Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | ₹27.7 L | L1 | Accepted-AOC low |
| 2 | L2₹31.3 LRejected-AOC LUDHIANA CANAL CIRCLE LUDHIANA | LUDHIANA | PUNJAB | 141001 | ₹31.3 L | L2 | Rejected-AOC High |
| Sl No | Description | Qty | Unit | DILPREET SINGH AND COMPANY L1 | DARSHAN SINGH KALER AND COMPANY L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation by mechanical means(JCB or Hydraulic
excavator) in Trenches for pipe line with straight or open cutting in streets or open are including and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,including the cost of diversion for crossing over trenches for access to the houses, watching fencing, etc. and removal of surplus soil out side/inside the town involving lead upto
15 meter complete in all respect | 7,096.41 | cum | 85 ₹6.0 L | 100 ₹7.1 L |
| 2.00 | Earth work in excavation in foundations trenches
etc. in all kinds of soil where Pick-Jumper work is
not involved and not exceeding 2.0 metres depth
including dressing of bottom and sides of trenches,
stacking the excavated soil clear from the edge of
excavation and subsequent filling around masonry
in 15 cm, layers with compaction including
disposal of all surplus soil as directed
within lead of 30 metres. | 234.47 | cum | 185 ₹43,376.95 | 200 ₹46,894 |
| 3.00 | First class brick masonary 229 mm thick laid in
cement sand mortar 1.6 in foundation and plinth
including supply recarriage of bricks cement . | 121.06 | cum | 7,000 ₹8.5 L | 7,500 ₹9.1 L |
| 4.00 | 10mm thick cement plaster 1.4 on sides walls | 300.38 | sqm | 170 ₹51,064.60 | 200 ₹60,076 |
| 5.00 | 10mm thick cement plaster 1:4 on bed and top. | 89.57 | sqm | 130 ₹11,644.10 | 160 ₹14,331.20 |
| 6.00 | Reinforced cement concrete 1:2:4 hand mixed but including steel reinforcement | 2.51 | cum | 8,860 ₹22,238.60 | 9,000 ₹22,590 |
| 7.00 | Cement Conc.1:2:4 including supply, carriage &
with stone ballast or shingle | 26.13 | cum | 5,460 ₹1.4 L | 5,600 ₹1.5 L |
| 8.00 | Cement concrete 1:4:8 with brick ballast 40mm
gauge | 27.27 | cum | 4,300 ₹1.2 L | 4,500 ₹1.2 L |
| 9.00 | Lowering, jointing of RCC NP-2 plain end pipes
300 mm dia laying same to correct gradient and
alignment and jointing ends and fixing collars with
cement mortar 1:2 as per IS 458:2003 in alldepths | 5,338.29 | metre | 155 ₹8.3 L | 180 ₹9.6 L |
| 10.00 | jointing and cutting of RCC NP-2 plain end pipes
150 mm dia for vent pipe into Trenches and laying
same to correct alignment as per IS 458:2003 (
@2.50 metre / No) | 60 | metre | 80 ₹4,800 | 100 ₹6,000 |
Updated dates
Tender Value
₹26.2 L
EMD Value
₹52,458
Closing Date
18 Nov 2025, 12:00 pmClosed
Executive Engineer,
Ropar Canal and Ground Water Division WRD Punjab
Estimate for laying underground pipeline for watercourse at RD 66100/R of rohira Distributary
2025_WR_138276_2
07/22A/2025-26
Open Tender
Pipe Laying Works
60 days
Rohira Near malerkotla
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹52,458
Ropar Canal and Ground Water Division WRD Punjab
15 May 2026
11 Oct 2025
18 Nov 2025
11 Oct 2025
18 Nov 2025
11 Oct 2025
14 Oct 2025
Amount
Excavation by mechanical means(JCB or Hydraulic excavator) in Trenches for pipe line with straight or open cutting in streets or open are including and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,including the cost of diversion for crossing over trenches for access to the houses, watching fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
First class brick masonary 229 mm thick laid in cement sand mortar 1.6 in foundation and plinth including supply recarriage of bricks cement .
10mm thick cement plaster 1.4 on sides walls
10mm thick cement plaster 1:4 on bed and top.
Reinforced cement concrete 1:2:4 hand mixed but including steel reinforcement
Cement Conc.1:2:4 including supply, carriage & with stone ballast or shingle
Cement concrete 1:4:8 with brick ballast 40mm gauge
Lowering, jointing of RCC NP-2 plain end pipes 300 mm dia laying same to correct gradient and alignment and jointing ends and fixing collars with cement mortar 1:2 as per IS 458:2003 in alldepths
jointing and cutting of RCC NP-2 plain end pipes 150 mm dia for vent pipe into Trenches and laying same to correct alignment as per IS 458:2003 ( @2.50 metre / No)
Wrought Iron and mild steel ladders, framed grills, grating etc. complete fixed in position in D-tank
Providing & fixing M.S. foot rests made of 23x25 mm square bar including fixing in Haudis complete with cement concrete 1:2:4
Providing and fixing of Alfa Alfa Valve fitted on riser pipe to act as Nakka (D regulators) (300mm)
Centreing &shuttering for Concerte faces
Providing & Fixing of Steel Shutter Gate Assembly in Main Pipeline complete in all respect 300mm
Any Other Items
DARSHAN SINGH KALER AND COMPANY (BID ID -698145)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
BOQ_307557.xls
BOQ • 0.24 MB
retender1of9of66100.pdf
Tender Documents • 0.41 MB
Download all tender documents and submit your bid