Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹21.5 L+₹1.4 L (6.85%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L2 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
23 Dec 2020, 6:00 pmClosed
GE 863 EWS
GE 863 EWS C/O 56 APO
SPECIAL REPAIR TO UNDER GROUND CABLE CONNECTIONS AN FEEDER PANELS AT 1841 PNR UNIT AT KARCHAM AND PROVN OF 100 KVA STABLIZER ALONGWITH LT CABLE AND PANEL BOARD INSTALLATION OF OP WORK SHELTER AT CENTRAL MI ROOM OF 2136 FD HOSP AT CHOLLING AREA AT KAR
2020_MES_370410_2
GE863/EWS-T-41 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
KARCHAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 863 EWS
₹56,000
Yes
23 Jan 2021
20 Nov 2020
26 Dec 2020
20 Nov 2020
23 Dec 2020
2 Dec 2020
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying underground cables/ errection of steeltubular poles / stay pit etc.complete all as specified and directed.
M&L for sand cushioning the UG cable screened unwashed river sand and punning for cushioning to cable complete all as specified and directed.
M&L for laying dry bricks old size with subclass 'B' made of burnt clay best quality locally available with permissible tolerance, laid straight in trenches for protection of cable complete all as specified and directed.
Returning, filling in incl spreading,levelling watering and well ramming in layer n exc .25 cm in soil complete all as specified and directed.
Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at alevel n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 60x60cmx6.30 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I 2009 connected to main switch board all as specified and testing on completion including necessary excavation, earthwork, PCC works in 1:2:4 type B-I (using 20 mm graded stone aggregate) and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 15 mm dia of light grade for protection of earth lead including taking out /dismantling of old earthing complete all as specified and directed.
Supply and laying in replacement GI pipe, 50mm bore dia, light grade for cable protection complete with all fittings fixed to wall or laid in floor/road crossing or on pole, complete all as specified and directed.
All as per item No 7 here-in-before but for 80 mm bore dia
Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminium conductor for working voltage upto and including 1100 volts, cross sectional area of cable 25 sq mm 3.5 core laid in trenches/fixed on pole/wall/passed through pipe including taking out old XLPE Cable complete all as specified and directed.
All as per item no 9 above but size 16 sqmm 4 core
All as per item no 9 above but size 35 sqmm 3.5 core
All as per item no 9 above but size 50 sqmm 3.5 core
All as per item no 9 above but size70 sqmm 3.5 core
All as per item no 9 above but size 95 sqmm 3.5 core
Supply and fix in replacement of on/off load Change over 4 pole with side handle , 400 Volt AC , 200 Amp with suitable sheet metal enclouser complete all as specified and directed. Make :Havells CAT No IHCFFE0100 or equivalent model of make as per appx 'B' as approved.
Supply installation, commissioning & testing Voltage stabilizer 100 KVA capacity for automatic operation servo controlled, three phase, naturally oil cooled, outdoor type IP-55 protection CPRI certified copper wound and designed for input variation between 300 V to 480 V suitable for unbalanced voltage in each phase with output voltage stabilized at 415 Volts with accuracy ± 1% on each phase and speed of correction 8 volts per second with initial filling of transformer oil having dielectric strength not less than 50 KV as per IS-335, complete with 0-500 volts voltmeter and arrangement to check input & output voltage, RYB indication lamp ampere meter high and low voltage cut off system, servo bypass switch overload and short circuit trip facility alongwith necessary PCC foundation casted in PCC 1:3:6 type C1 using 20mm graded stone aggregate, 150 mm above ground level with foundation bed and suitable form work complete all as specified and directed.
Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminium conductor for working voltage upto and including 1100 volts, cross sectional area of cable 95 Sqmm 3.5 core laid in trenches/fixed on pole/wall/passed through pipe complete all as specified and directed.
All as per item No. 19 above but size 70 sqmm 3.5 core
All as per item No.19 above but size 50 sqmm 3.5 core
All as per item No.19 above but size 35 sqmm 3.5 core
All as per item No. 19 above but size 25 sqmm 4.0 core
All as per item No. 19 above but size 16 sqmm 2.0 core
M&L for street light fitting 45Watt LED type, energy saving & environmental friendly long life Versatile pressure die-cast aluminium, IP65 roadway luminaire with high power LEDs as light source and electronic driver incl provn of PVC insulated unsheathed maltistranded copper conductor two core cable for connection from MS termination box to fitting, including GI pipe bracket 1.2mtr long, a pair of clamp, bolts, nuts, washers complete all as specified and directed.
Material & labour for Earthing complete with galvanised earth plate electrode 600x600x6.3mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised strip 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or of steel complete all as shown in electrical plate No 3 of SSR part-I 2009 connected to Voltage stabilizer/LT feeder pillar all as specified and testing on completion including necessary excavation, earthwork, PCC works in 1:2:4 type B-I (using 20mm graded stone aggregate) and CI earth pit cover with watering pipe 20mm dia GI pipe, medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade, for protection of earth strip including necessary excavation and earth work complete all as specified and directed. Note: 1. Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate. 2. GI strip upto 7.50 m from the top edge of earth plate is included under this item.
Net Contract Sum will be after deducting Sch Of Credit of Rs. 92414.00
R B TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .