Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance 47 ABC TARUN NAGAR BY LANE 6 BY LANE 6 GUAWHATI KAMRUP ASSAM 781005 | KAMRUP METRO | ASSAM | 781005 | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.1 CrAdmitted-Finance ADD DHATKIDIH MARKET P O P S BISTUPUR DIST EAST SINGHBHUM JHARKHAND | ₹1.1 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical 603 ANAND BHAWAN OPP DR K K SINHA BARIATU ROAD RANCHI PIN 834004 JHARKHAND | RANCHI | RANCHI | JHARKHAND | 834004 | - | - | Rejected-Technical L.-921 |
| 4 | Rejected-Technical RANCHI JHARKHAND | RANCHI | RANCHI | JHARKHAND | - | - | Rejected-Technical L.-921 |
| Sl No | Description | Qty | Unit | SHIVAM AND COMPANY L1 | M/S BHARAT ENGINEERING L2 |
|---|---|---|---|---|---|
| 1.00 | Solar Module Mounting (Galvanised Steel) surface structure (for 10 KW) having Hot deep galvanised of Zinc thickness 80 micron and as per IS4759 with C Channel & anti theft with nut bolt of grade SS304,which should also withstand high wind velocity upto 150km/hr or as per MNRE. | 5 | Per set | 49,910 ₹2,49,550 Lowest | 51,500 ₹2,57,500 |
| 2.00 | 10kWp SPV module of 330wP or higher rating, which must have Specification as per IS 14286/IEC 61215 .The module must have to quilify IS/IEC 61730 part I & II (or having mechanical load test of 5400Pa) for safety purpose.Module to Module wattage mismatch in SPV Array shall be +/-3% and to qualify IEC TS 62804-:2015 for the detection of potential induced degradation and warranted for output wattage not less than 90% in 10yrs and 80% at the end of 25yrs as per MNRE. | 5 | Per set | 1,99,640 ₹9,98,200 Lowest | 2,06,000 ₹10,30,000 |
| 3.00 | USPC controller with SPV module/VFD integrated with GPRS,having MPPT ,Protection IP 65 or above as per MNRE to run 10HP AC induction motor pump set . | 5 | Per set | 39,928 ₹1,99,640 Lowest | 41,200 ₹2,06,000 |
| 4.00 | Solar cable 4 mm² used as per IS 694 or as per MNRE. | 100 | M | 52.9 ₹5,290.46 Lowest | 54.59 ₹5,459 |
| 5.00 | copper cable 95 mm² used as per IS 694 or as per MNRE. | 100 | M | 1,122.97 ₹1,12,297.5 Lowest | 1,158.75 ₹1,15,875 |
| 6.00 | Copper cable 16 mm² for earthing as per IS 694 or as per MNRE. | 50 | M | 211.62 ₹10,580.92 Lowest | 218.36 ₹10,918 |
| 7.00 | Supplying and commissioning of earthing and lighting arrestor and surge protection as per IS 3043,IEC62305-3 and IEC 63227 for 10 HP AC induction motor pump set. | 1 | Per set | 2,495.5 ₹2,495.5 Lowest | 2,575 ₹2,575 |
| 8.00 | 10 H.P. A.C induction motor Solar pump set of having performance with respect to Total Head,Maximum Current, Capacity, Voltage Range etc as per MNRE guidelines. | 5 | Per set | 77,859.6 ₹3,89,298 Lowest | 80,340 ₹4,01,700 |
| 9.00 | Miscllaneous Accessories for Installation of 10H.P. A.C induction motor Solar Pump(L.S) | 5 | Per set | 3,493.7 ₹17,468.5 Lowest | 3,605 ₹18,025 |
| 10.00 | Supplying,installation and commissioning Charge of module and Structure for 10kW. | 5 | Per set | 18,416.79 ₹92,083.95 Lowest | 19,003.5 ₹95,017.5 |
Tender Value
₹1.1 Cr
EMD Value
₹1.1 L
Closing Date
15 Jun 2026, 2:00 pmClosed
EE,M.I.DIV. RANCHI.
EE,M.I.DIV. RANCHI.
Construction of Mukhyamantri Solar Lift Irrigation Scheme At Nagrabera Village, Block-Angara,District-Ranchi.
2026_WRD_114971_1
WRD/MID/RANCHI/BD/SLI-05/26-27
Open Tender
Civil Works
Item Wise
335 days
RANCHI
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹1.1 L
3 Aug 2026
9 Jun 2026
16 Jun 2026
9 Jun 2026
15 Jun 2026
9 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Solar Module Mounting (Galvanised Steel) surface structure (for 10 KW) having Hot deep galvanised of Zinc thickness 80 micron and as per IS4759 with C Channel & anti theft with nut bolt of grade SS304,which should also withstand high wind velocity upto 150km/hr or as per MNRE. | 5 | Per set | 50,000 | ₹2,50,000 |
| 2 | 10kWp SPV module of 330wP or higher rating, which must have Specification as per IS 14286/IEC 61215 .The module must have to quilify IS/IEC 61730 part I & II (or having mechanical load test of 5400Pa) for safety purpose.Module to Module wattage mismatch in SPV Array shall be +/-3% and to qualify IEC TS 62804-:2015 for the detection of potential induced degradation and warranted for output wattage not less than 90% in 10yrs and 80% at the end of 25yrs as per MNRE. | 5 | Per set | 2,00,000 | ₹10,00,000 |
| 3 | USPC controller with SPV module/VFD integrated with GPRS,having MPPT ,Protection IP 65 or above as per MNRE to run 10HP AC induction motor pump set . | 5 | Per set | 40,000 | ₹2,00,000 |
| 4 | Solar cable 4 mm² used as per IS 694 or as per MNRE. | 100 | M | 53 | ₹5,300 |
| 5 | copper cable 95 mm² used as per IS 694 or as per MNRE. | 100 | M | 1,125 | ₹1,12,500 |
| 6 | Copper cable 16 mm² for earthing as per IS 694 or as per MNRE. | 50 | M | 212 | ₹10,600 |
| 7 | Supplying and commissioning of earthing and lighting arrestor and surge protection as per IS 3043,IEC62305-3 and IEC 63227 for 10 HP AC induction motor pump set. | 1 | Per set | 2,500 | ₹2,500 |
| 8 | 10 H.P. A.C induction motor Solar pump set of having performance with respect to Total Head,Maximum Current, Capacity, Voltage Range etc as per MNRE guidelines. | 5 | Per set | 78,000 | ₹3,90,000 |
| 9 | Miscllaneous Accessories for Installation of 10H.P. A.C induction motor Solar Pump(L.S) | 5 | Per set | 3,500 | ₹17,500 |
| 10 | Supplying,installation and commissioning Charge of module and Structure for 10kW. | 5 | Per set | 18,450 | ₹92,250 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
DOCUMENTS5.pdf
Tender Documents • 2.93 MB
BOQ_155478.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].