| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹22.8 L+₹4.6 L (25.4%)Rejected-AOC | L2 | Rejected-AOC High bid value | |
| 3 | L3₹24.3 L+₹6.1 L (33.5%)Rejected-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-AOC High bid value | |
| 4 | L4₹24.9 L+₹6.7 L (36.8%)Rejected-AOC | L4 | Rejected-AOC High bid value | |
| 5 | L5₹30.6 L+₹12.4 L (68.5%)Rejected-AOC 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L5 | Rejected-AOC High bid value |
Tender Value
Refer Docs
EMD Value
₹42,000
Closing Date
10 Jul 2023, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE 560006
REPAIR/ REWINDING OF CEILING EXHAUST/ WALL MOUNTED FANS AND GEYSERS INCLUDING SPARES OILING GREASING AND PAINTING AND EARTHING INCL LIGHTING ARRESTERS AT CHAF BANGALORE
2023_MES_590898_2
8998/GE/22
Open Tender
Civil Works
Item Rate
330 days
GE (AF) BANGALORE
AS PER NIT
6 documents required · 6 mandatory
₹500
GE (AF) BANGALORE
₹42,000
8 Sept 2023
16 Jun 2023
17 Jul 2023
16 Jun 2023
10 Jul 2023
24 Jun 2023
17 Jun 2023 - 20 Jun 2023
Amount
M&L in repair for earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically ( earth pit not less than 2.25 mtrs deep below ground level ) with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, connected to galvanised eath lead wire 4.00 mm dia by means of bolts, nuts ,check nuts & washers of G I or steel all as shown in electrical plate no 3 SSR part I connected to earthing test point all as specified or indicated including testing on completion.
All as per serial item No 1 above but using copper plate 60cmx60cmx3.15mm thick electrode and 20x3mm copper strip as earthing lead all as specified
M & L in repair earth continuity conductor GI wire 4.00 mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed any other indicated situation for direct/loop earthing with proper PVC/Porcelain insulator etc all as specified and directed .
M & L in repair earth continuity conductor GI Strip 25 x 4mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for direct/loop earthing with proper PVC/Porcelain insulator etc all as specified and directed .
M & L in repair earth continuity conductor copper Strip 20 x 3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for direct/loop earthing with proper PVC/Porcelain insulator etc all as specified and directed .
Supply and Fix in repair 25x3.15mm aluminium strip earth continuity conductor or main earthing lead fixed with porcelain /PVC insulator on wall or roof top floor or recess or chases or buried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc complete all as directed
S&F in repair of PVC Polymer/Porcelain insulator for existing GI/Aluminium/copper strip support all as specifed and directed
S & F in repair for Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm, drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screw complete fixed on wall in and including sheet steel enclosure of thickness 2 mm thickness with locking arrangement complete all as specified and directed.
S&F In repair air termination single pointed copper rod 12mm dia and 300mm long fixed on GI pipe 15mm approx 1mtr hight with base firmly on the roof top using PCC of size 30x30x30 cm and necessary screws,saddles all as directed
M & L for Repair/Reconditiong of exisitng earth pit by removing damaged Earth PCC chambers and excavate pit soil upto 25% of earth plate/electrode and adding alternate layers of charcoal, mixture of salt and copper sulphate up to 15cm above the earth plate/electrode and moist the mixture using water , cleaning/replacing of funnel with wire mesh where ever necessary ,testing the earthing after reconditioning that the earth resistance value should not be morethan 1.5 Ohms , making good to distrubed surface and all as specified and directed at site. Note: 1. Deemed including excavation, returning filling and connected items. 2. Salt , charcoal , copper Sulphate, pit chamber , Testing will be measured and paid seperatly
Supply only pure charcoal granular/aggregate type having Ash content < 5% , stone free for earthing
Supply only iodine free pure common salt crystal ( NaCl) for earthing
Supply only copper sulphate crystal (CuSO4) for earthing
M & L for Testing of earth resistance of existing earthing using calibrated 3/4 wire digital Earth resistance tester and recording the earth resistance value in register , obtaining the signature of user and MES executive after verification all as specified and directed by the Engr in charge. Note:- contractor has to provide digital earth resistance tester and should be available all the time during the contract period.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed/ surface type as required on ground with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Taking down the ceiling fans 1200/1400mm at site of any make and servicing of ceiling fan complete with greasing incl refixing the same after servicing checking properly by removing and replaced the unsv parts such as nut bolts, split pins rubber reel,necessary threading for rods etc.re-connecting the fans to ceiling rose/connector complete with 23 / 0.0076 " flexible twin core copper conductor cable from fan to ceiling rose/connector (rubber reel to be measured and paid against relevant items) and re-assembling the same with proper accessories and testing complete all specified and directed.
Taking down the exhaust fans 300/380/450 mm at site of any make and servicing of exhaust fan complete with greasing refixing the same after servicing checking properly by removing and replaced the unsv parts such as nut bolts, pins rubber bushes etc.re-connecting the fans to ceiling rose/connector complete with 23 / 0.0076 " flexible twin core copper conductor cable from fan to ceiling rose/connector and re-assembling the same with proper accessories and testing complete all specified and directed.
Taking down the wall mounted fan at site of any make and servicing of wall mounting fan complete with greasing refixing the same after servicing checking properly by removing and replaced the unsv parts such as nut bolts, split pins etc.re-connecting the fans to ceiling rose/connector complete with 23 / 0.0076 " flexible twin core copper conductor cable from fan to ceiling rose/connector and re-assembling the same with proper accessories and testing complete all specified and directed.
Supply and fixing ball bearing in replacement as per existing for ceing fan/exhaust fan/wall mounted fan.all as specified and directed.
S&F inreplacement rubber reel of suitable size for ceiling fan with necessary clamp and nut & bolt complete all as specified and directed.
S&F in repair capacitor of cap 2.5 MFD paper type for fans complete all as specified and directed.
S&F in repair capacitor of cap 3.15 MFD paper type for fans complete all as specified and directed.
S&F in repair capacitor of cap 4 MFD paper type for fans complete all as specified and directed.
S&F in repair gun metal bush of size suitable for ceiling fan shaft complete all as specified and directed.
Taking down ceiling fan ,sealing cable end dismantling blades and removing unserviceable fan and blades to store for repair all as specified and directed
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose /connector to fan all as specified and directed
M&L for rewinding of ceiling fan with super enamel copper wire as per existing size/gauge to achieve the required RPM as per manufacturers design including proper heating varnishing and provision of insulating etc and testing complete all as specified and directed of following sizes:-
Ceiling fan of size 1200mm sweep
Ceiling fan of size 1400mm sweep
M&L including taking down, for fan hook on RCC ceiling made by MS flat iron of size 40 x 5 mm and 66 cm length incl no nut bolt with wahser of size, suitable for hanging with pipe/angle/I section complete all as specified.
Taking down exhaust fan ,sealing cable end dismantling blades and removing unserviceable fan and blades to store for repair all as specified and directed
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose /connector to fan all as specified and directed
Rewinding of exhaust fan with super enamel copper wire as per existing size/gauge to achieve the required RPM as per manufacturers design including proper heating varnishing and provision of insulating etc and testing complete all as specified and directed of following sizes:-
Exhaust fan of size 300mm to 380mm sweep
Exhaust fan of size 400mm to 450mm sweep
M&L for taking down unserviceable wall mounting fan to store for repair all as specified and directed
M&L for fixing only wall mounted fan and connecting to socket all as specified and directed
M&L for rewinding of wall mounting fan with super enamel copper wire as per existing size/gauge to achieve the required RPM as per manufacturers design including proper heating varnishing and provision of insulating etc and testing complete all as specified and directed.
wall mounting fan of size 400mm sweep
wall mounting fan of size 450mm sweep
S & F in repair of exhaust fan blade metal body suitable for 450 mm. all as specified and directed.
S & F in repair of exhaust fan blade metal body suitable for 300 to 380mm. all as specified and directed.
S&F in repair of ceiling fan blade for 1200mm sweep metal body all as specified and directed.
S&F in repair of ceiling fan blade for 1400mm sweep all as specified and directed.
S&F in repair of fan blade for wall mounting fan 400/450mm acrylic body all as specified and directed.
M&L for spary painting of ceiling fan complete in situ after necessary preparation of surfaces of ceiling fans of any size make complete and painting with one coat of synthetic enamel paint including filling cavities with filler after cleaning all dust etc and rewriting of MES Number etc complete all as specified and directed.
M & L for detecting faults at site of ceing fan,exhaust fan,wall mounting fan any type and make in CHAF area under AGE EM CHAF and rectifiying the defects and make functional including replacing of unserviceable defective electrical/spares accessories Note :- (i) Rate for any item shall be measured and paid under respective item of schedule (ii) Essential material like, insulation tape,screws and all tools required for carrying out the works and instruments to the detect fault shall be deemed to be included in the quoted rate (iii) The work is of day to day maintenace, required Electricians and Helper has to be attend daily for carryout the above work. (iv) Non rctification of complaints penal charge of Rs 300/- per complaint shall be imposed.
Taking Down and Refixing incl Painting of water heaters (Geysers) of following capacity of any make/model in site with synthetic enamel paint by brush including filling of cavities with fillers one coat after cleaning all dust etc including writing MES numbers etc all as specified and directed following sizes:-
Water heater 25 litres capacity.
Water heater 50 litres capacity.
Dismantling following unserviceable items/parts from water heaters of any capacity/make/model, supply and fix inreplacement with new items/parts of same capacity/type/model, connecting up and testing :-
Supply & fixing in repair Heating element 1.5 KW capacity AC 230 V and conforming to IS specifications screw/flange type.
Supply & fixing in repair Heating element 2.0 KW capacity AC 230 V and conforming to IS specifications screw/flange type.
Supply & fixing in repair Thermostat suitable for water heater upto 80 litres capacity.
Supply & fixing in repair Non return valve 15 mm dia size.
Supply & fixing in repair PVC connection 15mm size with PTMT nuts of length 450 mm for hot water supply.
Supply & fixing in repair PVC connection 15mm size with PTMT nuts of length 600 mm for cold water supply.
Supply & fixing in repair PVC connection 15mm size with PTMT nuts of length 900 mm for cold water supply.
Supply & fixing in repair Rubber gasket flat/'O' ring type suitable for water heater
Supply & fixing in repair PVC insulated and FR PVC Round Sheathed, Copper Conductor(flexible) industrial cable, 1100 Volts 3 core flexible copper conductor cable of size 2.5 sqmm
Supply & fixing in repair Plug top 3 pin 15 amps all as directed..
Supply & fixing in repair Pressure release safety valve suitable for geysers upto 80 litres capacity. all as directed.
M&L in replacement old rusted /worn out MS bolts and nuts and grouting 4 nos new MS "T" bolts and nuts in brick walls ( MS bolt size 3/8 " x 6" with washers ) for fixing of Geyser and making good the disturbed surfaces incl plastering , curing etc all as directed.
M&L in replacement the Geysers from building and taking out the inner container(copper) and repairing the cracks by soldering /gas welding/Tinkering and reassembling the inner container, sealing the gap and refixing in same position of the building and testing
Supply and filling with compact packing of glass wool of suitable thickness for water heater of following capacity
Water heater 25 litres capacity.
Water heater 50 litres capacity.
Supply and fixing in reapir bottom assembly apparatus plate of copper for water heater of following capacity suitable to accommodate Thermostat, Heating Element as existing
Water heater 25 litres capacity.
Water heater 50 litres capacity.
Supply and fixing in repair outer body assembly complete with top and bottom for water heater of following capacity
Water heater 25 litres capacity.
Water heater 50 litres capacity.
S&F bib taps cast copper alloy with clutch or butterfly handle screwed for GI pipe 15mm dia chromium plated fency type.
S&F in repair Stopcock cromium plated screwed down High pressure with crutch or butterfly handle screwed both ends for iron pipe or for union completebib taps cast copper alloy with clutch or butterfly handle screwed for GI pipe 15mm dia complete
M & L for detecting faults at site geysers any type and make in CHAF area under AGE EM CHAF and rectifiying the defects and make it functional including replacing of unserviceable defective electrical/spares accessories Note :- (i) Rate for any item shall be measured and paid under respective item of schedule (ii) Essential material like, insulation tape,screws and all tools required for carrying out the works and instruments to the detect fault shall be deemed to be included in the quoted rate (iii) The work is of day to day maintenace, required Electricians and Helper has to be attend daily for carryout the above work. (iv) Non rectification of complaints penal charges of Rs300/- per complaint shall be imposed.
Supply and fixing in repair of Single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole 20A MCB ,C curve , 10KA as all as directed.
M&L for descaling of geyser any capacity including inner container and bottom apparatus using rod, brush and soda lime and made serviceable complete all as specified and directed
Supply and fixing of Ceiling Fan down rod of 450 mm length including fixing with fan Clamp all as specified and as directed
Supply and fixing of Ceiling Fan down rod of 600 mm length including fixing with fan Clamp all as specified and as directed
Supply and fixing of Ceiling Fan down rod of 900 mm length including fixing with fan Clamp all as specified and as directed
RAMSON TRADERS
UNIVERSAL ENGINEERING
mahadevi Enterprises
GKR and CO
Jagdamba Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .