Chief Engineer
Office of Chief Engineer, Sardar Patel Road, Dote Campus, Chennai 25
Upgradation of additional 2 class room with staircase (under RUSA scheme) over the existing politcal science Department building in Periyar Government Arts College at Cuddalore in Cuddalore District.
2024_HE_449096_1
CuddaloreRUSA2_2023
Open Tender
Civil Works - Buildings
Lump-sum
90 days
Cuddalore
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹39,000
Yes
16 Jul 2024
15 Mar 2024
26 Mar 2024
15 Mar 2024
25 Mar 2024
15 Mar 2024
Amount
Dismantling clearing away and carefully stacking materials useful for reuse for any thickness of wethering course and pressed tiles of one course roof finish in cement mortar and stacking carefully away from the site for reuse etc. complete complying with standard specification and as directed by the departmental officers.
Dismantling clearing away and carefully stacking materials useful for reuse for any thickness of RCC complete etc., complete complying with standard specification and as directed by the departmental officer.
Dismantling clearing away and carefully stacking materials use for reuse for any thickness of brick/stone masonry in cement mortar walls under 3 m height etc complete complying with standard specification and as directed by the departmental officersl.
Earthwork excavation for foundation in all soils and sub soils to full depth as may be directed except in hard rock requiring blasting inclusive of shoring shuttering, baling out water wherever necessary, refilling the foundation with excavated earth and depositing the surplus earth within compound in places shown by the departmental officers with an initial lead of 10 metre and initial lift of 2 metre and clearing and leveling the site etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and Filling in foundation and basement with M sand Gravel mix (1:1) in layers of well rammed watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Cement concrete 1:5:10 (one cement, five M-sand and ten aggregate) using 40mm gauge hard broken blue granite stone jelly for foundation and basement including dewatering if found necessary and laid in layers of not more than 15cm thick and compacted etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and Filling in foundation and basement with gravel in layers of not more than 15cm thick well rammed watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and Filling in foundation and basement with Stone Dust in layers of not more than 15cm thick well rammed watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting steel centering including necessary supports for plane surfaces, for all RCC works including strutting upto 3.29m in all floors using mild steel shutters of size 90cmx60cm of BG 10 stiffened with mild steel angles of size 25mmx 25mmx3mm laid over silver oak (Country wood) Joists of size 10cmx6.5cm spaced at about 90cm c/c and supported by casurina props of 10cm to 13cm dia. (spaced at 75cm c/c) etc., complete complying with standard specification and as directed by the departmental officers. (The centering will be removed after specified period of concrete without damaging the concrete)
For plain surface such as RCC floor slab, roof slab, beam litels bed blocks, landing slab, waist slabs and beams, etc.,
For plain surface such as rectangular or square RCC columns, sunshdes, top and bottom slab of RCC, etc.,
Providing additional strutting using casurina poles to centering of RCC slabs or plane surfaces for every addtional 1 metre height or part there of but not less than 30cm over the initial height of 3m from floor level using casurina props of 10cm to 13cm dia including cross bracings etc., complete complying with standard specification and as directed by the departmental officer.
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accardance with IS 456-2000 using 20mm and down graded Hard broken Granite stone jelly for all RCC items of works with minimum cement content of 350 Kg/m3 and maximum water cement ratio of 0.50, including admixture ( plastciser/ super plasticiser ) in recommanded proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability withiut impairing strength and durability with about ( 5.0 cu.m ) 7730 Kg. of 20mm machine crushed stone jelly and with about ( 3.30 cu.m) 5156 Kg. of 10-12mm machine crushed stone jelly with about ( 4.79 cu. m) 7670 Kg. of M sand, but cxcluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with machanical vibrators, finishing,curing etc; and providing fixures like fan clamps in RCC floor/roof slab wher ever necessary without claiming extra, etc., complete complying with standard specifications and as directed by the Departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. ( No separate payment will be made by the Department for the excess usage of materials)
For Foundation & Basement
For Super structure in Ground Floor
For Super structure in First Floor
Cement Concrete 1:3:6 (One cement, three M sand and six aggregate) using 40mm gauge hard broken granite stone jelly for dummy columns,excluding cost of centering, shuttering, reinforcement grill fabrication charges but including consolidating as per standard specification, finishing, curing etc., complete complying with standard specification and as directed by the departmental officer.(Cement concrete 1:2:4 for slabs to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in cement concrete 1:3:6 Dummy column should be atleast in 1m height) etc., Complete complying as standard specification and as directed by departmental officers.
For Super structure in First Floor
Supplying, fabricating and placing in position of steel reinforcement using MS (or) RTS rods for all RCC item of works including cost of steel and binding wire in all floors etc., complete complying with standard specification and as directed by the departmental officers.
Brick work in cement mortar 1:6 (one cement and six M sand) using Third class kiln burnt country bricks of size 8 3/4 ”× 4 1/4" × 2 3/4” including curing etc., complete complying with standard specification and as directed by the department officers. (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost).
For Foundation & Basement
For Super structure in Ground Floor
For Super structure in First Floor
Brick work partition wall 10.80 cm thick using using Third class kiln burnt country bricks of size 8 3/4 ”× 4 1/4 × 2 3/4” in cement mortar 1:3 (One cement and three M sand including fixing hoop iron reinforcement if found necessary, laying, finishing and curing etc., complete complying with standard specification and as directed by the departmental officers.
For Super structure in First Floor
Fabricating supplying and fixing in position CRCA pressed steel box section 18 gauge or 1.25mm thick for door frames of section size 105mmx60mmx1.25mm thick with necessary rebate of size 35x15mm for housing door shutters conforming to IS specification. Frames shall be fabricated to the specified door size with joints properly welded and grinded. Stiffeners with 25x3mm MS flat shall be provided around the frame at 60cm intervals. The cost shall also include for providing 3 Nos. of MS clamps with 25x3 flats each on either sides of door frame, providing bottom tie, with 10mm dia MS rod, providing necessary holes for receiving tower bolts 2 Nos. with stiffeners on inner side, providing the required number of I.O hinges of size 125x30mm for shutters properly welded to the frames, finishing the door with one coat of good quality red oxide primer with cement concrete 1:2:4 (One cement, two sand and four aggregate) using 20mm gauge hard broken granite stone jelly packed inside to the frame including cost of all materials, fabrication and conveyance to the site and fixing in position with necessary scaffolding etc., complete complying with standard specification and as directed by the departmental officer.
Supplying and fixing in postion of 35mm thick solid core flush door shutters with following specification. with commercial ply on both sides and with TW lipping of size 35x12mm on all edges with necessary adhesives and C.P. Screws Alu. Butt Hinges (6 nos. 250 x 16 mm Size) Alu. Aldrop1 No. 250 x 16 mm Size, Alu. Tower Bolt 2 No. 250 x12 mm size, alu. Tower Bolt 2 No. 200 x 12 mm size, D type alu. Handle 200mm length 2 No., alu. door stopper with rubber bush 2 No. shall be provided, as directed by the departmental officers etc., complete.
Double Leaf
Manufacturing, Supplying and Fixing in position of M.S.steel window with following specifications. The outer frame of window made out "Z" section (F7D) of size 33x25x3mm at 1.419 Kg/m and mullion of "J" section (F4B) of size 45x25x3mm at 2.28 Kg/m. Shutter made out of (F7D) section of size 33x22x3mm at 1.419 Kg/m. Each openable shutter should not be exceeded a width 600mm to enable separate operations and easy maintenance. 2Nos. of sturdy hinges and one number of handle cum latch of special type make with 18x5 MS flat are revetted to the shutters of an appropriate height in each window shutter. Suitable opening is left for its easy operation. A stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. Each shutter having an adjustable window stay made out of 18mmx5mm at 0.70 kg/m MS flat of length 320mm with free adjustable positions.
A matching peg is provided in the outer frame of the window, at suitable place, 4Nos of holdfasts of 200mm length MS angle 40x40x6mm the ends are welded to the outer frame of the window, 18 mmx 5 mm at 0.70 kg/m MS flat is welded to the shutter at two places, equal distance from each other from top and bottom of the shutter. 18 gauge cold rolled sheet of superior quality is laid as panel in the shutter frames and welded intact. Stiffeners with 18x5mm at 0.70 kg/m MS flat of suitable length welded diagonally to all four corners of each openable shutter to hold the CR sheet in position firmly. MS square bars of 12mm size is welded to the inner face of the window at equal intervals not exceeding 100mm edge to edge between them. All members are painted with one coat of anticorrosive red oxide primer as directed by the departmental officers. All sections used should confirm to IS 7542 / 1990. The rate includes cost of all materials, labour charges, transportation to taxes and other incidental charges etc. complete.
Three Leaf
Two Leaf
Supply and Fixing of M.S. steel doors with Single Leaf following specification. MS angles of size 40x40x 6mm at 3.5 kg/m used for the outer frame and MS angles of size 35x35x5mm at 2.60 kg/m for the shutter frames. Stiffners with 32x6mm at 1.50 Kg/m. MS flat is provided as the lock rail of the door and welded infact of both ends to the shutter frame, 18 gauge CR sheets of best quality is laid as panel in the shutter frames. 18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50 Kg / RM and MS flat on the rear side of the door sandwitching the CR sheet for rigidity with locking rail and bottom tie arrangements. Additional stiffners with 18x5 mm at 0.7 kg/m MS flats are provided horizontally diagonally on the rear side of the shutter. 2Nos of hinges in case of single leaf and 4Nos of hinges in case double leaf shutter is provided 6 Nos of hold fasts 200 length 40x40x6mm M.S. angle spliced at the ends are welded to the outer frame of the door. Tower bolt 2 Nos. one at top and the other at bottom are provided. One aldrop is provided incase of double leaves door at lock rail section in the door. For single leaf doors, one more aldrop is provided in the inner side at the lock rail section of the door.
One rotating locking arrangements at the inner side of the door and additional provision for locking arrangements for lock is provided with 32x6mm MS flat on the rear side of the door at an appropriate place incase of a double leaves door MS flat 32x6mm at 1.50 kg/m is provided on the edge of one shutter to conceal the gap between the shutters. A tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation of fixing. All members are given a shop coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials labour charges transportation taxes and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officer
Supplying and Fixing in position steel balustrades using 20mm square rods at 150mm c/c and two balustrades in a single step centrally located and top welded with M.S. flats 40x6mm for fixing with the M.S.hand rails having a groove 40x6mm and bottom fixed in the step concrete firmly M.S.flat of size 50x6mm to be provided at the Centre of balustrades connecting all square rods of size 20mm fixing at 15cm c/c to the entire length of the balustrades welding all faces intact including one coat of primer anti corrosive paint for the square rods and flats etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and fabricating and fixing in position 40mm dia GI pipe 'B' class for hand rails on the flats of steel balustrades including cutting the pipe to the required length and shape grinding the edge smooth welding wherever necessary as directed by the departmental officers including cost of one coat red oxide primer etc., complete complying with standard specifications and as directed by the departmental officers . The rate includes cost of GI pipe, taxes and labour charges for fixing in position.
Supplying and fixing in position of PVC rain water down fall pipes 110 mm dia of best quality approved of ISI having a working pressure of 4 kg / sq.cm including cost of necessary PVC shoe, PVC bend, C.I. gratings of required dia. and special clamps, brass screws, nails etc., and fixing of cast iron gratings at juction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cost of removable iron grating. The PVC pipe shall be fixed on wall with special type of clamps. Special type "U" clamp at the centre of the pipe line shall be fixed in addition to those for more than 3.0M pipe length complying with standard specification.
Supplying and installation of Ceramic Steel chalk writing board with the following specification. The 2mm GI Sheet is placed with wall side over the GI sheet necessary adhesive is spreaded and fixed the 9mm MDF board on the GI sheet 0.40mm thick ceramic steel chalk board is provided over the MDF board and the whole arrangements are fixed to the frame using heavy anodized Aluminium section and Chromium plated provided in the corners. The whole arrangement are fixed to the wall using wooden plugs and screws etc., The rate includes all above materials, labour charges and taxes etc., complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering in all floors and finishing the exposed surface of RCC items of work such as slab, beam, sunshade, facia, canopy slab, staircase waist slab, landing slab etc., with cement mortar 1:3 (One cement and three P-sand) 10mm thick with Bonding agent Cebex112, Zydex- Zycrete 2X or other Equalent compound conforming to BIS at 200 ml of one cement bag (50kg) for increased workablity and air entrainment including hacking the surfaces and providing cement mortar nosing, beading for sunshade, staircase, step, landing slab etc., including neat finishing and curing etc., complete complying with standard specification and as directed by the departmental officers.
Plastering with cement mortar 1:5 (one cement and five P-sand) 12mm thick mixed with Bonding agent Cebex112, Zydex- Zycrete 2X or other Equalent compound conforming to BIS at 200 ml of one cement bag (50kg) for increased workablity and air entrainment used finishing in all floors using fine P sand including neat finishing, curing, etc., complete complying with standard specification and as directed by the department officers.
Supplying and fixing colour galvalume sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing MS grills to doors, windows and ventilators etc. using necessary MS flats (or) square rods for inner members and outer members which should be fixed to window frames as directed and design given by the departmental officers inclusive of cost of providing one coat of best quality red oxide primer etc., complete complying with standard specification and as directed by the departmental officers .
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three M sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Weathering course using best quality of broken brick jelly of 20mm gauge in pure slacked lime (no sand to be added) the proportion of brick jelly to lime being 32:12.5 Cft. by volume and laid over the RCC roof slab in a single layer and consolidated to the required design and finished thickness and slope by beating the concrete with wooden beater of approved pattern and keeping the surface constantly wet by sprinkling lime jaggery water etc., complete complying with standard specification and as directed by the departmental officers.
Finishing the top of roof with one course of Machine pressed tiles of size 23×23×2cm of approved quality laid in cement mortar 1:3 (One cement and three M-sand) 12mm thick mixed with water proofing compound (confirming to Indian standard specification) 2% by weight of cement used and pointed with the same mortar including mixing of red oxide and water proofing compound etc., complete complying with standard specification and as directed by the departmental officers.
Paving the floor with Stain free nano polished vitrified tiles (like Marbonite or equivalent) of approved quality and colour of size 600 x 600x 8 mm thickness in all floors over a base layer of cement mortar 1:3 (one cement and three M sand) 20mm thick and pointing with white cement using 0.30kg/m2 including adding suitable colour pigments to suit the colour of tiles finishing perfectly and curing etc., including cost of tiles, all materials and incidential charges, transportation charges and labour charges for laying tiles etc., complete complying with standard specification and as directed by the Departmental officers. (The tiles should be got approved by the Departmental officers before use on works).
White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed by departmental officers.
Painting the walls two coats with best Oil bound distemper of approved quality over one coat of primer for newly plastered wall including preparation of surface and finishing neatly including cost of all materials, brushes, scaffolding charges etc., complete complying with standard specification and as directed by the departmental officers.
Painting the exterior walls surface two coats of best and approved first quality and colour of Exterior emulsion paint in all floors over one coat of primer including preparation of surface, wall putty two coats with good quality and including labour charges for rubbing the wall scrapping putty pasting works and making good smooth surface and finishing neatly etc.,complying with standard specification and as directed by the departmental officers( The quality and colour of paint should be got approved by the departmental officer before use of work)
Painting the new iron work with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat and including cost of painting materials, brushes, putty, preparation of surfaces and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officer. (The quality and colour of paint should be got approved by the departmental officer before use on work).
Painting the new wood work two coats with best approved first quality and colour of synthetic enamel paint over a priming coat of approved quality in all floors including cost of paint, labour and other materials like brushes, putty and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officers. (The make quality and colour of paint should be got approved by the departmental officer before use on work).
Painting the exterior walls surface one coat of best and approved first quality and colour of Exterior emulsion paint in all floors over existing coat of primer including preparation of surface, wall putty two coats with good quality and including labour charges for rubbing the wall scrapping putty pasting works and making good smooth surface and finishing neatly etc.,complying with standard specification and as directed by the departmental officers( The quality and colour of paint should be got approved by the departmental officer before use of work)
Sub Total
M/S FATHIMA ENGINEERING COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .