, 1.5m&2m for presence of salnity and other harmful chemicals if any which may affect the foundation concrete if used for RFR in foundation.
Note:- A CD containing video evidence of depth of each borehole and machinery deployed at site location will be provided which is inclusive in above quoted rate.
GEO MEDIA ENGINEERING and CONSULTANCY SERVICES PRIVATE LIMITED (BID ID -3190056)
KUNIKA GEOTECHNICAL SERVICES P. lTD. (BID ID -3188109)
Rishi Markandeshwar Engineering Consultant (BID ID -3186306)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .