Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹10.0 Cr
EMD Value
₹5 L
Closing Date
9 Dec 2026, 5:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
- Naveen Tiwari(DFLT)
MUNICIPAL COUNCIL, JASHPUR-NAGAR
CONSTRUCTION OF HIGH-TECH BUS STAND AT JASHPURNAGAR(1ST CALL)
204243
NIT No:-495/ NPP/TN/2026 Jashpurnagar Dated:- 18.11.2026
RESTRICTED TENDER
WORKS
PERCENTAGE
18 days
MUNICIPAL COUNCIL, JASHPUR-NAGAR
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
17 documents required · 17 mandatory
Urban Administration and Development Department (UADD)
WORKS
- Naveen Tiwari(DFLT)
RESTRICTED TENDER
PERCENTAGE
A
MUNICIPAL COUNCIL, JASHPUR-NAGAR
TENDER SECTION
CHIEF MUNICIPAL OFFICER,MUNICIPAL COUNCIL, JASHPUR-NAGAR
120
18
No
1
204243
9 Dec, 2026 5:30:00 PM IST
11 Dec, 2026 5:00:00 PM IST
18 Nov, 2026 5:00:00 PM IST
NIT No:-495/ NPP/TN/2026 Jashpurnagar Dated:- 18.11.2026
CONSTRUCTION OF HIGH-TECH BUS STAND AT JASHPURNAGAR(1ST CALL)
500000.00 INR
Demand Draft (OFFLINE) Fixed Deposit Receipt (OFFLINE)
100051000.00
2
11 Dec, 2026 3:00:00 PM IST
100051000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
20d 21h 31m
17 documents required · 17 mandatory
₹0
₹5 L
18 Nov 2026
18 Nov 2026
11 Dec 2026
18 Nov 2026
11 Dec 2026
120 days
NAGAR PALIKA PARISHAD JASHPUR NAGAR, JASHPUR ( C.G.)
DETAIL ESTIMATE FOR CONSTRUCTION WORK OF PROPOSED HI-TECH BUS STAND
S.N. SOR ITEM NO. PARTICULAR OF ITEMS Qty. Unit
1 BS 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils. 16689.07 cum
2 BS 1.6 Extra for every additional lift of 1.5 m or part thereof.
1.6.1 All types of soils 418.41 cum
3 BS 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M. 2629.51 cum
4 BS 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. 4371.98 cum
5 BS 1.19 Providing filling and compacting local earth (from approved source pit) in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. 32037.14 cum
6 BS 1.26 Carriage by mechanical transport upto 5 km lead:
6.1 1.26.1 Earth 44.96 cum
6.2 1.26.2 Sludge 13037.82 cum
7 BS 3.1 Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work.
7.1 BS 3.1.2 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size). 1125.73 cum
7.2 BS 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). 540.55 cum
7.3 BS 3.1.5 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). 2447.67 cum
8 BS 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). 2249.51 cum
9 BS 3.2.1 + 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 765.63 cum
10 BS 3.2.1 + 3.4 + 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 358.82 cum
11 BS 3.2.1 + 3.4 + 3.4 + 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 108.29 cum
10 BS 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D 399195.21 kg
11 BS 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work. 5.30 cum
11 BS 2.1 Providing and fixing form work including centering, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
11.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. 6257.31 sqm
11.2 BS 2.1.2 Wall of any thickness including attached pilasters, buttresses etc. in super structure. 2733.45 sqm
11.3 BS 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape 2808.12 sqm
11.4 BS 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) 3969.77 sqm
11.5 BS 2.1.8 Beams, lintels, cantilevers & walls 3042.43 sqm
11.6 BS 2.1.15 Stair cases of all types excluding spiral and folded plate type, including risers and landings 158.08 sqm
12 BS 4.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom, kitchen etc., by applying cement slurry mixed with water proofing cement compound consisting of following applications including surface preparation: i) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound@ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 166.28 sqm
13 BS 4.7 Providing and laying integral cement based water proofing treatment on roofs, balconies, terraces etc with average thickness of 120mm and minimum thickness at khurra as 65 mm, consisting of following operations including surface preparation: i) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement mixed with water proofing compound conforming to IS. 2645 over the RCC slab including adjoining walls upto 300mm height. ii) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) mixed with water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) mixed with water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm height including 2627.70 sqm
14 BS 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand) 168.40 cum
15 BS 7.5.4 + 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 504.32 cum
16 BS 7.5.4 + 7.6 + 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 281.89 cum
17 BS 7.5.4 + 7.6 + 7.6 + 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 54.50 cum
16 BS 7.11 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level:
7.11.2 Cement Mortar 1:4 (1 cement : 4 coarse sand)
7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: 110.97 Sqm
17 BS 7.20 Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry. 110.97 Sqm
18 BS 8.1 Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position.
8.1.2 Sal, bijasal, benteak, khair, haldu 1.01 cum
19 BS 8.3 Providing 40x5mm iron hold fast 40cm long including fixing to frame with 10mm bolts nuts and wooden plug and embedding in Cement Concrete 1:2:4 in blocks of size 30x10x15cm. 120.00 each
19 BS 8.16 Providing and fixing PVC membrane foil coated (laminated) flush door shutters, made with core of block board with frame of first class hard wood, coated with 0.30mm membrane pasted with resin using vacuam treatment process complete all but excluding hinges.
8.16.1 35 mm thick (single leaf) 122.58 sqm
20 BS 8.154 Providing and fixing 30mm thick fibreglass reinforced plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856 : 2000, complete. 44.33 sqm
21 BS 8.58 Providing and fixing bright finished brass butt hinges with brass polished MS screws complete:
8.58.1 125x85x5.50 mm (Heavy Type) 222.00 each
22 BS 8.60 Providing and fixing bright finished brass sliding door bolt with nuts and brass polished MS screws complete:
23 BS 8.61 Providing and fixing brass door latch with brass polished MS screws complete:
24 BS 8.62 Providing and fixing bright finished brass tower bolts (barrel type) with brass polished MS screws complete:
25 BS 8.65 Providing and fixing bright finished brass door handles with brass polished MS screws complete:
26 BS 8.158 Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc complete. 43.00 each
27 BS 9.3 Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.
9.3.1 Electric resistance or induction butt welded tubes Grade-250 25790.77 Kg
28 BS 9.6 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
9.6.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 271.60 Kg
29 BS 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer. 1986.00 kg
30 BS 9.57 Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete.
9.57.2 SS Grade 304 949.41 kg
31 BS 9.47 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:
31.1 9.47.1 For fixed portion 2032.54 kg
31.2 BS 9.47.2 For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately). 2667.52 kg
32 BS 9.51 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item):
32.1 9.51.1 With float glass panes of 4 mm thickness 7.56 sqm
32.2 9.51.2 With float glass panes of 5 mm thickness 371.86 sqm
33 BS 9.27 Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets,side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring.
9.27.2 80x1.20mm M.S. Laths 736.81 Sqm
34 BS 9.28 Providing and fixing 27.5cm long wire spring for rolling shutters. 62.00 Each
35 BS 9.29 Providing and fixing M.S. sheet top cover for rolling shutter
9.29.2 1.20mm thick 211.53 Sqm
36 BS 9.30 Providing and fixing ball bearing for rolling shutters. 248.00 Each
37 BS 9.31 Providing and fixing mechanical device chain and crank operation for operating rolling shutters. 62.00 set
38 BS 9.60 Designing, providing and fixing aluminium frame work made of special aluminium section on building face with M.S. angle iron brackets fixed on RCC structure with S.S. hold fasteners, including providing and fixing two sided structural adhesive tape of appropriate grade (NORTON or equivalent), on aluminium sections for fixing aluminium/ glass panel, sealing on periphery of frame work, by providing EPDM gasket, silicon weather sealant between aluminium frame and building structure including hire charges of double scaffolding complete. 9564.94 Kg
39 BS 9.61 Providing and fixing aluminium composite panels in approved panel sizes, thickness and shape on aluminium frame work on face of building. (Frame to be paid separately)
9.61.2 4mm thick 2732.84 sqm
40 BS 9.63 Providing and fixing clear float toughened glass door or partition in required thickness frameless in appropriated sizes inclusive of edge molding polish and making required size slot or hole for patch fitting/hardware etc. The glass to be assembled together with patch fitting and hardware in proper alignment with all labour tools and tackles etc complete. (Patch fittings and hardware to be paid for separately).
40.1 9.63.1 12 mm thick for door/partition 14.40 sqm
40.2 9.63.3 6 mm thick for glazing etc. 33.96 sqm
41 BS 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.2 In Cement mortar 1:4 (1 cement : 4 fine sand) 4077.68 sqm
42 BS 11.2 Providing and making 12mm thick cement plaster of mix:
11.2.4 In Cement Mortar 1:6 (1 cement : 6 fine sand) 6062.82 sqm
43 BS 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand) 5376.01 sqm
44 BS 11.5 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: 65.04 sqm
45 BS 12.7 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.
12.7.2 Size above 200x300mm 773.20 sqm
46 BS 12.9 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.
12.9.2 Size above 300x300mm 177.08 sqm
47 BS 12.65 Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm
12.65.2 Pigment Coloured (rubber mould) precast interlock concrete blocks 2515.65 Sqm
48 BS 12.66 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545:2021 (Product such as Birla wall care, Asian trucare,JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work. 213.90 m
49 BS 12.79 Providing and laying DOUBLE/MULTI CHARGE (minimum 2.0mm thick layer) VITRIFIED floor tiles with water absorption less than 0.05% and conforming to IS:15622-2017 of approved make in all colours and shades and size mentioned below (+/- 10 mm), laid on 20mm thick cement mortar 1:4(1 cement:4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.
49.1 12.79.1 Size 600x600mm thickness 9 to 10mm 1612.47 sqm
49.2 12.79.2 Size 800x800mm thickness 9 to 10mm 349.23 sqm
50 BS 12.47 8 mm thick Table rubbed polished Granite stone tile flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete.
12.47.2 Granite stone black 1155.58 sqm
51 BS 12.46 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m).
12.46.1 Granite stone grey/pink 310.49 sqm
52 BS 12.44 Extra for nosing in Granite stone for treads. 456.40 M
53 BS 13.6 15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish.
53.1 BS 13.6.1 Granite stone grey/pink 139.38 sqm
53.2 BS 13.6.2 Granite stone black 27.60 sqm
54 BS 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545:2021 (Product such as Birla wall care, Asian trucare,JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work. 15320.02 sqm
55 BS 14.64 Providing and applying Premium plastic emulsion paint with roller application minimum three coats applied @ 0.75 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -1 Class D & C ( Glossy and Semi Glossy Finish) of required shade (Product such as Asian Apcolite Premium , Dulux Super Cover, Berger Easy Clean Nippon Breezee Metex Gold, Opus I 50 / Calista) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(with 3 year Warranty) 9944.02 sqm
56 BS 14.68 Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex ,Dulux Weather Shield Prima E900, Berger Weathercoat Antidust, Nerolac Everlas Excel, Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty. 5376.01 sqm
57 BS 14.72 Providing and applying Glossy finish Enamel paint mimimum 2 Coats in al surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel Dulux Promise Premium Enamel Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work. 4025.43 sqm
58 BS 18.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required :
18.1.3 White Orissa pattern W.C. pan of size 580x440 mm 26.00 each
59 BS 18.4 Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
18.4.3 White wall hung type 25.00 each
60 BS 18.13 Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete:
18.13.2 Flat back type urinal of size 460x380x250mm 42.00 each
61 BS 18.17 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required :
18.17.5 White Oval or round size 550x400mm. 33.00 each
62 BS 18.76 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete.
62.1 18.76.2 110 mm dia pipe. 1310.00 meter
62.2 18.76.3 150 mm dia pipe. 1280.00 meter
63 BS 18.77 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
63.1 BS 18.77.1 Tee/ Tee with door/ Bend 45°/ Bend 90°
63.4 BS 18.77.6 Nahani trap 110x75mm 110.00 each
64 BS 19.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
64.1 BS 19.6.1 15 mm nominal outer dia pipes 990.00 meter
64.2 BS 19.6.3 25 mm nominal outer dia pipes 1870.00 meter
64.3 BS 19.6.5 40 mm nominal outer dia pipes 1195.00 meter
64.4 BS 19.6.6 50 mm nominal outer dia pipes 60.00 meter
65 BS 19.14 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required:
65.1 BS 19.14.2 Long nose bib cock (500 grams) 129.00 each
65.2 BS 19.14.6 Stop cock (concealed) (600 grams) 140.00 each
66 BS 19.15 Providing and fixing stainless steel drain jali of approved make/quality. 140.00 each
67 BS 19.16 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end):
67.1 BS 19.16.1 25 mm nominal bore 51.00 each
67.2 BS 19.16.3 40 mm nominal bore 42.00 each
67.3 BS 19.16.4 50 mm nominal bore 5.00 each
68 BS 19.17 Providing and fixing ball value (brass) of approved quality, High or low pressure, with plastic floats complete
19.17.3 25 mm nominal bore 66.00 each
69 BS 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 35000.00 Litre
70 BS 19.48 Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 1.00 each
71 BS 20.29 Providing and constructing brick masonry chamber for underground pipe and bends with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand) RCC cover of suitable size and 75mm thick with 1:1.5:3 mix (1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) including reinforcement 8mm dia bars at 150mm both ways and MS hooks for lifting, including foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
71.1 BS 20.29.1 Inside dimensions 450x600 mm and 45 cm deep for single pipe line : 33.00 each
71.2 BS 20.29.3 Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : 33.00 each
72 BS 22.2 Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 5 km (earth measured in stacks will be reduced by 20% for payment). 115.51 cum
73 BS 22.3 Supplying and stacking sludge at site including royalty, loading, unloading and carriage upto 10 km (sludge measured in stacks will be reduced by 8% for payment). 57.76 cum
74 BS 22.13 Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). 57.76 cum
75 BS 22.25 Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand:
75.1 BS 22.25.1 Hedges like Alife, Dorenta, Tikoma etc 1370.00 Each
75.2 BS 22.25.2 Furn like Arica, China etc (3 year old) 655.00 Each
75.3 BS 22.25.3 Hibiscus (Flower)/ Rose 960.00 Each
76 BS 23.1 Supply, erection, jointing, testing & commissioning of "C" Class MS pipes (as per IS: 1239) including necessary specials such as tees, bends, flanges reducers etc., complete on wall/ ceiling. The pipes to be erected on wall or suspended from beams, RCC roof slabs with suitable size MS bars/ angle irons including painting of metal part except pipe line.
77 BS 23.2 Painting for M.S. pipe with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation.
78 BS 23.4 Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS : 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required.
BS 23.4.2 100 mm dia 6.00 each
79 BS 23.5 Supplying, fixing, testing and commissioning of flanged butterfly valve PN 1.6, with Bronze/ Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS: 13095 of following sizes as required..
BS 23.5.2 100 mm dia 4.00 each
80 BS 23.11 Providing and fixing pressure switch with suitable for 1-10 Kg/cm2 including 12/15 mm Ø isolation valve, G.I. nipple, elbow, electrical connections setting of Cut-In and cut-Off pressure complete in all respects and in an approved manner. 4.00 each
81 BS 23.12 Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-21 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc. as per requirement in approved manner. 4.00 each
82 BS 23.18 Supplying and fixing single headed internal hydrant valve with instantaneous Gun metal couplings of 63 mm dia with cast iron wheel ISI marked conforming to IS: 5290 (Type - A) with blank Gunmetal cap and chain as required.
HYDRANT VALVE 8.00 each
83 BS 23.22 Supplying and fixing 63 mm dia, 15 mtr long RRL hose pipe with 63 mm dia Male and Female Stainless Steel-IS: 3444 Grade-1 couplings duly binded with GI wire, rivets etc. conforming to IS: 636 (Type -A) as required.
RRL hose pipe 10.00 each
84 BS 23.24 Supplying & fixing 63 mm dia Stainless Steel IS: 3444 Grade-1 branch pipe with 20 mm dia (nominal internal) Gun Metal nozzle conforming to IS: 903, suitable for instantaneous coupling connection to connect hose pipe coupling as required.
branch pipe 10.00 each
85 BS 23.25 Supplying and fixing of MS hose cabinet box of made of 2 mm thick MS sheet and 40 x 40 x 5mm angle iron with front openable cover having 6 mm thick glazed glass viewing window i/c necessary locking arrangement, on existing wall/ brick platform etc complete as required.
23.25.2 Size 900 mm x 600 mm x 500 mm 10.00 each
86 RS 8.4 Retro- reflectrorized Traffic signs as per Clause 801 Providing and fixing of retro- reflectrorized cautionary, mandatory and informatory sign digitally printed over reflectrorized sheeting of required grade confirming to ASTM D 4956 including covering with transparent sheeting (lamination sheeting) to protect from fading and damage due to wheather effect as perClause 6 of IRC:67- 2022 made of retro-reflective type sheeting fixed over Aluminum/ Aluminium Composite Material (ACM) sheeting including application of fluorocarbon coating applied on exposed surface of aluminium to ensure corrosion resistance, supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, as per approved drawing and painting all exposed components of the signs and supports with primer and 2 coats of epoxy paints or powder coating and the part of post below ground shall be painted with 3 coats of redoxide paint as per clause 7.2 of IRC:67- 2022. (Note: The details of manufacturer, type of sheeting, month and year of installation, project details and other details along with QR code as detailed in clause 13.2 and Annexure-VII of IRC:67-2022 shall be printed on back side of the sign board.)
A Made of Class-C Micro Prismatic Grade Sheeting of Type XI confirming to Table 6.9 of IRC:67-2022 (for National Highways and State Highways)pe XI
a) With Aluminium Sheeting of 2 mm thickness
vi 900 mm high octagon 3.00 Each
b With Aluminum Sheeting of 1.5 mm thickness
iii 600 mm x 600 mm square 4.00 Each
87 RS 8.6 Direction and Place Identification signs upto 0.9 sqm size board as per Clause 8.1. Providing and erecting direction and place identification retroreflectrorized sign Digitally Printed over reflectrorized sheeting of required grade confirming to ASTM D 4956 including covering with transparent sheeting (lamination sheeting) to protect from fading and damage due to wheather effect as per IRC:67-2022 made of retro-reflective type sheeting fixed over Aluminum sheeting / Aluminium Composit Material (ACM) Sheeting including application of fluorocarbon coating applied on exposed surface of aluminium to ensure corrosion resistance, supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing and painting all exposed components of the signs and supports with primer and 2 coats of epoxy paints or powder coating and the part of post below ground shall be painted with 3 coats of redoxide paint as per clause 7.2 of IRC:67-2022. (Note: The details of manufacturer, type of sheeting, month and year of installation, project details and other details along with QR code as detailed in clause 13.2 and Annexure-VII of IRC:67-2022 shall be printed on back side of the sign board.)
B Made of Class-B High Intensity Micro Prismatic Grade Sheeting of Type IV confirming to Table 6.6 of IRC:67- 2022 (for MDR) 12.00 sqm
88 RS 8.20 Painting Lines, Dashes, Arrows etc on Roads in Two Coats on New Work (Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control )
(i) Over 10 cm in width 241.88 Sqm
89 RS 12.6 Providing and planting of 3‟0” to 4‟0” heighted wasingtonia, filipheria/bismarkia novelist plam plants with 1‟6” x 1‟6” depth pit formation and soil preparation, (Mixing organic manure and plant‟s protection insecticide). Up to 4 month maintenance. 42.00 Each
90 RS 12.7 Providing and planting of 4‟0” to 5‟0” heighted Ficus prestige/Blackiana plants with 1‟6” x 1‟6” depth pit formation and soil preparation, (Mixing organic manure and plant‟s protection insecticide). Up to 4 month maintenance. 42.00 Each
91 ELE 1.7 Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 Sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Liqhtpoints / Ex Fan points
91.1 ELE 1.7.1 Short Point 55 Point
91.2 ELE 1.7.2 Medium Point 146 Point
91.3 ELE 1.7.3 Long Point 127 Point
Twin control liqht point
92 ELE 1.8 Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 20 Point
93 ELE 1.9 Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 70 Point
94 ELE 1.11 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
94.1 ELE 1.11.3 Long Point 14 Point
94.2 ELE 1.11.4 Extra Long Point I 39 Point
94.3 ELE 1.11.5 Extra Long Point II 36 Point
94.4 ELE 1.11.6 Extra Long Point III 21 Point
Sub Main in Concealed PVC Conduit
95 ELE 1.13 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
95.1 ELE 1.13.1 3 X 1.5 sq. mm in 20mm conduit 1785 Metre
95.2 ELE 1.13.2 3 X 2.5 sq. mm in 20mm conduit 770 Metre
95.3 ELE 1.13.3 6 X 2.5 sq. mm in 25mm conduit 910 Metre
95.4 ELE 1.13.4 9 X 2.5 sq. mm in 32mm conduit 245 Metre
95.5 ELE 1.13.6 3 X 4 sq. mm in 25mm conduit 420 Metre
95.6 ELE 1.13.7 3 X 6 sq. mm in 25mm conduit 35 Metre
96 ELE 3.12 Supplying and drawing following pair 0.5 mm FR PVC insulated copper conductor, unarmored telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification.
3.12.2 2 Pair 208 Metre
97 ELE 3.14 Supplying and drawing UTP 4 pair Cat 6 LAN wire in existing surface/ concealed Steel/FRLS PVC conduit as per specification. 280 metre
98 ELE 1.15 Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5)
99 ELE 4.4 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification.
99.1 ELE 4.4.2 100mmX75mm (3 Module) 3 Each
99.2 ELE 4.4.4 200mmX75mm (6 Module) 6 Each
100 ELE 4.5 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as per specification.
100.1 ELE 4.5.3 3 Module 3 Each
100.2 ELE 4.5.5 6 Module 6 Each
101 ELE 5.4 Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification.
101.1 ELE 5.4.1 5/6 amps one way switch 8 Each
101.2 ELE 5.4.4 15/16 amp switch 6 Each
101.3 ELE 5.4.5 3 pin 5/6 amp socket outlet 8 Each
101.4 ELE 5.4.6 6 pin 15/16 amp socket outlet 6 Each
101.5 ELE 5.4.9 Fan regulator (two module size) electronic stepped type moving all rounds 140 Each
101.6 ELE 5.4.15 Telephone socket outlet 10 Each
101.7 ELE 5.4.17 Computer Outlet Jack 13 Each
101.8 ELE 5.4.20 Ceiling rose 3 pin 5 amp 24 Each
102 ELE 5.6 Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification. 10 Each
Sub Head 2 : Accessories, Luminaires and Fans
103 ELE 6.71 Supplying, installation , testing and commissioning of following recess mounted DALI/0-10volt Analogue dimmable LED/COB Downlighter with Die cast housing made of aluminum and white. Powder coated finish. Diming should be Based LED shall having LM80 complied as per L70 standard LEDs minimum tested for 10,000 burning hours with 3000-6000K CCT with minimum life cycle 50000 hrs burning hours at 50˚C. Driver shall be 3 stage Constant Current Constant Voltage with voltage range of 150-270V AC. Driver Power factor shall be 0.95 and above and THD shall be less than 10%.
103.1 ELE 6.71.3 18 watt 175 Each
103.2 ELE 6.71.4 20 watt 224 Each
103.3 ELE 6.71.5 30 watt 17 Each
103.4 ELE 6.71.7 50 watt 22 Each
104 ELE 6.88 Supplying , installation , testing and commissioning for the following LED RGB / RGBW Linear wall washer luminaire for façade lighting with aluminium extruded housing of following wattage . Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX / Ethernet based control . The beam angle of the fitting shall be narrow , medium , wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any seperate power supply from 100 to 270 V AC , 50 Hz , power factor >0.9 . Fixture shall be suitable to operate at ambient temperature range of -10 Degree C to +50 Degree C and shall be IP 65 and IK 06 rated . Lifetime should be at atleast L70:50000 burning hours at 50 Degree C . Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables , water proof connectors etc as required.
6.88.2 35-40 watt 21 Each
105 ELE 6.16 Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt.
6.16.2 36 watt, size 600 x 600mm 140 Each
106 ELE 6.18 Supplying, installation, testing and commissioning of following COB LED Spot Light fitting complete with Electronic Driver Heat sink Capacitor and all other accessories including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt.
6.18.5 40 watt 25 Each
107 ELE 6.26 Supplying, installation, testing and commissioning of following LED Signage entry/exit having minimum size 300mm (L) x 200mm (H) x 45mm (W), fitting complete including built in battery backup for 2 hour with Electronic Driver Heat sink Capacitor and all other accessories, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. IP-20
6.26.2 Double sided LED Signage 14 Each
ITC fluorescent fitting with down rods:
108 ELE 6.4 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, including connection, earthing etc. complete as per specification. 70 Each
109 ELE 6.6 Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9
6.6.1 300 mm sweep 18 Each
110 ELE 5.9 Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification. 70 Each
Sub Head 3 : Switchboards
111 ELE 9.4 Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator)
111.1 ELE 9.4.1 4 way Double door 1 Each
111.2 ELE 9.4.2 6 way Double door 3 Each
111.3 ELE 9.4.3 8 way Double door 3 Each
112 ELE 9.20 Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.
ELE 9.20.1 40 amps 4 Each
ELE 9.20.2 63 amps 4 Each
113 ELE 9.22 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.
113.1 ELE 9.22.2 40 amps 4 Each
113.2 ELE 9.22.3 63 amps 4 Each
Sub Head 4 : Earthing
114 ELE 12.13 Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification. 70 Metre
115 ELE 12.17 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as per specification. 455 Metre
Sub Head 5 : Cable and cable management
116 ELE 15.3 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1).
117 ELE 15.5 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1).
117.1 ELE 15.5.13 4 x 10 sq. mm. 245 Metre
117.2 ELE 15.5.14 4 x 16 sq. mm. 175 Metre
117.3 ELE 15.5.15 4 x 25 sq. mm. 35 Metre
118 ELE 15.13 Supplying and laying following sizes one number FRLS PVC insulated, PVC sheathed, steel armoured, copper conductor control /power cable of 1.1 KV grade in exiting PVC/ GI pipe etc as per specification and IS: 694 (2010).
15.13.3 6 x 1.5 sq. mm 210 Metre
119 ELE 1.15 Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5)
119.1 ELE 1.15.2 25 mm 105 Metre
119.2 ELE 1.15.3 32 mm 105 Metre
BRASS COMPRESSION GLAND
120 ELE 15.24 Supplying and making end termination with brass compression gland and copper lugs for following size armoured copper conductor power cable of 1.1 KV grade as per specification.
a) 15.24.1 2 X 4 sq. mm (16 mm) 8 Each
121 ELE 18.1 Supplying and installing following size powder coated, perforated M.S. cable trays with perforation not more than 17.5% rigidly suspended from the ceiling with M.S. suspenders at a distance not more than 2.5 metre and near every junction/ joint etc complete as per specification.
18.1.2 150 mm width X 50 mm depth X 1.6 mm thickness 164 Metre
122 ELE 9.16 Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.
122.1 ELE 9.16.3 40 amps 5 Each
122.2 ELE 9.16.5 63 amps 5 Each
123 ELE 10.9 Providing and fixing metal clad, TP&N 4 pole automatic change over switch unit, 415/500 volts, including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification.
10.9.2 160 amps 1 Each
124 ELE 6.58 Supplying, installation, testing and commissioning of Acrylic LED light (a) Specification of Acrylic 3 mm thick x 3" width x 4" depth *(imbose) (b) Specification of LED modules:- Each Moduel should have 6 Nos LED of 1 watt 270.00 Sqft
125 ELE 6.61 Fabrication and installation of angle iron including angle size 50 mm x 5 mm thick with labour charges including materials as per specification 1080.00 Kg
126 ELE 6.62 Providing and fixing aluminium composite panels in approved panel sizes, thickness and shape on aluminium frame work
6.62.1 4 mm thick 50.19 Sqm
127 ELE 7.19 Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. (Only face area is to be measured)
127.1 7.19.1 Upto 300 mm deep 4.00 sqm
128 ELE 7.20 Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification.
129 ELE 9.1 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and lcs = 100 % lcu.
129.1 9.1.3 3 pole MCCB, 25-100A, Adjustable Thermal Release, 18KA 1.00 Each
129.2 9.1.6 3 pole MCCB, 160A, Adjustable Thermal - Magnetic Release, 25KA 1 Each
130 ELE 9.11 Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.
9.11.2 6 amps to 32 amps 142.00 Each
131 ELE 10.18 Providing and fixing penal mounting following rating analog type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification.
132 ELE 10.13 Providing and fixing 3 pole, 415/ 500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification.
133 ELE 10.15 Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per spee ificatio n.
134 ELE 10.20 Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification.
134.1 10.20.1 Analog type 1.00 Each
134.2 10.20.2 Digital type 1 Each
135 ELE 10.22 Providing and fixing following Time switch (timer) in existing panel including connection, testing and commissioning as per specification.
135.1 10.22.2 Analoge type 1.00 Each
136 ELE 10.17 Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification. 5.00 Each
137 ELE 10.21 Providing and fixing penal mounting selector switch in existing cubical panel including, connections, testing and commissioning etc. as per specification.
137.1 10.21.1 For voltmeter 1.00 Each
137.2 10.21.2 For ammeter 1.00 Each
138 ELE 12.19 Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification:
138.1 12.19.1 With 3 metre long GI Pipes and 50 kg back filling compound. 4.00 Each
139 ELE 12.5 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification. 15.00 Metre
140 ELE 19.8 Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 4mm thick anchor plate, 4 nos 24mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3)
19.8.1 9 metre high, dia 155mm at bottom and 90mm at top, base plate size 260 x 260 x 16mm, foundation bolts 750mm long 35 Each
141 ELE 19.12 Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification. 35 Each
142 ELE 19.11 Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification.
19.11.7 9 metre High 35 Each
143 ELE 19.9 Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification.
143.1 19.9.3 single Over Hang 1.50 metre Long 30 Each
143.2 19.9.7 Double Over Hang 1.50 metre Long 5 Each
144 ELE 15.1 Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1).
15.1.23 4 x 16 sq. mm. 990 Metre
145 ELE 15.28 Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as required.
15.28.3 16 sq. mm 35 Each
146 ELE 3.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit /PVC casing caping as per specification and IS: 694 (2010)
3.11.3 3 x 1.5 sq. mm 395 Metre
147 ELE 19.16 Supplying and fixing water tight terminal box made of 1.6mm thick M.S. sheet with detachable gland plate in bottom, hinged front open able cover, rubber gasket, having 1 Nos 4way connector and 1 No SPMCB inside the box for cable connection, fixed to pole with 2 Nos clamp made from 40x3mm M.S. flat with 2 No nut bolt dully painted with 2 coat of red oxide paint and 2 coat aluminium paint complete as per specification.
19.16.2 30x20x15 cms. 35 Each
148 ELE 6.28 Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 5 KV surge protection on pole bracket complete as required and furnishing 2 Yrs Guarantee certificate from manufacturer.
6.28.8 90 watt 40 Each
149 ELE 12.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required. 4 Set
150 ELE 9.12 Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.
9.12.2 6 amps to 32 amps 35 Each
151 ELE 7.10 Providing and fixing metal clad, TP&N switch fuse unit (re-wirable), 415/500 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately).
7.10.2 63 amps 35 Each
152 ELE 14.1 Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification.
14.1.1 63 mm outer dia and 50 mm Inner dia 185 Metre
153 ELE 15.3 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HOPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1).
154 ELE 15.23 Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable 0f 1.1KV grade as per specification.
155 ELE 12.18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ concealed conduit/ submain wiring/ cable as required. 50 Metre
156 ELE 31.12 Painting of following height steel tubular poles with two coat of aluminium paint of approved brand including cleaning the surface as per specification:
31.12.2 Above 6 metre and upto 8 metre 35 Metre
157 ELE 19.21 Supplying erection testing and commissioning of hot dipped galvanised (single dip, minimum 86 micron) 25 metre High mast pole on existing RCC foundation with all accessories and equipments, main detailed as below to withstand max wind pressure as per IS 875 Part-3: a) HM shaft made of approved no of sections (not more than 3) having suitable sectional lengths with slip joints between sections without any circumpherencial welding sheet thickness 3 mm top & 4 mm middle and bottom section, nominal dia 460mm on bottom and 150 mm on top, base plate 25mm thick 670mm dia, PCD of foundation bolts 590mm. b) Double drum winch with Integral single phase power tool (electrical) for lowering & raising of lantern carriage on high mast with separate handle for manual operation of winch with a torque limiting device for safe locking of carriage. c) Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box. d) Top pulley assemble with weather proof cover. e) 2 Nos suitable length and size stainless steel wire ropes (minimum 6mm dia and 7/19 construction) for lowering & rising of lantern carriage. f) Suitable size and length multicore flexible copper power trailing cable (minimum 3 core 4 Sqmm) g) Hinged service door in base section h) Base plate earthing terminal. i) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. j) Lightning conductor finial made of 25mm dia 300 mm long G.I.tube having single prong. k) Anchor plate, tem-plates, GI foundation bolts min 12 Nos of 30 mm dia 850 mm long (EN 8 Grade) along with nuts washers etc. (RCC fooundation and luminaries will be paid separately) 1.00 Each
158 ELE 19.23 Designing and providing suitable and approved size RCC foundation for 12- 30 mere high mast including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification including laying and fixing HM foundation bolts with tam plates but excluding the cost of foundation bolts with tam plates etc complete as per specification. 10.00 cum
159 ELE 6.29 Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio 2 120 lumens /watt.
160 ELE 19.1 Supply of "H" beam steel pole as per IS specifications in standard length for over head line work:
19.1.2 "H" beam steel pole 152x152x7x12 mm standard weight 37.1 kg / metre 22.00 Metre
161 ELE 20.1 Supply and fixing following overhead line accessories.
20.1.12 DC cross arm made of MS channel 100x50x5 mm @ 9.56 kg/m 40.00 Metre
162 ELE 20.6 Supplying and erection of angle/channel iron cross arms/ bracket/ other fitting of approved size and shape including drilling of holes for insulator pins, bolts and nuts etc as per specification. 70.00 kg
163 ELE 20.19 Supplying and fixing approved make 11 KV glazed porcelain disc type insulator with tension hardware on existing pole/ support/ cross arm channel as per specification complete: 3.00 Each
164 ELE 20.20 Supplying and erection of 11 KV gang operated air break switch on existing two pole structure with insulators and all other accessories complete including locking arangement as per specification. 1.00 Set
165 ELE 20.21 Supplying and erection of 11 KV D.O. fuse unit on existing two pole structure with insulators and all other accessories complete including locking arangement as per specification. 1.00 Set
166 ELE 20.22 Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as per specification. 1.00 Set
167 ELE 20.23 Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as per specification. 1.00 Set
168 ELE 20.32 Supply and erection standard ACSR (aluminium conductor steel reinforced) confirming to IS 398-1961 of approved make at existing insulator at height upto 14m from ground level including stringing, binding with insulator, jointing wherever required, jumpering, tearing off connection etc complete etc. as per specification including clearing off obstacle if any:
20.32.4 Raccoon 61114.09mm dia with calculated aluminium area 78.83 sq.mm, weight 319 kg/ km (198 amps) 0.20 Km
169 ELE 20.33 Supplying and erection DANGER BOARD made MS sheet duly painted and maked as per IE rules and specification. 1.00 Each
170 ELE 21.1 Supplying and installation of outdoor type Transformer ONAN type with copper winding having following continuous KVA rating, 11 /0.415 KV, 3 Phase 50 Hz Vector group DYn-11, (Online tap changer) tapings in steps of ± 2.5%, ± 5%, --7.5% with oil conservator, silica gel breather having connecting terminals on HV side suitable for bare conductor/HT cable connection, cable end box on medium voltage side suitable for 1.1 KV single / 3½ core cable (upto 300 sq mm)/bus ducting arrangment and confirming to IS:1180 Part-2 Level 3, on existing double pole structure or Brick /CC/RCC platform with all fittings, accessories, filled with filtered transformer oil including testing and commissioning etc. complete as per specification
SAFETY EQUIMENTS
171 ELE 21.5 Providing and erecting floor mounted sand/ water bucket stand for keeping 4 nos. of fire bucket, 1500 mm in length and 900 mm in height made out of 30 X 30 X 4 mm angle iron welded with 4 hooks and duly painted with one coat of zinc cromate primer and 2 coat of synthetic enamel paint of post box red colour etc complete. 1.00 Each
172 ELE 21.6 Supplying G.I. Fire buckets with round bottom having at least 9 lit. capacity duly painted with one coat of zinc cromate primer and 2 coat of synthetic enamel paint of post box red colour and filled with dry sand and kept on provided wall hook or stand etc complete. 1.00 Each
173 ELE 21.8 Supplying and erecting chain link mesh fencing for electric sub-station switch yard of 2.5 m approx. height from ground level using angle iron size 50 X 50 X 6 mm erected in C.C. foundation 15 X 15 X 40 cm deep at every 2 metre fitted with flat iron support of size 25 X 6 mm on top, bottom and mid way and chain link mesh 50 x 50 mm aparture and 4 mm dia G.I. hard wire securing and screwing with 2mm dia G.I. wire, G.I. staples, G.I.U-nails or steel pins to the angle iron at every distance of 30 ems, by iron studs complete duly painted with one coats of red oxide and two coats of approved colour paint.(Area of fencing i.e. height x length is to be measured) 3.00 sqm
174 ELE 21.9 Supplying and erecting MS gate of approx. size 3.0 m (W) x 2.0 m (H) in two laps for electric sub-station switch yard fencing frame made of angle iron size 50 X 50 X 6 mm on top bottom and sides fitted with flat iron support of size 25 X 6 mm on mid way horizontaly and square bar of size 8 mm at every 100mm vertically including 3 sets of heavy duty MS hinges and aldrop complete duly painted with one coats of red oxide and two coats of approved colour paint. 1.00 sqm
175 26.17 Supply and erecting of following ISi marked Fire extenguishers on wall/ column including erecting bracket etc complete.
175.1 ELE 26.17.5 CO2 type Fire Extinguisher ISi marked confirming to IS:15683 :2018 Capacity 4.5Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shall comply with IS 15222. FIRE RATING:- 55B. Complete with Hose Assembly and horn, locking arrangement, operation manual, bracket with two screw and sleeve 1.00 Each
175.2 ELE 26.17.1 ABC Fire Extinguisher 9KG Nitrogen Store Pressure As per IS: 15683:2018 Body Sheet Not Less Then 2mm Thickness, CE Mark NRV Valve With ABC Powder 90% UL 299 FIRE RATING: 6A, 144B. With all accessories. 1.00 Each
176 ELE 22.7 Suppy, installation, testing & commissitioning and putting into operation and final testing of automatic lift complete with ARD and all standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) 1981and fulfilling following requirments on turn key basis. A. Type : Passenger lift B. Load : 13 passenger/ 884 Kg C. Speed : 1.5 metre per second D. Contol : AC2 E. Operation : Microprosser based simplex collective selective with/without lift attendent F. Total rise : About 9 mtrs G. Landings : 4 All on same side H. Floors served : G,1,2,3 I. Signals : Digital car position indicator, car travel direction indicator in car & at all landings J. Lift shaft size : About 2500 mm width X 1900 mm depth, finished with plaster (size as per actual site conditions) K. Lift car size : About 2000 mm width X 1100 mm depth L. Car entrance : Minimum Clear opening 900 mm wide X 2000 mm high protected with car door M. Landing entrance: Clear opening 900 mm wide X 2000 mm high protected with landing door N. Car door : Stainless steel/ Glass Door two pannel telescopic/centre opening flush type O. Landing door : Stainless steel/ Glass Door two pannel telescopic/centre opening flush type P. Door operation: Automatic electric power operated door with infra red protection Q. Car interior : Stainless steel pannel with hair line/ mirror/moon rock finish on all sides R. Car floor : Hard wood covered with PVC/ marblex tiles S. Car ceiling & lighting : Fluorscent lighting concealed by suspended false ceiling with plain acrylic diffuser. The frame of suspended false ceiling shall be of powder coated aluminium T. Car ventilation : Pressure fan with anodised aluminium grill U. Emergency lighting in car: Battery operated Emergency lighting in the lift car V. Intercom system : Battery operated Intercom system in lift car, machine room and control room W. Emergency alarm : Battery operated alarm bell system in lift car & contol room X. Position of machine room: Directly above the lift shaft Y. Electric power supply : AC 415 Volts 3 phase 50 Hz terminated in machine room Z. Fire man switch : Fire man switch at main landing termanal Modified E&M SOR 10.06.2026, Page- 2 Job
176.1 ELE 23.2 Supplying, installation, testing and commissioning of centrifugal type mono-block electric pump set for water supply system having following capacity three phase, 415 volts AC induction motor and pump including suitable channel iron base frame, suitable C.C. foundation and connection of suction and delivery line etc. as per specification.
23.2.3 7.5 HP, 650 LPM, 30 m head, suction size 80 mm, delivery size 65 mm 2.00 each
177 PHED 28.1 Carrying out the resistivity survey by VES method using Schlumberger configuration for locating the proper spot with three soundings for drilling of tube well within the selected Habitation, including photography, interpretation of resistivity data and submission of report in the desired format along with resistivity readings, necessary graph and photographs. 2.00 Per successful point
178 PHED 29.3 Drilling of perfectly vertical bore hole of a diameter suitable to receive 150 mm nominal diameter casing pipe upto desired depth below ground level inclusive of the labour charges for transporting, lowering and fixing of 150 mm nominal diameter and fixing of 150 mm nominal diameter M.S./ G.I. / U.P.V.C. casing pipe inside the bore hole including all works pertaining to drilling such as transportation, installation and removal of drilling machine etc.complete.
178.1 a) In all type of collapsible strata consisting of soils, clays, sand , moorum, gravel, boulders etc. 90.00 Mtr
178.2 b) In all types of rocks. 160.00 Mtr
179 PHED 29.9 Providing and fixing of well cap on top of the tube well for protection
C 150 mm dia. 2.00 each
180 PHED 29.10 Construction of concrete block over dry tube wells for protection of size 0.45m x 0.45m x0.45m in M-15 cement concrete mix complete work. 2.00 each
181 PHED 3 (page -356) ISI Mark 32 mm dia. G.I. riser pipe in 3 meter length socketed on one end as per I.S. 1239 (Part I) 1990 up-to- date amendments and socket as per I.S. 2062/1990 up-to-date amendment, Part-C, General Note: 27.28.10 220.00 Mtr
182 PHED 6 (page -356) ISI marked G.I. casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per I.S.: 1239 (Part-2) 1992 with IV th revision ( Up-to date amendments), Part-C, General Note: 27.28.10
CM casing pipes, 150 mm dia 100.00 Mtr
183 PHED 34.20.105 Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/Nylonwireropeandconnection cable.
(xv) 2 H.P. with 25 stages, Head Mt. 163-58 Discharge LPM 10-45 2.00 each
184 PHED 34.20.107 (354) Supplying and laying of submersible flat cable ISImarked 3 core copper wire of suitable size with proper clamping of approved make.
2.5 Sq.mm.multi strand 250.00 Mtr.
185 PHED 6.1 Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete. Pipes and sockets conforming to IS:1239/2011 Part- II.
50mm dia (Medium) 40.00 R Mtr.
186 PHED 6.3 Providing and fixing following gate (full way) valves tested to 300lbs/Sq inch or 21.00 kg/sq.cm. confirming to IS 778/ 1984 (Reaffirmed 2005) Class-I
50mm dia (Medium) 2.00 Each
C.M.O. Sub E. ARCHITECT
Ar. Rohit Marathe
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.02 MB
8752165693939208063_204243_1.docx
NIT • 0.20 MB
789743173357255754_204243_2.pdf
NIT • 0.97 MB
449773969405469848_204243_3.pdf
NIT • 0.67 MB
2980541493503711447_204243_4.docx
NIT • 0.06 MB
8270025272279078525_204243_5.doc
NIT • 0.07 MB
4662888799579187946_204243_6.docx
NIT • 0.03 MB
3935928253401624501_204243_7.pdf
NIT • 39.83 MB
4566377926647213840_204243_8.xlsx
BOQ • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .