| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC NO 1C CHROMPET KANCHIPURAM TAMIL NADU 600044 INDIA | CHENGALPATTU | TAMIL NADU | 600044 | L1 | Accepted-AOC ACCEPTED BEING LOWEST, COMPETITIVE AND REASONABLE | |
| 2 | L2₹26.2 L+₹1,030 (0.04%)Rejected-Finance | L2 | Rejected-Finance REJECTED NOT BEING L1 BIDDER | |
| 3 | L3₹26.5 L+₹35,990 (1.38%)Rejected-Finance FLAT NO S 4 DOOR NO 10 4 107 17 SRINIVASA TOWERS SRI RAMNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L3 | Rejected-Finance REJECTED NOT BEING L1 BIDDER | |
| 4 | L4₹26.6 L+₹45,270 (1.73%)Rejected-Finance 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | L4 | Rejected-Finance REJECTED NOT BEING L1 BIDDER | |
| 5 | L5₹27.8 L+₹1.6 L (6.04%)Rejected-Finance 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L5 | Rejected-Finance REJECTED NOT BEING L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹59,000
Closing Date
1 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DSSC
GE DSSC Wellington Barracks-Post, Wellington, The Nilgiris, Tamil Nadu,PIN-643231
MAINT AND REPAIR/ REPLACEMENT OF SECURITY/ STREET/ GARDEN LIGHTS AND ALLIED WORKS UNDER GE DSSC WELLINGTON
2021_MES_440399_1
8166/E8
Open Tender
Civil Works
Item Rate
180 days
WELLINGTON
PLEASE REFER TENDER DOCUMENTS AND NIT
8 documents required · 8 mandatory
₹500
GE DSSC WELLINGTON
₹59,000
Yes
13 Jul 2021
4 May 2021
3 Jul 2021
4 May 2021
1 Jul 2021
18 May 2021
60 days
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m depth for taking out, laying of cables etc and getting out in hard/dense soil incl connected items complete all as specified and directed. Note : Any damages made/caused to the HT/LT cables, Water Supply pipe lines , OFC Cables etc during the excavation works shall be made good by the Contr as per Original & to the entire satisfaction of Engr-in Charge & GE. Cost of the same is deemed to be included in the unit quoted rates.
Returning, filling in, including spreading levelling, watering and well ramming in layers n.exc 25 cm in depth (soil) all as specified and directed.
Removing excavated material (soil) to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed.
Supply and spreading clean dry sand (M sand) in trenches for cushioning/cable protection all as specified and directed. Note : Punned thickness shall be measured for payment.
Supply and laying sub class 'B' bricks laid across the cable for cable protection, above sand cushioning complete all as specified and directed.
M & L for providing PCC (1:2:4) type B-1, (using (20mm graded stone aggregate) for coping of poles including necessary form work etc complete all as specified and directed.
Taking out old unserviceable, burnt, punctured aluminium conductor cable LT, PVC/XLPE, 1100 volts grade, of cross sectional area upto 16 Sqmm all as specified and directed.
Supplying, laying, commissioning & testing of LT underground cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 4 core 16 Sqmm, including cable lugs, connection/termination complete all as specified and directed. Make : Havells/Finolex/Gloster
Supplying, laying, commissioning & testing of LT underground cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 2 core 10 Sqmm, including cable lugs, connection/termination complete all as specified and directed. Make : Havells/Finolex/Gloster. Note for item No 8 & 9 :- Wherever the cables are to be laid/fixed on poles/walls/other surfaces the cost of clamping using appropriate size/type of Saddles,MS Clamps,nuts both etc is deemed to be included in the unit quoted rates.
M & L for cutting the existing hard standing/PCC/WBM road at a depth not less than 45 cm and 25 cm in width for passing of cable through GI pipe, returning filling in, complete including finishing the surfaces by providing cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) upto 20 cm depth, finishing to a uniform smooth surface to match the existing surface complete all as specified and directed. Note : (i) GI pipes shall be measured and paid separately. (ii) Any damages made/caused to the HT/LT cables, Water Supply pipelines , OFC Cables etc during the excavation works shall be made good by the Contr as per Original & to the entire satisfaction of Engr-in Charge & GE. Cost of the same is deemed to be included in the unit quoted rates.
Supply and laying Galvanized Iron pipe medium grade of dia 50mm for cable protection in trenches/ducts/floors or fixed on walls / roof / poles etc including suitable fixing accessories complete all as specified and directed. Make : Tata/Jindal/Prakash. Note :- Wherever the protection pipes are to be laid/fixed on poles/walls/other surface the cost of clamping using appropriate size/type of MS clamps,nuts, bolts etc is deemed to be included in the unit quoted rates.
S & F LED 9W with base B22 WW 3000K suitable for Gate light/Garden light fittings including dismantling unserviceable lamp complete all as specified and directed. Make: Havells, Cat No : LHLDEUEEMC8R009 or techno-commercially equivalent in Philips/Jaquar
S & F LED 9W with base E27 WW 3000K suitable for Gate light/Garden light fittings including dismantling unserviceable lamp complete all as specified and directed. Make: Havells, Cat No : LHLDEUEEMC8R009 or techno-commercially equivalant in Philips/Jaquar
S & F LED 15W with base E27 WW 3000K suitable for Gate light/Garden light fittings including dismantling unserviceable lamp complete all as specified and directed. Make: Havells, Cat No : LHLDDEEEMC8R015 or techno-commercially equivalent in Philips /Jaquar
S & F Astronomical Timer switch unit operated on AC 110 - 240 V 24 hrs clock, day/week programmable time for controling street lights including taking down old unserviceable timer swiches complete all as specified and as directed. Make : L&T, Cat No : AUTS02DIG00 or techno-commercially equivalent in ABB/Legrand
S & F MNX 40 Power contactor of 40 Amps, AC 415 volts, TP for controling street lights including making connections and taking down old unserviceable contactor complete all as specified and directed. Make :L&T, Cat No : CS94190 or techno-commercially equivalent in ABB/Legrand
S & F loop in- loop out fuse junction box of internal dimension 200 x 140 x 95mm made out of FRP sheet and locking screw fitted with and incl 6 Amps MCB - 1 No, 20 Amps rated 4 way connectors for 3 phase and neutral incoming/out going, mounted in the box, fixing on steel tubular/rail poles including necessary aluminium clamps, suitable glands, lugs and GI nut and bolts including taking down old unserviceable junction box complete all as specified and directed. Make : Sintex, Cat No : GSJB-2014 or techno-commercially equivalent in Hensel/OBO
Supply, fix and test, in replacement of LED Street light fitting of capacity 90 Watts, CRI >70, power factor > 0.95, colour temperature 5700K, luminous efficacy not less than 100 lumen/watt, 9000 Lumens output, IP-66 protection including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection, phase to phase protection, over voltage protection, surge voltage protection etc) unit suitable for working voltage 140-270 V AC, 50 Hz, pressure die cast aluminium housing and finishing epoxy powder coated grey colour after phospho chromate treatment with all accessories and connecting up complete including taking down old unserviceable one all as specified and directed. Make: Havells, Cat No: ENDURAPEARLPLUS SL90WLED757SASYTOPCASTHO or techno-commercially equivalent in Philips/Jaquar
Supply, fix and test, in replacement of LED Street light fitting of capacity 60 Watts, CRI >70, Power factor > 0.95, colour temperature 5700K, luminous Efficacy not less than 100 lumen/watt, 6000 Lumens output, IP-66 protection including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection,phase to phase protection, over voltage protection, surge voltage protection etc) unit suitable for working voltage 140-270 V AC, 50 Hz, pressure die cast aluminium housing and finishing epoxy powder coated grey colour after phospho chromate treatment with all accessories and connecting up complete including taking down old unserviceable one all as specified and directed. Make: Havells, Cat No: ENDURAPEARLNEO SL60WLED757PASYTOPC or techno-commercially equivalent in Philips/Jaquar
Supply, fix and test, in replacement of LED Street light fitting of capacity 45 Watts, CRI >70, Power factor > 0.95, colour temperature 5700K, luminous Efficacy not less than 100 lumen/watt, 4500 Lumens output, IP-66 protection including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection, phase to phase protection, over voltage protection, surge voltage protection etc) unit suitable for working voltage 140-270 V AC, 50 Hz, pressure die cast aluminium housing and finishing epoxy powder coated grey colour after phospho chromate treatment with all accessories and connecting up complete including taking down old unserviceable one all as specified and directed. Make: Havells, Cat No: ENDURAPEARLNEO SL45WLED757SASYTOPC or techno-commercially equivalent in Philips/Jaquar.
Supply, fix and test, in replacement of LED Flood light fittings for Midmast, of capacity 150 Watts, CRI>70, Power factor >0.95 colour temperature 5700 K, luminous efficacy not less than 100 lumens/watt, colour temperature 5700K, 15000 lumens output, IP-66 including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection, phase to phase protection, over voltage protection, surge voltage protection etc) unit suitable for working voltage 140-270V AC, 50 Hz pressure die cast aluminium housing and finishing epoxy powder coated with all accessories as per manufacturer's instructions and connecting up complete including taking down old unserviceable one all as specified and directed. Make: Havells, Cat No: JETAIRISFLS150W LED757PSYMLTG or techno-commercially equivalent in Philips/Jaquar.
Supply, fix and test LED Flood light fittings for Midmast, of capacity 120 Watts, CRI>70, Power factor >0.95 colour temperature 5700K, luminous Efficacy not less than 100 lumens/watt, colour temperature 5700K, 12000 lumens output, IP-66 including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection, phase to phase protection, over voltage protection, surge voltage protection etc) unit suitable for working voltage 140-270V AC, 50 Hz pressure die cast aluminium housing and finishing epoxy powder coated with all accessories as per manufacturer's instructions and connecting up complete including taking down old unserviceable one all as specified and directed. Make: Havells, Cat No:JETA JETAIRISFLS 120WLED757APWBLTG or techno-commercially equivalent in Philips/Jaquar.
Supply, fix and test, in replacement of LED Flood light luminaire with high power of capacity 50 Watts suitable for working Voltage of 140-270 V AC, 50 HZ with in built power unit, electronic driver etc, pressure die-cast aluminum housing connecting up with all accessories including taking down unserviceable fitting complete all as specified and directed. Make: Havells, Cat No. JETAQUANTOPLUS FLP50WLED757SYMLENS or techno-commercially equivalent in Philips/Jaquar
Supply, fix and test, in replacement of LED Flood light luminaire with high power of capacity 30 Watts suitable for working Voltage of 140-270 V AC, 50 HZ with in built power unit, electronic driver etc, pressure die-cast aluminum housing with all accessories, connecting up including taking down unserviceable fitting complete all as specified and directed. Make: Havells, Cat No : JETAQUANTOPLUS FLP30WLED757SYMLENS or techno-commercially equivalent in Philips/Jaquar
S & F in replacement of building security light fittings 25W LED 6000K with IP 66 protection & fixing to the wall, using suitable GI bracket with the use of nut and bolts, making connections from ceiling rose including taking down old unserviceable one complete all as specified and as directed. Make : Havells, Cat No: ENDURAPEARLSL 25WLED757SASYTOPC or techno-commercially equivalant in Philips/Jaquar
S & F in replacement of Garden light LED bollard 8W, 3000K with aluminium landscape luminaire with IP65 protection with fixing accessories including taking down the unserviceable fitting complete all as specified and directed. Make : Havells,Cat No: MINIMOUNTBL10 WLED830PSYMTOPMMAM or techno-commercially equivalent in Philips/Luker
Note for item No 18 to 26 :- (i) Test certificates in support of the technical parameters of the light fittings is to be submitted in original to the Engr-in-Charge by the contractor. (ii) Design/Drawing/BOM/Technical specification of the LED fittings /fixture is to be submitted to the Engr-in-Charge /GE for approval wherever techno-commercially equivalency of the product/item is concern w.r.t given make/Cat Part is concerned. (iii) Decision of the Engr-in-Charge/GE shall be final & binding. (iv) Any items\ missing but technically required for effcient performance of the fittings/fixture is deemed to be included in the unit quoted rates. (v) Cost of suitable fixing arrangements like MS clamps, nuts bolts, washer etc to the entire satisfaction of Engr-in-Charge is deemed to be included in the unit quoted rates.
Supply only, driver suitable for 150W LED floodlight complete all as specified and directed. Make: Havells, Cat No:LHGDDDEHERBL150 or techno-commercially equivalent in Philips/Jaquar
Supply only, driver suitable for 120W LED floodlight complete all as specified and directed. Make: Havells, Cat No:LHGDDDCHERBL120 or techno-commercially equivalent in Philips/Jaquar
Supply only, driver suitable for 50W LED floodlight complete all as specified and directed. Make: Havells, Cat No:LHGDVDDBHQB1050 or techno-commercially equivalent in Philips/Jaquar
Supply only, driver suitable for 30W LED floodlight complete all as specified and directed. Make: Havells, Cat No:LHGDRDCBHOA1030 or techno-commercially equivalent in Philips/Jaquar.
Supply only, driver suitable for 90W LED streetlight complete all as specified and directed. Make: Havells, Cat No:LSSCRX2234 or techno-commercially equivalent in Philips/Jaquar.
Supply only, driver suitable for 70W LED street light complete all as specified and directed. Make: Havells, Cat No:LSSLOX0133 or techno-commercially equivalent in Philips/Jaquar.
Supply only, driver suitable for 45W LED street light complete all as specified and directed. Make: Havells, Cat No:LHGDBDEDGRAL045 or techno-commercially equivalEnt in Philips /Jaquar
Supply only, driver suitable for Bamboo garden light fitting 8W LED (driver only) complete all as specified and directed. Make: Havells /Philips/Jaquar
Supply and fix in replacement of bracket suitable for street light, made out of 40 mm dia 1.5 mtr length GI pipe light grade bent to shape fixed with suitable size of clamps (2 Nos), bolts, nuts and washers incl painting with one primer coat and two coats of aluminium paint complete including taking down old unserviceable one and all as specified and directed.
S & F in repairs rigid non-metallic PVC conduits of external dia 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends with aluminium clamp, bolt, nuts etc for fixing including taking down old unserviceable conduits complete all as specified and directed.
S & F in replacement PVC insulated flexible multicore round copper conductor cable of size 3 core 2.5 Sqmm including necessary end connector incl taking down unserviceable cable complete all as specified and directed. Make:Havells, cat No: WHMFDSKB32X5 or techno-commercially equivalent in Finolex/Polycab.
S & F in replacement of street light Control panel factory fabricated (CPRI type-tested) with MCB SPN 63 A, contactor 65 A, Digital Timer Control Panel, outdoor type including connected switch gears, cables, etc. and suitable sheet metal enclosure test and commisioning of Panel of 240V, out door cubical type with suitable provision of 25 x 25 x 3mm angular base and vertical frame along with necessary PCC foundation and locking arrangement including taking down old unserviceable one complete all as specified and directed. Make : IHXSS0312A of Havells or techno-commercially equivalent in Philips/Jaquar
Supply and fix in replacement of Street light control panel, factory fabricated (CPRI type-tested) with MCB TPN 63 A - 1 No, Contactor TP 65 A- 1No, Astronomical Timer Street Light Control Panel with accessories outdoor type including connected switch gears, cables, etc and suitable sheet metal enclosure test and commisioning of Panel of 440V, out door cubical type with suitable provision of 25 x 25 x 3 mm angular base and vertical frame along with necessary PCC foundation and locking arrangement complete including taking out old unserviceable panel all as specified and directed. Make: Havells, Cat No : IHXTS0912A or techno-commercially equivalent in Philips/Jaquar
Note for item Nos 39 & 40:- The quoted rate shall be inclusive of the following:- (i) Suitable copper control wiring inside Panel board, cable glands, cable lugs, supporting, insulators etc., (ii) Quoted rate is inclusive of angular base frame and PCC foundation, Earth work and connected accessories. (iii) The Panel should be mounted min 0.30m above the ground level, (iv) Design / drawing / BOM of the panel showing the dimensions is to be obtained from Manufacturer / Supplier & is to be got approved from the GE before placing final order to the manufacturer. (v) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
M & L for preparation of old painted surfaces of decorative stands/supports/fittings of garden light, scrapping with wire brush and applying one coat approved make/grade/color synthectic enamel paint after preparation of surfaces complete all as specified and as directed.
M & L for for preparation of old painted surfaces of decorative stands/supports of antique light fittings, scrapping with wire brush and applying synthetic enamal spray paint of approved make/grade of black color as base coat, copper color on body and gold color on existing design embosement as per existing after preparation of Surfaces to the entire satisfaction of Engr-in-Charge & GE complete all as specified and as directed. Note : (i) Ladders scaffolding, safety belts etc required for excavation of the works shall be arranged by the contractor & the cost of the same is deemed to be included in the unit quoted rates. (ii) Contractor shall be fully responsible for the safety aspects of the people engaged by him & any issues (if any) arising during the work shall be dealt by the Contractor & the Dept shall be no way responsible whatsoever.
M & L for preparation of old painted surfaces of street light steel tubular poles above GL/coping including cross arms channels, flat iron clamps by scrapping with wire brush and applying one coats of aluminium paint including pole numbering all as specified and directed. Note : (i) Ladders scaffolding, safety belts etc required for excavation of the works shall be arranged by the contractor & the cost of the same is deemed to be included in the unit quoted rates. (ii) Contractor shall be fully responsible for the safety aspects of the people engaged by him & any issues (if any) arising during the work shall be dealt by the Contractor & the Dept shall be no way responsible whatsoever.
M&L for repair of street light/flood light LED fitting of capacity 25W /30W /45W /50W /60W /72W /90W /120W/150W , disconnecting and bringing down from pole, fixing after repairs including replacement of unserviceable spare parts all as specified and directed. Note:- The unserviceable spare parts replaced shall be measured and paid seperately. Note : (i) Ladders scaffolding, safety belts etc required for excavation of the works shall be arranged by the contractor & the cost of the same is deemed to be included in the unit quoted rates. (ii) Contractor shall be fully responsible for the safety aspects of the people engaged by him & any issues (if any) arising during the work shall be dealt by the Contractor & the Dept shall be no way responsible whatsoever.
M&L for trimming/clearing of tree branches leaves etc all around street/security light fittings etc in such a way that there must be a clearance of atleast 1.5 Mtr radius from the street/security light fitting etc.So as to facilitate proper illumination complete all as specified & as directed. Note : (i) Ladders scaffolding, safety belts etc required for excavation of the works shall be arranged by the contractor & the cost of the same is deemed to be included in the unit quoted rates. (ii) Contractor shall be fully responsible for the safety aspects of the people engaged by him & any issues (if any) arising during the work shall be dealt by the Contractor & the Dept shall be no way responsible whatsoever.
Saket Enterprises
M.V.K.ENTERPRISES
AR Traders
rvelectricals
P K ENTERPRISES
Rajapriyaconstruction
KUMAR AGENCIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .