Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93.6 LAccepted-AOC 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC EMD recovered from RA Bills | |
| 2 | L2₹1.2 Cr+₹24.2 L (25.9%)Rejected-Finance 1001 SHIVALIK ABAISE 100 FEET ROAD OPP ANANDNAGAR APARTMENT PRAHALADNAGAR AHMEDABAD AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | L2 | Rejected-Finance Not quoted lowest price. | |
| 3 | Rejected-Technical 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | - | Rejected-Technical Not meeting the NIT requirement. | |
| 4 | Rejected-Technical HOUSE NO 2246 SECTOR 15 C CHANDIGARH | NA | NA | 160001 | - | Rejected-Technical Not meeting the NIT requirement. | |
| 5 | Rejected-Technical 91 B S G BARVE MARG KAMGAR NAGAR KURLA EAST MUMBAI MAHARASHTRA 400024 | MUMBAI SUBURBAN | MAHARASHTRA | 400024 | - | Rejected-Technical Not meeting the NIT requirement. |
Tender Value
₹1.4 Cr
EMD Value
₹2.7 L
Closing Date
15 Feb 2022, 5:30 pmClosed
Jt. GM (EE)
Jt. GM (EE), AAI, SGRDJ International Airport, Amritsar.
Annual repair, maintenance and operation of Conventional/Addressable Fire Alarm System with Auto Dialer facility and Fire Fighting system at SGRDJI Airport, Amritsar (for 02 years).
2022_AAI_103081_1
AAI/ASR/Engg-E/eNIT-12/2021-22
Open Tender
Electrical Works
Works
730 days
Amritsar Airport
As per Tender Document.
18 documents required · 18 mandatory
₹1,180
₹2.7 L
13 Aug 2022
26 Jan 2022
17 Feb 2022
26 Jan 2022
15 Feb 2022
26 Jan 2022
26 Jan 2022 - 31 Jan 2022
Amount
Operation and Maintenance Contract of Fire Alarm & Detection System at New Terminal Building, ATC-cum- Tech. Block, New Power House, Cargo Complex, AAI/BCAS Offie Complex, ASR/MSSR & SMR Building, DVOR, Localizer, Glide Path, NDB comprising of control panels, repeater panels, Manual Call Points, Detectors, Hootes, Mimic Panel, PA System, GSM/Landline based Autodialer, Batteries complete circuit & loop wiring etc. i/c all other associated accessories for satisfactory operation & making the system serviceable, periodically cleaning & testing all the associated accessories confirming to OEM specification and Special Terms and conditions attending the breakdown/ faults, preventive maintenance, ensuring serviceablility / satisfactory working condition of the system, maintenance of records / documentation etc. as per the detailed specifications, terms and conditions covered under this contract on all days including Sundays and holidays complete as required.
Operation and maintenance of Fire hydrant and sprinkler System on around the clock basis with the help of manpower as specified for New Terminal Building , ATC cum Technical Block, AAI/BCAS Office Complex, Air Cargo Complex ; comprising of different capacity of Electric pump motor sets, Diesel Engine Pump sets, De-watering pumps, Butterfly/sluice Valves, pipe line, Fire Hydrants, Sprinklers etc. as per good engineering practice complete in all respect as required and as per specification.
Replacement of B Check Kit for the following capacity Diesel Engine i/c replacement of multi grade oil as required.
118 Kw, Model - 6SL9088T (Kirloskar make)
Capacity 44.1 KW/ 60 HP , Model - 4R1040 NA (Kirloskar Make)
68 kw, Model - 6R1080 (Kirloskar Make)
Repairing, servicing sluice/ butterfly valves/ NRV etc. of different sizes provided in the fire system at various locations of fire hydrant and sprinkler system as required .(Item will be executed only if required)
Repairing & servicing of following capacity pump sets after dismantaling and providing all necessary defective/wornout parts such as nut-bolts, rubber gasket, gland dori, rubber coupling, suitable bearings etc. and re- assembling the pump, making the pump set in perfect working condition as per good engineering practice complete in all respect as required at site.(Item will be executed only if required)
Jockey Pump Set
Sprinkler Pump Set
Hydrant pump
Painting of Fire Hydtant/ Sprinklar pipeline of different sizes installed inside/ outside of terminal building / Cargo Terminal with two or more coats of painting with synthetic enamel paint to give an even shade, including cleaning of surface with detergent etc of approved brand or as approved by engineer-in-charge as required.
40 mm Dia
80 mm Dia
100 mm Dia
150 mm Dia.
200 mm Dia.
Supply and fixing of fire hydrant/ Sprinkler MS pipe line to bypass leaking underground inaccessible pipe line of following sizes inside/outside of terminal building on surface including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, flanges, gaskets, nuts, bolts and washers including MS Fabricated support of suitable size for MS Pipe hanging on wall with MS Angle, clamps, hangers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required.
100 mm Dia Class 'C'
150 mm Dia Class 'C'
200mm Dia Class 'C'
Supply and laying of fire hydrant/ Sprinkler MS pipe line to bypass leaking underground in accessible pipe line of following sizes inside/outside of terminal building on ground including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, flanges, gaskets, nuts, bolts and washers including support of brick work upto a height of 600 mm from ground surface including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade etc. complete in all respect as required.
100 mm Dia Class 'C'
200mm Dia Class 'C'
Replacement of existing damaged outdoor type hose cabinet by providing and fixing the new hose cabinet ( 1.0 m x 0.55m x 0.85m) made of not less than 3 mm aluminium sheet having central opening glazed door including necessary locking arrangement and painting work including also providing M.S. angles mounting frame suitable for accommodating external hydrant valve as per site requirement.
Replacement of the damage door locks of Internal / External Fire Hydrant box.
Replacement of the damage door glass and aluminium frame of existing External Fire Hydrant box.
Replacement of Pressure Gauges with new 150/100 mm dial Pressure Gauges including required modification and fixing of New 15 mm control valve and accessories as required at site.
Replacement of Pressure Switches including required modification, electrical connections, fixing of new 15 mm control valve if required and accessories etc., as per site requirement.
Constructing masonry chamber 90x90x100 cm inside with 7.5 class designation brick work in cement mortar 1:4( 1 cement: 4 coarse sand) for butterfly/sluice valve with C.I. surface box 100 mm top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix(1cement:2coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3( 1 cement : 3 coarse sand), 12 mm thick, finished with a floating coat of neat cement complete as per standard design with FPS bricks.
Providing and fixing of cast iron butterfly valves of following size on the existing M S Pipes, by cutting, and making exact gap on pipe and fixing including flanges, gaskets ,bolt ,nut & washers etc. as required:-
200mm dia
150mm dia
100mm dia
80mm dia
Providing and fixing of Non-Return valve (dual type wafer plate NRV) of following size including bolt ,nut, washers and rubber gasket as required:-
200mm dia
150mm dia
100mm dia
80mm dia
Providing and fixing of 150 mm dia “C” class MS pipe with 4mm wrapping coating as per IS 1022 : 2008 as required complete in all respect.
Providing and laying ”C” class M.S. pipe of following size including all forged fittings and accessories complete including welding, jointing and painting with one coat of primer & two coats of post office red enamel paint fixed, including chasing of walls/ columns/ceiling etc. and making good the same complete as required.
150mm dia
100mm dia
Providing and Fixing of 150 mm dia Dummy Plate.
Supplying & laying of 2 x 1.5 sqmm FRLS armoured cable, 600 / 1000V rated with annealed copper conductor as per applicable IS standared complete as required.
Supplying & drawing of 2 x 1.5 sqmm FRLS unarmoured cable, 600 / 1000V rated with annealed copper conductor as per applicable IS standared complete in existing surface / recessed steel / PVC conduit as required.
Supply of addressable optical smoke detector.
Supply of addressable multi detector.
Supply of addressable heat detector.
Supply of addressable manual call point.
Supply of loop driver card compatible with existing panel.
Supply of 12 V, 130 AH sealed maintenance free Battery (Battery Make-as per AAI Approved Make list))
Supply of 12 V, 150 AH sealed maintenance free Battery (Battery Make-as per AAI Approved Make list)
Supply of 12 volt,26 AH sealed maintenance free battery for fire alarm panels of Terminal buildings/MSSR.
Supply of 12 volt,7 AH sealed maintenance free battery for fire alarm panels at NAV AIDS
Supply of response indicator.
Supply of Control/ Monitor module.
Supply of 20 mm dia 30 mtr. Hose reel drum pipe.
Supply of 15 mtr. Hose pipe for hydrant point with male female stainless steel adaptors.
Supply of hydrant cap 63mm Dia
Supply of Nozzle ring (SS) 63mm Dia
Supply of hydrant coupling (SS) 63mm Dia
Supply of Nozzle of hose reel 20mm Dia
Supply of gland dori (heavy) for main / Jockey pump motor
Supply of hydrant wheel 63mm Dia
Supply of coupling lock (small and big)
Supply of Electonic Hooter Cum Speaker
Supply of conventional 02 Zone Fire Alarm Panel for NAV AIDS
CENTRE TAP ENGINEERING
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .