Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | Admitted-Finance |
| 2 | Admitted-Finance 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | Admitted-Finance |
| 3 | Rejected-Technical C O SH JITENDER CHAUHAN 542 L MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | PANIPAT | HARYANA | 132103 | Rejected-Technical rejected |
Tender Value
₹79.3 L
EMD Value
₹1.6 L
Closing Date
2 Nov 2023, 5:00 pmClosed
VISHWNATH KHICHI
ED - Rohtak
The Govt. of Haryana has approved a scheme for pdg. Fire Alarm system in old Civil Hospital Bahadurgarh in distt. Jhajjar. The work stands administratively approved amounting to Rs. 130.18 lacs only the Additional Chief Secretary to Government Haryan
2023_HRY_319920_1
2023E91E683B F363 4EFA 8246 3B207BA078E0667BAR
Open Tender
Electrical Works
Works
120 days
Bahadurgarh
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹5,000
₹1.6 L
Yes
20 Dec 2023
12 Oct 2023
3 Nov 2023
12 Oct 2023
2 Nov 2023
12 Oct 2023
Amount
HSR Items
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
NS Items
Supply and erection of PVC Insulated and FRLS Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Flexible Cables for Voltage Grade 1100 Volts conforming to IS: 694:2010 complete in all respect upto the entire satisfaction of Engineer in charge of the work i) 2 core PVC unsheathed copper size 1.5 sq mm
Supply, installation, testing and commissioning of 17 U Standard rack to place all Av equipment Make Valrack, Comrack,Hive Networks.
SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make PES/Glolite/OMEX
SITC of minimum 1000 Mtr. Range Siren generator provided at the roof of the building with separate power supply, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer Incharge. Make: National/Kheraj
SITC of ``22 U Standard rack` to place all Av equipment and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. Make Valrack, Comrack, Hive Networks (HN)
SITC of Battery Backup for Controllers (5 KVA UPS on line with 1 hours backup ) and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. Make: ETON / APC / LIBERT / EMERSON / Microtek
Supply Installation Testing and commissioning of `Celling Mount Speaker` with Plastic Mount or without mount as per site requirement for operation 6 Watts Make Honeywell/ Henrich / bosch.
Supply erection testing and commissioning of `Cabinet Speaker Max Power - 9 W`, Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz, Opening angle (at 1 kHz/4 kHz, - 6 dB), In degrees - 150/70,Rated voltage - 100 V, Rated impedance - 1667 Make: Henrich / Honeywell / BOSCH
SITC of `Horn Loudspeaker 15 watts` . Max power 22.5 W, Rated power (PHC) 15 W ( 15,7.5,3.75 W), Sound pressure Level rated power 103dB ( At 1kHz,Iw,Im), Effective frequency range (-10dB) 500Hz to 5KHz ,Opening angle (at 1 kHz/4kHz,-6 dB), Rated voltage 100 V . Rated impedance 667ohm. Ambient temperature range -25 to plus 55 C .Connection 4 wire cable, 50 cm long complete in all respect Make: Henrich / Honeywell / Bosch.
SITC of Booster amplifier `480 watts Frequency` response: 60 Hz to 15 khz ( plus 1/3db), Inputs :XLR and phone jack , Input 1, Input 24, Impendence :20kG, Sensitivity : 1 V balanced , S/N ): )85 dB complete in all respect Make: Henrich / Honeywell / Bosch/
SITC of addressable multi sensor detector with a combination of Optical and Thermal including mounting base, auto addressing feature as required. Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) `Makes: Siemens Cerberus / Notifier/ Bosch.
SITC of UL/EN54/LPCB listed and FM Approved Line Isolator for Isolating the section of circuit in case of short in the addressable Loop wiring Make: Siemens Cerberus / Notifier/ Bosch.
SITC of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make: Siemens Cerberus / Notifier/ Bosch.
SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make: Siemens Cerberus / Notifier/ Bosch.
SITC of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Makes: Siemens Cerberus / Notifier/ Bosch
SITC of Addressable Loop powered sounder with strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Makes: Siemens Cerberus / Notifier/ Bosch.
SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully complaint to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Makes: Siemens Cerberus / Notifier/ Bosch.
SITC of addressable Heat detector with fixed and rate of raise feature including mounting base with LED etc. complete as required. Each Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Makes: Siemens Cerberus / Notifier/ Bosch.
Supply, Installation, Testing and Commissioning of Micro processor based 2 wire fault tolerant, networkable type fire alarm / detection control panel ( having nos. of loops to suit minimum 20% extra over the nos. of below mentioned fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character L C D unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80LED Indicators. The Panel shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work Makes : Notifier NFS 3030 / Cerberus PRO by Siemens / Bosch.
Insat Techno Services
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .