Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.5 L+₹97,381 (2.66%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹37.5 L+₹98,592 (2.70%)Rejected-Finance KUTUMB 143 40 VINAYAK NAGAR INDALPUR ROAD NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | UTTAR PRADESH | 211008 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹37.8 L+₹1.2 L (3.35%)Rejected-Finance 139 11 104 MUTTHIGANJ ALLAHABAD UTTAR PRADESH 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹41.5 L+₹5.0 L (13.6%)Rejected-Finance AT PO DERA COLLIERY TALCHER DIST ANGUL ODISHA PIN 759103 | ANUGUL | ODISHA | 759103 | L5 | Rejected-Finance Being L5 |
Tender Value
₹43.6 L
EMD Value
₹87,500
Closing Date
19 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Spl repairs to certain Bldgs inside depot area at OD Fort Allahabad.
2022_MES_509082_1
8542/E8
Open Tender
Civil Works
Item Rate
180 days
Allahabad
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹87,500
Yes
12 May 2022
18 Feb 2022
21 Mar 2022
18 Feb 2022
19 Mar 2022
5 Mar 2022
18 Feb 2022 - 25 Feb 2022
60 days
Amount
Screed bed 10mm thick in CM 1:3, mixed with water proofing compound, over roof slab, finishing the surface even and fair, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Brickwork with sub class "B" bricks, straight or curved on plan exceeding 6metre mean radius, built in CM 1:6, complete all as specified and directed.
Providing water proofing treatment over cleaned roof surface with bitumenous membrane weight not less than 3 kg per sq.m comprising of the following and testing of following: (a) Removing existing roof treatment & cleaning roof surface and applying One coat of Bitumen primer confirming to IS-3384-1965 @ 0.3 kg per sqm. (b) Applying a tack coat of hot blown bitumen 85/25 @ 1.2 kg/sq.m confirming to IS-702-1998 for water proofing membrane. (c) Providing polymeric water proofing membrane having weight not less than 3 kg per sq.m with 100 mm wide side or end lap and joint sealed with flamed torched pasted over full length. (d) Applying one coat of bitumenious aluminium paint over water proofing membrane.
Bricks, sub class "B", laid flat on roofs, old size bricks bedded and jointed in CM 1:6 and pointed flush in CM 1:3, bricks bedded on 25mm thick sand layer, complete all as specified and directed.
Bricks, sub class "B", laid flat on roofs, old size bricks bedded and jointed in CM 1:6 and pointed flush in CM 1:3, bricks bedded on 25mm thick sand layer, complete all as specified and directed. [Except bricks, including cleaning of bricks]
Taking down cement plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water including removing of all rubbish off from the site, complete all as specified and directed.
Rendering 15mm thick in CM 1:4, mixed with water proofing compound, on fair faces of brick work or concrete surfaces of walls, finishing the surface even and smooth without using extra cement, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint of approved colour over a coat of 1 mm wall care putty, complete all as specifed and directed.
Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of walls, finishing the surface even and fair, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash, complete all as specifed and directed.
Rendering 5mm thick in CM 1:4 on concrete surfaces of ceilings, finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of ceilings and applying two coats of white wash, complete all as specifed and directed.
Supply only integral water proofing compound, complete all as specified and directed.
Repair to RCC chajja projection in any position and height upto 12 m with 15mm thick CM 1:3 and width not exceeding 150mm, including brushing with cement slurry @ 3.0 kg/sqm, including necessary scafolding and finished surface even and smooth, edges champhered and rounded, making drip course on outer edge of projection, including taking down cement plaster of any description & scrubbing down with water including removing of all rubbish off from the site, complete all as specifed and directed.
Demolition of Reinforced Cement Concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including cutting of reinforcement as required to facilitate demolition and removing rubbish off the MD premises, complete all as specified and directed.
RCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounde or chamfered angles and throating and making good the demolished surface as existing wall to match, complete all as specifed and directed.
UPVC (SWR) 75 mm bore pipes single socketed ends, in any length with rubber ring joints, fixed to walls or laid in floors or trenches, fixed in repairs, complete all as specified and directed.
UPVC (SWR) bends ISI marked of any radius of 75 mm bore pipes jointed with cement mortar (1:4) or PCC 1:2:4, fixed in repairs, complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5sq.m but not exceeding 4sq.m each with shutters (without taking off shutters from the frames) including removing from site, complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5sq.m each with shutters (without taking off shutters from the frames) including removing from site, complete all as specified and directed.
Taking down shutter of any description exceeding 1 sqm not exceeding 2 sqm each complete all as specified and directed..
Plain, solid, of second class hardwood (sal) straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as specified and directed.
Glazed and skeleton shutters, 30mm thick, second class hardwood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), divided into squares with plain, chamfered or rounded mitered beads for securing glass/gauge complete all as specified in SSR Pt- I, section 8, clause 8.24(a) and as directed. Note: Glass or wire cloth, etc. in panels or sash squares shall be measured separately.
Flush shutters 30 mm thick, factory made, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, fixed in repairs, complete all as specified and directed.
Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, fixed in repairs, complete all as specified and directed.
Preparation of new steel and iron surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section and fixed, 150mm long, complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed 300mm long, complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel, and fixed, 100mm size, complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel, and fixed, 75mm size, complete all as specified and directed.
Aluminium alloy handles, cast type, anodised, 150mm long, complete all as specified and directed.
Mild steel ordinary rat tail rod pattern springs including roller and roller plate complete, 300mm size, fixed in repairs, complete all as specified and directed.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specifed and direcetd.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, fixed in repairs, complete all as specifed and direcetd.
Preparation of new wooden surfaces exc 10 cm width or girth with sand or emery paper & applying two coats of synthetic enamel paint over a coat of pink primer , complete all as specified and directed.
Sheet glass, 3mm thick, ordinary quality and glazing in squares not exceeding 0.5 sq. m in each pane with oil putty, complete all as specified and directed.
Preparation of old wooden surfaces exc 10 cm width or girth with sand or emery paper & applying one coat of synthetic enamel paint, complete all as specified and directed.
Demolition of Concrete work (un-reinforced) in ground floors and pavings including floor tiles not exeeding 15 cm thickness (below or above ground level) and removal of debris from the site, complete all as specified and directed.
Plain cement concrete 1:2:4, 100 mm thick, type B-2 (using 40mm graded crushed stone aggregate) as in floor, finished even and smooth without using extra cement, complete all as specified and directed.
Plain cement concrete 1:2:4, 50 mm thick, type B-1 (using 20mm graded crushed stone aggregate) as in floor, (laid in alternate panels) including use and waste of form work finished even and fair, complete all as specified and directed.
Wearproof topping, 20mm thick (incorporating an approved metallic floor hardner in the ratio of 1 part of hardner : 4 parts of cement in dry state), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner), complete all as specified and directed. NOTE:- Metallic floor hardner shall be measured as 'Supply only' under resepctive items of this Schedule.
Supply only approved metallic floor hardner, complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position, including removing nut, bolt etc, complete all as specified and directed..
Second class hardwood in scantling clean sawn timber framed, fixed as girder, lintels, wall plates, joist purlin, rafters, complete all as specified and directed.
Dismantling of AC corrugated or semi corrugated sheet including AC ridges as in roof covering or wall etc, complete all as specified and directed..
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 MPa as in roof covering / cladding to wall, valley gutter, ridge hips etc, fixed with self tapping screws, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 MPa as in roof covering / cladding to wall, valley gutter, ridge hips etc, fixed with self tapping screws, complete all as specified and directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side of wood grain printed PVC sheet & edges will be painted to match with the printed sheet and reinforced with M.S. Square tube, complete all as specified and directed. MAKE:- Sintex / Rajshree plastic / Wood Forex, Indore
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification, complete all as specified and directed. MAKE:- Sintex / Rajshree plastic / Wood Forex, Indore / M/s Kumar Arch Tech Ltd.
Preparation of new plastered surfaces of walls and applying two coats of acrylic emulsion paint of approved colour over a coat of alkali resistant primer over 3mm thick wall care putty finish, complete all as specifed and directed.
Preparation of old decorated plastered surfaces of walls including cornices, pilastered etc, by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and applying two coats of acrylic emulsion paint of approved colour & shades including washing of floor, cleaning of glass, joinery, electrical fittings, wires etc, of drops & splash complete all as specified & directed.
Complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including preparation of surfaces by rubbing with appropriate size of sand or emery paper and applying two coats of cement base paint on walls surface, complete all as specified and directed.
Plain cement concrete 1:2:4, 25 mm thick, type B-1 (using 20mm graded crushed stone aggregate) as in sub base, finished surface rough to receive top layer, complete all as specified and directed.
Disamntling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillet, complete all as specified and directed..
Supply and fixing in repair E-board Make: Everest, Design "Lake and Hill" of size 605mm x 605mm x 4mm thick white prelaminated set embossed reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped galvanised iron imposed grid with 24mm wide T-section (White powder coated). The framework shall comprise of main runner made from 0.33mm thick GS sheet and of size 24mm x 32mm x 300mm and secured at 1200mm maximum centres securely fixed to structural soffits with hangers of 2mm dia GI wire to be fixed with approved rawl plugs, adjusters and screws. Flush fitting of 1200mmm long cross Tee (with double stiching) to be interlocked between main runners at 600mm centre to form 1200mm x 1600 mm modules cross tee longer than 600mm to be supported independently. 600mm x 600mm doubles to be formed by fittings 600mm long cross tee centrally between the 1200mm cross tee. Perimeter wall angle shall be of 0.45mm thick GS sheet of size 19mm x 19 mm and 300mm long of white colour all as per manufacturers instructions, fixed in reapir, complete all as specified and directed. Make of Frame work : Armstong or equivalent
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Non - skid Ceramic, jointless, coloured tiles 7 to 8 mm thick, size of each tile shall be 400mm x 400mm, as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid over and including provision of 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
Glazed ceramic coloured tiles as in vertical surface of walls such as skirting / dado and risers to steps, size of tile shall be 350mm x 250mm x 7mm / 450 x 300 x 7 mm thick, set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigment to match the colour or shade of tiles, laid over and including provison of 10 mm thick rendering as in backing coat of tiles in cement mortar 1:4, complete all as specified and directed.
Non - skid Ceramic, jointless, coloured tiles 7 to 8 mm thick, size of each tile shall be 300mm x 300mm, as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid over and including provision of 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
Preparation of old steel and iron surfaces over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden or metal frames fixed with putty or beads etc, complete as specified & directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.
Taking down switches, distribution boards and old cut-outs etc., of any type and carefully along with the existing boards and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Taking down carefully sub-main wiring of any type and any numbers including earthwire surface type / concealed type and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn in existing PVC / Mild Steel conduit with 2.8mm thick prelaminated sheet cover of colour as approved and duly concealed in walls for housing switches, sockets, regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) The quoted rate shall deemed to include the cost of pressed steel terminal boxes, prelaminated sheet cover etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing complete all as specified & directed for following point wirings:-
(a) One light / fan / bell / exhaust fan point, controlled by one one-way 5Amp switch
(b) One 5 pin, 5 Amp socket outlet point on an independent board.
(c) One 5 pin, 5 Amp socket outlet on the same board with other switches
Point wiring complete with 2.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn in existing PVC / Mild Steel conduit with 2.8mm thick prelaminated sheet cover of colour as approved and duly concealed in walls for one 15 Amp socket outlet on independent board, including 2.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) The quoted rate shall deemed to include the cost of pressed steel terminal boxes, prelaminated sheet cover etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing complete all as specified & directed.
Sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of rigid PVC conduit 25mm dia including conduit accessories and connecting terminal ends to DB's including providing 1 run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC conduit and conduit accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Switch piano, flush type single pole, one-way 5 Amp, ISI marked, complete all as specified and directed.
Socket outlet 2 in 1, 5 pin, 5A, flush type, ISI marked, complete all as specified and directed.
Switch piano, flush type single pole, one-way 15/16 Amp, ISI marked, complete all as specified and directed.
Socket outlet 2 in 1, 6 pin, 15/16 Amp, flush type, ISI marked, complete all as specified and directed.
Lamp holder, PVC polycarbonate body with back plate suitable for batten fittings, complete all as specified and directed.
Ceiling rose three terminal PVC / polycarbonate insulated body, surface bakelite type AC 50 Hz 230V, complete all as specified and directed.
Stepped (rotary) type electronic fan regulator (suitable for 1200mm / 1400mm sweep ceiling fan) flush type duly fixed on the existing phenolic laminated sheet etc. as required, 240V, humming free, complete all as specified and directed. MAKE:- Havells / L&T / Legrand
LED tube light fitting, 1x20W, LED 6000K, decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. Make: Havells E Lite Pride Plus Cat Part No LHEXBLP7PN1W020 or techno-commercially equivalent model in Philips / CG/ Bajaj
MCB DB, TPN, double door, factory made 6-way sheet metal enclosure with category of protection IP-42, 415V, with tinned copper 200Amp rated bus bar suitable for MCBs, with blank plates, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
MCB DB, TPN, double door, factory made 4-way sheet metal enclosure with category of protection IP-42, 415V, with tinned copper 200Amp rated bus bar suitable for MCBs, with blank plates, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
MCB DB, SPN, double door, epoxy powder coated, factory made 4-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, with blank plates, fixed in repairs, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
MCB DB, SPN, double door, epoxy powder coated, factory made 8-way sheet metal enclosure with category of protection IP-42, 240V, with tinned copper 200Amp rated bus bar suitable for MCBs, with blank plates, fixed in repairs, complete all as specified and directed. MAKE:- Legrand / Havells / L&T / ABB
MCB TPN, 63 Amp, 415 Volt, conforming to 'C' curve, 10kA breaking capacity, complete all as specified and directed. Make: Legrand/ Schneider/ ABB/ L&T/ Indo Asian
MCB SPN, 40 Amp, 240 Volt, conforming to 'B' curve, 10kA breaking capacity, complete all as specified and directed. Make: Legrand/ Schneider/ ABB/ L&T/ Indo Asian
Isolator / MCB SP 6/10/16/32 Amp, 240 Volt, conforming to 'B' curve, 10kA breaking capacity, fixed in repair, complete all as specified and directed. Make: Legrand/ Schneider/ ABB/ L&T/ Indo Asian
Isolator / MCB SPN 6/10/16/32 Amp, 240 Volt, conforming to 'B' curve, 10kA breaking capacity, complete all as specified and directed. Make: Legrand/ Schneider/ ABB/ L&T/ Indo Asian
Taking down existing ceiling fan / exhaust fan, any sweep, by disconnecting carefully all electric connection and refixing the same after necessary repair work as required (such as cleaning all the serviceable parts thoroughly, reassembling the fan after testing for proper functioning), with and including provision of electrical wire 3-core 23/0.0076 copper conductor, including provison of one coat of synthetic enamel paint of tint same as that of exisitng, including wiring of MES No on fan motor, complete all as specirfied and directed. NOTE : The quoted shall deemed to be inclusive of every minor items i.e., nut, bolts, screws, lugs etc., which are faily required for the smooth functioning of fans.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 20mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) mix with 8mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) If earth resistance is not found satisfactory, till satisfactory test result comes, the same shall be redone by the contractor without any extra cost to department.
Point wiring complete with PVC insulated unsheatehd, 1100 volts grade cable 1.5 sq.mm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories, including provision of concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer, with 2.8 mm thick top cover of plastic lmainated sheet of required colour for mounting switch, sockets, fan regulator etc, including 1.5 sq.mm FRLS type PVC insulated unsheathed cable multi stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and including chases cutting and making good the disturbed surface and applying finishes to match the existing surface, complete all as specified and directed for the following:-
(a) One light / fan / bell / exhaust fan point, controlled by one one-way 5Amp switch
(b) One 5 pin, 5 Amp socket outlet point on an independent board.
(c) One 5 pin, 5 Amp socket outlet on the same board with other switches
Point wiring complete with PVC insulated unsheatehd, 1100 volts grade cable 2.5 sq.mm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring for one 6 pin 15/16 Amps socket outlet on an independent board including provision of concealed opressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer, with 2.8 mm thick top cover of plastic lmainated sheet of required colour for mounting switch, sockets, fan regulator etc, including 2.5 sq.mm FRLS type PVC insulated unsheathed cable multi stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and including chases cutting and making good the disturbed surface and applying finishes to match the existing surface, complete all as specified and directed.
Recess mounting decorative LED fitting size 600 x 600 LED 34W high brightness SMD LED including suitable driver connection and testing complete all as specified and directed. Make: Philips Model pluto Panel Cat No PLUTOSURFACE2X2PLS34WLED857S or any techno-commercially equivalent model in Crompton/ Bajaj/Havells
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 to 32 Amps, C series, 10kA capacity, fixed in repairs, complete all as specified and directed.
shirdi sai builders
creative construction co.
DK Builders
M/S A P CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .