Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
15 Nov 2021, 10:00 amClosed
Executive engineer
udhampur
33 kv line
2021_PDD_146397_1
24 of 2021-22
Open Tender
Electrical Works
Turn-key
90 days
reasi
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer ,STD Udhampur
Exempted
22 Nov 2021
3 Nov 2021
16 Nov 2021
3 Nov 2021
15 Nov 2021
3 Nov 2021
Amount
Realignment/shifting of 33KV Reasi -Sarh Bagga Line at locations i.e Geeta Nagar , Mari,Agar and Musra etc as per Layoutout Plan/Drawing attached.
Supply, Transportation, Erection of 11 Mtr Long ST Poles (ST410-SP56) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. at different locations near Mari reasi and Musra Mahore etc.
Supply, Transportation, Erection of 13 Mtr LongST Poles (ST410-SP56) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. at different locationsnear Mari reasi and Musra Mahore etc.
Supply and fixing MS cross arm 12feet long (100X50X6mm)
Supply and fixing MS cross arm 10feet long (100X50X6mm)
Supply and fixing MS cross arm 8feet long (100X50X6mm)
Supply and fixing MS Angle Iron belt 12 feet long (50X50X6mm)
Supply and fixing MS Angle Iron belt 07 feet long (50X50X6mm)
Supply and fixing MS Angle Iron Braces 6 feet long (50X50X6mm)
Supply and fixing MS Angle Iron Braces 14 feet long (50X50X6mm)
Supply and fixing MS Flat iron Clamps (50X6mm)
Supply and fixing Polymeric composite disc insulator 36 Kv with fittings complete ,min failing load 70KN ,Lighting impulse 170KV Positive and 180KV Negative,creepage distance 900mm
Supply and fixing Polymeric composite Pin Insulator36 Kv ,min failing load 10KN ,Lighting impulse 170KV Positive and 180KV Negative,creepage distance 900mm
Supply and fixing M S Flat Iron Ties(50X6mm)
Supply and fixing of Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete.
supply and fixing Guy wire
Providing,Laying and Stringing of ACSR conductor Dog on ST Poles including connection of jumpers etc..
supply and fixing Nuts and Bolts of sorts
Dismantling of existing ST Poles ,ACSR Conductor and Allied Material as per the directions of Incharge Engineer and write back of the same to the nearest receiving station..
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr Complete
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.6cum /pole Complete job
Painting of 11 /13 mtr poles including MS fixtures complete with anticorrosive aluminium Paint
Stabilisation of existing Reasi Sarh bagga Line by way of Shifting /insertion of poles and reconductoring of line from Malai area to Gangote area , and from Reasi to Arnas as per Layoutout Plan/Drawing attached.
Supply, Transportation, Erection of 11 Mtr LongST Poles (ST410-SP56) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. at different locations .
Supply, Transportation, Erection of 13 Mtr LongST Poles (ST410-SP56) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. at different locations.
Supply and fixing MS cross arm 10feet long (100X50X6mm)
Supply and fixing MS cross arm 8feet long (100X50X6mm)
Supply and fixing MS Angle Iron belt 10 feet long (50X50X6mm)
Supply and fixing MS Angle Iron brace 14 feet long (50X50X6mm)
Supply and fixing MS Flat iron Clamps (50X6mm)
Supply and fixing Polymeric composite disc insulator 36 Kv with fittings complete ,min failing load 70KN ,Lighting impulse 170KV Positive and 180KV Negative,creepage distance 900mm
Supply and fixing Polymeric composite Pin Insulator36 Kv ,min failing load 10KN ,Lighting impulse 170KV Positive and 180KV and as per IS.
Supply and fixing M S Flat Iron Ties(50X6mm)
Supply and fixing of Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete.
supply and fixing Nuts and Bolts of sorts
Providing,Laying and Stringing of ACSR conductor Dog on ST Poles including connection of jumpers etc.
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr Complete
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.6cum /pole Complete job
Painting of 11 /13 mtr poles including MS fixtures complete with anticorrosive aluminium Paint
supply and fixing Guy wire
Stabilisation of Existing Reasi Sarh Bagga Line by way of SITC of 33 KV Isolators at locations viz Musra, ganjote, Sunchal gali, Daman, Maslote, Kahiya, Salal, Aghar, etc as per the Layout Plan / Drawing attached.
Supply, Erection,Testing and Commissioning of 33 kV Isolator without Earthing Blade, 36kV,1250A, Outdoor, 3 poles, 25 kA Outdoor Type heavy duty ISI marked.
Supply and fixing of ACSR Dog Conductor for 33 KV isolator connection etc.
Supply and fixing of nut and bolts of sorts
Stabilisation/ improvemernt of 3.15 MVA Receiving Station Arnas and 6.3 MVA Receiving Station Darmadi
Supply ,Erection , Testing and Commissioning of of 33kvVCB (36KV,1250 A,26.2 KA, outdoor type Make Megawin, Crompton Greaves or Equvalent on already existing foundation including dismantling of old VCB including write back of the same to Sub Division at Receiving Stations.
Supply ,Erection , Testing and Commissioning of 33 kV Current transformer CTR 150/75-5A (33kv,1 phase multi ratio multi core, outdoor)I per phase on already existing structures and dismantling of old equipment including write back of the same to Sub Division at Receiving Stations.
Supply ,Erection , Testing and Commissioning of 33KV Voltage Transformer (33KV/110V ,1- phase multi-core, outdoor,1No. Per phase) on already existing structures and dismantling of old equipment.GI flat for earthing 50x6mm including write back of the same to Sub Division at Receiving Stations.
Supply ,Erection , Testing and Commissioning of 30 kv Lightening arrestors (30kv,10KA, Polymer) on already existing structures and dismantling of old equipment including write back of the same to Sub Division at Receiving Stations.
Supply ,Erection , Testing and Commissioning of 11 KV Isolator Gang Operated, heavy duty , double break, 3 pole,600 Amp with earth switch with internal copper flat of thickness not less than 3 mm.
Supply ,Erection , Testing and Commissioning of 33kv Isolator on existing structure with Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA )on already existing structures and dismantling of old equipment including write back of the same to Sub Division at Receiving Stations.
Supply ,Erection , Testing and Commissioning of 33kv Isolator on existing structure without Earthing Blade (36kv , 1250A,outdoor,3 poles, 25KA )on already existing structures and dismantling of old equipment including write back of the same to Sub Division at Receiving Stations.
Supply ,Erection , Testing and Commissioning of 33kv C&R Panel along with O/C, E/F relays , mimic diagram, Voltmeter, Ammeter, Annunciation windows with annunciation relays, 3-Phase Tri-Vector meter- % amps, DLMS Compliant including earthing on already existing structures and dismantling of old equipment including write back of the same to Sub Division at Receiving Stations.
Supply ,Erection , Testing and Commissioning of 12 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
Supply ,Erection , Testing and Commissioning of 4 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.GI flat for earthing 50x6mm
Supply ,Erection , Testing and Commissioning of 2 Core 2.5mm2 control cable copper armoured, 1.1KV Grade ISI,FRLS of make Havells, Polycab,etc.
Supply and fixing of nut and bolts of sorts
Providing of Earthing Complete by Chemical Earthing Complete
Supply ,Erection , Testing and Commissioning of GI flat for earthing 50x6mm
AJAY KAPOOR
M/S S S BUILDERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .