Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.9 L+₹42,611 (5.00%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹9.7 L+₹1.1 L (13.3%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹9.8 L+₹1.2 L (14.5%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹10.3 L+₹1.8 L (21.2%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
7 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR,REPLACEMENT,MAINTENANCE OF MAIN DISTRIBUTION BOX AND OTHER MISC WORK IN MARRIED, OTM ACCOMODATION AT WAR MEMORIAL COLONY, TRANSIT HOSTEL, MES KEY PERSONAL AND 60 SCIENTIST HOSTEL UNDER GE(I) R and D KANPUR.
2022_MES_556763_1
8305/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE I R and D Kanpur
As Per NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹24,000
Yes
11 Jan 2023
10 Oct 2022
9 Nov 2022
10 Oct 2022
7 Nov 2022
24 Oct 2022
10 Oct 2022 - 22 Oct 2022
Amount
Attending the complaints lodged by the occupants/users of electrification nature & rectification of the fault as per the complaint lodged by the user onward OH line LT/HT lines in any time (day/Night) in respect of main fixture /breakdown for light/fan/bell/light or power socket and LT/HT OH line etc complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, sunken boxes, junction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/ Exhaust fans and other type of complaints to connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws , nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixtures to their position as dismantled and respect of item if required to be paid under respective item as required complete all as directed at site to th entire satisfaction of Engr-in-Charge/users.
Note: (a) No light ,breakdown, repair/ replacement of switches, fan, regulator , replacing burnt/ damaged wiring , replacement of burnt MCBs and main switch , voltage fluctuation, current leakage, replacement of HT DOs/fuse, repair of street lights, repair of OH line, OH conductor and replacement of tube lights etc will be attended with in 8 Hrs as urgent nature. (b) Any LT breakdown complaints will be attended by skilled electricians/ Helpers as required at site without any delay & any time (day/Night). (c ) The complaints will be attended by electricians & respective helpers in each day & night without any delay. (d) The complaint will be taken from complaint cell of war memorial colony. The rates are included for complaints for 60 scientist hostel, MES Key personnel qtrs, War memorial colony, Transit hostel. (e) All necessary tools & plants i.e. multimeter, tong tester, spanner set, wrench, screw driver set, combination plier, testing lamp set, drilling machine, bamboo ladder, blower/ vaccum cleaner, crimping tool, cutting and chasing tool, insulation megger , etc will have to kept by each tradesman engaged by contractor at his own cost. (f) Any accident/ mishappening occurred during the execution of work shall be responsibility of Contractor. (g) One MOBILE PHONE should also be provided by contractor to the each trademan engaged by him with incoming & out going facilities for normal and after working hours also so as to contact him in case of emergency during the entire period covered under the contract to keep liaison / communication with MES staff . (h) complaint register and complaint slip shall be providing by the contractor duly printed and the cost is deemed to be included in unit rate (j ) Cost of material and labour for replacement of new items shall be measured and paid separately under relevant items of Sch A. Against supply only here-in-after .
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified.
Point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25mm dia with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified. Make of Cable : Plaza, L&T, Havells, Polycab, Grandlay and Make of Conduit : Havells/Kamplast/Polycab/plaza.
All as per srl item No-3 here in above but upto ceiling height and on surface at ceiling.
All as per srl item No-3 here in above but in existing conduit.
All as per srl item No-3 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit.
All as per srl item No-3 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in existing conduit.
All as per srl item No-3 here in above but for one 3 pin 5A socket outlet independent controlled by one switch.
All as per srl item No-3 here in above but for one 3 pin 5A socket outlet independent controlled by one switch in existing conduit.
All as per srl item No-3 here in above but for one 5A socket outlet on the same board controlled by one switch.
All as per srl item No-3 here in above but for one 5A socket outlet on the same board controlled by one switch in existing conduit.
All as per srl item No-3 here in above but for one light point controlled by 2 nos two way switches.
All as per srl item No-3 here in above but for one light point controlled by 2 nos two way switches in existing conduit.
All as per srl item No-3 here in above but for one light/fan/bell point including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
All as per srl item No-3 here in above but for one socket outlet 5 amps on indipendent board including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
All as per srl item No-3 here in above but for one socket outlet 5 amps on same board including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
All as per srl item No-3 here in above but for one light point controlled by two, two way switches including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
All as per srl item No-3 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories as directed.
M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 2.5 Sqmm as earth lead in & including concealed PVC conduit medium grade 25mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. Make of Cable : L&T, Havells, Polycab and Make of Conduit : Havells/Kamplast/Polycab
All as per srl item No-19 here in above but in existing concealed conduit .
All as per srl item No-19 here in above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit .
All as per srl item No-19 here in above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm in existing concealed conduit with earth wire 4 sqmm.
M&L for switch piano flush button single pole one way 5/6 amps 240 volts. Make :Cona/SSK/Leader
S&F switch piano flush button single pole one way 15/16 amps 230 Volts. Make :Cona/SSK/Leader
M&L for switch piano flush button single pole two way 5 amps 240 volts Make :Cona/SSK/Leader
M&L for bell push flush button single pole one way 5 amps 240 volts. Make :Cona/SSK/Leader
M&L for socket 5 amps 5 pin flush type, 230 volts. Make :Cona/SSK/Leader
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts. Make :Cona/SSK/Leader
M&L for ceiling rose surface bakelite 3 terminals. Make :Cona/SSK/Leader
M&L for bell electric heahy duty Ding Dong type 230 volts single pole complete and all as specified. Make :Cona/SSK/Leader
S & F Lamp holder insulated body with back plate for dome batten fittings.Make :Cona/SSK/Leader
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed by engineer-in-charge. Make :Cona/SSK/Leader
M&L for switch modular type single pole one way 1 module 6 amps 240 volts. Make :Legrand/ Havells/Cona.
S&F switch modular type one way 1 module 16 amps 230 Volts. Make :Legrand/ Havells/Cona
M&L for switch modular type two way 1 module 6 amps 240 volts Make :Legrand/ Havells/Cona
M&L for bell push modular type 1 module one way 6 amps 240 volts . Make :Legrand/ Havells/Cona
M&L for socket 6 amps modular type 2/3 pin combined 2 module , 230 volts. Make :Legrand/ Havells/Cona
M&L for socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts. Make :Legrand/ Havells/Cona
S&F electronic regulator modular type one way 1 module 230 Volts. Make :Legrand/ Havells/Cona
Supply & fix in concealed or fixed on wall of rigid non-metallic PVC conduit of size 25 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc make of conduit :- Kamplast/Plaza/Poly gold/AKG
S&F in replacement of wall mounted LED light fittings 20/22 watt, 6500K, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete connecting electrically all as directed. Make : C&S/Havells/Phillips/Bajaj/Wipro
S&F in replacement of LED bulk head fitting with opal diffuser min 10 Watt, 6500 K, IP-65, with efficient heat dissipation and integrated electronic driver complete connecting electrically all as directed. Make : C&S/Havells/Phillips/Bajaj/Wipro
S&F in replacement of LED mirror light fitting min 10 Watt Watt,1' long, with efficient heat dissipation and integrated electronic driver complete connecting electrically all as directed. Make : C&S/Havells/Phillips/Bajaj/Wipro
Supply only LED Bulb 9 W all as specified and directed.
S&F in replacement of LED light fitting recess mounted min 32/36 Watt, 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection properly all as directed. Make : C&S/Havells/Phillips/Bajaj/Wipro
S&F in replacement of LED light fitting recess mounted min 32/36 Watt, 1' x 4' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection properly all as directed. Make : C&S/Havells/Phillips/Bajaj/Wipro
Supply and fix in replacement of High power LED wall security light 25 Watt IP 66 Energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver incl suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated complete all as spfd. Make : C&S/Havells/Phillips/Bajaj/Wipro
S & F in replacement of LED post top lantern 35/40 Watt warm white/white made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP-65 protection including fixing of GI pipe of suitable dia dia, 300 mm long light grade, partly embedded on column of gate with fixing arrangement complete and making electrical connection complete all as spfd. Make : C&S/Havells/Phillips/Bajaj/Wipro
Supply and fix in replacement energy saving surface mounting premium LED luminaries 14 watt suitable for corridor made out of CRCA metal housing and PPMA diffuser for elegant look, complete etc all as specified and directed. Make Make : C&S/Havells/Phillips/Bajaj/Wipro. Note : Contractor will submit guarantee/warranty certificate from manufacturer.
Supply & Fixing in replacement of Horizontal DB by TPN Distribution Box vertical, double door of protection grade IP 43 provn for 4 Pole MCCB frame F4+12 modules upto 250 Amps , upto 50 KA breaking capacity as incomer in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed.make approved by GE.
Supply and fixing of MCCB 100 Amps 25 KA with fixed thermal magnetic release frame F2 optim 1.0 , 4pole all as specified and directed.make approved by GE.
M&L MCB Three pole & neutral 415 volts 63 amps,with rupturing capacity 10 KA using thimbles of required size. make approved by GE.
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .Make: Legrand/Havells/ABB/L&T/IndoAsian
All as per item No 53 but for 8 way.
All as per item No 53 but for 12 way.
M&L for MCB single pole 240 volts 5 to 30 amps, with rupturing capacity 10 KA using thimbles of required size. Make: Legrand/Havells/ABB/L&T/IndoAsian
M&L MCB single pole & neutral 240 volts 30 to 63 amps,with rupturing capacity 10 KA using thimbles of required size. Make: Legrand/Havells/ABB/L&T/IndoAsian
M&L MCB triple pole & neutral 240 volts 30 to 63 amps,with rupturing capacity 10 KA using thimbles of required size. Make: Legrand/Havells/ABB/L&T/IndoAsian
M&L for single pole and neutral enclosure with a top pin, earth plug and socket copmlete with one SP MCB 25 Amps, 240 Volts. Make: Legrand/Havells/ABB/L&T/IndoAsian
S&F in replacement of service wire 6 Sqmm, 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in selvice connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular
All as per item No- 60 but of size 10 Sqmm.
M&L in replacement of earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion.
M/s A S Electrical
santosh electronics
S B ENTERPRISES
SAKSHAM SUPPLIERS BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .