Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
14 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ADPC, RMSA TONK
ADPC, RMSA TONK
Repair work under Group-8 (in Panchayat Botunda and Kanwrawas) Block Todaraisingh
2025_RCSCE_511266_8
NIT 12 (TONK) /2025-26 RMSA TONK
Open Tender
Civil Works
Percentage
30 days
Tonk
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
ADPC, RMSA TONK/MD RISL JAIPUR
₹40,000
17 Nov 2025
4 Nov 2025
15 Nov 2025
4 Nov 2025
14 Nov 2025
4 Nov 2025
PART-A (Building Work) Based on Integrated Building BSR 2022 Rajasthan
1. GOVT. PS BHAIRUPURA MEENAN JHOPADIYA
Demolishing cement concrete manually / mechanical means including disposal of material within 50 mtrs lead as per direction of engineer-in- charge. 1:3:6 or richer mix.
Grading roof for water proofing treat ment with proofing compound with cenent concrete 1:2:4 (1 cement:2 coarse send:4 graded stone aggregate 20mm nominal size.
Grading roof for water proofing treat ment with proofing compound with Cement mortar 1:3 (1 cement : 3 coarse sand
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membran @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto-2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane. 3 mm thick
Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer in-charge.
Providing gola 75x75 mm in cement concrete 1:2:4 ( 1 cement ; 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 ( 1 cement : 3 fine sand ) as per standard design
Providing & fixing precast cement concrete coping 1:2:4mix50mm thick complete as per specification : staircases, balconies, girders, cantilevers, bands, coping, bed plates, blocks, sills, hjjas lintls, beam, plinth beam etc.
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
Applying one coat of Cement primer of approved brand and manufacture on wall surface including all scaffolding:
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. :
2. GOVT. PS KALYANSINGHPURA
Demolishing cement concrete manually / mechanical means including disposal of material within 50 mtrs lead as per direction of engineer-in- charge. 1:3:6 or richer mix.
Grading roof for water proofing treat ment with proofing compound with cenent concrete 1:2:4 (1 cement:2 coarse send:4 graded stone aggregate 20mm nominal size.
Grading roof for water proofing treat ment with proofing compound with Cement mortar 1:3 (1 cement : 3 coarse sand
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membran @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto-2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane. 3 mm thick
Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer in-charge.
Providing gola 75x75 mm in cement concrete 1:2:4 ( 1 cement ; 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 ( 1 cement : 3 fine sand ) as per standard design
Providing & fixing precast cement concrete coping 1:2:4mix50mm thick complete as per specification : staircases, balconies, girders, cantilevers, bands, coping, bed plates, blocks, sills, hjjas lintls, beam, plinth beam etc.
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
Applying one coat of Cement primer of approved brand and manufacture on wall surface including all scaffolding:
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. :
3. GOVT. PS KURASIYA
Demolishing cement concrete manually / mechanical means including disposal of material within 50 mtrs lead as per direction of engineer-in- charge. 1:3:6 or richer mix.
Grading roof for water proofing treat ment with proofing compound with cenent concrete 1:2:4 (1 cement:2 coarse send:4 graded stone aggregate 20mm nominal size.
Grading roof for water proofing treat ment with proofing compound with Cement mortar 1:3 (1 cement : 3 coarse sand
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membran @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto-2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane. 3 mm thick
Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer in-charge.
Providing gola 75x75 mm in cement concrete 1:2:4 ( 1 cement ; 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 ( 1 cement : 3 fine sand ) as per standard design
Providing & fixing precast cement concrete coping 1:2:4mix50mm thick complete as per specification : staircases, balconies, girders, cantilevers, bands, coping, bed plates, blocks, sills, hjjas lintls, beam, plinth beam etc.
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
Providingand laying inposition cement concrete including curing,compactionetc. Completei nspecifiedgr deexcluding thecostof centeringands huttering-Allworkuptoplinth level.
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing & polishing complet for area of each slab upto 2001 sq cm.
Brick work with clay flyash F.P.S. brick ( IS 13757- 1993 ) of class designation 75 in superstructure above plinth level upto floor five level in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 20 mm thick.
4. GOVT. SR. SEC. SCH. BOTUNDA
Demolishing cement concrete manually / mechanical means including disposal of material within 50 mtrs lead as per direction of engineer-in- charge. 1:3:6 or richer mix.
Grading roof for water proofing treat ment with proofing compound with cenent concrete 1:2:4 (1 cement:2 coarse send:4 graded stone aggregate 20mm nominal size.
Grading roof for water proofing treat ment with proofing compound with Cement mortar 1:3 (1 cement : 3 coarse sand
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membran @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto-2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane. 3 mm thick
Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer in-charge.
Providing gola 75x75 mm in cement concrete 1:2:4 ( 1 cement ; 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 ( 1 cement : 3 fine sand ) as per standard design
Providing & fixing precast cement concrete coping 1:2:4mix50mm thick complete as per specification : staircases, balconies, girders, cantilevers, bands, coping, bed plates, blocks, sills, hjjas lintls, beam, plinth beam etc.
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
5. GOVT. SR. SEC. SCH. RAMPURA
Demolishing cement concrete manually / mechanical means including disposal of material within 50 mtrs lead as per direction of engineer-in- charge. 1:3:6 or richer mix.
Grading roof for water proofing treat ment with proofing compound with cenent concrete 1:2:4 (1 cement:2 coarse send:4 graded stone aggregate 20mm nominal size.
Grading roof for water proofing treat ment with proofing compound with Cement mortar 1:3 (1 cement : 3 coarse sand
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membran @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto-2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane. 3 mm thick
Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer in-charge.
Providing gola 75x75 mm in cement concrete 1:2:4 ( 1 cement ; 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 ( 1 cement : 3 fine sand ) as per standard design
Providing & fixing precast cement concrete coping 1:2:4mix50mm thick complete as per specification : staircases, balconies, girders, cantilevers, bands, coping, bed plates, blocks, sills, hjjas lintls, beam, plinth beam etc.
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
Applying one coat of Cement primer of approved brand and manufacture on wall surface including all scaffolding:
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. :
6. GOVT. PS CHANDPURA
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix.
Dismantling stone slab roofing over wooden karries and battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:
Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:
Brick work with clay flyash F.P.S. brick ( IS 13757- 1993 ) of class designation 75 in superstructure above plinth level upto floor five level in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping, bed plates, blocks, sills, hjjas lintls, beam, plinth beam etc.
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. TMT bars (coforming of relevent IS code.)
Providing batta (gola) 75mm*75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design.
Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 20 mm thick.
PLASTER (Ceiling) 6 mm thick cement plaster to ceiling of mix 1:3 (1 cement:3 fine sand)
Distempering with oil bound washeble distemper of approved brand and manufacture to give an even shade including all scaffolding new work (two or more coats) over and including scrapping and priming coat with cement primer
Grading roof for water proofing treat ment with proofing compound with cenent concrete 1:2:4 (1 cement:2 coarse send:4 graded stone aggregate 20mm nominal size.
PART-B (Sanitary Work) Based on BSR PWD - 2022,
P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110mm dia
PART-C (Electric work )Based on PWD BSR - 2022
P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
7. GOVT. PS PUNRWAS COLONY BANEDIYA CHARANAN
Demolishing cement concrete manually / mechanical means including disposal of material within 50 mtrs lead as per direction of engineer-in- charge. 1:3:6 or richer mix.
Grading roof for water proofing treat ment with proofing compound with cenent concrete 1:2:4 (1 cement:2 coarse send:4 graded stone aggregate 20mm nominal size.
Grading roof for water proofing treat ment with proofing compound with Cement mortar 1:3 (1 cement : 3 coarse sand
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membran @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto-2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane. 3 mm thick
Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer in-charge.
Providing gola 75x75 mm in cement concrete 1:2:4 ( 1 cement ; 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 ( 1 cement : 3 fine sand ) as per standard design
Providing & fixing precast cement concrete coping 1:2:4mix50mm thick complete as per specification : staircases, balconies, girders, cantilevers, bands, coping, bed plates, blocks, sills, hjjas lintls, beam, plinth beam etc.
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
8. GOVT. SR. SEC. SCH. KANWARAWAS
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix.
Dismantling stone slab roofing over wooden karries and battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:
Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:
Brick work with clay flyash F.P.S. brick ( IS 13757- 1993 ) of class designation 75 in superstructure above plinth level upto floor five level in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping, bed plates, blocks, sills, hjjas lintls, beam, plinth beam etc.
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. TMT bars (coforming of relevent IS code.)
Providing batta (gola) 75mm*75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design.
Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 20 mm thick.
PLASTER (Ceiling) 6 mm thick cement plaster to ceiling of mix 1:3 (1 cement:3 fine sand)
Distempering with oil bound washeble distemper of approved brand and manufacture to give an even shade including all scaffolding new work (two or more coats) over and including scrapping and priming coat with cement primer
Grading roof for water proofing treat ment with proofing compound with cenent concrete 1:2:4 (1 cement:2 coarse send:4 graded stone aggregate 20mm nominal size.
PART-B (Sanitary Work) Based on BSR PWD - 2022,
P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110mm dia
PART-C (Electric work )Based on PWD BSR - 2022
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
9. GOVT. UPS BANEDIYA CHARANAN
Demolishing cement concrete manually / mechanical means including disposal of material within 50 mtrs lead as per direction of engineer-in- charge. 1:3:6 or richer mix.
Grading roof for water proofing treat ment with proofing compound with cenent concrete 1:2:4 (1 cement:2 coarse send:4 graded stone aggregate 20mm nominal size.
Grading roof for water proofing treat ment with proofing compound with Cement mortar 1:3 (1 cement : 3 coarse sand
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membran @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto-2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane. 3 mm thick
Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer in-charge.
Providing gola 75x75 mm in cement concrete 1:2:4 ( 1 cement ; 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 ( 1 cement : 3 fine sand ) as per standard design
Providing & fixing precast cement concrete coping 1:2:4mix50mm thick complete as per specification : staircases, balconies, girders, cantilevers, bands, coping, bed plates, blocks, sills, hjjas lintls, beam, plinth beam etc.
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand)
Applying one coat of Cement primer of approved brand and manufacture on wall surface including all scaffolding:
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. :
10. GOVT. UPS SALGYAWAS
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix.
Dismantling stone slab roofing over wooden karries and battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:
Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:
Brick work with clay flyash F.P.S. brick ( IS 13757- 1993 ) of class designation 75 in superstructure above plinth level upto floor five level in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping, bed plates, blocks, sills, hjjas lintls, beam, plinth beam etc.
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. TMT bars (coforming of relevent IS code.)
Providing batta (gola) 75mm*75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design.
Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 20 mm thick.
PLASTER (Ceiling) 6 mm thick cement plaster to ceiling of mix 1:3 (1 cement:3 fine sand)
Distempering with oil bound washeble distemper of approved brand and manufacture to give an even shade including all scaffolding new work (two or more coats) over and including scrapping and priming coat with cement primer
Grading roof for water proofing treat ment with proofing compound with cenent concrete 1:2:4 (1 cement:2 coarse send:4 graded stone aggregate 20mm nominal size.
PART-B (Sanitary Work) Based on BSR PWD - 2022,
P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110mm dia
PART-C (Electric work )Based on PWD BSR - 2022
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 9.90 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.43 MB
Tendernotice_2.pdf
PDF • 1.45 MB
Tendernotice_3.pdf
PDF • 0.12 MB
BOQ_911177.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .