Loading…
Loading…
Tender Value
₹1.8 Cr
EMD Value
₹2.4 L
Closing Date
18 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
OS/EL/C/JP
14 conditions · 3 needing a document upload
"Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or ""V"" whichever is less crores; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIII, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. "
Only such tenderer(s) who satisfy the following eligibility criteria shall be considered:- The Contractor should have valid Electrical Contractor License issue by Govt. and submit along with tender document if valid Electrical Contractor License is not submitted along with tender documents then offer will be summarily rejected.
"(a)The tenderer must have successfully completed/substentially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of the tender. (b) (i) In case of composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed/substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works , each costing not less than the amount equal to 40% of advertised value of each component of tender, ora One similar work, each costing not less than the amount equal to 60% of advertised value of each component of tender. Note: Separate completed works of minimum required values for each component can also be considered for fulfillment of technical eligibility criteria. (b) (ii) In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. Any work or set of works shall be considered to be a separate component, only when cost of the component is more than Rs. 2 crore each. The tenderer shall submit the completion certificate as per proforma given in annexure-IV-A or IV-B or IV-C as applicable or in the format containing all information as required as per the Annex. IV-A or IV-B or IV-C. Note :- Criteria for the completed work/Substantially completed has been given in the General instructions in the tender document. "Following works will be treated as similar nature of work: "Any Electrical work related to HT/LT installations."
37 conditions · 6 needing a document upload
"Mandatory in case Bid security amount is prescribed in STD Para 5.1.2 - The Bid Security shall be deposited in cash through e-payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- XXXII and shall be valid for a period of 90days beyond the bid validity period. "
In case the tenderer is (i)Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' - shall be exempted from payment of Bid security deposit and shall submit certified copy of the registration/ Valid document issued by DIPP (mandatory if applicable)
In case the tenderer is (iii) Labour Cooperative Societies - shall deposit only 50% of the Earnest Money Deposit and shall submit certified copy of the registration/ Valid document issued by the relevant Ministry/ Labour commission (mandatory if applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer shall submit the Firms's detail as per Annexure I. (Mandatory for all firms)
The tenderer shall submit the copy of certificate as per proforma given in Annexure II. & IIA(Mandatory for all firms)
The tenderer should submit the List of similar nature of works physically completed/substantially completed in all respects during last 7 years , ending last day of month previous to one in which tender is invited,(i) directly awarded by Govt./Semi Govt./Public sector undertaking / Autonomous bodies /Municipal bodies/ Railways Siding owners (ii) Public listed company having average annual turnover of Rs. 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender/ as per proforma given in Annexure-III. In case of JV firm, these details are also required for all the members of the JV firm. In case, the Secondary Component(s) has/ have been defined, the details of successfully completed works of similar nature (that defined for the Secondary Component), executed by tenderer himself / the subcontractor (fully by any one or jointly i.e. partly by tenderer and remaining through subcontractor) during last five years, shall also be submitted (for five years )
In case of composite work, having distinct components and having separate schedule for each component having value more than 2 crores, tenderer should submit a details of work of similar nature successfully completed/substantially completed during last 7 years , ending last day of month previous to the one in which tender invited and detailed in Annexure-III (Bifurcated as per components of tender schedule), as per proforma given in Annexure-III-A. (Mandatory in case of tender for composite nature of work). In case of JV firm, these details are also required for all the members of the JV firm. In case, the Secondary Component(s) has/ have been defined, the details of successfully completed works of similar nature (that defined for the Secondary Component), executed by tenderer himself / the subcontractor (fully by any one or jointly i.e. partly by tenderer and remaining through subcontractor) during last five years, shall also be submitted (for five years ).
The tenderer shall submit the Attested copy of Completion Certificate/ substentially completed of works mentioned in Standard Technical Criteria under eligibility criteria above from the Organizations with whom they worked as per proforma given in Annexure-IV-A or IV-B (If the work is substantially completed) or IV- C (if the work is awarded by Public listed Company) as applicable. (Mandatory for all firms). In case of JV firm, these details are also required for all the members of the JV firm. In case, the Secondary Component(s) has/ have been defined, the Attested copy of Completion Certificate of works executed by tenderer himself / the subcontractor (fully by any one or jointly i.e. partly by tenderer and remaining through subcontractor) during last five years, shall also be submitted.
Details of Average Annual turnover of the public listed company (company should be 500 Cr and above) issued by Chartered Accountant. These details need to be submitted as per the proforma of Annexure VIII ( Mandatory in case of completion certificate issued by public listed company as per annexure IV- C)
The copy of the documents regarding listing in the National stock exchange or Bombay stock exchange with details of status of listing as on date of opening of tender, duly self-attested. (Mandatory in case of completion certificate issued by public listed company as per annexure IV-C)
The copy of the document of incorporation/ registration of the Public listed company (should be at least 5 years prior to date of closing of tender), duly self-attested. ( Mandatory in case of completion certificate issued by public listed company as per annexure IV- C)
The copy of document regarding Person Authorized by the Public listed Company to issue such certificate, duly self-attested. ( Mandatory in case of completion certificate issued by public listed company as per annexure IV- C)
Tenderer shall also submit the relevant copy of work order, bill of quantities bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received a copy of final/last bill paid by the public listed company in support of above work experience certificate duly self-attested.(Mandatory in case of completion certificate issued by public listed company as per annexure IV- C)
The tenderer shall submit the self attested copy of the PERMANENT ACCOUNT NO. issued by the Income Tax Department.
"The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIII, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. "
"A statement showing construction works executed and payment received in any one of the previous three financial years or the current financial year (up to date of inviting tender) taking into account the completed as well as work in progress as per Annexure-XIX on the letter head of Chartered Accountant, to evaluate bid capacity of the tenderer (Mandatory for tender value more than Rs. 20 Crores). In case of JV firm details of construction works executed by each member of JV is required to be submitted"
The tenderer should submit the List of works on hand, existing commitments and balance amount of ongoing works as per proforma given in 'Annexure-V to evaluate bid capacity of the tenderer, duly verified by the Chartered accountant (Mandatory for tender value more than Rs. 20 crores)
The tenderer should submit the List of plants & Machinery available on hand (own) and proposed to be inducted/ Hired (own and hired to be given separately) for the subject work in Annexure-VI.
The tenderer should submit the List of Personnel, Organization available on hand and proposed to be engaged for the subject work in Annexure -VII.
The tenderer in the capacity of Sole Proprieter tenderer shall submit the affidavit duly executed on stamp paper and notarized as per Annexure IX. (Mandatory for Sole Proprietership Firm/ forJV firm having Sole Proprieter firm as a member)
The tenderer shall submit the Power of Attorney duly registered with registrar or notarized as per proforma given in Annexure XIV to be submitted by sole proprietor firm duly registrar with the registrar or notarized. (Mandatory for Sole Proprietership Firm , if tender documents are uploaded by any individual ,authorized by him) (Not required if tender documents are uploaded by proprietor himself).
The tenderer in the capacity of HUF shall submit the affidavit duly executed on stamp paper and notarized as per Annexure XXVI. (Mandatory for HUF firm/ for JV having HUF as a member) )
The tenderer in the capacity of HUF shall submit the Power of Attorney, duly executed on stamp paper and duly registered with registrar/ notarized as per Annexure XXVII. (Mandatory for HUF firm)( Required , if tender documents are uploaded by any individual ,authorized by him) (Not required if tender documents are uploaded by Karta himself).
The tenderer as partnership firm shall submit copy of partnership deed (duly registered with registrar or Notarized prior to the date of tender opening as per Indian partnership Act) (Mandatory for Partnership Firm /JV Firm having partnership firm as a member)
The tenderer as partner ship firm shall submit the Power of Attorney (duly registered with registrar or notarized) as per proforma given in Annexure-XIII to be submitted by Partnership firm. (Mandatory for Partnership Firm) (Required even if one or more partners are authorized in Partnership deed to sign and upload the offer on behalf of the firm.)
The tenderer in the capacity of Company shall submit the Copy of Memorandum of Association / Articles of Association of Company. (Mandatory for Company Firm / JV Firm having having Company as a member)
The tenderer in the capacity of Company shall submit the copy of resolution passed by Board of Directors authorizing its Director/Employee to deal with tender on behalf of company. (Mandatory for Company Firm)
The tenderer in the capacity of company shall submit the Copy of Certificate of Incorporation of the Company. (Mandatory for Company Firm/JV Firm having having Limited Company as a member)
The tenderer in the capacity of company shall submit the Power of Attorney/ Authorization (duly registered with registrar or notarized) including ratification clause duly signed by person authorized by the company as per proforma given in Annexure- XV. (Mandatory for Company Firm)( Required even if tender documents are submitted by the authorized/ power of attorney holder himself as per resolution passed by Board of Directors)
The tenderer in the capacity of Limited liabilities Partnership firm (LLP firm) shall submit the copy of LLP Agreement (Mandatory for LLP firm /JV Firm having LLP Firm as a member)
The tenderer in the capacity of Limited liabilities Partnership firm (LLP firm) shall submit the copy of Certificate of Incorporation (Mandatory for LLP firm /JV Firm having LLP Firm as a member)
The tenderer in the capacity of Limited liabilities Partnership firm (LLP firm) shall submit the copy of Resolution of Partners of LLP firm (executed on the Letter Head of LLP firm) in favour of the individual to sign he tender on behalf of the LLP firm and deal with tender on dehalf of the firm as per proforma given in Annexure-XX.(Mandatory for LLP firm).
The tenderer in the capacity of Registered Society/ Registered Trust shall submit the copy of the certificate of registration (Mandatory for Registered Society/ Registered Trust and JV firm having Registered Society/ Registered Trust as a member)
The tenderer in the capacity of Registered Society/ Registered Trust shall submit the copy of the Deed of Formation (Mandatory f o r Registered Society/ Registered Trust and JV firm having Registered Society/ Registered Trust as a member)
A copy of power of attorney in favour of the individual to sign the tender document and create liabilities against society/trust (Annexxure XXI)
The tenderer in the capacity of JV firm shall submit the Memorandum of Understanding of JV duly notarized as per proforma given in Annexure-X.(Mandatory for Joint Venture Firm)
Electrical work of sports complex at Jaipur Railway Station of North Western Railway.
EL-C-JP-T07-25-26
EL-C-JP-T07-25-26
Open
Works - General
9 Months
Jaipur, Rajasthan
₹0
₹2.4 L
18 Mar 2026
20 Feb 2026
4 Mar 2026
143 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,77,39,992 | ||
| — | 48.00 | — | — | ||
| Supply and fixing of G.I. pipe 50mm for cable laying with pole/wall/under road/floor etc. | — | — | — | 12,048 | |
| — | 2000.00 | — | — | ||
| Supply and laying of HDPE pipe conforming to IS 4984:1995, 50 mm dia wall thickness 3 mm under the road/PF/ in ground or as per site requirement. As per specification. | — | — | — | 2,32,000 | |
| — | 1000.00 | — | — | ||
| Supply and laying of HDPE pipe conforming to IS 4984:1995, 75/80mm dia wall thickness 3 mm PN-4 under the road/air. The work involves laying of HDPE pipe. As per specification. | — | — | — | 1,19,000 | |
| — | 2000.00 | — | — | ||
| Supply and laying of HDPE pipe, dia 160mm under road/ground/ floor/railway track or as per site requirement already excavated trench. As per specification. | — | — | — | 9,24,000 | |
| — | 3000.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec. ( trench work may be on kuchha/pucca land and all type of soil as per site requirement and without protective layer of brick) | — | — | — | 1,44,000 | |
| — | 1500.00 | — | — | ||
| Excavation & refilling of 0.5 m width, 1.2 m Deep trench in all kind of soil for laying of HDPE/ SPUN Pipe for underground cable crossing. As per specification. | — | — | — | 1,90,500 | |
| — | 4500.00 | — | — | ||
| Laying, testing & commissioning of LT cable in Air/laid concrete pipe /in ground in trench across crossing pole with transportation from main depot to required site. Note: - Cable will be supplied by Railways. | — | — | — | 94,500 | |
| — | 500.00 | — | — | ||
| Laying, testing & commissioning of 11 KV /33 KV XLPE cable in air/ ground/ in trench/spun pipe, with transportation from main depot to required site. Note: - Cable will be supplied by Railways. | — | — | — | 40,500 | |
| — | 300.00 | — | — | ||
| Drilling of horizontal bore below Rly track by pushing method for laying of HDPE/SPUN/DWC pipe of various sizes up to 450 mm dia. As per specification. | — | — | — | 8,41,800 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing & commissioning of VTPN type metal double door type 8 way DB with having 01 No. 250 Amp., 4 pole MCCB, 36 KA as incomer & 8 Nos. TP MCB, 10 KA 'C' curves, 40-63 Amp. Cap. as outgoing having suitable IP-54, IK-09 protection. | — | — | — | 2,06,864 | |
| — | 6.00 | — | — | ||
| Supply, fixing, testing and commissioning of VTPN DB 4 way having incoming 01 No. 125 Amp 4 Pole MCCB 36KA and outgoing 04 Nos. TP MCB 40/63 Amp 'C' Curve 10KA as required make from reference list. As per specification. | — | — | — | 1,25,760 | |
| — | 5.00 | — | — | ||
| Supply, installation, testing & commissioning of 04 pole MCCB, 250 AMP, 36 KA with double door encloser for outdoor purpose as par specification. | — | — | — | 71,760 | |
| — | 5.00 | — | — | ||
| Supply, installation, testing & commissioning of 04 pole MCCB, 125 AMP, 36 KA with double door encloser for outdoor purpose as per specification. | — | — | — | 44,215 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of fabricated Feeder Pillar distribution box made of MS sheet 1.6mm thick size 600x300x600mm with suitable MS stand Copper bus bar of 200A capacity and 2x63A MCB 4 pole as per specification. | — | — | — | 18,984 | |
| — | 20.00 | — | — | ||
| Supply, fabrication, erection, testing and commissioning of G.I. octagonal pole 7 meters long single/double arm suitable for street light fixture including digging of pit, making foundation and muffing with cement, concrete concrete 1: 3: 6. As per Specification. | — | — | — | 1,73,520 | |
| — | 40.00 | — | — | ||
| Supply and providing of cable marker - for underground cable (Other than PLTC) The cable marker shall be made of MS sheet 1.5 mm thick size 150 x 200 mm welded with 12 mm dia MS rod 01.50 Mtrs long. The lower end of rod should be turned in hooks shape and attached with the cable at the laying. | — | — | — | 6,840 | |
| — | 16.00 | — | — | ||
| Supply and Providing GI Pipe Earthing of 3 meter length. As per specification. | — | — | — | 19,616 | |
| — | 16.00 | — | — | ||
| Supply & providing copper plate earthing 4 metre deep, copper plate size 600x600x3 mm as per spec. | — | — | — | 1,14,400 | |
| — | 160.00 | — | — | ||
| Supply and fixing of Copper Earth Flat strip size 25x3mm as per spec. | — | — | — | 55,840 | |
| — | 100.00 | — | — | ||
| Supply fixing and commissioning of Single Sided LED Sign board with symbol. As per specification. | — | — | — | 2,38,300 | |
| — | 60.00 | — | — | ||
| Supply fixing and commissioning of Double Sided LED Sign board with symbol. As per specification. | — | — | — | 1,70,340 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of single stage Mono-block open well submersible pump set with control panel rating 2HP/1.5KW, Head range (M) :26 meters and above, size (MM) suction X delivery 50X40, Discharge (LPM):180 or above at 26 meter head suitable for single phase 50Hz AC supply make as per reference list. | — | — | — | 65,648 | |
| — | 2.00 | — | — | ||
| Supply 0f mono-block sub. Pump 7.5HP 415 Volt complete with accessories as per site requirement sight including un-lowering of existing pump, and as per specification enclosed. | — | — | — | 36,180 | |
| — | 2.00 | — | — | ||
| Lowering, testing & commissioning of horizontal mono-block submersible pump set including un-lowering of existing pump, as per specification. | — | — | — | 3,540 | |
| — | 200.00 | — | — | ||
| Supply of copper flat cable size 3x6 sq mm as per specification. | — | — | — | 23,400 | |
| — | 2.00 | — | — | ||
| Supply and installation of automatic control panel with star delta starter for 10 HP three-phase pump (Monopole/Submersible) including connections and providing cable from main board to control panel and connection for WLG in open bore well as per detailed specifications. | — | — | — | 40,972 | |
| — | 100.00 | — | — | ||
| Supply of G.I. pipe 50 mm dia 'B' class for delivery. | — | — | — | 34,400 | |
| — | 20.00 | — | — | ||
| Supply installation Testing & Commissioning of rechargeable batten type Emergency light, 60 LEDs 4W or higher with one hour minimum backup as per specification & make as per reference list. | — | — | — | 57,400 | |
| — | 100.00 | — | — | ||
| SITC of pre painted/G.I Cable Tray for Copper Piping complete with supports as per specification. | — | — | — | 66,800 | |
| — | 4.00 | — | — | ||
| Supply, fixing testing and commissioning of Astronomical timer multifunctional digital as per specification. | — | — | — | 35,944 | |
| — | 4.00 | — | — | ||
| SITC of LT heat shrinkable straight through joint (25-185sqmm cable). | — | — | — | 9,180 | |
| — | 8.00 | — | — | ||
| Supply, erection, testing & commissioning of outdoor type cable end boxes suitable for 11 KV 'E' 3 core 185 Sq.mm XLPE | — | — | — | 73,424 | |
| — | 2.00 | — | — | ||
| SITC of straight through joint 11 KV three core HT XLPE 185 SQMM | — | — | — | 22,564 | |
| — | 1.00 | — | — | ||
| Dismantling/shifting the existing lattice LED Light tower/High Mast. | — | — | — | 27,565 | |
| — | 8.00 | — | — | ||
| Supply & Fixing ISI marked (IS : 15683 ) Portable Fire Extinguisher, CO2 type flat base including valve, discharge hose of not less than 10mm dia, min.600mm long & complete in all respects including initial fill with CO2 gas confirming to IS:307 of 1966 filled to a filling ratio of not more than 0.667 and wall suspension bracket capacity of 4.5 kg capacity. | — | — | — | 59,472 | |
| — | 2.00 | — | — | ||
| Supplying and Fixing of fire bucket stand made out of MS angle with one coat of primer and two coat of enamel paint of approved shade including platform and associated civil works each stand should have four nos fire buckets of 24 gauge galvanized steel sheet, standard 9 liter capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters "Fire" in black and gold at approved location as per direction of Engineer in charge. | — | — | — | 8,014 | |
| — | 104.00 | — | — | ||
| SITC of variable refrigerant flow/VRV modular type air-conditioning system VRF/VRV inverter controlled with step less wide range of capacity control complete with indoor & outdoor units, as per detail given in specifications and having following items: Refrigerant to be used shall be R-410 a. modular type top discharge outdoor unit equipped with highly efficient multi scroll/twin rotary compressors with fully inverter, with multi inverter type compressor & suitable for 320 V-460V 50Hz. condensing unit to constitute required HP system (outdoor unit configuration/ capacity will be taken as per railway requirement) circuit to reduce the redundancy of compressor, special heat exchanger, low noise condenser fan with DC variable speed motor, auto address setting, auto check function for connection error, with sandwich type vibration isolator rubber pads, auto address setting and capacity as mentioned below, outdoor unit (nominal capacity delivered at 43°C) as per specification (cooling & heating operations) | — | — | — | 26,48,464 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing and commissioning of indoor unit of various type and capacity as mentioned below. The unit shall be equipped with suitable electronic expansion valve, which can communicate with the controller in the condensing unit, multispeed motor, self-diagnostic type cordless remote controller, coil section with DX coil, outer cabinet, drain pan, built in drain pump, drain water lift-up mechanism insulation, pipe connections, imported Y-joints & header, Tee, fresh air intake connector for cassettes etc. of various capacities as per specification. a)1.5 TR cassette type indoor unit | — | — | — | 1,99,692 | |
| — | 10.00 | — | — | ||
| 2.3 TR cassette type indoor unit | — | — | — | 3,50,130 | |
| — | 6.00 | — | — | ||
| 3.2 TR cassette type indoor unit | — | — | — | 2,28,090 | |
| — | 6.00 | — | — | ||
| 4.0 TR cassette type indoor unit | — | — | — | 2,29,254 | |
| — | 14.00 | — | — | ||
| Supply of Air cooled VRF Hi-wall type indoor unit 1.5/2.0 TR as per specification. | — | — | — | 4,31,620 | |
| — | 14.00 | — | — | ||
| Fixing and commissioning of Split AC 1.5/2.0 Ton inclusive first charging of refrigerant if required. | — | — | — | 16,702 | |
| — | 20.00 | — | — | ||
| SITC of cordless remote controller as per specification. | — | — | — | 20,420 | |
| — | 42.00 | — | — | ||
| SITC of copper distribution joint kit as per specification. | — | — | — | 2,38,644 | |
| — | 500.00 | — | — | ||
| SITC of control cabling: Supply & installation of control and transmission wiring between indoor and outdoor unit as per specification. | — | — | — | 81,000 | |
| — | 500.00 | — | — | ||
| SITC of Refrigerant piping: supply & installation of copper refrigerant piping of required sizes with nitrile insulation as per specification. | — | — | — | 7,00,000 | |
| — | 200.00 | — | — | ||
| Drain Piping: Supply, installation, testing and commissioning of rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6mm thick close cell nitrile rubber insulation as per specification. a) 32 mm dia | — | — | — | 46,800 | |
| — | 100.00 | — | — | ||
| Drain Piping: Supply, installation, testing and commissioning of rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6mm thick close cell nitrile rubber insulation as per specification.25 mm dia | — | — | — | 20,500 | |
| — | 2.00 | — | — | ||
| Supply & gas charging of refrigerant R-410a as per OEM design parameters (each cylinder gas 45 Kg) & testing as per specification. | — | — | — | 70,948 | |
| — | 10.00 | — | — | ||
| SITC of M.S. stands as per specification. | — | — | — | 43,430 | |
| — | 8.00 | — | — | ||
| Rubber mat (ISI marked) non-stick type suitable for 11 kv AC supply of size 2000x1000x25mm as per specification. | — | — | — | 7,728 | |
| — | 1.00 | — | — | ||
| SITC of 11 KV, 630A, 20kA/3 sec, Out door, Extensible type Ring main unit (RMU) in suitable RCC foundation with 2 no. Load break switch & 1 no. VCB / SF6 circuit breaker as per specification. | — | — | — | 3,41,365 | |
| — | 1.00 | — | — | ||
| Supply and testing of set of standard equipments/ instruments required for maintenance of CSS. (As per specification) | — | — | — | 93,709 | |
| — | 1.00 | — | — | ||
| Supply, erection, testing and commissioning of fire fighting equipment. (As per Specification) | — | — | — | 18,776 | |
| — | 2.00 | — | — | ||
| Supply, fixing testing and commissioning of 20 kVA UPS as per specification. | — | — | — | 8,15,518 | |
| — | 200.00 | — | — | ||
| Provision of MS Jali 1"x1" welded on MS angles as per specification. | — | — | — | 14,000 | |
| — | 40.00 | — | — | ||
| Supply, fixing, testing and commissioning of wall bracket/ mounted type industrial air circulator 600 mm sweep single phase 230V, 50Hz complete with all accessories along with wiring as per site requirement. Make shall be as per reference list. | — | — | — | 2,82,320 | |
| — | 500.00 | — | — | ||
| Supply of material and wiring of shed TP/FP with 1.5 sqmm single core multi-stranded copper wire PVC insulated in conduit 1.5mm thick 19mm size white colour shall be fixed with junction box TEE and 1.5mmsq PVC CU cable insulated multi stranded for earth wire and 5/6A, ceiling rose. The conduit shall be fixed with rawl plugs/ tied with 14 S.W.G. copper wire including connection as per spec. | — | — | — | 88,500 | |
| — | 1000.00 | — | — | ||
| Supply and provide MS flat of iron size 40x3mm with specers and fixing clamps as per specification | — | — | — | 1,63,000 | |
| — | 1000.00 | — | — | ||
| Supply and fixing casing caping of PVC size 75x75mm and 2mm thick with suitable nut bolts for fixing or tied with copper wire 14swg for 5/7 nos. of copper wire & earth wire as per spec. | — | — | — | 1,58,000 | |
| — | 1000.00 | — | — | ||
| Supply, laying and fixing five wire of PVC copper cable size 10sqmm flame retardant, low smoke single core insulated un sheathed multi-stranded copper conductor, voltage grade 1.1 KV (1100 v) conf to IS694-1990 or latest in five with one no 8 SWG copper earth wire as per spec. | — | — | — | 6,13,000 | |
| — | 16.00 | — | — | ||
| Supply fixing and commissioning of HT XLPE heat shrinkable type cable end box indoor type size 50 to 185 sqmm as per specification. | — | — | — | 91,248 | |
| — | 2.00 | — | — | ||
| SITC of change over switch 800A manual type as per specification. | — | — | — | 1,23,644 | |
| — | 1.00 | — | — | ||
| SITC of LT Panel 02 Nos. ACB 800A incoming, 06Nos. MCCB as outgoings as per specifications. | — | — | — | 4,70,866 | |
| — | 20.00 | — | — | ||
| Supply, erection, testing and commissioning of air circulator wall mounting brackets fan blade 400 mm sweep similar with fixing up at suitable height with foundation bolt and clamp etc. as per requirement. Make shall be as per T.S. | — | — | — | 98,980 | |
| — | 40.00 | — | — | ||
| Supply of name signage, backlit alpha-numeric signage for name plate as per specification in Hindi/English - size 6600x1200mms (Per word). | — | — | — | 2,88,080 | |
| — | 2.00 | — | — | ||
| 500 KVA CSS/PSS (CSS/PSS): Supply, installation, testing and commissioning of outdoor type readymade packaged type substation consisting of outdoor enclosure fabricated by GI steel with all interconnections fully type tested as per IEC 61330 consisting of following items(i) With 11KV, 630A. 21KA, Ring Main Unit consisting of 1 no. incoming On-load isolator & 2 no. outgoing VCB / SF6 CB with BUS PT metering module ,numerical relay 3 O/C + 1 E/F ,Model CV V+M . As per Specification, including foundation of bricks masonry. a)(i) With 11KV, 630A. 21KA, Ring Main Unit consisting of 1 no. incoming On-load isolator & 2 no. outgoing VCB / SF6 CB with BUS PT metering module ,numerical relay 3 O/C + 1 E/F, Model CV V+M. As per Specification. Including foundation of bricks masonry. | — | — | — | 14,69,242 | |
| — | 2.00 | — | — | ||
| (ii) 500 KVA, 11KV/0.433KV ONAN type copper wound Hermetically sealed type transformer with off circuit tap changer of -5% to +5% in steps of 2.5% each. As per Specification. | — | — | — | 12,96,390 | |
| — | 2.00 | — | — | ||
| (iii). LT panel consisting of 1 no. incoming 800A, 4P, 50KA, 433 Volt, ACB Manually operated fixed type with microprocessor release & outgoing MCCBs fixed type manually operated with microprocessor release : 5 nos. 200A, 3P, 36 KA , MCCB-LT feeders 1 no. 4P, 800A, 25KA Isolator - LT Bus coupler between CSS- I & II as per Specification. | — | — | — | 12,96,390 | |
| — | 2.00 | — | — | ||
| (iv) APFC panel of 200 kVAR MPP type heavy duty capacitor bank with MCCB 36 K as incomer, suitable for operation at 400 V , 3 phase, 50 cycles to be installed and interconnected in the CCS-I enclosure. As per Specification. | — | — | — | 2,74,252 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Doc
ATTACHMENT
GCCApril-2022.pdf
ATTACHMENT
JPO.pdf
ATTACHMENT
TenderDocSportsT07-25-26.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].