| 1 | 1₹12.4 LAccepted-AOC 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | 1 | Accepted-AOC BEING LOWEST TENDERER AND FULFILLING ALL THE REQUISITE CRITERIA | |
| 2 | 2₹17.7 L+₹4.9 L (37.9%)Rejected-Finance NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | 2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | 3₹18.1 L+₹5.2 L (40.5%)Rejected-Finance NO 23 SECOND MAIN ROAD RAJAMMAL NAGAR MADAMBAKKAM CHENNAI 600 126 | CHENNAI | CHENGALPATTU | TAMIL NADU | 600126 | 3 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 Dec 2023, 6:55 pmClosed
GE CHENNAI
GE CHENNAI FORT SAINT GEORGE CHENNAI 600009
REPAIR/ MAINTENANCE OF LT PANEL BOARDS/FEEDER PILLAR BOXES, CONTROL PANELS AND CONNECTED ACCESSORIES AT A, B AND D AREA UNDER GE CHENNAI
2023_MES_625637_1
8698
Open Tender
Civil Works
Item Rate
275 days
chennai
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE CHENNAI
₹40,000
Yes
2 Mar 2024
30 Oct 2023
8 Dec 2023
30 Oct 2023
1 Dec 2023
17 Nov 2023
Amount
Excavation in trenches in soft/ loose soil n. exc. 1.50m wide and n. exc. 1.50m deep and getting out complete all as specified and directed.
Returning filling in including spreading, levelling, watering & well ramming in layers not exceeding 25cm thick in soft/ loose soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and lay fine sieved excavated dry soil cushioning spreading levelling for cable trenches all as specified and directed (Punned thickness only shall be measured and paid) complete all as specified and directed.
Supply and laying burnt bricks, old size, sub class 'B', laid flat abutting each other, perpendicular to cable with width equal to width of brick laid in trenches for protection of cable incl taking out old unserviceable ones all as specified and directed.
Taking out the existing PVC/XLPE, 1100 grade, LT UG electric cable of size 95sqmm x3.5 core from trenches/ walls (or) passing through pipes/in floor and removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing complete all as specified and directed. Note:- Excavation and Earth work shall be measured and paid separately under appropriate items:-
All as per item No. 6.00 above but cable size 150 sqmm 3.5 core.
All as per item No. 6.00 above but cable size 185 sqmm 3.5 core.
All as per item No. 6.00 above but cable size240 sqmm 3.5 core.
Laying only the under ground cable obtained from Items No -06 above in trench/wall/floor etc. connecting with suitable cable lugs/sleeves etc. and size 95 sqmm 3.5 core complete all as specified and directed.
All as per item No. 10.00 above but cable size 150 sqmm 3.5 core obtained from item no 07 above.
All as per item No. 10.00 above but cable size 185 sqmm 3.5 core obtained from item no 08 above.
All as per item No. 10.00 above but cable size 240 sqmm 3.5 core obtained from item no 09 above.
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 95 sqmm 3.5 core conforming to IS specification complete all as specified and as directed.
All as per item No. 14.00 above but cable size 150 sqmm 3.5 core.
All as per item No. 14.00 above but cable size 185 sqmm 3.5 core.
All as per item No. 14.00 above but cable size 240 sqmm 3.5 core.
M&L cable jointing kit for PVC/XLPE/ LT UG cable jointing straight through heat shrink type joints complete with jointing material and accessories suitable for 95 sqmm 3.5 core cable incl taking down old unserviceable ones complete all as specified and directed.
All as per item No. 18.00 above but for 150 to 185 sqmm 3.5 core cable.
All as per item No. 18.00 above but for 240 to 300 sqmm 3.5 core cable.
Supply and laying GI tube light grade 100mm bore with suitable joints and clamps laid in trenches/ fixed on walls complete for cable protection including taking down old pipe complete all as specified and directed.
S& F for PCC type C-1 1:3:6 (20mm graded aggregate) complete all as specified and directed for making good the disturbed surface of walls/roads etc.
Fabrication and installation of cable route indicator made out of 10 mm thick CI plate , oval shape of suitable size and embossed with Mark of " MES LT Cable " including 30 cm length angle iron support and embedded in and including PCC and taking down old unserviceable ones complete all as specified and directed.
S& F for GI earthing strip 25x4 mm in trenches/walls and floors with saddles and fixing screws etc/through pipes etc and connecting to earth terminal complete including taking down old one complete all as specified and directed.
S&F of GI Strip of size 32 x6 mm in trenches/walls and floors with saddles and fixing screws etc/through pipes etc and connecting to earth terminal complete and taking down old unserviceable ones complete all as specified and directed.
Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 2 KVAR including incoming MCCB of suitable rating and connecting to distribution panel with suitable size of copper cables complete all as specified and directed.
Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 5 KVAR including incoming MCCB of suitable rating and connecting to distribution panel with suitable size of copper cables complete all as specified and directed.
Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 10 KVAR including incoming MCCB of suitable rating and connecting to distribution panel with suitable size of copper cables complete all as specified and directed.
Supply , install, testing and commissioning of cubical housing cabinet type LT feeder pillar of outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.Necessary foundation work as per manufacturer's instruction including foundation all as specified and directed of suitable size to accomodate and including the following accessories:- Note :- (i) The rate deemed to be inclusive of disconnecting the LT cable and reconnecting the same with suitable size of cable glands and connecting complete. (ii) LT danger notice with conventional skull and bones indication written with English and local language. (iii) Dismantling the old unserviceable panel and depositing where directed at site
Item No. 29.01 Contd/- Incoming (a) S&F for Electrolytic grade high conductivity solid 4 Nos Alu bus bars, rated 800 amps supported at required intervals sleeved with heat shrinkable PVC sleeves. The bars shall be colour coded at required intervals for identification - 04 Nos (b ) S&F for LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (C ) Digital multi function meter - 01 No (d ) S&F for MCCB 400 Amp 36 KA 4 pole Thermal magnetic setting complete - N0s -01 Outgoing (a ) S&F MCCB of 4 pole of capacity 125 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 04 Nos (b ) S&F MCCB of 4 pole of capacity 63 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 04 Nos
Supply , install, testing and commissioning of cubical housing cabinet type LT feeder pillar of outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3 mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.Necessary foundation work as per manufacturer's instruction including foundation and all as specified and directed of suitable size to accomodate and including the following accessories:- Note :- (i) The rate deemed to be inclusive of disconnecting the LT cable and reconnecting the same with suitable size of cable glands and connecting complete. (ii) LT danger notice with conventional skull and bones indication written with English and local language. (iii) Dismantling the old unserviceable panel and depositing where directed at site
Item No. 29.01 Contd/- Incoming (a) S&F for Electrolytic grade high conductivity solid 4 Nos Alu bus bars, rated 800 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - 04 Nos (b ) S&F for LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (C ) Digital multi function meter - 01 No (d ) S&F for MCCB 350 Amp 36 KA 4 pole Thermal magnatic setting complete - N0s -01 outgoing (a ) S&F MCCB of 4 pole of capacity 63 amps, with breaking capacity of 16 KA with fixed thermal & fixed magnetic setting - 02 Nos (b ) S&F MCCB of 4 pole of capacity 100 amps, with breaking capacity of 36 KA with fixed thermal & fixed magnetic setting - 03 Nos (c ) S&F MCCB of 4 pole of capacity 125 amps, with breaking capacity of 36 KA with fixed thermal & fixed magnetic setting - 03 Nos
M&L for repairs to existing LT Panel boards indoor/outdoor type and attending repairs such as replacement of hinges, locking welding work to corroded portion of panel board, preparation of complete surface for painting of panel board with two coats of synthetic enamel paint over a coat of red oxide primer (only for welded portion) complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion complete all as specified and as directed.. Note No-1 the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004.
muthu constructions
PREMIER ENGINEERING SYSTEMS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .