| 2 | L2₹40.8 L+₹2.7 L (7.17%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
REPAIR MAINT OF HT SUPPLY DISTRIBUTION SYSTEM AND CONNECTED ACCESSORIES AT JORHAT MIL STN
2023_MES_578722_1
84167E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE JORHAT
AS PER TENDER
7 documents required · 7 mandatory
₹500
Yes
GE JORHAT
₹80,000
Yes
2 Apr 2023
3 Feb 2023
8 Mar 2023
3 Feb 2023
6 Mar 2023
17 Feb 2023
4 Feb 2023 - 14 Feb 2023
Amount
M & L Calibratiion, testing, servicing and commissioning of 11 KV VCB and removing of breaker from existig HT panel and servicing to include cleaning, greasing,corbon removing with CRC/Jelly,Busbar cleaning,removing of sulphonification at Teminals/ busbars and checking the CT,PT working condition,fixing of insulated materials for Busbar and carried out calibration fro desired values (TMS,earth relay timing etc),complete testing and commissioning of 11 KV breaker capacity (As per existing Make / Model) (400 to 800 amp) for 11 KV VCB with panel Installed at different locations for proper functioning of the Installations complete all as specified and directed.( Each VCB will be servcied in one time in entire contract period.)
All as per Item No 1 above but 33/11 KV SF6 Circuit Breaker by opening all connections and checking all gases and same should be refilled. All Gases rate shall be deeemed to be included in the quoted rate only.
All as per Item No 1above but 33/11 KV MOCB Circuit Breaker. Note for Item No1 to 3:- (i) Servicing eqpt, moisture removing tools (Heating),cleaning tools,Insulated mtrl, for Busbars,Testing tools shall be deemed in quoted rates. (ii) Testing report duly signed by authorised person and contractor will be submitted to Engr-in-charge after servicing.
M&L for 4 Sqmm x 4 core copper conductor control cable for connection with CTs & PTs and transformer (Bucholz Relay) with their respective panel for better and effective protection of installations complete as per existing size & type with connecting accessories complete all as specified and directed.
M&L for 6 Sqmm x 6 core copper conductor control cable for connection with CTs & PTs and transformer (Bucholz Relay) with their respective panel for better and effective protection of installations complete as per existing size & type with connecting accessories complete all as specified and directed.
Dismantling insulators of any type and any size from HT 2/4 pole structures/pole after taking proper electric shut down from Engg in Charge complete all as specified and as directed.
S & F Pin type, porcelain, vitreous, white, brown or green insulator including one 19 mm dia galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia with top groove suitable for 11000 volts grade after taking proper electric shut down from Engg in Charge and restored electric supply after completion of each job and maintaining their record complete all as specified and directed.
S & F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green,two in series assembly for tension with tension GI clamps, Nuts, Bolts and washer etc suitable for working pressure 11000 volts grade after taking proper electric shut down from Engg in Charge and restored electric supply after completion of each job and maintaining their record complete all as specified and directed.
Dismantling cross arms of mild steel channel or angle sections etc. complete and removing unserviceable materials from site(s) complete all as specified and directed.
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified & as directed.
Dismantling of ACSR or AAC conductor from poles of any size & capacity and unserviceable materials removing from site(s) complete all as specified and as directed
M&L for Aluminium conductor steel reinforced (ACSR) of size as per existing for making connection at transformer, LAs, CT , PT, GOD,s & Drop out fuses etc complete all as specified and directed.
M & L for Stay assembly having stay rod dia 20 mm complete with all accessories such as mild steel galvanized flat iron stay clamp, all as shown in electrical plate No 1 of SSR Part-I complete all as specified and as directed. [Note : Excavation, earthwork and cement concrete work shall be measured and paid separately under relevant Items of this schedule].
M&L for Loop Insulator for stay assembly Overall dimensions 90 x 140 mm & clearance of hole 25.5 mm complete all as specified and as directed.
M&L for 7/4 mild steel galvanized stay Strand complete all as specified and as directed.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white in 11000 volts, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed.
M & L for switches air break switch, gang operated, triple pole, 11000 Volts grade and current rating up to 400 Amps, mechanically operated, mounted on insulator of size 150 mm dia and 150 mm hight and steel frame with operating mechanism worked from ground level having 3 Nos 11KV Post Insulators per phase with locking arrangements etc. and equipment shall be confirming to IS 9921 (Part I to V) including necessary electrical connections after taking down the old unserviceable GOD switches with all parts complete all as specified and as directed.
M&L for HT drop out expulsion fuse unit suitable for 100 Amps Capacity at 11 KV ,single pole (two post insulators per pole) with HT barrel fuse with holder including necessary connection to ACSR conductor of suitable size after taking down the old unserviceable drop out switches complete all as specified and as directed.
M&L for Two coats of Aluminium paint over a coat of red oxide zinc chrome primer including preparation of surfaces by spray painting external surfaces of steel tubular poles (HT/LT)/GI pipes /Panels at various Sub stations with approved colour code complete all as specified and as directed. Note: Colour code of eqpt/substation VCBs /Panels area for painting at shall got approved by GE
M&L for weather coat over including preparation of surfaces by spray painting external surfaces of PCC poles (HT/LT) at various Sub stations with approved colour code complete all as specified and as directed. Note:Colour code of poles for painting at shall got approved by ENgr-in-charge.
Supply ,laying, jointing, commissioning & testing HT UG cable of size 95 Sqmm 3 core, 11000 volts (earthed), aluminium conductor, XLPE insulated, earthed, screened, PVC bedded, armoured heavy duty electric cable conforming to IS-7098 (Part -II) 1985 with latest amendments drawn through pipe or laid in trenches, fixed on poles etc. including taking out the old unserviceable ones and stored as and where directed complete all as specified and as directed.
M&L for fixing and connection of lightening arresters set ( Set of 03 nos), non linear 12 KV, metal oxide type, distribution class 5 KA rupturing capacity for outdoor use with conforming to IS : 15086 PT- I of 2001, complete and suitable for 11KV supply system including taking down the old unserviceable ones complete all as specified and as directed.
Supply, jointing and testing HT heat shrinkable jointing kit straight through type for 11000 Volt grade 3 core XLPE insulated Earthed cable outdoor type complete with jointing material and accessories of size 95 Sqmm including taking down old unserviceable jointing kit complete all as specified and directed.
Supply, jointing and testing HT cable end jointing kit for 11000 Volt grade cable cold shrinkable outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable (Earthed) of size 95 Sqmm including taking down old unserviceable ones complete all as specified and directed.
Supply, jointing and testing HT cable end jointing kit for 11000 Volt grade cable cold shrinkable indoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable (Earthed) of size 95 Sqmm including taking down old unserviceable jointing kit complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supply and fixing HT Lightening arrestor ( Set of three) Station Class III, discharge capacity 65 Kilo Amps suitable for working voltage 33 KV with connected accessories like nut bolts, washers etc and making connections properly to earthing systems including taking down the old unserviceable ones complete all as specified and directed.
Excavation in trenches, for foundation of poles, stays or for laying of cables, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out as in soft / loose soil complete all as specified & directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil completer all as specified and directed.
Removing excavated material(soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Supply and laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 300mm x 230mm x 40 mm over burnt bricks laid dry and flat across the axis of cable, abutting each other with gaps between adjacent bricks not exceeding 10mm complete all as specified & as directed.
M&L for sand cushioning to underground cable in trenches with clean dry river sand for protection of cable complete all as specified and directed.( punned thickness will be measured).
M&L for boring /drilling by machines/manual horizontally under the road in any type of soil without cutting /disturbing the existing road and inserting GI pipe of any size for drawing the cable. complete all as specified & as directed.(GI Pipe shall be measured and paid separately).
M&L for cutting the road/ hard standing to a size not exceeding 30 cm in width not exceeding 75 cm in depth for laying/ removal of HT/ LT UG cable or cable protection pipe of any size including making good the disturbed surfaces by using PCC(1:4:8) type D2 (using 40 mm graded aggregates) for 100 mm thick on top including fair finishing complete all as specified and directed.
M & L for 80 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid on road crossing, drain crossing, laid in floor or fixed to iron structures /poles complete all as specified and directed.
Earthing complete with copper plate 60×60cm ×3.15mm thick electrode thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25mtr deep below ground level with top edge of the earth plate not less than 1.5mtr deep below normal ground level, connected with & including galvanized iron strip 32 x 6 mm earthing lead connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanized iron protected by 40 mm dia (light grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe , including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 54 x 54 x 5 cm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No. 3 of SSR part-I and testing on completion including taking out the old unserviceable earthing materials complete all as specified and as directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required20x3 mm copper strip complete all as specified and as directed.
Supply and fix in replacement of galvanised iron strip of size 25 x3.15 mm as earth continuity conductor or main earth lead fixed to wall on batten or recess or chases/roof of bldg or buried in groud or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc above ground all as specified.
Supply and fix in replacement of aluminium iron strip of size 25 x3.15 mm as earth continuity conductor or main earth lead fixed to wall on batten or recess or chases/roof of bldg or buried in groud or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc above ground all as specified.
M&L for preparation of old painted steel or iron external surfaces of transformer of capacity 1000-2000 KVA by scrapping with coir/ steel wire brush/scrapper emery paper, etc. and applying one coat of synthetic enamel paint of colour as approved by Eng in Charge by using spray machine including writing of SM No, MES No etc. at prominent place/location of transformer with black synthetic enamel thick paint in white back ground complete all as specified and directed. [Note: Necessary shut down of power supply should be granted from the Engr-in-Charge by the contractor before proceeding the work, also electric supply should be restored as early as possible after completion of the work]
M&L for painting works on surfaces of items as given below of 33 KV MRS at Lichubari comprising of following equipment/machinery fitted at yard by preparation of steel and iron of old painted surfaces smooth and applying one coat of synthetic enamel paint of existing colour and writing MES No, Name and capacity on plants of font size as ordered complete all as specified & directed by Engr-in-Charge. (i) HT Poles (Steel) for structures 11 meters long-12 no's (ii) Aluminium paint of Cross Arms/Channels of Approx Area 45 Sqm. (iii) Cement base weather proof painting of RCC (single) poles-06 no's. (iv) Scraping/ cleaning the surfaces of capacitor bank's panel and applying one coat of synthetic enamel painting - Qty -03 nos. (v) Weather proof painting on platform of Power Transformer, Earth Pit & Platform of Capacitor bank of the yard/MRS approx -43 Sqm. (Vi) Removing all boulders from site and placed them after washing with suitable chemical as directed by Engr-in-charge.
Disconnecting and takingout,repairing existing HT 33 KV APFC for seviceable & reuse (One No-150 KVAR & Two No-75 KVAR ) (Make : Areva) from housing and cleaning,rubbing and overhauling the mechanical parts and making serviceable of local/remote electrical operation of the panel including Greasing,oiling,replacement of UNSV Trip coil,breaker charging motor,gear pinion,roller switch and reassembling the same after replacement as required including testing (IR Test,Continuity Test,Tripping Test of earth fault and over current of panel) complete all as specified and directed (Note :All Spares parts of panel will be Measured and paid sepratly under respective items of this schedule here in after as supply only)
M & L of 4 pole/2 pole structure of 11 KV Gang operated devices Servicing, greezing,tightning of connections of conductors/HT cables,nut bolt etc,insluators(pin/disc) checking and cleaning the surfaces with CRC,aligniment of tripole gang with existing pins,jumpering,replacement of GI pipe for gang operations handle (medium garde,appx lenght 06 mtr) including clamps etc complete all as specified and directed.
M & L of 33 KV isolator/GODs Servicing, greasing,tightning of connections of conductors/HT cables,nut bolt etc,insluators(pin/disc) checking and cleaning the surfaces with CRC,aligniment of tripole gang with existing pins,jumpering,replacement of GI pipe for Isolator operations handle including clamps etc complete all as specified and directed. Note : Spare parts such as moving arm,operating pipe GI 32 mm,insulator base, MS channel 75x40x5 mm,fixed contact -copper flat (voltage 33 KV) shall be including in item quoted rates
Supply and fixing in replacement of the following spares for 11 Kv VCB (400 Amp-800 Amp) during servicing/overhaulingas per existing type and make at any location/installation under Jorhat stn complete all as specified and directed .
ISOLATING CONTACT - FLAT TYPE
VACUMM INTERRUPTER up to 650 Amps
VACUMM INTERRUPTER up to capacity 800 Amps
VCB Operating Mechanism (Mention Coil & Motor voltage) 650 to 800 Amp VCB
VCB Operating Mechanism (Mention Coil & Motor voltage) 400 to 650 Amp VCB
Closing Coil
Trip Coil
Spring Charging Motor
Closing Coil Box Assembly
Trip Coil Box Assembly
Motor Cut Off Lever Assy
Epoxy body
Buffer For Spring
Over Ride Stop
Over Ride Stop Pin
24 Pin Plug & Socket Assembly
Rack -In /Rack -Out Handle
Spring Charging Handle
Limit Switch Assembly
MI com digital relay as per existing Model/ make on VCBs or make of ABB
Material and labour painting of existing RCC cable route indicators ( both civil and mil area)with synthetic enamilled two coats of brown in colour and write with white colour letters for indication of joint/ area etc ,incl minor repairs with rendering,grouting at site complete all as specified and directed.
Dismantling of HT/LT connection at site from earthing lead carefully defective Transformer of capacity of 25 KVA to 315 KVA, 11 KV/440Volt, opening the top cover of the transformer at site, by removing nut, bolts, washer etc and lifting the core and winding by using triploid and chain pulley after removing LT/HT spindle with bushing and cleaning the yoke and winding/core and spindle bushing the same winding/core and spindle bushing and replace the worn out nut, bolts, washer gaskets etc with provision of cork sheets of 6mm thick (best quality) including necessary replacement of spares/ components complete all as specified and directed. (NOTE: Spares/ components required to be replaced shall be measured and paid as supply only under relevant items of this schedule.)
Disconnection of HT/LT connection, earthing lead and taking down carefully defective Transformer of capacity of 25 to 75 KVA, 11 KV/440Volt from 2/4 pole structure/Platform including transportation to factory/workshop including loading/ unloading and draining out existing transformer oil, opening the top cover of the transformer, by removing nut, bolts, washer etc and lifting the core and winding by using triploid and chain pulley after removing LT/HT spindle with bushing and cleaning the yoke and winding/core and spindle bushing the same winding/core and spindle bushing and replace the worn out nut, bolts, washer gaskets etc with provision of cork sheets of 6mm thick (best quality) and filling the transformer oil which was removed earlier, through stream line filter after dehydration and back to site after necessary repair & lifting of Transformer to its original position including necessary testing complete all as specified and directed
Disconnection of HT/LT connection, earthing lead and taking down carefully defective Transformer of capacity of 100 to 300 KVA, 11 KV/440Volt from 2/4 pole structure/Platform including transportation to factory/workshop including loading/ unloading and draining out existing transformer oil, opening the top cover of the transformer, by removing nut, bolts, washer etc and lifting the core and winding by using triploid and chain pulley after removing LT/HT spindle with bushing and cleaning the yoke and winding/core and spindle bushing the same winding/core and spindle bushing and replace the worn out nut, bolts, washer gaskets etc with provision of cork sheets of 6mm thick (best quality) and filling the transformer oil which was removed earlier, through stream line filter after dehydration and back to site after necessary repair & lifting of Transformer to its original position including necessary testing complete all as specified and directed
M&L for preparation of old painted steel or iron surfaces of transformer of 100 KVA to 300 KVA capacity by scrapping with steel wire brush/ emery paper etc and applying one coat of synthetic enamel paint smoke grey colour using spray painting machine complete including writing of SM No. , MES No etc. all as directed with black synthetic enamel paint on white background complete all as specified and directed.( Necessary shut down of power supply be obtained from Engr- in -Charge before the work and supply shall be restored immediately on completion of work.
M&L for preparation of old painted steel or iron surfaces of transformer of 25 KVA to 75 KVA capacity by scrapping with steel wire brush/ emery paper etc and applying one coat of synthetic enamel paint smoke grey colour using spray painting machine complete including writing of SM No. , MES No etc. all as directed with black synthetic enamel paint on white background complete all as specified and directed.( Necessary shut down of power supply be obtained from Engr- in -Charge before the work and supply shall be restored immediately on completion of work.
Supply only LT bush insulator as per existing size , shape and make for 100 to 300 KVA capacity transformer.
Supply only LT bush insulator as per existing size , shape and make for 25 to75 KVA capacity transformer.
Supply only LT brass/copper stud as per existing size , shape and make for 100 to 300 KVA capacity transformer.
Supply only LT brass/copper stud as per existing size , shape and make for 25 to 75 KVA capacity transformer.
Supply only gasket ( Set of four) for LT bushing as per existing size and shape for 100 to 300KVA capacity transformer.
Supply only gasket ( Set of four) for LT bushing as per existing size and shape for 25 to 75KVA capacity transformer.
Supply only top cover cork gasket set as per existing size and shape for 100 to 300 KVA capacity transformer.
Supply only top cover cork gasket set as per existing size and shape for 25 to 75 KVA capacity transformer.
Supply only HV bushing with brass terminal with nuts and washers and sheet gasket as per existing size and shape for 25 to 75 KVA capacity transformer.
Supply only HV bushing with brass terminal with nuts and washers and sheet gasket as per existing size and shape for 100 to 300 KVA capacity transformer.
Supply only breather assembly including silica gel of required quantity for 11/0.433 KV transformer for 100 to 300 KVA capacity .
Supply only breather assembly including silica gel of required quantity for 33/11 KV transformer of any capacity .
Supply, filling and topping up new transformer oil conforming to IS-335 of 1993 for filling/ topping up oil of transformer up to desired level complete all as directed. ( Dielectric strength of oil shall not be less than 40KV )
Dehydration and filtration of existing transformer oil of transformer at different location in site with filtration machine and heating system to get Di-electric strength of oil 40KV/cm minimum without disturbing the power supply system complete all as specified and as directed.
M/L rewinding of HT coils of transformer of any capacity using proper size copper DPC wire having class 'F' insulation as per existing size and turns including connected minor insulation materials suitable for HT coil of11/0.433 KV transformer complete all as specified and directed.
M/L rewinding of HT coils of transformer of any capacity using proper size copper DPC wire having class 'F' insulation as per existing size and turns including connected minor insulation materials suitable for HT coil of 33/11 KV transformer complete all as specified and directed.
M/L rewinding of LT coils of transformer of any capacity using proper size copper DPC wire having class 'F' insulation as per existing size and turns including connected minor insulation materials suitable for LT coil of 11/0.433 KV transformer complete all as specified and directed.
M/L rewinding of LT coils of transformer of any capacity using proper size copper DPC wire having class 'F' insulation as per existing size and turns including connected minor insulation materials suitable for LT coil of 33/11 KV transformer complete all as specified and directed.
M/L for cleaning of conservator oil tank of capacity 25 to 300 KVA transformers including refixing of rubber cork gasket as per existing size complete all as specified and directed.
Supply only 33 KV of copper tinned metal, having Capacity Tag on every fuse with rated HT fuses barrel type of capacity- 50 Amps and following IS, complete all as specified and directed.
All as per item no-93 but capacity- 30 Amps , complete all as specified and directed.
Supply only 11 KV of copper tinned metal, having Capacity Tag on every fuse with rated HT fuses barrel type of capacity- 30 Amps , complete all as specified and directed.
S&F Chemical earthing with copper earth plate 90x60cmx5mm & copper earth strip 50x6mm complete all as specified and directed.
PURBANCHAL BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .