Tender Value
₹2.1 L
EMD Value
₹2,700
Closing Date
13 Mar 2024, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer (EnM), KSL Project
Staff Officer (EnM), GM Office, KSL Project
Repairing of HT Starters and HT Field Switches required prior Monsoon 2024 at Krishnashila Project.
2024_NCL_302786_1
NCL/KSL/EnM/Tender/2024/56 Dated 26.02.2024
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
Krishnashila Project
As per NIT
4 documents required · 4 mandatory
₹2,700
14 Apr 2024
27 Feb 2024
15 Mar 2024
27 Feb 2024
13 Mar 2024
28 Feb 2024
27 Feb 2024 - 5 Mar 2024
Amount
Repairing and Maintenance of 800KW, 6.6KV Starter unit, make- Andrew Yule Sr No.- 022
Indicating lamp (Red, Blue, Green, Yellow) 110 V AC/DC
Push button (Red, Blue, Green, Yellow )
Ammeter Ratio- (400/5) Scale 0-400
Panel window glass
Fibre Glass sheet
Supply and fixing of Digital Hour Meter
Supply and fixing of auxiliary contact 110V AC of VCB
Copper lug 2.5 sqmm
Cable tie
Dismantling and rewiring of control circuit of VCB starter
Painting of starter finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
Charge for overhauling and commissioning ( Including fixing of Sr. No 1 to 9 and any other material provided by NCL as per instruction of EIC)
CT, PT ratio polarity test.
Repairing and Maintenance of 716KW, 6.6KV Starter unit, Make- Electrotecnica, Sr. No. ET-73
Fibre Glass sheet
Supply and fixing of Digital Hour Meter
Supply and fixing of auxiliary contact 110V AC of VCB
Copper lug 2.5 sqmm
Cable tie
Dismantling and rewiring of control circuit of VCB starter
Painting of starter finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
Charge for overhauling and commissioning ( Including fixing of Sr. No 1 to 5 and any other material provided by NCL as per instruction of EIC)
CT, PT ratio polarity test.
Repairing and Maintenance of 716KW, 6.6KV Starter unit, Make- Electrotecnica, Sr. No. ET-73
Fibre Glass sheet
Supply and fixing of auxiliary contact 110V AC of VCB
Copper lug 2.5 sqmm
Cable tie
Dismantling and rewiring of control circuit of VCB starter
Painting of starter finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
Charge for overhauling and commissioning ( Including fixing of Sr. No 1 to 5 and any other material provided by NCL as per instruction of EIC)
CT, PT ratio polarity test.
Repairing of Field Switch unit, Make- Andrew Yule, Sr. No.- 215
Indicating lamp (Red, Blue, Green, Yellow ) 110 V AC/DC
Push button (Red, Blue, Green, Yellow )
Ammeter Ratio- (400/5) Scale 0-400
Panel window glass
Fibre Glass sheet
Supply and fixing of auxiliary contractor 110V AC (2NO+2NC)
Copper lug 2.5 sqmm
Cable tie
PVC copper cable 2.5 Sqmm
Dismantling and rewiring of control circuit wiring of VCB starter
Painting of field switch unit finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc complete.
Charge for overhauling and commissioning (Including fixing of Sr. No 1 to 9 and any other material provided by NCL as per instruction of EIC)
CT, PT ratio polarity test.
Repairing of Field Switch unit, Make- Electrotechnica, Sr. No.- VCB10404
Panel window glass
Fibre Glass sheet
Supply and fixing of auxiliary contractor 110V AC (2NO+2NC)
Copper lug 2.5 sqmm
Cable tie
PVC copper cable 2.5 Sqmm
Dismantling and rewiring of control circuit.
Painting of field switch unit finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc complete.
Charge for overhauling and commissioning ( Including fixing of Sr. No 1 to 6 and any other material provided by NCL as per instruction of EIC)
CT, PT ratio polarity test.
Repairing of Field Switch unit, Make- Meditron, Sr. No.- 41001171
Panel window glass
Fibre Glass sheet
Supply and fixing of auxiliary contractor 110V AC (2NO+2NC)
Copper lug 2.5 sqmm
Cable tie
PVC copper cable 2.5 Sqmm
Dismantling and rewiring of control circuit
Painting of field switch unit finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc complete.
Charge for overhauling and commissioning ( Including fixing of Sr. No 1 to 8 and any other material provided by NCL as per instruction of EIC)
CT, PT ratio polarity test.
Total impact of GST for the purpose of CTC
Sandeep and Co.
techsummary_313661.pdf
PDF • 0.21 MB
finsummary_313661.pdf
PDF • 0.21 MB
LOI-143.pdf
PDF • 1.77 MB
finance_313661.pdf
PDF • 0.02 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .