| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.0 LAdmitted-Finance | -22.13% | ₹4.0 L | L1 | Admitted-Finance |
| 2 | L2₹4.4 LAdmitted-Finance | -13.99% | ₹4.4 L | L2 | Admitted-Finance |
| 3 | L3₹3.9 LAdmitted-Finance | -22.95% | ₹3.9 L | L3 | Admitted-Finance |
| 4 | L4₹4.4 LAdmitted-Finance | -12.35% | ₹4.4 L | L4 | Admitted-Finance |
| 5 | L5₹4.0 LAdmitted-Finance | -21.44% | ₹4.0 L | L5 | Admitted-Finance |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
23 Feb 2026, 3:00 pmClosed
SE CIVIL JVVNL
SE CIVIL JVVNL RAM MANDIR BANI PARK JAIPUR
Const. of broken B/wall damaged due to heavy rain water and other works at 33 KV S/S Udaipuriya Mod under AEN HTM Chomu.
2026_JVVNL_536790_5
E-NIT 30/2025-26
Open Tender
Civil Works
60 days
Chomu.
Please refer Tender documents.
3 documents required · 3 mandatory
₹236
A O(JCC)JVVNL,Jaipur Through NEFT/RTGS/IMPS/UPI
₹14,000
Yes
26 Feb 2026
9 Feb 2026
24 Feb 2026
9 Feb 2026
23 Feb 2026
9 Feb 2026
PART-A (Bldg.)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.(1.31)
6.1.6/B-6 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:l in Cement sand Mortar 1:6 (1- Cement: 6- Sand).
6.2.6 Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand).
Add extra for Random Rubble stone masonry with hard stone in(A) Wall upto 30cm. and less thickness. (6.3.4)
(B)Square or Rectangular pillars (6.3.1)
3.8/B-3 P/F precast cement concrete coping 1:2:4 mix 50 mm thick complete as per specifications 50mm
Pointing on stone masonry in cement sand mortar 1:3 (1 cement : 3 sand) : Raised and cut pointing.(12.31.2)
12.3.2/B-12 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished: (A) 20mm thick
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.(14.55)
8.13.2.1/B-8 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure ‘A’ 30mm thick. Commercial veneer both side.
9.17.1/B-9 Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint add extra for double leaf
11.3.2 /B-11 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. (A) 75mm thick with 20mm thick nominal size aggregate.
10.22/B-10 Providing Gola 75mmX75mm in cement conc. 1:2: 4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) i/c finishing with cement mortar 1:3 (1 cement : 3 fine sand as per standard design.
12.22.1 Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete. (A) New plastered surface (three or more coats)
12.37.1 /B-12 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: (A) New work (two or more coats) over and i/c scrapping and priming coat with cement primer.
12.42/B-12 Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ).
12.46.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: (A) Two or more coats on new work.
Nano technology water proofing, thermal insulation protection coating 12 layer process for increasing life of building and damage control for roof.-- before coating scaling, cleaning, and preparing surface for treatment. Opening all joint and cracks and filling them with nano technology crack filling hydrophobic chemical with 2/3 coats. then after drying doing a PCC coat on cracks. One coat of nano technology hydrophobic/oiliophobic primer. Nano technology water proofing treatment in3 coats non silicon based applied with fiber mesh sheets in medium. Nano technology thermal insulation coating highly elasticity in nature with 3 coats with 1000 micron width.2top coats of anti stain, anti slippery, natural transparent high shine chemical for better life of the treatment. (15.28.1)
13.12 Repair to stone masonary in cement sand mortar 1:6 with old and new stone.
13.13 Repair to brick masonary in cement sand mortar 1:6 with new brick.
13.1 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead : With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
13.23 Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge of welding meachine and TP etc complete
13.29 Repair to damaged RCC slabs, beams and columns etc for strengtheing with cement mortar 1 : 2 in following steps i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried. ii) Applying Epoxy primer on the exposed steel bars. iii) Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush. iv)Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day. v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete. vi) Cure the plastered surface for 15 days All work including scaffolding etc. complete in all respect.
2.7.3 /S-2 P & F Bib cock (IS: 8931 Mark), Superior quality of approved make: (A) C.P. brass bib cock 15mm nominal bore.
2.11.2/S-2 P & F Ball Cock (IS: 1703 Mark) with Rod & P.V.C. Ball complete: Brass wt. not less than 400gm 20mm
2.12.1/S-2 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. inlet connection 15mm Brass(Is: 8931 marked)
2.13.2/S-2 P & F 15mm Dia Connection Pipe of approved quality/make PVC pipe with C.P. brass nuts upto length, 370mm
2.26.3/S-2 P & F PVC Storage Tank ( IS: 12701 marked indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 CM long wash out pipe with plug & socket, including making connection etc., complete of approvrd design: 500 ltr capacity
3.16.2 /S-3 P & F rigid PVC pipe ( IS: 4985 make) class II/(4 Kg./Cm2). Approved quality /make including jointing the pipe with solvent cement rubber ring and lubricant. (A) 75 mm dia
(B) 110mm dia. (3.16.3)
3.17.9,3.17.12 & 3.17.4,3.17.10/S-3 P & F rigid PVC pipe fitting ( IS: 4985 make) of approved quality /make including jointing the pipe with solvent cement rubber ring and lubricant. (A) Bend 87.5 75mm dia
(B) Bend 87.5 110mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) (A) 20mm nominal size (2.37.2)
(B) 25mm nominal outer dia pipes (2.37.3)
2.39.2/S Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge. (External work). (A) 20mm nominal outer dia pipes
(B) 25mm nominal outer dia pipes (2.39.3)
E 1.1.1 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR (A) Short point (up to 3 mtr.)
(B) Medium point (up to 6mtr). (E1.1.2)
(C) Long point (up to 10mtr).(E1.1.3)
E 1.3.1 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR on board.
7.37 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
15.7.3 Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
17.1.1 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1170mm(+/-10%) LED batten with min. lumen output 2200 lm
24.67.2 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC type Fire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 4 Kg
3.1.6 & 3.1.2 Providing & Laying in position cement concrete i/c curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering – All work up to plinth level.: (A) 1:4:8 (1 cement:4 course sand: 8 graded stone aggregate 40 mm nominal size).
6.3(iii-a) / R Interlocking Concrete block Pavement With M- 30 Grade 0.30Mtr x 0.30 Mtr x 0.15 Mtr Edge Blocks ( measurements Shall be made inner to inner side of edge blocks ) Providing & laying of interlocking M 30 grade concrete Block pavements having thickness 80 mm as per drawings and as per IS 15658:2006 and all materials shall conform to MoRTH specification Clause 602 with M-30 Grade 0.30 Mtr x 0.30 Mtr x 0.15 Mtr Edge Blocks Category 'A' dentated units to key into each other on all four faces Zigzag shape as per IRC SP 63-2004
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
PART- B (Item Rate Basis)
E/W in filling of excavated earth except black cotton soil with watering & compaction of spreaded earth in 15-30cm layers levelled & neatly dressed as per requirement of site & direction of E/I, work includes cost of earth with taxes, loading, unloading, transportation, labour, water & T&P etc. complete with all lead & lift.
Supply, Stacking, Spreading & hand ramming of quarry rubish in layers not exceeding 15 cm (loose) i/c all lead & lift, transportation, loading, unloading with watering & hand ramming with labour incl. T & P, machinary, water etc. complete in all respect finishing in lying, level & camber as per direction of engineer in charge.th.
S, S & S of graded crusher brocken hard stone aggregate free from organic matter including stacking & spreading in yard / trenches as per the standard specification of size 40mm to 63mm incl. all lead & lift, transportation, labour, loading, unloading & require for graveling work as per direction if Engineer in charge incl. dressing & levelling.
Stacking of laid crusher broken ballast from yard screening & relaying of the same in the same yard as per specifications in layer not exceeding 15cm as per specifications including dressing etc. complete for all lead and lift complete as per direction of Engineer in CHarges.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.22 MB
Tendernotice_2.pdf
PDF • 2.51 MB
BOQ_956670.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid