| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC | ₹2.4 Cr Quoted ₹2.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.6 Cr+₹13.8 L (5.59%)Rejected-Finance NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | ₹2.6 Cr+₹13.8 L (5.59%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹2.6 Cr+₹13.8 L (5.60%)Rejected-Finance 402 C WING BUILDING NO 86 NAVRANG CO OP HSG SOCIETY LTD TILAKNAGAR CHEMBUR MUMBAI 89 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400089 | ₹2.6 Cr+₹13.8 L (5.60%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹2.7 Cr+₹26.2 L (10.6%)Rejected-Finance PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | ₹2.7 Cr+₹26.2 L (10.6%) | L4 | Rejected-Finance Not lowest |
| 5 | L5₹2.7 Cr+₹26.4 L (10.7%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹2.7 Cr+₹26.4 L (10.7%) | L5 | Rejected-Finance Not lowest |
Tender Value
₹2.9 Cr
EMD Value
₹3.6 L
Closing Date
3 May 2024, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
ADDITION ALTERATION TO BLDG NO 124A OF DMRL UNDER GARRISON ENGINEER I RND KANCHANBAGH HYDERABAD
2024_MES_647894_1
84010
Open Tender
Civil Works
Item Rate
365 days
KANCHANBAGH HYDERABAD
Class B
Category a (i)
8 documents required · 8 mandatory
₹2,000
GARRISON ENGINEER RND KANCHANBAGH HYDERABAD
₹3.6 L
Yes
4 Jun 2024
26 Mar 2024
10 May 2024
26 Mar 2024
3 May 2024
26 Apr 2024
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises to a distance outside MD land, complete all as specified and directed.
S&F Non - skid edge cut Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in cement mortar 1:6 complete all as specified and directed.
All as per item No 2 above but on vertical surfaces such as skirting (Skirting is to be flush with wall) and 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as backing coat for tiles complete all as specified and directed.
S&F glazed ceramic coloured tiles including borders in vertical surfaces 450x300x7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles including 10mm thick rendering in CM 1:4 as backing layer complete all as specified and directed.
S&F light shade vitrified tiles 10mm thick double charged (Square/rectangular) polished area of each tiles not exceeding 0.36 sqm in floors etc laid in patterns of two colours, set and jointed with 15mm thick screed bedding in CM 1:6 and pointed in white cement or coloured cement to match with colour of tiles complete all as specified and directed.
All as per item No 5 above but on vertical surfaces such as skirting (Skirting is to be flush with wall) and 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as backing coat for tiles complete all as specified and directed.
M&L for Acid resistant tiles 15mm thick vitreous ceramic , unglazed tiles etc and jointed with 15mm thick screed bedding in CM 1:6 and pointed in white cement or coloured cement to match with colour of tiles complete all as specified and directed.
M & L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like including pointing white cement (1:2) using marble dust with admixture of pigment to match the shade of granite including cutting grooves and nosing including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for 18 to 20mm thick polished granite work ( of any type) machine cut, in risers, skirting /dado fixed over 10mm thick rendering in CM 1:4 as backing coat and jointecd with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone, including grinding etc complete all as specified and directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as specified and directed.
S&F anodised aluminium frame powder coated (minimum thickness of powder coating 50 micron) for doors, windows, ventilators and partition with one or more rebated including joining cleats for fixing etc complete all as specified and directed.
S&F Powder coated (thickness of powder coating not less than 50 micron) aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 150mm - 02 No in each door, steel hinge 100mm - 03 Nos in each door,anodised aluminium snap beading, SS screws, including necessary filling up the gaps at junctions, i.e at top, bottom and sides with required EPDM rubber/ neoprene gasket etc complete all as specified and directed.
S&F anodised Aluminium sliding window powder coated of standard sections 2 mm thick of approved colour and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gaskets, shutter roller, locking device for lock the sliding shutter complete all as specified and directed
S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, properly rolled on glass panes without any wrinkle complete all as specified and directed.
S & F Aluminium powder coated deco grill of make "Deco grill" ,DG - 102 model , 7.5mm thick fitted in to suitable Aluminium channel , 'F' section and fixed to windows/ ventilators complete all as approved and directed.
S&F 5.5mm thick sheet glass colour / tinted for aluminium window/ ventilator , doors and partition with rubber packing, 'u' clip, 'F' section in square n. exc 0.50 Sqm in each pane complete all as specified and directed.
S&F 12mm thick both side prelaminated particle board interior grade fixed to aluminium door, partiion complete all as specified and directed.
S&F in repairs mortice lock, 4 levers vertical type size brass size 75mm complete all as specified and directed.
Dismantling unserviceable false ceiling of any description, thickness in any position including channels, sections angles etc, complete all as specified and directed.
S&F GI frame work for seamless ceiling comprising of GI perimeter channels 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspeded from soffits at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc. 1.20 m length) of 0.55mm thickness having kurled web of 50mm and hanger 6mm dia GI ( upto 1200mm length) adjustable level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm including 8mm thick ceiling board of siliceous and caalcareous materials reinforced with cellulose fibre for fixing in 600 x 600mm grid complete at all height as per specification, drawing.
Taking down cement plaster of any description on stone or brick walls etc including taking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces including manholes and finished the surface fair and even without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete all as specified and directed.
M & L rendering 5 mm thick in CM 1:3 on fair faces of brick work or concrete on ceiling , finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of OBD over a coat alkali resistance primer over a coat of 1.5 mm wall care putty to achieve smooth & levelled surface complete all as specified and directed.
M&L for preparation of new surfaces and applying two coats of acrylic smooth exterior paint (Apex Ultima) of required shade applied @ 1.67 ltr / 10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 Sqm ) over a coat of 1.50 mm thick wall care putty to make surface smooth complete all as specified and directed. Note : Work to be carried upto building height 15 Mtr
M&L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed.
Taking down existing roof treatment of any description, any position with bituminous felt including plaster/loose concrete and removing rubbish to a distance exceeding 500m but not exceeding 1000m and roughening the surfaces of old concrete by picking, scraping, cleaning and washing down with water to remove all dust etc complete all as specified and directed.
M&L for Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) as in padding concrete, coving of vertical junctions, coping of vertical junctions, and platform for OH water tanks, etc on roof top,including necessary formwork, complete all as specified and directed.
M&L for brushing neat cement slurry with 3 Kg of cement per Sqm over the RCC slab and sides complete all as specified and directed.
M&L for rendering 10mm in CM 1:3 over concrete surfaces on RCC roof slab and parapets mixed with WPC @ 3% by weight of cement shall be carried out complete all as specified and directed. Note : WPC will be measured under separate item of this schedule.
Supply only integral water proofing compound complete all as specified and directed.
M & L for providing and carry out water proofing treatment to sound, moisture free concrete surface system includes proper surface preparation to remove loose dust, dirt, loose mortar ,curing compound etc carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Cebex 100 plasticised expanded grout admixture supplies in 225 gm pouch,treatment of construction joints using polymer modified mortar prepared by using Nitobond SBR latects, application of polymer modified batta at floor, wall junction, filling of annular space around rain water outlet using conbextra GP2 non shrink cementitious grouts. Undulated surface and pot hole shall be treated with epoxy mortar or putty to obtain sound/ levelled surface. Application of primer Nito proof WB primer on sound mortar slab surface. Followed by application of coat of Nito proof 600 PF liquid applied single component pitch free polyurithane coating supplied in 25 kg drum coverage @ 2.30 Kg/ m2 to achieve 1.5mm thickness in two coats complete incluidng all tools and tackles as per manufacturers specifcation. Coating shall be having crack bridging of 2mm, elongation ( ASTMD 124 ) greater than 600 percentage, tensile strength ( ASTM D412) , 2.5 N/MM2 , recovery from elongation ( ASTM D412) , 95 percentage, 85 percentage of solid contents, tear resistance ( ASTM D624) , 15 KN/M, shore A hardness ( ASTM D2240) , 60, water vapour transimission not more than 1 gm / M2 ,water permeability ( DIN -1048) - NIL, services tempreature - 40'c to 70 dgree 'c , flash point greater than 70'C HSE guidelines :- It is recommanded to provide adequate general and local exhaust ventilations, providing protection to Eye, face, Hand and other skin by wearing appropriate glouse, google, face cilid, respiratory protectionetc. directed in SDS of the product complete all as specified and directed.
Taking down chowkhats or frames exc 1.5 sqm but not exc 4.00 sqm (without taking off shutters from the frame) with shutters complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frames shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail on either side and as insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F 300mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section complete all as specified and directed.
S&F 100mm butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin complete all as specified and directed.
S&F aluminium anodised barrel tower bolts 150mm long complete all as specified and directed.
S&F 150mm size extruded aluminium alloy handles fabricated type anodized complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type 60cm long between flanges with brass screws complete all as specified and directed.
S&F in repairs venetian blinds (vertical type) of 100mm wide straps with all fittings (to be matched with existing pattern) complete all as specified and as directed.
S&F in repairs vitreous china white wash down water closet pan (pedestal pattern), including white seat cover, with inlet, ball valve, float and handle including brackets, including flush pipe of polyethylene of low or high density or PVC 32mm dia, for low level cistern complete all as specified and directed.
S & F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rests, suitable CI trap including connection to trap, flushing pipe, antisyphonage pipe etc. including trap set in and including concrete and making good to floor complete all as specified and directed.
S & F in repairs 10 litres capacity, PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete all as specified and directed.
S&F in repairs vitreous china wash hand basin white of size 550 x 400mm flat back excluding taps, waste china and plug but including brackets, CP waste fittings 32mm dia including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S & F in repairs Vitreous China Half stall urinal White complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, including cost of fixing automatic flushing cistern with brackets complete all as specified and directed.
S&F in repairs 15mm bore pillar taps, cast copper alloy, chromium plated, fancy type with capstan head screwed down high pressure with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed.
S&F in repairs chromium plated waste coupling of size 32/38mm for kitchen sink/ WHB of any size complete all as specified and as directed.
S&F in repairs PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair PVC connection 15mm dia 600mm long with 2 Nos brass check nuts with washer complete all as specified and directed.
S & F in repairs 75mm bore CI sand cast soil, waste and vent pipes in any length with or without ears, with cement joint fixed to wall complete all as specified and directed.
All as per item 53 above but 100mm bore pipes complete all as specified and directed.
S & F in repairs 75mm bore CI bends (any radius), diminishing pieces or tapers complete all as specified and directed.
S & F in repairs 100mm bore CI bends (any radius), diminishing pieces or tapers complete all as specified and directed.
S & F in repairs 75mm bore CI bends (any radius), diminishing pieces or tapers with oval access door complete all as specified and directed.
S & F 100mm bore CI bends (any radius), diminishing pieces or tapers with oval access door complete all as specified and directed.
S & F in repairs 75mm bore branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel brances with oval access doors complete all as specified and directed.
All as per item 59 above but 100mm bore complete all as specified and directed.
S&F 15mm dia medium grade GI tubing with all fittings and fixtures complete fixed to walls, ceilings etc., including taking down existing old GI tubing complete all as specified and directed.
M&L cast iron nahani trap 75 mm with grating including jointing to waste pipe fixed in cement concrete type B-1 1:2:4 complete all as specified and directed.
S&F in repairs stop valve of 15mm dia fancy type cromium plated cast copper alloy, screwed down high pressure with screwed or butterfly handle screwed both ends for iron pipes complete all as specified and directed.
S&F in repairs 15mm bore bib taps fancy type cromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repairs 20mm bore dia gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Demolition of brick work masonry, built in cement mortar including all quoins, pillars etc.,complete all as specified and directed.
M & L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 mtr mean radius using old size brick built in CM 1:6 including raising height of man holes from ground level complete all as specified and directed.
S & F Aluminium (Die cast) body Door closer hydraulically regulated, design No3, universal type suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and directed.
S&F 1000 ltr Rotational moulded polyethelene water storage tanks triple layered with hoisted and fixed in position all as specified including PVC float valve 20mm dia complete including dismantling of old tanks of any capacity all as specified and directed.
M&L for 75 mm thick Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base/floors complete all as specified and directed.
S&F 20-25 mm thick chequered cement tiles rubber moulded of size 300x300 mm with wear resistant coat of approved design laid with cement slurry @3Kg/sqm over 15mm thick screed bed in CM1:6 including dismantling existing tiles complete all as specified and directed.
M & L for complete removal of existing treatement and and applying two coats of weather proof Acrylic Exterior emulsion paint of approved make and shade over a coat of approved primer as recommended by the manufacturer 1.5mm thick wall care putty to make surfaces smooth complete all as specified and directed.
M&L for preparation of old painted surfaces of wall and applying one coat of distemper oil emulsion complete all as specified and directed.
M&L for complete removal of existing treatment , plastered surfaces of walls and applying two coats of OBD over a coat of alkali resistant primer over a 1mm thick wall putty to achieve smooth & levelled surface complete all as specified and directed.
M & L for preparation of old plastered or unplastered decorated surfaces and applying two coat of white wash on ceiling complete all as specified and directed.
M & L for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint of any tint complete all as specified and directed.
M & L for preparation of old painted steel surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint of any tint complete all as specified and directed.
M&L for preparation of old treated wooden surfaces of any description over 10 cm in width or girth applying one coat of varnishing includng wood filler complete all as specified and directed.
Taking down chowkhats or frames not exc 1.5 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed.
S&F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc as specified , erected in position and securing runners with holdfasts and brackets complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or grith,and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
S&F in repairs white vitreous china laboratory sink size 600 x 450 x 200mm with plugs, washers and wastes including bedding in cement mortar on to dwarf walls or including fixing cantilever brackets and connection union to waste pipe upto 0.5 Sqm each complete all as specified and directed.
Taking up or down steel tubing and connections, Supply and fixing 20mm dia GI steel tubes, medium grade with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth, for foundations etc or for shaft , wells, cesspits etc not exc 10 Sqm on plan and n exc 1.5m in depth getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed.
Removing Excavated soils not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for plain Cement Concrete type D-2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M & L for reinforced Cement Concrete Design Mix M-25 using 20mm graded aggregate as in foundations including rafts, footings, plinth beams , bases for column etc complete all as specified and directed.
M & L for reinforced Cement Concrete Design Mix M- 25 (20mm graded aggregate ) as in columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for reinforced cement concrete Design Mix M-25 (20 mm graded aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for reinforced cement concrete Design Mix M-25 (20mm graded aggregate) as in slab supported on walls, beams and columns in floors, roof, landing, balconies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for reinforced cement concrete Design Mix M-25 (20mm graded aggregate) as in stairways ( except spiraly staircase) including steps ( square or spandril), string pieces, etc complete all as specified and directed.
M&L for reinforced cement concrete Design Mix M-25 (20mm graded aggregate) as in fascia, louvres, parapets and railings etc , newels, balustrade and the like complete all as specified and directed.
M & L for rough finished flat steel form work to sides of concrete foundations, rafts, plinth beams and similar work, vertical or batter complete all as specified and directed.
M & L for rough finished Square, rectangular or polygonal steel form work to sides of pillars, posts, struts, columns and stanchions complete all as specified and directed.
M & L for rough finished flat steel formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
M & L for rough finished flat steel formwork to soffits of suspended slabs, such as roof slabs, floor slabs, landings and similar work not exc 200mm thick (Horizontal or sloping) complete all as specified and directed.
M & L for rough finished flat steel formwork to staircase with sloping or stepped soffits including risers and stringers ( excluding landing) complete all as specified and directed.
M & L for rough finished flat steel formwork to parapets and staircase railings and similar work includng attached pillasters, etc vertical or to batter complete all as specified and directed.
M & L for rough finished flat steel formwork to edges of concrete flats, treads, breaks in floors, and roofs not exc 20 cm wide and sides of RCC bands in walls horizontal or sloping and similar work complete all as specified and directed.
M & L for mild steel TMT bars 500D 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
All as per item No 101 above, but 6mm to 8mm dia complete all as specified and directed.
M & L for mild steel TMT bars 500D 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
Taking down old Unserviceable Copper/Aluminium point wiring (Light/fan/socket or power socket, bell etc) complete including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing/shifting old materials to stores for taking credit (credit shall be made as per conditions) and making good the disturbed surfaces of walls, floors, roofs etc complete all as specified and directed
Taking down old unserviceable DBs including MCCBs/MCBs complete issued under schedule of credit and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
Taking down old unserviceable sub main wiring of any type and size and making good the distrubed surfaces to match with existing surfaces complete all as specified and directed.
M & L for Point wiring with 1.5 Sqmm, single core, PVC insulated, unsheathed, multistranded copper conductor cable, FRLS type, 1100 volts grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit 25mm dia medium grade and conduit accessories concealed in walls, floors except in roofs duly chases cutting groove by chiselling/mechanically as required and making good the disturbed surfaces to match with existing surface and including GI modular boxes flushed in walls covered with modular white cover plates and frames of required size fixed with cadmium plated iron screws for mounting of modular switches, sockets, regulators etc and including 1.5 sqmm FRLS type PVC insulated, unsheathed, multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for the following :
One light point controlled by one, one-way switch.
One ceiling fan/ exhaust fan point controlled by one, one-way switch.
One 5 pin socket outlet point controlled by one 5 Amps switch on independent board
One call bell point controlled by one bell push.
One 5pin socket outlet point controlled by one 5 Amps switch on the same board
All as per item No 107 above, but wiring with 2.5 sqmm and earh continuity conductor with 2.5 sqmm for 6 pin15 amps socket out let point on independent board complete all as specified and directed.
S & F modular switch single pole, one way, 6 Amps, 240 volts, one module complete all as specified and directed.
S & F modular switch, single pole, one way,16 Amps, 240 volts, one module complete all as specified and directed.
S & F modular type Bell push flush type 5 Amp complete all as specified and directed.
S & F modular socket out let, 5 Pin 6 Amps, two module, 240 volts complete all as specified and directed.
S & F modular socket outlet 6 pin 6A/16 Amps, 240 volts, two module complete all as specified and directed.
S & F modular fan regulator electronic type, 230 Volts, stepped type 120 Watts, two module complete all as specified and directed.
S & F Call Bell ding dong type, 230 Volts, AC and fixing on suitable base plate complete all as specified and directed.
S & F Ceiling rose surface bakelite 65 x 50 mm, three terminals 230 volts, AC complete all as specified and directed.
S & F lamp holders insulated body card grip pattern suitable for batten/ angular complete including LED lamp 12 Watt complete all as specified and directed.
S & F LED tube light fitting 20 Watt (4 ft length) batten fitting 240 V, comprises of extruded channel in thermally conductive material with milky white diffuser duly pre-wired and fixing arrangement on wall with suitable base plate and making electric connections by providing 3 core copper conductor cable from ceiling rose to light fitting complete all as specified and directed.
S & F recess mounted full panel LED luminaire 36 watt fitting of size 2' x2' with white powder coated housing and frame in CRCA sheet, high efficiency LED grade diffuser, electronic driver duly pre-wired upto terminal block, CRI>80, Colour temperature-6500K including electric connections by providing 3 core copper conductor cable from ceiling rose to light fitting complete all as specified and directed.
S & F LED street light fitting 36 watt made up of die cast housing with toughend glass and high power LEDs complete with IP 65 protection duly pre-wired and fixing arrangement on wall surface at suitable height by providing GI bracket medium grade of suitble size and adequate length with necessary fixing clamps and making electric connections by providing 3 core copper conductor cable from ceiling rose to light fitting complete all as specified and directed.
S & F MCB DB 12 way, SPN, 240 V, 50Hz, AC, double door IP 43 protection with 200 Amps busbar, neutral bar, earth bar complete with powder coated painting and fixing in flush with wall and making good match with existing surface and making electrical connections using suitable sizes of thimble copper lugs etc complete all as specified and as directed .
S & F MCB DB 8 way, SPN, 240 V, 50Hz, AC, double door IP 43 protection with 200 Amps busbar, neutral bar, earth bar complete with powder coated painting and fixing in flush with wall and making good match with existing surface and making electrical connections using suitable sizes of thimble copper lugs etc complete all as specified and directed .
S & F MCB DB 4 way, TPN, 415 V, 50Hz, AC, double door IP 43 protection with 200 Amps busbar, neutral bar, earth bar complete with powder coated painting and fixing in flush with wall and making good match with existing surface and making electrical connections using suitable sizes of thimble copper lugs etc complete all as specified and directed.
S&F sheet metal enclosure MCB, DB, SPN double door type AC 240 volts 4 way with 200 Amps rated bus bar complete all as specified and directed.
S & F sheet metal enclosure with a two pin and earth plug and socket including MCB SP 20A, 10 KA 'C' curve, 240V, 50 Hz, AC
S & F MCB DP 40 Amps working on 240 volts 50 Hz AC supply,10 KA C series complete all as specified and directed.
S & F MCB SP 6 to 32 Amp 10 KA C curve, 240 volts 50 Hz AC complete all as specified and directed.
S & F MCB TPN 63 Amp 10 KA C curve, 240 volts 50 Hz AC complete all as specified and directed.
M & L for submain wiring with 2 run of 6 Sqmm, single core, PVC insulated, unsheathed, multistranded copper conductor cable, FRLS type, 1100 volts grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit 25mm dia medium grade and conduit accessories concealed in walls, floors except in roofs duly chases cutting groove by chiselling/mechanically as required and making good the disturbed surfaces to match with existing surface including 1run of 6 sqmm PVC insulated, single core, unsheathed, multistranded copper conductor cable, FRLS type, 1100 volts grade as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note :- 3 runs of 6 sqmm copper conductor and 1 run of PVC conduit shall be measured as one unit.
M & L for submain wiring with 2 run of 4 Sqmm, single core, PVC insulated, unsheathed, multistranded copper conductor cable, FRLS type, 1100 volts grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit 25mm dia medium grade and conduit accessories concealed in walls, floors except in roofs duly chases cutting groove by chiselling/mechanically as required and making good the disturbed surfaces to match with existing surface including 1run of 4 sqmm PVC insulated, single core, unsheathed, multistranded copper conductor cable, FRLS type, 1100 volts grade as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note :- 3 runs of 4 sqmm copper conductor and 1 run of PVC conduit shall be measured as one unit.
M & L for submain wiring with 2 run of 2.5Sqmm, single core, PVC insulated, unsheathed, multistranded copper conductor cable, FRLS type, 1100 volts grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit 25mm dia medium grade and conduit accessories concealed in walls, floors except in roofs duly chases cutting groove by chiselling/mechanically as required and making good the disturbed surfaces to match with existing surface including 1run of 2.5 sqmm PVC insulated, single core, unsheathed, multistranded copper conductor cable, FRLS type, 1100 volts grade as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note :- 3 runs of 2.5 sqmm copper conductor and 1 run of PVC conduit shall be measured as one unit.
M&L for sub main wiring with 4 run of 16 sq mm of single core copper conductor cable PVC insulated, unsheathed, multistranded FRLS type, 1100V grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit not less than 25 mm dia medium grade with conduit accessories concealed in walls / floors / ceiling etc duly cutting chases/ grooves and making good the disturubed surfaces to match with existing surfaces including 2 run of 16 Sq mm single core copper conductor cable, PVC insulated, unsheathed, multistranded FRLS type, 1100V grade green in colour as earth continuity conductor and connecting to earth dolly complete all as specified and directed Note:- 6 runs of 16 Sq mm and one run of PVC conduit will be measured and paid as one unit
M&L for sub main wiring with 4 run of 10 sq mm of single core copper conductor cable PVC insulated, unsheathed, multistranded FRLS type, 1100V grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit not less than 25 mm dia medium grade with conduit accessories concealed in walls / floors / ceiling etc duly cutting chases/ grooves and making good the disturubed surfaces to match with existing surfaces including 2 run of 10 Sq mm single core copper conductor cable, PVC insulated, unsheathed, multistranded FRLS type, 1100V grade green in colour as earth continuity conductor and connecting to earth dolly complete all as specified and directed Note:- 6 runs of 10 Sq mm and one run of PVC conduit will be measured and paid as one unit
M&L for sub main wiring with 4 run of 6 sq mm of single core copper conductor cable PVC insulated, unsheathed, multistranded FRLS type, 1100V grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit not less than 25 mm dia medium grade with conduit accessories concealed in walls / floors / ceiling etc duly cutting chases/ grooves and making good the disturubed surfaces to match with existing surfaces including 2 run of 6 Sq mm single core copper conductor cable, PVC insulated, unsheathed, multistranded FRLS type, 1100V grade green in colour as earth continuity conductor and connecting to earth dolly complete all as specified and directed Note:- 6 runs of 6 Sq mm and one run of PVC conduit will be measured and paid as one unit
M & L for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6 mm thick buried in ground vertically to a depth not less than 2.25 metres below normal ground level with top edge of earth plate not less than 1.5 metres below normal ground level connected to and including GI strip 25 x 4 mm connected galvanised iron earth plate by means of GI bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of MES SSR Part-I connected to earth test point all as specified or indicated including testing on completion to achieve test result upto 2 ohms and including 15 mm bore light grade GI protection pipe 7.5 metres long including PCC 1:2:4 pit with pre-cast RCC 1:2:4 type B1 cover 40 mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hook made out of 6mm dia MS bars watering arrangement pipe of 20mm dia medium grade with wire mesh funnel and providing common salt and charcoal filling all around earth plate upto 15cm thick and necessary excavation and earth work in any type of soil and returning filling of soil, removing surplus soil etc complete all as specified and directed
M & L for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6 mm thick buried in ground vertically to a depth not less than 2.25 metres below normal ground level with top edge of earth plate not less than 1.5 metres below normal ground level including earth lead wire GI 4mm dia connected to and including galvanised iron earth plate by means of GI bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of MES SSR Part-I connected to earth test point all as specified or indicated including testing on completion to achieve test result upto 2 ohms and including 15 mm bore light grade GI protection pipe upto 7.5 metres long including PCC 1:2:4 pit with pre-cast RCC 1:2:4 type B1 cover 40 mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hook made out of 6mm dia MS bars watering arrangement pipe of 20mm dia medium grade with wire mesh funnel andproviding common salt and charcoal filling all around earth plate upto 15cm thick and necessary excavation and earth work in any type of soil and returning filling of soil, removing surplus soil etc complete all as specified and directed. Note for item No 135 & 136 : - (i) Earth continuity conductor beyond 7.5 mtrs shall be measured and paid separately under relevant item of this BOQ. (ii) If test results does not achieve earth pit shall be re-done at own cost by the contractor.
M & L for earth continuity conductor 4 mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing or main earth wire complete all as specified and directed.
All as per item No 137 above but with 25 x 4 mm GI strip complete all as specified and directed.
S&F sheet metal MCCB enclosure TPN 415 Volts factory made epoxy powder coated painting suitable for and including MCCB 100 Amps, 4 Pole, 16 KA, 415 Volts and and making electric connections complete all as specified and directed.
S&F sheet metal MCCB enclosure TPN 415 Volts factory made epoxy powder coated painting suitable for and including MCCB 40 Amps, 4 Pole, 16 KA, 415 Volts and and making electric connections complete all as specified and directed.
Supply, laying, testing and commissioning LT cable of size 400 sq mm 3.5 core XLPE insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trenches, through pipes, walls, ducts and including making electric connection by providing lugs and glands etc complete all as specified and directed.
All as per item No 141 above but of size 120 sqmm 3.5 core complete all as specified and directed.
All as per item No 141 above but of size 70 sqmm 3.5 core complete all as specified and directed.
All as per item No 141 above but of size 50 sqmm 3.5 core complete all as specified and directed.
All as per item No 141 above but of size 35 sqmm 3.5 core complete all as specified and directed.
Supply, install testing and commissioning of CPRI approved Indoor type, LT panel board suitable for 415Volts 3 phase 4 wire, 50 HZ power distribution panel of suitable size, pre -wired with adequate size of single core PVC inslulated FRLS stranded copper conductor cable, control fuses, earthings terminals , lifting hooks , danger notice plate, free standing , front and back openable construction, floor mounting, dust and vermin proof of IP-52, provn for ventilation, compartimantalised design, hinged type double door with mehanical locking arrangement for each feeder, factory fabricated out of 2.0 mm thick CRCA sheet, 7 tank process powder coated painting fixed on and inlcuding MS angle iron frame of suitable size and bottom legs made of MS angle iron 50 x 50 x 6mm including necessary earth work, civil work with PCC 1:3:6 type C2 foundation and comprising of the following switch gear and accessories complete all as specified and directed :- (a) Bus bar chamber of 3 phase and neutral 4 strip 415 volts with 2000 Amps copper strip - 1 set (b) ACB 1250 Amps 4 pole 50 KA , 415V, microprcessor release, manual drawout type - 1 No (In coming) (c) MCCB 630 Amps, 4 pole 36 KA, 415 Volts (Adjustable TM)- 1 No (Out going) (d) MCCB 500 Amps, 4 pole 36 KA, 415 Volts (Adjustable TM) - 1 No (Out going) (e) MCCB 400 Amps, 4 pole 36 KA, 415 Volts (Adjustable TM) - 1 No (Out going) (f) Digital voltmemter 0-500 V- 01 No (g) Digital Ammeter 0-1250 Amps with CTs-- 01 No (h) LED Indicator lamp Red, Yellow, Blue - 01 Set (j) Complete internal wiring with suitable copper condutor wires - 1 Lot (k) Provision of extra space for 1more out going feeders suitable for 400 Amps MCCB Note : (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item
Supply, install testing and commissioning of CPRI approved Indoor type, LT panel board suitable for 415Volts 3 phase 4 wire, 50 HZ power distribution panel of suitable size, pre -wired with adequate size of single core PVC inslulated FRLS stranded copper conductor cable, control fuses, earthings terminals , lifting hooks , danger notice plate, free standing , front and back openable construction, floor mounting, dust and vermin proof of IP-52, provn for ventilation, compartimantalised design, hinged type double door with mehanical locking arrangement for each feeder, factory fabricated out of 2.0 mm thick CRCA sheet, 7 tank process powder coated painting fixed on and inlcuding MS angle iron frame of suitable size and bottom legs made of MS angle iron 50 x 50 x 6mm including necessary earth work, civil work with PCC 1:3:6 type C2 foundation and comprising of the following switch gear and accessories complete all as specified and directed :- (a) Bus bar chamber of 3 phase and neutral 4 strip 415 volts with 1000 Amps copper strip - 1 set (b) MCCB 630 Amps, 4 pole 36 KA, 415 Volts (Adjustable TM)- 1 No (incoming) (c) MCCB 100 Amps, 4 pole 16 KA, 415 Volts (Fixed type) - 01 No (Out going) (d) MCCB 63 Amps, 4 pole 16 KA, 415 Volts (Fixed type) - 07 Nos (Out going) (e) MCCB 40 Amps, 4 pole 16 KA, 415 Volts (Fixed type) - 05 Nos (Out going) (f) MCCB 32 Amps, 4 pole 16 KA, 415 Volts (Fixed type) - 01 No (Out going) (g) Digital volt memter 0-500 V- 01 No (g) Digital Ammeter 0-630 Amps with CTs-- 01 No (h) LED Indicator lamp Red, Yellow, Blue - 01 Set (j) Complete internal wiring with suitable copper condutor wires - 1 Lot Note : (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item
Supply, install testing and commissioning of CPRI approved Indoor type, LT panel board suitable for 415Volts 3 phase 4 wire, 50 HZ power distribution panel of suitable size, pre -wired with adequate size of single core PVC inslulated FRLS stranded copper conductor cable, control fuses, earthings terminals , lifting hooks , danger notice plate, free standing , front and back openable construction, floor mounting, dust and vermin proof of IP-52, provn for ventilation, compartimantalised design, hinged type double door with mehanical locking arrangement for each feeder, factory fabricated out of 2.0 mm thick CRCA sheet, 7 tank process powder coated painting fixed on and inlcuding MS angle iron frame of suitable size and bottom legs made of MS angle iron 50 x 50 x 6mm including necessary earth work, civil work with PCC 1:3:6 type C2 foundation and comprising of the following switch gear and accessories complete all as specified and directed :- (a) Bus bar chamber of 3 phase and neutral 4 strip 415 volts with 800 Amps copper strip - 1 set (b) MCCB 500 Amps, 4 pole 36 KA, 415 Volts (Adjustable TM)- 1 No (incoming) (c) MCCB 100 Amps, 4 pole 16 KA, 415 Volts (Fixed type) - 02 Nos (Out going) (d) MCCB 63 Amps, 4 pole 16 KA, 415 Volts (Fixed type) - 06 Nos (Out going) (e) MCCB 40 Amps, 4 pole 16 KA, 415 Volts (Fixed type) - 03 Nos (Out going) (f) MCCB 32 Amps, 4 pole 16 KA, 415 Volts (Fixed type) - 01 No (Out going) (g) Digital volt memter 0-500 V- 01 No (g) Digital Ammeter 0-500 Amps with CTs-- 01 No (h) LED Indicator lamp Red, Yellow, Blue - 01 Set (j) Complete internal wiring with suitable copper condutor wires - 1 Lot Note : (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item
Supply, install testing and commissioning of CPRI approved Indoor type, LT panel board suitable for 415Volts 3 phase 4 wire, 50 HZ power distribution panel of suitable size, pre -wired with adequate size of single core PVC inslulated FRLS stranded copper conductor cable, control fuses, earthings terminals , lifting hooks , danger notice plate, free standing , front and back openable construction, floor mounting, dust and vermin proof of IP-52, provn for ventilation, compartimantalised design, hinged type double door with mehanical locking arrangement for each feeder, factory fabricated out of 2.0 mm thick CRCA sheet, 7 tank process powder coated painting fixed on and inlcuding MS angle iron frame of suitable size and bottom legs made of MS angle iron 50 x 50 x 6mm including necessary earth work, civil work with PCC 1:3:6 type C2 foundation and comprising of the following switch gear and accessories complete all as specified and directed :- (a) Bus bar chamber of 3 phase and neutral 4 strip 415 volts with 600 Amps copper strip - 1 set (b) MCCB 400 Amps, 4 pole 36 KA, 415 Volts (Adjustable TM)- 1 No (incoming) (c) MCCB 100 Amps, 4 pole 16 KA, 415 Volts (Fixed type) - 01 No (Out going) (d) MCCB 63 Amps, 4 pole 16 KA, 415 Volts (Fixed type) - 05 Nos (Out going) (e) MCCB 40 Amps, 4 pole 16 KA, 415 Volts (Fixed type) - 01 No (Out going) (f) MCCB 32 Amps, 4 pole 16 KA, 415 Volts (Fixed type) - 01 No (Out going) (g) Digital volt memter 0-500 V- 01 No (g) Digital Ammeter 0-400 Amps with CTs-- 01 No (h) LED Indicator lamp Red, Yellow, Blue - 01 Set (j) Complete internal wiring with suitable copper condutor wires - 1 Lot Note : (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item
M & L for river sand filling in trenches as cushioning to cables , complete all as specified and directed. Note: punned thickness only shall be measured for payment.
M & L for Un- reinforced pre cast concrete covers class LV type 250mm x 150mm x 40mm size factory made for cable protection complete all as specified and directed.
S & F GI pipe light grade 100 mm dia for protection of LT cable under road or on wall complete all as specified and directed.
S & F GI pipe light grade 80 mm dia for protection of LT cable under road or on wall complete all as specified and directed.
M&L for cutting of black top cover of existing road / PCC of size 45 x 30 CM for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 uptp 30 cm from top of the road surface complete all as specified and directed.
Supply, Install, testing and commisioning of Split type Air Conditioner of capacity 1.5 TR, five star rated hi wall split units indoor and outdoor with cordless remote control unit and with in-built air ioniser and plasma filter for better indoor Air quality with latest inverter technology, initial filling of Eco friendely refrigerent gas and outdoor unit and indoor unit and necessary fixing arrangement by providing bracket and clamps including adequate size and length of copper tubing and copper conductor cables and other components as required and making connections complete all as specified and directed.
S & F Voltage stabilizer of capacity 4 KVA for automatic operation, phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and making connections complete all as specified and directed.
S & F metal clad plug and socket outlet 2 pole and earth with plug top alongwith MCB SP 20 A "C" curve, 230V, 50 Hz in recess flush in wall with chained metal cover for the socket out let and making connections complete all as specified and directed.
M & L for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6 mm thick buried in ground vertically to a depth not less than 2.25 metres below normal ground level with top edge of earth plate not less than 1.5 metres below normal ground level connected to GI strip 32 x 6 mm connected to and including galvanised iron earth plate by means of GI bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of MES SSR Part-I connected to earth test point all as specified or indicated including testing on completion to achieve test result upto 2 ohms and including 40 mm bore light grade GI protection pipe upto 7.5 metres long including PCC 1:2:4 pit with pre-cast RCC 1:2:4 type B1 cover 40 mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hook made out of 6mm dia MS bars watering arrangement pipe of 20mm dia medium grade with wire mesh funnel and providing common salt and charcoal filling all around earth plate upto 15cm thick and necessary excavation and earth work in any type of soil and returning filling of soil, removing surplus soil etc complete all as specified and directed. Note : - (i) Earth continuity conductor beyond 7.5 mtrs shall be measured and paid separately under relevant item of this BOQ. (ii) If test results does not achieve earth pit shall be re-done at own cost by the contractor.
S&F aluminium strip 25 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed
S&F Air termination, single pointed aluminium rod 12mm dia and 600mm long complete all as specified and directed
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
M/S GDR CONSTRUCTIONS
Sai construction & services
Universal refrigeration and Engineering Company
Shree Construction Co.
SAI KRISHNA ASSOCIATES
power links
Sri Associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .