Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹9.8 L+₹2.4 L (33.4%)Rejected-Finance 91 DEFENCE ESTATE PHASE II NEAR AMBEDKAR PARK DEORI ROAD AGRA UP | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | L3₹10.8 L+₹3.4 L (46.9%)Rejected-Finance | L3 | Rejected-Finance BEING OTHER THAN L1 |
Tender Value
₹7.4 L
EMD Value
₹14,840
Closing Date
3 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST AGRA
Garrison Engineer East Agra, Gwalior House, 62 Taj Road Agra Cantt
PROVN OF BAGGAGE ROOM 09 X 06 MTR FOR TROOPS AT 411 I PARA FD COY UNDER AGE BRI OF GE EAST AGRA
2021_MES_429828_2
9332/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA
As per tender documents
9 documents required · 9 mandatory
₹500
GE EAST AGRA
₹14,840
Yes
12 May 2021
19 Apr 2021
10 May 2021
19 Apr 2021
3 May 2021
19 Apr 2021
60 days
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation etc not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as speicified and directed.
M&L Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed..
M&L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L Brick work with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L Rendering 15 mm thick on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:6 compound finished even and smooth without using extra cement complete all as specified and as directed.
M&L Rendering 15 mm thick on fair faces of walls of brick work or concrete surfaces in cement mortar 1:4 with water proofing compound finished even and smooth without using extra cement complete all as specified and as directed. Note: water proofing compound shall be measured seprately.
M&L Rendering 10 mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:3 and finished fair and even without using extra cement complete all as specified and directed.
M&L for Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
M&L for Earth filling under floor, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed.
Removing of excavated materials to a distance not exceeding 50 M and deposing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
Supply only Integral water proofing compound
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in copings, bed plates, plinth courses, parapets and the like including weathering, slightly rounded or chamfered angles and throating including use and waste of necessary form work etc complete all as specified
M&L Reinforced cement concrete (design mix) M-25 (using 20mm graded stone aggregates) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L Reinforced cement concrete (design mix) M-25 (using 20mm graded stone aggregates) in Chajja and the like complete all as specified and directed.
M&L Reinforced cement concrete (design mix) M-25 (using 20mm graded stone aggregates) in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L Reinforced cement concrete (design mix) M-25 (using 20mm graded stone aggregates) in beams, cantileavers, bressumers, lintels etc complete all as specified and directed.
M&L for RCC Design mix M-25 as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundatiion and plinth beams and similar work vertical or to batter frough finished flat surfaces complete all as specified and directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat rough finished surfaces complete all as specified and directed.
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc flat surfaces complete all as specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns, and stanchions flat finished surface complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over as in reinforcement cut to length, bent in shape required including cranking, bending, spirally hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
M&L for mild steel TMT bars 6 mm to 8 mm dia and over as in reinforcement cut to length, bent in shape required including cranking, bending, spirally hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
Ditto as per item 22 but 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders
M&L hard core broken stones or boulders of gauge n exc 63 mm , deposited , spread and levelled in layers n exc 15 cm thick , watered and rammed to a true surface complete all as specified and directed.
M&L cement concrete type D-2 1:4:8 mix ( using 40 mm graded stone aggregate) as in sub base of flooring of 75 mm thick complete all as specified and directed.
M &L for machine cut kota stone slab flooring of size (580x580 ) mm and 18-20mm thick laid over 20 mm thick screed bed in cm 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed.
M&L for 50 mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection laid in bays not exc 1.5m with expansion joints 30x10mm filled with mixture of hot bitumen and sand, finished the surface even and smooth without using extra cement complete all as specified and directed
M&L for preparation of new plastered surfaces of wall and applying three coat of white wash complete all as specified and directed
M&L Preparation of newly plastered/ concrete surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer (self primer) complete all as specified and directed.
M&L 25 mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4 type B-0 (Using 12.5 mm graded stone aggregate). Complete all as specified and directed.
M&L socond class hardwood plain, solid straight chowkats and frames wrought framed rebated on the solid, rounded or chamferred, put together with gule pinned at joints, supplied and fixed Complete all as specified and directed.
M&L 2nd class HW plain, framed, panelled shuutters (any number of panels) with panels of timber flat on both sidses (feather edged) or of venered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats 35 mm thick Complete all as specified and directed.
S & F 300 mm long aluminium alloy, anosised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts of extruded sections Complete all as specified and directed.
M&L 100mm size But hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, type B-11 complete all as specified and directed.
S & F 150 mm long Extruded handles, fabricated type, aluminium anodised complete all as specified and directed.
S&F steel windows with side hung shutters incl Box type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
M&L for applying two coat of synthetic enamel paint on new steel surfaces of any description not otherwise described over 10 cm width or girth over red oxide including necessary preparation complete all as specified and directed
M&L preparation of new wood surfaces and applying two coats of synthetic enamel paint over a coat of of pink primer complete all as specified and directed.
M & L for water proofing treatment of roof slab all as specified below: - (a) Preparation of roof surfaces by brushing, cleaning and M & L for applying 10 mm thick plaster in CM 1:4 with water proofing compound @ 2% by weight of cement. (b) Applying a priming coat with bitumen primer @ 0.4 ltr/Sqm (c) M & L for laying APP membrane 3 mm thick having non woven polyester matt at core and under surface coated with plastic polythene film.
M&L for brick tiles 40mm thick laid over and including 15mm thick screed bed of cement mortar 1:6 and joints grouted flush in CM 1:3 with & including crude oil @ 5% by weight of cement complete all as specified and directed.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. Grade FR PVC insulated unsheathed cable with proper colour coding drawn in including PVC concealed conduit not less than 20 mm dia with all accessories and FR PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, snk in cast iron/Pressed steel terminal boxes 60 mm deep & 1.6 mm thick dly painted with aluminum inside and anticorrosive paint out side/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the distrubed suface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimles. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following:- (a) One light/fan point controlled by one switch
Supply and fix swithc piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
Supply & fix sheet metal enclosure MCB distribution board double door. Single pole & netral 240 volts 4 way with IP-43 protection double door compete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with exising specification all as specified and directed. Make : Legrand/Schneider (Acti-9)/L&T/ABB/SIEMENS
Supply and fix MCB single pole 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA Ç'series including providing thimble for out going cables. Make Cat Pt No 4085 90 of Legrand or equivalent in Schneider/Acti-9/L&T/Hager.
Supply and fix MCB single pole and neutral 240 volts any rating from 32 amps, with rupturing capacity 10 KA Ç'series, including providing thimble for out going cables. Make Cat Pt No 4086 14 of Legrand or equivalent in Schneider/Acti-9/L&T/Hager.
S&F surface and wall mounted LED batten prewired suitable for use with LED 20 Watt including LED 20 watt tube rod complete including connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50 Sqmm. All as specified and directed. Make : Cat Pt No LHFXCENNTN1W020 for box type fitting and Cat Pt No LHLDDCXCML8Q020 LED Tube Rod of Havells or equivalent in Bajaj/Philips/CG
S&F Lamp holder/angle holder insulated body with black/white plate for batten fittings complete all as specified and directed.
Gupta Automobiles
Balaji Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .