Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC 96 1 HIMMATGANJ BEHIND UNANI MEDICAL COLLEGE PRAYAGRAJ 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹9.6 L+₹61,986 (6.89%)Rejected-Finance 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹9.7 L+₹70,082 (7.79%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹10.1 L+₹1.1 L (12.0%)Rejected-Finance 26M NEEM SARAI DHOOMANGANJ PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹10.1 L+₹1.1 L (12.7%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST |
| Sl No | Description | Qty | Unit | M/S AM ENTERPRISES L3 | bharat construction L4 | M/S vibhuti enterprises L2 | AMRESH TRADERS L6 | swastik builders L8 | Krishna Enterprises L7 | M/S SHIV BALLABH MISHRA L1 | PITAMBARI TRADERS L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for repair/overhauling of existing APFC panel 50 KVAR TO 75 KVAR capacity/rating including cleaning with compressed air, tightening of all electric connections, replacement of wornout/ unserviceable cable of suitable capacity/rating with suppy & replacement of lugs, re-fixing of panel door with proper fixing/locking arrangement, glands to be provided as required at cable entries including any work not included above but considered necessary for efficient performance of APFC panel and testing on completion complete all as specified and as directed by Engr-in-charge.
Note: contractor shall visite the site before quoting their rates. Quoted rate shall be deemed to include the rate required for neccessary material etc. | 5 | Each Job | 3,500 ₹17,500 | 3,700 ₹18,500 | 3,600 ₹18,000 | 3,650 ₹18,250 | 4,000 ₹20,000 | 3,100 ₹15,500 Lowest | 3,200 ₹16,000 | 3,500 ₹17,500 |
| 2.00 | M&L for repair/overhauling of existing APFC panel 125 KVAR capacity/rating including cleaning with compressed air, tightening of all electric connections, replacement of wornout/ unserviceable cable of suitable capacity/rating with suppy & replacement of lugs, re-fixing of panel door with proper fixing/locking arrangement, glands to be provided as required at cable entries including any work not included above but considered necessary for efficient performance of APFC panel and testing on completion complete all as specified and as directed by Engr-in-charge.
Note: contractor shall visite the site before quoting their rates. Quoted rate shall be deemed to include the rate required for neccessary material etc. | 1 | Each Job | 4,200 ₹4,200 | 4,300 ₹4,300 | 4,200 ₹4,200 | 3,800 ₹3,800 | 4,000 ₹4,000 | 4,200 ₹4,200 | 3,700 ₹3,700 Lowest | 4,295 ₹4,295 |
| 3.00 | Supply , Installation, testing and commissioning of in replacement of Power factor improvement panel of capacity 75 KVAR size 1100 mm x 700 mm x 250 mm, fully type test according to IEC 61439-1&2,IEC 61921 including interconnection with LT panel with appropriate size of electric cable for Main panel factory made, weather proof , dust and vermin proof (IP 65) suitable for Humidity: up to 95%,Average daily temperature: +35°C max,Ambient temperature: -5°C to 45°C, 1100 V/660 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG MS sheet welded on 40 x 40 x 3 mm angle iron frame / base of appropriate size and having four Nos angle iron legs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all as specified and directed by Engr-in-Charge and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copper NYVIN cable of suitable size and PVC flexible conduit medium quality as required , comprising of the following:-
(A) Insulated Bus bar of aluminium of 250 Amps capacity for three phase, fixed on insulators, Busbar should be PVC sleeved with Red, Yellow & Blue Colour, Bus bar support should be of SMC/DMC, Rated Impulse Withstand Voltage 8KV -01 Set | 1 | Each | 1,80,000 ₹1,80,000 | 1,80,000 ₹1,80,000 | 1,78,000 ₹1,78,000 | 1,70,000 ₹1,70,000 | 18,000 ₹18,000 Lowest | 1,75,000 ₹1,75,000 | 1,97,000 ₹1,97,000 | 1,60,000 ₹1,60,000 |
| 3.01( B) Incommer MCCB 160 Amp , four pole, short circuit breaking capacity 36 KA Icu at 415 V (KA rms), Ics =100% , IEC 60947-2 Adjustable thermal and fixed magnetic setting ,frame LS type, Front Face, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.Make:- Schneider/ Siemens / ABB/L&T/Havells -1 No. (C) Capacitor 75 KVAR (2 KVAR x 01 No, 3 KVAR x 01 No, 5 KVAR x 02 Nos, 10 KVAR x 02 Nos, 20 KVAR x 02 Nos) , square type capacitor heavy duty rated, capacitor bank of rated 440 volt , 3 phase, Maximum over current: 1.8 In,Overpressure protection,Discharge resistance 50 V - 1 min, Capacitance Tolerance -5%, +10%,Maximum permissible over current(with thermal protection included)1.43 In ,Maximum permissible over voltage 1.1 x Un, 8 h every 24 h,of rated 480 volt with detuned Reactor of de-tuning factor (P) 7% and suitable output of 75 KVAr at 440 volt suitable output , Overheating protection by thermostat confirming to IS-13340-1993/, 13341-1992 & IEC -60831-1+2. .Make:- Schneider/ Siemens / ABB/L&T/Havells (D) Intelligent Power factor controller relay 8 steps, seven segment LED Display, Augiliary power factor, Algotitham, Dual password protection 4 digit display, Alarm Indication on Display switching time programmable 1 s to 1809 s, 90V - 550V 50/60Hz 1A/5A with RS485 Make:- Schneider/ Siemens / ABB/L&T/Havells -01 No (E) SP MCB ,C-Curve, 240 volt, 10 KA, Control Circuit, .Make:- Schneider/ Siemens / ABB/L&T/Havells | |||||||||||
| 3.02(F) CT 250/5A , 10 V.A,CL:1.0,Resin Cast , CT Secondary wire Size should be 2.5 Sq mm.Make : Kalpa /AE/ L&T/Kappa -03 Nos (G) Accessories for 75 KVAR capacitor Bank :- (1) Capacitor Duty Contactor (3 KVAR x 02 Nos, 5 KVAR x 02 Nos, 12.5 KVAR x 02 Nos, 25 KVAR x 02 Nos ) 440 volt with damping resistors which limit inrush Current,440 volt ,3ph,50 Hz, Coil-220 Vac, .Make:- Schneider/ Siemens / ABB/L&T/Havells (2) MCB, TPN, 10 Amp, 10 KA, 240 Volt, Make : Siemens/ ABB / Schneider /L&T/Havells -04 Nos (3) MCB, TPN, 16 to 25 Amp, 10 KA, 240 Volt, Make : Siemens/ ABB /Schneider /L&T/Havells -04 Nos (4) Digital Voltmeter of size 96x96mm (0-500V) with built in selector switch. (5) Digital Ammeter of size 96x96mm (0-400A) with built in selector switch. (6) Indication lamp 22.5mm dia LED type 240volts AC to show three phase availability-01Set. (H) Ventilating fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switching ON and OFF of fans depending upon the temperature of the Panel. 230 V AC, 2650 rpm,160 Cu.m/h, Flying leads - 04 Nos (J) All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to with stand high temperature, housed in cubical panel (CPRI approved) made out of 3.15 mm thick MS sheet factory made as per IEC 62208 duly powder coated front and rear door open able with locking arrangement complete with,IK 10 protection against mechanical Shocks as per IEC 62262 foundation as required or recommended by manufacturer. Make of APFC Panel: Note: APFC Panel shall be manufactured by original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf and the panels so manufactured will not be accepted. | |||||||||||
| 4.00 | Supply & fixing capacitor heavy 25 KVAR, cylindrical type, rated voltage 440 Vac, 3 phase, delta connection of Make : L&T / Schneider/Havells/ legrand/GE/L&T including single PVC sheathed copper conductor cable of suitable size, thimble, nuts, bolts, washers etc complete including taking down of unserviceable Capacitor complete all as specified and directed. | 5 | Each | 5,600 ₹28,000 | 5,700 ₹28,500 | 5,500 ₹27,500 | 5,800 ₹29,000 | 5,500 ₹27,500 | 6,000 ₹30,000 | 4,850 ₹24,250 Lowest | 5,650 ₹28,250 |
| 5.00 | Supply & fixing capacitor heavy 15 KVAR, cylindrical type, rated voltage 440 Vac, 3 phase, delta connection of Make : L&T / Schneider/Havells/ legrand/GE/L&T including single PVC sheathed copper conductor cable of suitable size, thimble, nuts, bolts, washers etc complete including taking down of unserviceable Capacitor complete all as specified and directed. | 3 | Each | 2,900 ₹8,700 | 2,900 ₹8,700 | 2,800 ₹8,400 Lowest | 3,200 ₹9,600 | 3,500 ₹10,500 | 3,100 ₹9,300 | 2,830 ₹8,490 | 3,140 ₹9,420 |
| 6.00 | Supply & fixing capacitor heavy 10 KVAR, cylindrical type, rated voltage 440 Vac, 3 phase, delta connection of Make : L&T / Schneider/Havells/ legrand/GE/L&T including single PVC sheathed copper conductor cable of suitable size, thimble, nuts, bolts, washers etc complete including taking down of unserviceable Capacitor complete all as specified and directed. | 6 | Each | 2,100 ₹12,600 | 2,200 ₹13,200 | 2,050 ₹12,300 | 1,800 ₹10,800 Lowest | 2,200 ₹13,200 | 2,250 ₹13,500 | 2,210 ₹13,260 | 2,060 ₹12,360 |
| 7.00 | Supply & fixing capacitor heavy 7.50 KVAR, cylindrical type, rated voltage 440 Vac, 3 phase, delta connection of Make : L&T / Schneider/Havells/ legrand/GE/L&T including single PVC sheathed copper conductor cable of suitable size, thimble, nuts, bolts, washers etc complete including taking down of unserviceable Capacitor complete all as specified and directed. | 8 | Each | 1,550 ₹12,400 | 1,600 ₹12,800 | 1,530 ₹12,240 | 1,740 ₹13,920 | 2,000 ₹16,000 | 1,770 ₹14,160 | 1,415 ₹11,320 Lowest | 1,720 ₹13,760 |
| 8.00 | Supply & fixing capacitor heavy 5.00 KVAR, cylindrical type, rated voltage 440 Vac, 3 phase, delta connection of Make : L&T / Schneider/Havells/ legrand/GE/L&T including single PVC sheathed copper conductor cable of suitable size, thimble, nuts, bolts, washers etc complete including taking down of unserviceable Capacitor complete all as specified and directed. | 8 | Each | 1,150 ₹9,200 | 1,200 ₹9,600 | 1,140 ₹9,120 | 1,350 ₹10,800 | 1,450 ₹11,600 | 1,300 ₹10,400 | 1,025 ₹8,200 Lowest | 1,340 ₹10,720 |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
20 Oct 2025, 6:00 pmClosed
AGE (I) AF MANAURI
AGE (I) AF MANAURI PRAYAGRAJ - 212212
REPAIR MAINT OF APFC PANEL AND CONNECTED ITEM IN VARIOUS LOCATION PAINTING OF POLES AND PANELS AT 24 ED UNDER AGE (I) MANAURI
2025_MES_733111_1
9270/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
MANAURI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE (I) AF MANAURI
₹18,000
Yes
19 Nov 2025
29 Sept 2025
22 Oct 2025
29 Sept 2025
20 Oct 2025
13 Oct 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
PS.pdf
Tender Documents • 0.32 MB
TENDER9270.pdf
Tender Documents • 0.63 MB
BOQ_820841.xls
BOQ • 0.33 MB
Makes.pdf
Tender Documents • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .