Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.8 LAccepted-AOC 67 A HAFIZALI BAHADUR KHAN MARG SURAJI COMPOUND BEHIND KHATAU MILL BYCULLA W MUMBAI 400011 BRITE INDUSTRIES 67 A HAFIZALI BAHADUR KHAN MARG SURYAJI COMPOUND BEHIND KHATAU MILL MUMBAI | MUMBAI | MAHARASHTRA | 400011 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹78.8 L+₹3.0 L (3.92%)Rejected-Finance FLAT NO 201 GF KAMAL VIHAR CGHS LTD PLOT NO 5 SECTOR 7 DWARKA NEW DELHI 110075 | NEW DELHI | NEW DELHI | DELHI | 110075 | L2 | Rejected-Finance Other than L1 |
Tender Value
₹74.8 L
EMD Value
₹1.4 L
Closing Date
2 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ Chief Engineer Lucknow Zone
Headquarter Chief Engineer Lucknow Zone, 17 Carriappa Marg Post Dilkusha, Lucknow Cantt PIN -226002
PROVISION OF DEHUMIDIFIER FOR CERTAIN UNITS AND OUTSOURCING FOR DEHUMIDIFIER UNDER GE (EAST) AGRA CANTT
2022_MES_527184_1
CELZ/AGR/T-08 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
450 days
GE (East) Agra
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE(East) Agra
₹1.4 L
Yes
23 Aug 2022
28 May 2022
4 Jul 2022
28 May 2022
2 Jul 2022
20 Jun 2022
Amount
Supply, Installation, testing and commissioning LT panel board indoor type design vertical as per IS/IEC 61439-182 for 415 volts, 50 Hz rated fault level 65 KA with internal arc containment with IP 54 protection rupturing capacity at 415 volts, factory made in as approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns with paint shape RAL -7035 provided with suitable gasket to make it dust/vermin proof & general contruction comprising of following :-
(a) INNER SHELL :- Inner shell made out of 2.0 mm thick CRCA sheet duly compartmentalised for each control gear, front & back openable single door system lockable / openable keys from both sides having chromium plated 19 mm dia fancy locks (02 Nos in each compartment having louvers & air vent gasket for natural flow of air, "U" type gasket shall be used to made the inner shell completely vermin proof & to accommodate incommer/out going MCCBs and electrical grade aluminium for rated continuos current of 250 Amps for main bus bar with 65 KA short time current (rms) for 1 Sec & 105 KA (Peak) rated dynamic short circuit with stand with heat shrinkable sleeves alongwith shoulder for joints & earth bus bar of aluminium 50x10 sqmm size (Minimum ) with short circuit rating of 30 KA per sec duly colour code shall be mounted on suitable size "F" class insulator made of nonhygroscopic, noncumbustile, track resistant high strength FRP/SMC/DMC material at an interval not less than 500 mm through out the length of the TPN busbar. The cubical incomer MCCB as well as out going shall have aluminium TPN extension links of current carrying capacity not less than1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300 mm long supported on suitable size "F" class insulator made of non hygroscopic, noncumbustile, track resistant high strength FRP/SMC/DMC material at interval not less than 500 mm through out the length of the TPN bus bar. The cubical incommer MCCB as well out going shall have aluminium TPN extension links of current carrying capacity not less than 1.5 time the rated capacity of individual feeder, the extension links shall not be less than 300 mm long supported on suitable size F Class insulator made of non hygroscopic, noncumbustile, track resistant high strength FRP/SMC/DMC material having provision for termination of incomer & Outging cables.
(a) (Contd...) All inter connections between the bus bar as well as outgoing feeder shall be carried out with TPN copper busbar of rating not less than 1.5 times rated capacity of individual outgoing feeder & should be insulated with heat shrinkable PVC sleeves.All control wires shall be with 2.5 Sqmm multistranded copper conductor and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of copper lugs. The cubical shall have a bottom channel of size 75 mm x 40 mm duly coated with zinc metal coating having thickness not less 100 microns. A detachable predrilled gland plate of thickness 3.15 mm powder coated should be used at the bottom. The inner shell should be powder coated siemens grey structural RAL7032 shade. An inspection lamp LED 5 watt with movable non ferrus chromium plated arm fitted on top side of inner shell should be provided. The degree of protection for inner shell shall be IP -42 & carry the following controls :-
(b) Supply, Installation, testing and commissioning Indoor type, cubical type, LT panel board design vertical as per IS/IEC 61439-182 for 415 volts, 50 Hz rated fault level 65 KA with internal arc containment with IP 54 protection rupturing capacity at 415 volts, factory made as approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns with paint shape RAL -7035 provided with suitable gasket to make it dust/vermin proof & general contruction comprising of alluminium bus bars of capacity 400 amp for phase 250 Amps for neutral complete all as specified and directed for the following switchgear & controls :- The panel shall include the following components & accessories. (i) Phase indicating lights and indicating light for ON status set of three. (ii) Digital Multifuctional panel meter for Amp,volt,KWH,PF and other parameters flush mounting of size 96 mm x 96 mm.-01 No.
INCOMING : MCCB, 4 pole, 250 Amps, 415 Volt, with Icu 36 KA, Ics=100%Icu, Microprocesser release and adjustable overload setting (Min 70& to 100%) as per IEC - 60947-I and 60947-2 standard, , all as specified and directed - 01 No. Make C&S/ Legrand/ABB/Schinder
OUTGOINGS : (a) MCCB, 4P,63 Amps, 415 Volt, , Ics =16 KA, with thermal magnetic release alongwith adjustable magnetic protection for current setting ics=100%Icu with adjustable over load setting (minimum 70% to 100%) value from 10 to times of related capacity as per IEC - 60947-I and 60947-2 standard, Qty - 05 Nos (04 Nos in working + 01 Standby). (b) MCB TP, 16 Amps 'C' series 10 KA - 02 Nos
Supplying, Laying, Jointing and testing XLPE insulated, PVC sheathed, armoured heavy duty electric cable of size cross sectional area 4 core 240 Sq mm LT, 1100 volts grade with aluminum conductor, passing through pipes, in duct, on poles, in trenches under road/floor etc, all as sppecified and directed..
M&L for earthing complete with galvanised steel earth plate electrode 600 x600 x 6 mm thick buried directly in ground, earth plate not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5mtr below normal ground level connected to and including galvanized steel earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron and using charcoal and salt upto plate edge level including PCC pit in PCC 1:2:4 type B-1using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 40 mm bore, main board complete all as shown in electrical plate No 3 of SSR Pt I of 2009 connected to equipment and testing on completion, complete all as specified and as directed. Note : Protection pipe and GI strip upto 7.5 mtr is included in the unit rate. contractor shall be deemed to quote the rate accordingly.
S&F GI strip of size 25 mm x 4 mm thick duly fixed with wall /floor/ equipment complete all as specified and directed
S&F Steel Tubes, light grade, galvanised, 40 mm bore with all fittings, and fixed to walls and ceiling or laid in floors etc complete all as specified and directed. Note :- This item will be required as and when strip required beyond 7.5 m for any earthing .
Excavation in trenches n exc 1.5 metre wide and n.exc 1.5 metre depth in soft/loose soil for laying UG cables complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cms all as specified and directed
Removing excavated material to distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed.
Supplying, spreading and compacting approved river sand in trenches for cable cushioning at bottom with a layer of 8 cm high before laying of cable and 15 cm thick after laying and stretching cable all as specified and directed.
Supply and laying burnt bricks sub class 'B' of old size laid dry in trenches for cable protection complete all as specified and directed.
S & F GI tube light grade 80 mm bore laid as fixed walls and ceiling or laid in floors complete all as specified and directed with MS clamp and nut bolts and washers etc, with all fittings complete all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, warshers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed.
SCHEDULE 'A' PART-II M&L for Outsourcing (manning & operation) and including routine comprehensive maintenance of dehumidifire plant of capacity 7200 cfm complete for its proper smooth functioning and including operating & maintenance of complete along with connected panel board and connecting fixing accessories of complete system etc including repair / rectification of loose / tightness connection and also changing of defective parts which is easly done by techanician at site and making as when required to ensure serviceability of complete plant and daily checking of any type of leakage of gas / pressure / water drop in dehumidifire plant and taken immediate action to stop the same leakage and making pump down the complete system including cleaning of complete plant / plant room / surrounding area neat & clean and removing grass from installation yard and surrounding area and also recording of hourly basis Dehumidifire plant run in specific log sheet which is as approved by Engineer in charge and log sheet will be supplied by the contractor for all working days and also working of one single shift duty operator basis of each shift of 08 hours (one shift per day) including sunday and holiday) at dehumidifire plant installation complete all as specified and directed.
For 1st year (Manning & Operation)
Note for item No. 14.00 :- (i) The M&O shall commence from the date of completion of work covered under Ph-I . (ii) The plants shall be run on all working days or as per basis on user requirements times or as per time schedule direction by AGE E&M / GE and including sunday and holiday . (iii) The unit rates shall be also be deemed to be inclusive for to maintain desired temp as per CA if not so more than one hour the necessary panel recovery @ 2000/- per day shall be deducted. (iv) The unit rates shall also be deemed to be inclusive for uniform and T&P required for shift duty operator and routine check & maintenance of installation i.e. hand gloves, pliers, testers, DE wrench set, ring spanner set, box wrench set, screw driver set, adjustable wrench, including all type of tool which is required at site. (v) The unit rates shall also be deemed to be inclusive for proforma of log sheet, cleaning of plant etc will be arranged by the contractor at no extra cost. (vi) The contractor shall rectify / replace all the defective parts during defect liability period without extra cost and the cost of the same is included in respective item of dehumidifire plant. All consumble items are included in the unit rate of M&O items.
Note: (Contd-----) (vii) Contractor shall pay not less than the minimum wages, will pay EPF, ESI etc as per labour law to all his workers payment of wages to labour / worers deployed by the contractor shall be done by cheque or through NEFT in their bank account No. RAR / Final bill shall not be made to contractor / firms unless proof of payment through Bank of wages to the work in is submitted by the contractor.
SHRI RAMSONS PROJECTS CORPORATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .