Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | ₹9.3 L Quoted ₹9.7 L | L1 | Accepted-AOC Awarded being lowest |
| 2 | L2₹14.9 L+₹5.2 L (53.7%)Rejected-Finance SANAT NAGAR SRINAGAR PIN 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | ₹14.9 L+₹5.2 L (53.7%) | L2 | Rejected-Finance Rejected being L2 bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Firm not admitted due to firm not have appropiate categoruy i.e. c (i), Hence not recommended. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Firm not admitted due to firm not have appropiate categoruy i.e. c (i), Hence not recommended. |
Tender Value
₹16.6 L
EMD Value
₹33,210
Closing Date
22 Apr 2024, 6:00 pmClosed
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS
BALANCE WORK REQUIRED TO MAKE CHS FUNCTIONAL AT CAPTAIN BLOCK UNER THE WORK PROVN OF CENTRAL HEATING SYSTEM IN OFFRS MESS FOR 48 OFFRS AT HAWS GULMARG UNDER GE 969 EWS
2024_MES_648081_1
CWEK-93/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 969 EWS
Class E Category c i
7 documents required · 7 mandatory
₹500
GE 969 EWS
₹33,210
HQ 133 WORKS ENGRS
29 Jun 2024
28 Mar 2024
30 Apr 2024
28 Mar 2024
22 Apr 2024
9 Apr 2024
28 Mar 2024 - 4 Apr 2024
5 Apr 2024
Amount
Installation, testing and commissioning including repair/ replacement of Burner, Fuel Pump, Sequence Control Relay, Fuel Pipes,Fuel Filter & other minor items if reqd of oil fired glycol based hot water generator using kerosene oil complete with combustion chamber and equipment automatic burner assembly tubes primary pump control panel with sequence controller, photo cell for flame failure HT transfer electroces, blower assembly electric panel, As AboveHQ CE 31 Zone letter No 25001/993/112/E2(Plg) dated 05 Oct 2023 pressure gauges therometer mounting frame, suitable for operation on 50Hz, 3 phase 415volts AC supply and all as specified and recommended by manufacturer Hot water inlet temp=75 degree centigrade, Hot water outlet temp= 85 degree centrigrade Capacity 1,90,000Kcal/hr at MSL.Make of Boiler: Aquamatic, Make of Burner: Ecoflam. Note:- (a) items inciuding base frame, foundation, fitting, items as and where reqd at site shall be supplied .installed & testing on completion by the contractor upto proper satisfication of MES testing rep.pre installation servicing if required to be borne by contractor without extra cost.
Installation, testing and commissioning with servicing if reqd of manoblock centrifugal pump having stainless steel impeller driven by suitable capacity electric motor for ethylene glycol of 390 LPM and 25mtr head complete with accessories and insulated with two layers of 13mm thick closed cell elastomeric insulation including cement concrete foundation as recommended by manufacturer, all as specified. Note:- (a) Only Monoblock Centrifugal pump will be supplied by MES, all other items including civil works, fittings, Insulation, minor items as and where reqd at site shall be supplied, installed & testing on completion by the contractor upto proper satisfication of MES testing rep. (b) Rate quoted will include the transportation charges not exec the distance of 100m (approx) pre installation servicing if required to be borne by contractor without extra cost.
Installation of mild steel flue gas chimney made out of 3mm thick mild steel sheet, minimum 1.2mtr above the highest point of the building roof and including connection from boiler to main chimney fabricated from 3mm mild steel sheet. The portion of the chimney, flue gas connection inside the building shall be covered with 50mm thick resin boned fibre glass insulation wool of 24kg/cum density and cladded with 26 gauge aluminium cladding all as specified including priming with Zinc oxide paint and insulation as required complete all as specified and directed by Engr In Charge. Note:- (i) Rate quoted will includes all as per site reqmt, mounting/fixing arrangement. (ii) The Hot water generators shall be connected to a independent chimney.pre installation servicing if required to be borne by contractor without extra cost.
Supply Installation of overhead expansion tank of size 1000mm(L)x1000mm(B)1000mm (H) made out of 3mm thick mild steel sheet and complete covered with 13mm closed cell electrometric insulation complete with removable lid, in out drain over flow system, including mounting arrangement and complete connection, with insulation read and priming with Zing Oxide paint complete all as specified and directed by Engr In Charge. Note:- (a) Only Bare tanks will be issued by MES all other connected items mentioned in the above description will be supplied & installed by contractor upto proper statisfication of MES testing rep. pre installation servicing if required to be borne by contractor without extra cost.
Installation of Glycol fluid tank of 1000ltrs capacity made out of 3mm thick mild steel sheet and complete with removable lid, in, out drains, overflows system, mounting arrangement including priming with zinc oxide paint complete all as specified and directed by Engr In Charge. Note:- (a) Only Bare tanks will be issued by MES all other connected items mentioned in the above description will be supplied & installed by contractor upto proper statisfication of MES testing rep. (b) Rate quoted will include the transportation charges not exec the distance of 100m (approx) and all civil works as per design by OEM.
Installation, testing and connecting with the system and commissioning of horizontal cylindrical oil storage tank made out of mild steel as per IS 2062 and fabricated as per IS 10987-1992 design temperature 30C and design pressure atmosphere + static head of liquid. (i) Storage capacity (Nominal) 5000 Its (Il) Shell thickness 4mm (III) End plate thickness 6mm including priming with zinc oxide paint and hinges as required complete all as specified and directed by Engr In Charge. Note: - (a) Only bare tank will be supplied by MES, all other necessary items including nozzles. manhole, lifting lugs, vent pipe suitable dia inlet, outlet and return pipes with flanges etc will be supplied & installed by contractor upto proper satisfication of MES testing rep. (b) Rate quoted will include the transportation charges not exec the distance of 100m (approx)pre installation servicing if required to be borne by contractor without extra cost.
Supply & Installation, testing and commissioning of Kerosene oil day service tank rectangularmild steel contruction with capacity 990 Itrs complete with inlet, outlet, drain and the tank shall be made out of 3mm mild steel sheet and will be provided with supports made out of minium 50mm NB class B pipe to keep tank base minimum (1000mm) above finished floor level! complete all as specified. Note:- (a) Only Bare tanks will be issued by MES all other connected items mentioned in the above description will be supplied & installed by contractor upto proper statisfication of MES testing rep. (b) Rate quoted will include the transportation charges not exec the distance of 100m (approx) and all civil works as per design by OEM.pre installation servicing if required to be borne by contractor without extra cost.
Installation, servicing, lesting and commissioning of rotary goar transfer pump centrifugal lype for capaity 15LPM, 10meter head, for kerosene oil complete with base frame, foundation boltsr coupling and coupling guard and TEFC /B molor (1 HP) and other accessories required for commissioning, all as specified. Note: - (a) Rate quoted will include the transportation charges not exec the distance of 100m (approx) and all civil works as per design by OEM.(b) Only rotary gear transfer pump will be issued by MES, all other items mentioned in above description will be supplied & installed by coniractor upto proper satisfaction of MES testing rep. pre installation servicing if required to be borne by contractor without extra cost.
Supply & Installation, testing and commissioning of mild steel class C black ERW pipe including all fittings such as bends, reducers, flanges, nuts, bolts ete as required complete in all respects of following sizes:-
40mm bore pipe
20mm bore pipe
Ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed of size 25mm bore
Ball brass valves, high pressure, with polythene float and flynut complete, screwede for iron pipe or brass ferrule and fixed of size 40mm bore
Non return valve, brass, high pressure, complete, screwed for iron pipe or brass ferrule and fixed of capacity 25mm bore
Y-oil strainer of size 25mm bore
Laying, testing and commissioning of mild steel class 'C' black ERW pipe including all new fittings such as bends, reducers, flanges, nuts, bolts etc as required complete in all respects of 25mm bore pipe
Laying, connecting, fixing and testing of mild steel ERW, class C piping complete with fittings, duly insulated with closed cell elastomeric insulation 30 to 40Kg/cum density covered with shrink wrap polythene sheet for the following sizes of Hot Glycol fluid pipes:-Note:- The pipes exposed to atmosphere or buried under ground will be insulated with 18mm thick insulation and along the walls inside the building with 13mm thick insulation)pre installation servicing if required to be borne by contractor without extra cost
125mm bore pipe
100mm bore pipe
80mm bore pipe
Supply, laying, connecting, fixing and testing of mild steel ERW, class C piping complete with fittings, duly insulated with closed cell elastomeric insulation 30 10 40Kg/cum density covered with shrink wrap polythene sheet for the following sizes of Hot Glycol fluid pipes:-Note:- The pipes exposed to atmosphere or buried under ground will be insulated with 18mm thick insulation and along the walls inside the building with 13mm thick insulation)pre installation servicing if required to be borne by contractor without extra cost.
65mm bore pipe
40mm bore pipe
50mm bore pipe
Supply, laying, connecting, fixing and testing of polypropylene random copolymer aluminium foiled pipes or composite pipes complete with all fittings duly insulated with 13mm thick closed cell elastomeric insulation 30 to 40 kg/cum density for the following sizes of hot glycol fluid pipes:-
40 mm bore OD pipe
32 mm bore OD pipe
25mm bore OD pipe
Dual plate Non Return valves 100mm bore
Dual plate Non Return valves 65mm bore
Dual plate Non Return valves 40mm bore
Butter fly valves 100mm dia
Butter fly valves 65 mm dia
Butter fly valves 50mm dia
Butter fly valves 40mm dia
Butter fly valves 32mm dia
Ball vaives 25mm bore
Y strainer 100mm bore
Y strainer 65mm bore
Y strainer 40mm bore
Balacing valves 100mm bore
Balancing valves 65mm bore
Balancing valves 50mm bore
Inlet outlet valves for radiator
Pressure gauges with cock and siphon
Water flow switches
Air purging valves
Supply and first fill for makeup requirement for the first year of operation of glycol concentrate along with the necessary additives and inhibitor in congnition and supplied in barrels. The mixture freezing temperature should be (-30C) all as specified
Errection, testing and commissioning of dust damp and vermin proof free standing CPR approved factory built sheet steel enclosed LT main distribution board suitable for 3 ph 415volts, 50hz fabricated out of 2.0mm thick CRCA sheet duly spray painted complete aluminium bus bar 200amp rating and ribbed with sheet of suitable size complete with the following:-
INCOMING
(a) MCCB TP Pole 415V, 100amps with 25KA-01 nos
(b) Phase indication lights and control fuses - 1 set
OUTGOING
MCB 32 Amp, TPN complete with automatic DOL starter with overload, push button with indication lights, 0-60 Amp range Amp meter with CT (for glycol circulation pumps-03 sets
TPN MCB, 20Amps, complete with DOL starter, overload, push button indicationg lights (for oil transfer pump) -02 Sets
MCB, DP, 0-20 Amps, (For Glycol transfer pump) -02 Nos
MCB, DP, 20Amps for hot Glycol Generator -03 Nos
Fabricating and installing perforated mild steel cable trays of size 150 mm width x 50 mm depth including horiontal anc vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with mild steel suspenders and including painting two coats of synthetic enamell paint over a coat zine chrome paint, all as specified and directed. (for cabling work in plant room)
Supply & fixing MV danger notice plate of 200mm x 150mm, made of mild steel atleast 2mm thick and vitreous enamelled white on both sides and with inscription in signal red colour in frontal side as required, all as specified
Providing No Smoking and flammable sign board as per requirement of petrolium rules and Each CCOE Nagpur, all as specified
M/S BHAT ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .