Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC 60 MADHUVAN BANK COLONY ALWAR | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹34.8 L+₹1.2 L (3.67%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹35.5 L+₹1.9 L (5.74%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹36.5 L+₹2.9 L (8.72%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹40.8 L+₹7.2 L (21.6%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹38.8 L
EMD Value
₹77,700
Closing Date
9 Jan 2024, 6:00 pmClosed
CWE HISAR
HQ CWE HISAR HISAR MIL STN HISAR
SPECIAL REPAIR TO OR LIVING LINE BLDG NO P-39 AT OTM ACCN UNDER AOR OF AGE B/R-II AT ITARANA UNDER GE ALWAR
2023_MES_630856_1
CWE/HSR/ALW-40 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
ALWAR MILITARY STATION
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE ALWAR
₹77,700
1 Feb 2024
2 Dec 2023
12 Jan 2024
2 Dec 2023
9 Jan 2024
26 Dec 2023
Amount
Demolition cement concrete(unreinfored) as in ground floor and paving not exceeding 15cm thick below or above the ground level
Demolition of cement concrete (reinforced) in landing slab ,chullah hoods ,manhole covers , Roofs ,Floors, beams, stair case, landing, chajja and similar suspended work.
Demolition of brick work built in cement mortar or cement lime mortar including all quion arches
Taking down cement plaster on brick/stone/cement concrete surface of any description including racking out joints hacking for key scrubbing down with water complete all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutters frome the frames) n exc 1.5 but each complete all as specified & directed.
Taking down chowkhat frames with shutter without taking off shuttes from the frame exc 1.5 Sqm and not exc 4 Sqm each.
Taking down or up steel tubing and connections inculding cleaning for refixing or removal to store 15mm bore
Taking down or up steel tubing and connection inculding cleaning for refixing or removal to store 20mm bore .
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove incl brushing neat cement slurry with 3.00kg of cement per sqm.
M&L for mirror polished machine cut kota stone flooring 18 to 20 mm thick laid over with and including 15mm thick cement mortar srceed bed 1:6 set and jointed in neat cement slurry mixed with pigment to match the shed of the slab including rubbing polishing complete all as specified and as directed
M&L for mirror polished machine cut kota stone 18 to 20 mm thick laid over with and incl 10mm thick rendering in cm 1:4 as in skirting , dado, riser, step set and jointed in neat cement slurry mixed with pigment to match the shed of the slab including rubbing polishing and nosing the edges of stone slab complete all as specified and as directed
M&L for framed work as in doors or gates angle or other covering door, cooler stand etc to be prepared for handing or sliding with including either hooks and hinges or steel hanging dor fittings (exclusIve of steel or othr covering, running rails and guides) and hanging also fastening and fixing complete conforming to FE-290 Gde E-165.
M&L for mild steel work as in holdfasts, knee piece and similar small article confiraming to Fe 410-0 or Fe 310-0 complete all as specified
Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1, exc half brick but n.exc one brick.
S&F factory made 35mm thick flush shutter, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F factory made 35mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as spd and directed.
M&L for taking down old existing roof treatment and cleaning the roof surface by wire brushing and watering and applying a coat of cement slurry at the rate of 3Kg/Sqm on the roof surface complete all as specified and directed.
M&L for water proofing treatement to RCC roof slab including parapet comprising of following course of treatement/specified from bottom to top (a) Applying Bituminous primer @ 0.40 Ltr per sqm over plastered surfaces of roof including parapet surfaces. (b) Over the priming coat laying one layer APP based polymeric membrane of approved manufacturer, 3 mm thick weight not less 3.00 Kgs/Sqm over and including bitumenious hot bitumen 85/25 & uniformly embeded in during manufacturing process shall only be used & joints shall be sealed properly by torch application . side overlap should be 75mm and end shall be 100mm. For parapets, membrane shall be taken to a height of minimum 20cm and then inserted inside parapet in groove. The same shall be finished by a membrane flashing
M&L for 15 mm thick rendering in CM 1:4 on roof slab with mixed with water proofing compound @ 3% by wt of cement, finished the surface even and smooth in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane finished complete all as specified. Note :- (Polymeric membrane and WPC shall be meausred and paid seperately here-in-after)
Supply only water proofing compound
M&L for finishing of top surface of APP membrane by applying two coats of aluminium paint as per manufacturers instruction complete all as spd and direct.
Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner incl demolition old existing roof tiles complete all as spd and directed.
M&L for providing precast cement concrete (1:2:4) type B1, using 20mm graded crushed stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span,cills, steps, seismic and other similar bands, plinth courses, string courses , lacing courses, parapits and railings upto 60cm in height, copings/bed block, kneelers, apex stones, bed plates, kerbs not provided and the like including weathering slightly rounded or chamfered angles and throating as directed
S&F 15mm dia concealed galvanised iron tube medium grade with all fittings such as bends, elbows sockets, reduces etc and fixed to wall, ceiling or laid in floor with new fittings including cutting through wall floor etc :-complete all as spd.
S&F 20mm dia concealed galvanised iron tube medium grade with all fittings such as bends, elbows sockets, reduces etc and fixed to wall, ceiling or laid in floor with new fittings including cutting through wall floor etc complete all as spd.
Treatement for sunken portion is as follows :- (a) Demolition of lean concrete and other type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed. (b) Maintain the Sunken to a slope of 1:40 outward with 32mm dia GI pipe spout projecting at least 150 mm beyond outer face of wall. (c) Top of the sunken floor slabs shall be laid to a slope 1:40. The surface of RCC slab shall be made even and smooth by using extra cement while the concrete is still green. Coved fillet in PCC (1:2:4) type B0 of radius 75 mm shall be provided at the junctions of RCC slab and adjoining walls. (d) Floor and side walls upto the finished floor level shall be plastered with 15 mm thick CM (1:4) mixed with water proofing compound @ 3% by weight of cement. Over plastered surfaces, a layer of APP based polymeric membrane not less than 3mm thick, weighing not less than 3 kg per sqm, reinforced with polyster non- woven fabric (weighing not less than 150 gm per square metre) shall be laid by torch application over hot blown betumen primer 85/25. Side overlaps shall be 100mm and the ends laps shall be 150 mm and overlap joints shall also be sealed by torch application. (e) The sunken portion shall be filled with lean cement concrete (1:5:10), typeE2 using 40 mm brick aggregate after carrying out satisfactory testing of CI pipes / joints and slabs / walls by filling water for 72 hours. The sunken portion of Nahani / floor trap and pipe joints shall be embedded in PCC (1:3:6) blocks. (f) 32 mm dia GI spout shall be provided to drain out leakage, if any.
S&F in repair vitreous china squatting pan 'ORISSA PATTERN ' size 580mmx440mm 'white with integral foot rest (excluding flushing cistern and flush pipe ) including connection to trap and to flushing pipe anti syphonage pipe etc complete all as specified and as directed .
S&F in repairs vitreous china wash down water closet (Pedastal pattern) 'white (excluding flushing cistern and flush pipe incuding seat cover and Jet) including connection todrain or out going pipe and to flushing pipe anti syphonage pipe and making good to floor complete all as specified and as directed.
S&F in repair oval type vitreous china wash hand basin white colour of size 550mmx400mm fixed in granite slab etc including 32mm dia CP brass waste coupling fitting and union complete all as specified and as directed
S&F high density polythelene pipe (HDPE) of 32mm, pressure rating 6 Kgf/cm2 fixed to ceiling, floor etc complete all as specified and directed
S&F in repair vitreous china urinal half stall type white excluding flushing cistern , but including CP urinal spreader and waste pipe complete all as specified and directed
S&F in repair Vitrious china urinal partition of size 300mmx700mm
S&F in repair15mm dia bore stop /Angle valves cast copper alloy chromium plated with long shank complete all as specified and as directed.
S&F in repair 15mm dia conealed stop valve, cast copper alloy chromium plated, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe on for unions all as specified.
S&F repair chromium plated cast copper alloy with crutch and butterfly handle fancy type bib tap (Long Body) & cup 15mm dia bore complete all as specified and as directed.
S&F in repairs 10 ltrs capacity PVC low level flushing cistern complete with syphon handle lever, PVC bend including connecting to WC and fixing on walls with bracket complete all as specified and directed.
S&F in repair PVC connection 15mm dia and 450mm long with both ends brass fly nut complete all as specified and as directed.
S&F in repair 15mm dia bore cast copper alloy chromium plated fancy type pillar tap(Swan Neck) for with out cold & hot water complete all specified and as directed . Make : Prayag /Jaquar/hindware
S&F in repair tubuler towel rail 20mm dia D type ,60mm long between flanges (aluminium anodised)
S&F in repair Soap dish any type of chromium plated complete all as specified
S&F 1000 Ltr capacity of rotational moulded polyethylen water storage tank (Cylindrical vertical with closed tap) hoisted and fixed in position including 20mm float valve 20mm dia GI pipe medium grade washout pipe 450mm long with plug and 20mm dia GI pipe medium grade overflow pipe 600 mm long with fitting and including dismantling of old PVC water tankcomplete all as specified and as directed.
S&F in repair 20mm bore Gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed complete
S&F 75/80mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, incl taking down old existing pipe complete all as specified and directed.
S&F PVC (SWR) pipes of 110 mm nominal outside diameter double socketed in any length with rubber ring joints including all fittings/fixtures fixed on wall or in trenches or in floor incl taking down old existing pipe complete all as specified and directed.
S&F in repair PVC floor trap size 75mm dia out let with CP grating including connection to waste pipe with solvent cement complete all as specified and directed
S&F in repair PVC P or S trap 100mm dia out let waste pipe with cement jointing complete all as specified and directed
S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cemente.
S&F 110mm PVC(SWR) bends any radius complete all as specified and directed.
S&F PVC (SWR) 'Y' Junction double branch pieces equal or unequal 100mm bore
M&L for brick work with fly ash 'brick (old size brick) straight or curved on plan exc 6m mean radius built cement mortar 1:6 complete all as specified and as directed
M&L for brick work with fly ash 'brick in any radius built cement mortar 1:4, half brick thick wall complete all as specified and as directed
M&L for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work surace rendering is to be even and smooth with out using extra cement including mixing of water proofing compound @ of 3% by weight of cement complete all as specified and directed. Note WPC will measured and paid separately.
M&L for 15mm thick rendering in cement mortar 1:6 on other than fair faces of brick work surace rendering is to be even and smooth with out using extra cenent complete all as specified and directed
M&L for 5mm thick rendering in cement mortar 1:4 on ceiling surace rendering is to be even and smooth with out using extra cenent complete all as specified and directed
M&L applying 15mm thick plaster with polymer modified mortar fortified with SBR (Nitobond SBR 45 ) in proportion 1:3 by weight 5 litres Nit bond SBR 45 to added to 50 KG Cement with 13 litre water addition, finished surface to match with existing adjoining surface of ceiling, beams and alike complete.
M&L for Rough cast plaster on exterior walls applying the under coat of cement and sand morrtar 1:3 not less than 10mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12mm ) mixed with coarse sand and cement in the raio of 1:1:1 shall be applied and finished even. The mix of cement and sand shall made slightly wetter than normal for rendering to ensure that larger aggregate are thoroughly covered complete all as specified and directed by Engineer in Charge
M&L preparation of newly plasterd surface of wall and applying two coats of oil bound distemper white or tinted over and including 1mm thick Birla wall care putty complete all as specified and dircted
M&L for preparation of new plastered surfaces of walls and applying Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10sqm incl 1mm thick waall putty complete all as specified and directed.
M&L for preparation of newly plasterd surface of ceiling surface and applying two coats of white wash complete all as specified and dircted
M&L for Complete removal of existing treatment (White wash, colour wash, cement base paint, OBD or any other treatment) of wall by brooming down on steel wire brushing scrapping down smoke soot moulds, moss and efflorescent salts and trading oil greasy spot etc and applying two coats of oil bound distmper over and incl 1mm thick wall Care Putty on walls up to 15M height complete all as specified and directed
M&L for Complete removal of existing treatment (White wash, colour wash, cement base paint, OBD or any other treatment) of wall by brooming down on steel wire brushing scrapping down smoke soot moulds, moss and efflorescent salts and trading oil greasy spot etc M&L for preparation of new plastered surfaces of walls and applying Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10sqm incl 1mm thick waall putty complete all as specified and directed.
M&L for preparation of old surface of ceiling and applying two coats of white wash complete all as specified and directed
S&F Granite (of any type ) work 20mm thick (table rubbed and polished) in steps, jambs, pillars ,window cills,cooking platforms and like (including cutting for fixing of WHB, Sink etc) in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed
M&L non skid ceramic coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc, set and jointed in neat cement slurry and pointed in white and coloured cement to match coloured tiles including Screed bed of mortar 15mm thick for laying floor finishes CM (1:6) including dismantling old tiles complete all as specified
M&L for glazed ceramic colour tiles in vertical surface 450X 300X 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 10 mm thick rendering in CM (1:4), including dismantling old tiles complete all as specified and directed.
S&F factory made Box type steel window 1.25mm thick box type ERW hollow P section of size 60mm x25mm single rebated comprise of gauged skelton shutter ERW size 50mmx20mm and 1.25 mm thick with two openable leaf consisting two Nos sash bars of T- section 20mmx3mm welded to frame with one vertical mullion of ERW box type T- section of size 60mmx25mm and 1.25 mm thick including cutting holes and making good dismantled portion with PCC (1:2:4) type B-1 (four Nos for each window) including following fittings weled to frmae shutter:- (a) Hold fast 150mm long of 12mm x3mm made to shape -04 Nos per window. (b) Handle of z section 20mmx25mm, 100mm long - 01 Nos per leaf. (c) MS Tower bolt 150mm long -02Nos per leaf. (d) Z-section 20mmx25mm 100mm long 01 Nos per leaf. (e) MS pintol hinges of size 75mmx12mm-02 Nos per leaf. Note :- (i) Fabrication & fixing shall be as per TD Drawing (ii) Wire mess and painting shall be measured and paid separatly under respective items.
All as per item No.67 above but window with glazed shutter
S&F factory made steel ventilator (Box type) with side hung shutter including hinges, stel peg stay , handle and peg stay complete with glazing bars dovetailed or welded incl fixing of lugs in PCC 1:2:4 type B1 using 20mm graded sone aggregate and making good walls and ceils to match the existing complete all as specified and directed
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire taples complete all as specified and directed .
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 Sqm in each pane complete all as specified and directed.
S&F 3mm thick figured glass pinheaded type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
Dismantling structural steel work in cluding doors, gates but excluding framed truss etc.
S&F frame work such as grills,gratring etc,with ends of bars shouldered &/or riveted or forged into spikes,framed guard bars, barred iron door ladder,frame balusters,walk ways, railing,frame work or water tanks & SImilar work conforming to Fe-290 Gde E-165.
S&F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed colour PVC sheet & edges will be painted to match with printed sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing
S&F 100mm size stainless steel butt hinges medium weight cold rolled complete all as specified & directed.
S&F Aluminum anodised, barrel tower bolts of extruded section and fixed 150 mm long
S&F extruded aluminium alloy handles 125mm size fabricated type anodized ISI marked.
S&F 150mm long extruded Aluminium alloy handle complte all as specified & directed.
S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete
S&F 100 mm size mild steel butt hinges medium weight cold rolled complete all as specified & directed.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy complete all as specified and as directed.
S&F 25mm dia PVC Coated Curtain rod with designer knob fancy type with stainless steel brackets complete all as specified and directed.
S&F 150mm floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floor complete all as specified and directed
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed.
M&L for RCC work (Nominal mix) 1:2:4 type B-1 as in landing, cover slabs (for manholes etc) Chajjas, water troughs, managers, shelves and SImilar article with plain faces.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping and similar work.
M&L for TMT bars 10mm dia and over cut to length to shape required including cranking, bending spirally or hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9 mm dia all as specified.
M&L for providing post construction Antitermite treatment alongwith external wall below concrete or masonry apron using chemical emulsion @2.25 Ltr per linear meter including drilling and plugging hole etc in apron with cement mortar 1:2(1 cement 2 coarse sand)complete all as specified and as directed
M&L for Anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement 2 coarse sand ) to match the existing floors, complete all as specified and as directed.
M&L for 75 mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation filling and mass concrete as floor sub base complete all as specified and directed
M&L for machine pressed precast concrete interlocking coloured paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-25 grade and fixed with grey cement and pigment over and incl 20mm thick sand cussion incl dismantling old tiles complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in plinth protection path laid in panel surface finished even and fair using extra cement complete all as specified and as directed
Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth and getting out for sewage line as in soft/loose soil complete all as specified.
S&F for 75mm thick steel fibre reinforced (SFRC) man hole cover with iron frames (medium) complying to the standard specifications as mentioned in the IS 12592 BIS Standard, minimum load bearing capacity 5 ton/sqm, in square, rectangular or circular shape complete all as specified & as directed.
Demolition and breaking up of SWG drain pipes 150 mm internal dia and removing of rubbish to a distance n.exc 50 m complete all as specified.
M&L for Concrete bed for 150mmdia drain pipes laid to falls including packing under and haunching against the sides of pipe after they are laid & tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone agg.) complete all as specified and directed.
M&L for 150mm salt glazed stone ware drain pipes laid in trenches and jointed, all as specified and directed.
M&L for Cement concrete 1:4:8 TypeD-2 (using 40mm graded stone aggregate) in filling and mass concrete compete all as specified and directed.
Returning filling including spreading leveling watering and well ramming in layers n.exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing surplus excavated soil to a distance n.exc 50 m & depositing where directed at a level n.exc. 1.50 m above the starting point in soils complete all as specified and directed.
Taking down carefully copper/Aluminium point wiring for light/fan/socket/light fitting/power point and taking down of teak wood batten / PVC casing caping/PVC conduit/steel conduit and making good disturbed surfaces of walls/ceilings /floors etc incl dismentling of fittings.
M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor fire resistant low smoke (FRLS) PVC insulated and unsheathed cable 1100 Volts grade confirming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20 mm external dia) but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part-I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling including 1.5 mm FRLS PVC insulated unsheathed copper earth wire including sunken type pressed steel terminal boxes electro plated of suitable size with bakellite white/coloured top sheet cover 3.0 mm thick for one light point controlled by one way switch all as specified & directed.
All as per item No. 105 here-in-before but for one fan point controlled by one switch and regulator
All as per item No. 105 here-in-before but for one exhaust point controlled by one switch and regulator
All as per serial item No. 105 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.
All as per serial item No. 105 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per item No. 105 here-in-before but for one light point controlled two ,two way switches
All as per serial item No.105 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour.
Supply and fixing switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts.
S&F switch piano flush type single pole two way 5 Amps 230 Volts .
Supply and fixing switch piano, flush type, single pole, one way, 15 Amp, 230 Volts.
Supply and fixing socket outlet, 3 pin (with 2 pin outlet also), 5/6 Amp, flush type, 240 Volts.
Supply and fixing socket outlet, 2 in 1, 3 pin, 5 and 15 Amp, flush type, 240 Volts.
Supply and fixing ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified.
Supply and fixing stepped type electronic fan regulator, flush type and connecting up, ISI marked, 240 Volts.
Supply and fixing decorative ultra slim liner LED lighting fixture with extended poly carbonate environmental friendly, energy efficient suitable for 16W to 20W with LED tube of model E-LITE LED pride and connecting up, complete all as specified and directed.Make : Havells cat part No. LHEXBHP71N1W018 or equivalent of philips/Crompton Greaves/ bajaj/Wipro/GE
S&F LED type street-DRACO SERIES light luminaire 20 watt 230 V 50 Hz including all necessary fitting accessories and LED complete all as directed. Make: C&S Cat Part no. LTESS20WLED or equvalent Crompton Greaves /Wipro
Supply and fixing lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified.
Supply and Fixing LED Bulb energy saving 10/11 W complete all as specified and directed Make :- Havells/Crompton/Syska
S&F Sheet metal enclousure double door type ,suitable for fixing TPN with 200 Amps rated bus bar ,vertical DB 4 way TPN 415 Volts complete
Supply and fixing sheet metal enclosures double door type suitable for fixing MCB's, SPN with 200 Amps rated bus bar,8 way, 240 Volts.
S & F MCB 63 Amp, three pole & neutral, 415 Volt complete all as pecified & directed.
S & F MCB 32/40 Amp, single pole & neutral,240 Volt complete all as pecified & directed.
S & F MCB 6-40 Amp, single pole 240 Volt complete all as pecified & directed.
Supply and fixing 2nd class hard wood rectangular block open recessed of size 30cmx25cmx5cm depth with 3mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawl plug (4 Nos),for DB complete all as specified & directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & directed. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soil.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified.
M/L for brick work with FLY ASH BRICKS(As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed.
M&L for dry sand and punning for cushioning to under ground cable all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
S&F sub main wiring on and including passing through PVC conduit pipe 1100 Volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm and continuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm of green colour confirming to IS 694/1990 including taking down existing U/S sub main wiring. (Note: Two runs of cable with one run of earth wire and one run of PVC Coundit should measured as one length)
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & directed.
M/L for GI pipe ( Light grade ) for protection of LT cable fixed to walls/ poles/road crossing including clamps complete of 40 mm bore
AARSINFRATECH
GAR CONSTRUCTIONS
M/S GAURI CONSTRUCTION
M/s S Amarjit Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .