Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.8 L+₹2.1 L (4.49%)Rejected-AOC | L2 | Rejected-AOC Being not L1 |
Tender Value
₹43.7 L
EMD Value
₹87,500
Closing Date
18 Nov 2022, 6:00 pmClosed
Shri M Saravanan, IDSE, GE
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
PROVISION OF TOILET BLOCK FOR TRAINEES AT 1 TRG BN OF 1 EME CENTRE AND PROVISION OF TOILET BLOCK CONSISTING OF 2 X WC AND 2X BATH ROOM 1 URINAL BEHIND TRH BLOCK AT M 5 OFFICERS MESS STAFF 1 EME CENTRE UNDER GE N SECUNDERABAD
2022_MES_554802_2
8625
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER NORTH SECUNDERABAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (NORTH) SECUNDERABAD
₹87,500
Yes
3 Jan 2023
28 Oct 2022
21 Nov 2022
28 Oct 2022
18 Nov 2022
4 Nov 2022
Amount
Surface dressing not exc 15 cm deep in hard and dense soil and getting out complete all as specified and as directed.
Excavation in trenches not exceeding. 1.5 m wide and not exceeding. 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed.
Returning filling including spreading, leveling, watering and well ramming in layers n.exe 25 cm in each layers in hard/dense soil complete all as specified and as directed.
Removing excavated materials in soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as foundation filling and mass concrete complete all as specified and as directed.
M&L for RCC M-25 using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC M-25 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for RCC M-25 using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC M-25 using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
Formwork to sides and soffits of lintel beams, roof beams with fair finished surfaces of concrete complete all as specified and as directed.
Formwork to sides of columns with fair finished surfaces of concrete complete all as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams complete all as specified and as directed.
Formwork to sides and soffits of slabs including supports, over hangings etc, for fair finished surfaces of concrete complete all as specified and as directed.
M&L for TMT bars 6 to 10mm dia, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for TMT bars 5 to 8mm dia, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in stirrups complete all as specified and as directed.
M&L for walling of random rubble, uncourced, well bonded, bedded and solidly hearted, build in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with using flyash bricks old size straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specified and as directed.
M&L for Half brick work with flyash bricks using old size bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:4 as in partition walls complete all as specified and as directed.
M&L for rendering 10mm thick on other than fair faces of brick surfaces built in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5mm thick in CM 1:4 with WPC @ 2% by weight of cement over 10mm thick in CM 1:6 on other than fair faces of brick surfaces built in cm (1:6) , finished even and smooth without using extra cement complete all as specified and as directed. Note: WPC will be measured and paid separately.
M&L for rendering 10mm thick finished fair and smooth surface without using extra cement in CM 1:4, in ceiling surfaces complete all as specified and as directed.
Supply only water proofing compound ISI marked complete all as specified and as directed.
M&L for preparing plastered surface of walls and applying three coats of white wash on wall complete all as specified and as directed.
M&L for preparing newly plastered surface and applying three coats of white wash on ceiling surfaces complete all as specified and as directed.
M&L for preparing plastered surface of walls and applying two coats of cement base paint over a coat of primer on wall surfaces complete all as specified and as directed.
M&L for Hard core of gauge nexc 63m, deposited, spread and leveled in layers n.exc 15cm thick, watered and rolled/ rammed to a true surface complete all as specified and as directed.
M & L for PCC 1:4:8 type D2 75mm thick using 40 mm graded stone aggregate as sub base to floor complete all as specified and as directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, for laying floor finishes complete all as specified and as directed.
M&L coloured glazed ceramic tiles 450x350x7mm thick, on vertical surfaces such as skirting /dados etc set and jointed in neat cement slurry/ paste and pointed in white cement with pigments complete all as specified and as directed.
M&L for 10mm thick rendering in cement mortar 1:4, on fair faces of brick work and finishing even & rough to receive glazed tiles etc complete all as specified and as directed.
S & F Vitreous china Squatting pan, Orissa pattern, size 580 x 440mm white, including 'P' or 'S' trap set in and including cement concrete bedding complete all as specified and as directed.
S & F Vitreous china pedestal pattern water closet white, including 'P' or 'S' trap set in and including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
S & F 10 litres capacity PVC low level flushing cistern including brackets complete fixed complete all as specified and as directed.
S&F Vitreous China bowl urinal flat back of size 465 x 355 x 265 mm white (minimum), with grating and union, out let pipe etc., for discharge complete all as specified and as directed.
S&F Vitreous china urinal partition white of size 310 x 700 mm complete all as specified and as directed.
S&F Vitreous China wash basin, white, flat back of size 550x400mm excluding ditto but including brackets, S&F PTMT waste coupling 32mm bore half or full threaded ( minimum weight 32mm- 45 gms), PVC waste pipe 32mm bore for WHB/ Urinal,15mm fancy pillar taps, cast copper alloy screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S & F GI tubing of size 15mm dia, medium grade, laid in floors/walls complete all as specified and as directed.
M&L for Cutting existing steel tubing for alterations or additions (Each cut measured) including making necessary threading and connection to the existing line to new line of 40mm dia of pipe complete all as specified and as directed.
S & F GI tubing of size 20mm dia medium grade, laid in floor/walls complete all as specified and as directed.
S & F GI tubing of size 40mm dia medium grade, laid in floor/walls complete all as specified and as directed.
S & F 15mm size fancy type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S & F 15mm fancy type Stop valves, cast copper alloy,chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F for stop valve 20mm bore, cast copper alloy, screwed down, high pressure, with or without crutch or butterfly handles, screwed both ends for iron pipes or unions and fixed complete all as specified and as directed.
S& F PVC connection 15mm bore with PTMT nuts of length 450mm complete all as specified and as directed.
S&F Salt glazed stoneware gully traps, square or round mounted type ' P' of size 150x150mm complete all as specified and as directed.
Supply & fixing UPVC/PVC (SWR) 75mm floor trap complete all as specified and as directed.
M & L for UPVC/PVC (SWR) pipes 110mm dia fixed to walls single socketed with rubber ring joints complete all as directed and as specified.
S & F 110 mm bore UPVC/PVC (SWR) vent cowl complete all as specified and as directed.
S&F UPVC/PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F for UPVC/PVC (SWR) pipes 75mm dia fixed to walls, single socketed with rubber ring joints complete all as specified and as directed.
Supply & fixing UPVC/PVC (SWR) junction single 'T' 110mm bore equal or unequal with access door complete all as specified and as directed.
Supply & fixing UPVC/PVC (SWR) bends 75mm bore, any radius with oval access door complete all as specified and as directed.
S& F three layer rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) hoisted and fixed in position of 1000 liter capacity complete including ball valves high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball screwed for iron pipe 25mm bore & fixed.(Minimum weight 210gms ), complete all as specified and as directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
S&F for Butt hinges of size 100 mm aluminium extruded section with galvanised MS hinge pin, anodised and fixed complete all as specified and as directed.
S & F 150mm long aluminium handles, cast type anodised extruded section and fixed complete all as specified and as directed.
S & F aluminium anodized barrel tower bolt of extruded section of size 150 mm long complete all as specified and as directed.
S&F ventilator made with 5mm PVC sheet a overall outer dimensions of size 600 x 600. The rails and styles shall be 40x57mm duly reinforced with 19x19mm steel tube. The ventilator is divided into two equal part panels with mullion of 62x57 mm. The bottom portion of the ventilator is fitted with 3.5mm pin head glass and top portion is divided with louver arrangement for placing the glasses including 12mm dia 2 Nos of bars in each panels complete all as specified and as directed.
M&L for Rolled mild steel in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete Fe 410 complete all as specified and as directed.
M&L for two coats of Synthetic enamel painting over primer on new steel surfaces including preparation of surfaces over 10cm width and complete all as specified and as directed .
M&L for rendering 15 mm thick in CM 1:4, using water proofing compound at the rate of 2% by weight of cement complete all as specified and as directed. Note: WPC shall be measured and paid separately.
M&L for providing water proofing treatment with APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150gm/Sqm) applied on primed surface priming coat as per the directions of Manufacturer) by forced (torch) application with 10cm overlaps and finally coating the surface with bituminous aluminum paint @ 100gm/Sqm complete all as specified
M&L 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as specified and as directed.
M & L rendering 15mm thick in CM 1:4 on other than fair face of brick work surfaces to be finished fair and even smooth with using extra cement and mix with 2% water proofing compound by weight of cement (WPC measured separately a supply only) complete all as specified and as directed. Note: WPC shall be measured and paid separately.
Extra over forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc.complete all as specified and as directed.
M & L for precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded agg) as in cover slab for man hole set in CM 1:6 complete all as specified and as directed.
S & F 150mm internal dia of NP3 RCC drain pipe grade 'A' laid in trenches laid and jointed complete with collars and jointed as specified and as directed.
M&L for Concrete bed with cement concrete 1:4:8 type D2 using 40mm graded stone aggregate to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested of 150 mm bore complete all as specified and as directed.
M&L for Provision of 100 users RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-25 Design Mix in Walls, Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter all as per TD Drawing No: CECZ TD/ST/795/Sheet 1/2 & 2/2.
M&L for Soakage wells 1.80 M dia x 3.00 mtr depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonry in cement mortar, RCC cover slab in M-25 & SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size all as per TD Drawing No: CECZ/TD/ST/747/ Sheet 1/1 (For dimensions purpose only).
M&L PCC 1:2:4 type B1, using 20 mm graded aggregate as in benching and surface channels for man holes or drains etc., including necessary formwork complete all as specified and as directed.
M & L rendering 15mm thick in CM 1:4 on other than fair face of brick work surfaces to be finished fair and even smooth without using extra cement complete all as specified and as directed.
M&L for Plain Cement Concrete 1:2:4 type B-1 (12.5 mm graded aggregate) as in coping, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
M&L for Cement concrete in surface channels and drains using PCC 1:3:6 type D2 using 40mm graded stone aggregate including necessary form work etc complete all as specified and as directed.
Extra cover forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends for add or deduct for each 25mm girth or part thereof over or under 30 cm inner girth complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard and dense soil complete all as specified .
M&L for designer rubber moulded chequered cement concrete tiles with mixture of grey and white cement in equal proportions with pigments of size 300 x 300 x 22mm or 250 x 250 x 22mm thick and set and pointed in neat cement slurry in floors over a screed bed or bedding layer in CM 1:6, 15mm thick for laying floor finishes etc complete all as specified and as directed.
M&L for Rolled mild steel in plates(plain or chequered) channels, square cut or notched (ordinary and counter sunk) Fe-410-W(Gde-E-250) quality B forming holes without any attachment complete all as specified and directed
M&L for Rolled mild steel in steel structure/frame made of MS box/pipe sections ERW or induction butt weld tubes conforming to IS-1161-1979 grade st 240 as in columns,purlins and truss complete fitting as directed including one shop coat of red oxide primer and two coats of synthetic enamel paint complete all as directed.
S&F Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and as directed.
S & F GI tubing of size 25mm dia medium grade,laid in floor/walls complete all as specified and as directed .
S & F 15mm dia fancy type pillar taps, cast copper alloy screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F for brass CP towel rail 600mm long & including Chromium plated brass screws & wooden / plastic cleats (Minimum weight 190gms) complete all as specified and as directed.
Supply & fixing PVC (SWR) junction single 'Y' 110mm bore equal or unequal with access door.
Supply & fixing PVC (SWR) bends 100 mm bore, any radius with oval access door.
M & L for triple layer rotational moulded polyethylene water storage tank (cylindrical, vertical with classed top) hoisted and fixed in position of 1000 liter capacity complete all as specified and as directed.
M&L for ball valves high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball screwed for iron pipe 20mm bore & fixed (Minimum weight 210gms) complete all as specified and as directed.
S&F PTMT waste coupling 32mm bore half or full threaded (minimum weight 32mm- 45 gms) complete all as specified and as directed.
S&F PTMT waste coupling 40mm bore half or full threaded (minimum weight 40mm- 60 gms) complete all as specified and as directed.
S&F PVC waste pipe 32mm bore for WHB/ Urinal complete all as specified and as directed.
S&F Peg stay for a set of 3 pegs MS Powder coated complete all as specified and as directed.
S&F PTMT shelf fixed with and including chromium plated brass screws and wooden/ plastic cleats ( Min weight 300 gms) complete all as specified and as directed.
S & F salt glazed stoneware drain pipe (SGW) grade 'A' laid in trenches and jointed as specified of internal dia of pipe 150mm complete all as specified and as directed.
Material and labour for point wiring complete with stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded drawn through and including rigid 20mm dia PVC medium grade conduit and conduit accessories duly ISI marked on concealed etc., with new sunk type pressed steel terminal boxes suitable for switches duly painted with two coats of red oxide zinc chrome primer with suitable hylam sheet cover of suitable size for mounting of switches, regulators and drawing continuous earth wire with one run of 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade FRLS conforming to IS - 694 multistranded copper conductor as earth wire and connecting to common earth dolly and making good the disturbed wall surfaces to match with the existing surfaces complete all as specified and as directed for the following : (a) One light point/Bell point controlled by one, one way switch 5 amps, SP
All as per item No. 97 above, but one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
All as per item No. 97 above, but one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed.
All as per item No. 97 above, but one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed.
Material and labour for sub main wiring with two runs of single core FRLS PVC insulated, multistranded unsheathed copper conductor cable of size 2.5 square mm and drawing through PVC conduit of 20mm dia with accessories on surface in wall/roof along with one run of 2.5 square mm FRLS PVC insulated unsheathed multi stranded 1100 volts grade with copper conductor cable as earth continuity conductor connected to earth and earth dolly, connecting to main board duly making good the disturbed wall surfaces to match with the surroundings complete all as specified and directed. Note: 3 runs of 2.5 Square mm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre.
S & F switch piano single pole flush type 5 amps, 230 volts complete all as specified and as directed.
Supply and fix socket combination 2 in 1, multipurpose 3/5 pin 5 amps, flush type, 230 Volts complete all as specified and as directed.
Supply and fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket with single pole MCB 32 Amps 240 volts complete all as specified and as directed.
S & F lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with wooden round blocks complete all as specified and as directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed.
Supply and fix wall mounted LED batten with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 1 x 20w, 230 volts, bipin holders, DIFFUSED TYPE connector block internally prewired etc with 2 Nos PVC round blocks for mounting arrangements including all accessories with new 3 core multi stranded copper conductor of size 23/0.193 from ceiling rose to fitting and including LED Tube 20W including taking down existing unserviceable tube light fitting complete all as specified and as directed. Make : Havells cat No-REGALBATTENT8UPTO 1X22WSSBSWH incl Tube Rod cat No-PHOTONULTRA2.01213T8SSTL20WLED865SPC, Wipro cat No WI0921208 incl Tube Rod LL13-181-65SE, Philips Cat No - TMC501P1xT-LED22WP3241 incl tube rod 20w.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with suitable 40 mm dia GI bracket 0.60 Mtr length fixed on wall with 50x6 mm flat iron, clamps, nuts and bolts complete all as specified and as directed by Engr-in-Charge. Make - Havells Cat No - ENDCITYLITPLATE+SL35WLED757SASYBOPCWOSPD, Wipro Cat No LR13-501-XXX-57-XX, Philips Cat No - BRP030 LED35 CW MR PSU GR DX.
S & F sheet metal enclosure MCB DB SPN 12 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and as directed.
S & F MCB SPN 240 volts suitable for fixing in MCB DB of capacity 40 amps complete all as specified and as directed.
S & F MCB SP 5 to 40 Amps 240 volts for fixing on MCB DB's complete all as specified and as directed.
Material and labour for earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. NOTE: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, RCC cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete.
Supply and fix Exhaust fan, metal body, 300mm sweep, 900 RPM 230 volts AC Supply with louvers including opening in wall and fixing arrangement with nut bolts and making good the disturbed surface all as specified and as directed. Make Havells Cat No- Turbo Force SP equivalent in Bajaj/CG.
Supply and fix electric water heater, storage type steel body with glass coated inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated with ELCB plug top complete with all accessories such as safety valve, thermostat, NRV, connection piece, in and out going water connection pipe (Hot & Cold) etc complete all as specified. Make : Havells Model GHWAMGTWH025/Racold/V Guard.
Supply and Laying LT UG cable of size 2 core x 16 sqmm in trenches /floors/on wall /service connections XLPE insulated, PVC sheathed and armoured 1100 volts grade with aluminium conductor with necessary end terminal /cable gland as per site requirement including connecting to the main switches /cut outs MCB/MCCB with necessary lugs after cutting to required length complete all as specified and directed. Make : Havells/Polycab/Finolex
Supply and lay pre cast concrete cable covers class LV type-2, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
Supply , spread and filling approved sand in cable trenches for cushioning of LT UG cable complete all as specified and as directed.
Supply & lay G I tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement etc all as specified and directed of size 50 mm dia bore complete all as specified and directed.
S & F sheet metal enclosure MCB DB SPN 4 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and as directed.
Supply laying or fixing or passing through pipe, 1100volts grade heavy duty cable with PVC insulated aluminium stranded served with inner sheathing of PVC tape and overall PVC insulated in service connection suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire of size 10 sqmm twin core cable complete all as specified and directed.
Himagiri Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .