Clause Regarding GST: (a) All the Bidders/tenderers should ensure that they are GST Compliant and their quoted tax Structure are as per GST LAW.(b) Tenderer Should Furnish their GSTIN numbers representing the States in Which they are registered GST, along with address of Registered Office.(c)The Contract is under GST Act and rules as applicable time to time.
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Annual Contractual Turnover Data for the Previous 3/4 Years should be submitted as per Annexure-IX.(Annexure- VIB of Tender Documents)
39 conditions · 11 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Redevelopment of Station Building at DBRT Station Over TSK Division.
LV-T-14-TSK-935~NFR
LV-T-14-TSK-935
Open
Works - General
12 Months
Tinsukia, Assam
₹0
₹1.8 L
2 Mar 2026
6 Feb 2026
16 Feb 2026
142 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 47,30,589 | ||
| — | 300.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 95 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024 | — | — | — | 5,17,200 | |
| — | 300.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 70 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024 | — | — | — | 4,17,300 | |
| — | 200.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 25 mm.sq. 4 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024 | — | — | — | 1,32,800 | |
| — | 2000.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable size 16 mm.sq. 2 core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024 | — | — | — | 8,54,000 | |
| — | 24.00 | — | — | ||
| a) Supply and erection of Single Arm type Hot Dip Galvanized in single deep to average 65 micron DFT 5 mtr. long octagonal pole with sectional dia 130x70 mm, overall sectional thickness 3 mm complete with base plate size 200x200x12 mm, 4 Nos. 600 mm long foundation bolt of 16 mm dia with all other accessories as per direction of Engineer in charge at site. b) Supply and erection of PCC/RCC/shallow foundation 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) M15 Grade of size and depth as per recommendation and drawing of the manufacturer (approx. 1.6 mtr.x 0.6 mtr.x0.6 mtr.) with excavation of earth for foundation of all depth and all places, nature and condition of soil including de-watering, shoring, shuttering, batching, mixing, placing, leveling, carrying etc and re-filling the pit after completion of foundation work from excavated earth or borrowed pit by contractor's own arrangement for octagonal poles. Drawing of foundation details, loading, sectional plan bar bonding schedule etc. should be submitted before execution to get the approval from Rly. competent authority. | — | — | — | 4,34,424 | |
| — | 3.00 | — | — | ||
| Supply, fitting, fixing of 200 Amps outdoor type cable junction box, angle frame mounted, dust & vermin proof, complete with rain cap, aluminium basbar of suitable size for TPN, 200 Amps, 415 V made out of 16 SWG CRCA sheet duly painted, Cable Junction Box Size: (lxbxh=450x 450x600 mm). The base of the fedder pillar junction box to be provided with CC foundation of propotion 1:1.5:3( cement, sang,Chips) after connection of Ug cables. | — | — | — | 26,817 | |
| — | 170.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring of light point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, GI box with suitable modules for fixing switches. | — | — | — | 1,11,180 | |
| — | 40.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring of Fan Point/Exhaust fan point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A,ceiling rose,Modular GI metal box with suitable modules for fixing switches & Regulators and 1.0 sq mm multistrand FRLS copper Cable in green for earth contuinity wire . | — | — | — | 37,800 | |
| — | 50.00 | — | — | ||
| Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type wiring 5 A plug point from main/sub-main board to the points by 1.5 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 6 A ,GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire. | — | — | — | 21,400 | |
| — | 30.00 | — | — | ||
| Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type wiring 15 A plug point from main/sub-main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 15 A , GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire. | — | — | — | 36,900 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring for AC point from main/sub-main board t o the points by 6 mm sq single core multi-strand FRLS copper cable through heavy duty PVC conduit pipe including MCB Protected Power Unit 25 A ,modular type having Socket, push Starter and 1.0 mm.sq. unsheathed copper cable in green colour for earth continuity wire. | — | — | — | 18,100 | |
| — | 720.00 | — | — | ||
| Supply, drawing and connection of single core 4 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site. | — | — | — | 40,824 | |
| — | 1050.00 | — | — | ||
| Supply, drawing and connection of single core 2.5 sq. mm PVC insulated & unsheathed multistrand FRLSH copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site. | — | — | — | 40,740 | |
| — | 1.00 | — | — | ||
| "Supply, fitting, fixing, testing, and commissioning of 6-Way SMDB, 250 A (Double Door type), suitable for indoor installation, complete with 4-pole MCCB incomer and 4-pole MCCB outgoing feeders, fabricated from CRCA sheet steel, powder-coated, and conforming to relevant IS/IEC standards. The SMDB shall consist of the following components: (i)Main SMDB Enclosure (Double Door Type) 6-way enclosure suitable for 250 A, 4-pole MCCB as incomer and 4-pole MCCBs as outgoing feeders, complete with mounting arrangements, removable gland plates, earthing terminals, and adequate cable entry provisions. (ii)SMDB Bottom Cable Unit (Double Door) - 1 No (iii)SMDB Cable Alley Unit, 250 A (Double Door Type) - 2 Nos (iv)Metering Unit (for Double Door SMDB only) Complete with Ammeter, Voltmeter with selector switch, and Phase Indicator lamps (3 Nos), including internal wiring and accessories. (v)SMDB Corner Units for Double Door - 4 Nos (vi)MCCB Incomer 250 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release, complete with mounting, interconnections, and protection accessories - 1 No. (vii)MCCB Outgoing Feeders 125 A, 4-Pole, 25 kA breaking capacity (Icu), BC type MCCB, with Ics = 100% of Icu and adjustable thermal-magnetic release, complete with mounting hardware and internal wiring - 6 Nos. The SMDB shall be provided with electrolytic grade copper busbars, adequately rated for the system current and fault level, supported on suitable insulating supports and color coded. Internal wiring shall be carried out using PVC insulated copper conductors with proper ferruling. The panel shall be provided with earthing arrangement, labeling, danger notices, and circuit identification, complete in all respects. Installation shall include alignment, leveling, tightening of all electrical connections, testing for insulation resistance and functional operation, and commissioning. The rate shall be inclusive of all materials, labour, tools, transportation, installation, testing, commissioning, and all incidental works, complete in all respects, as per specifications and directions of the Engineer-in-Charge." | — | — | — | 2,24,584 | |
| — | 2.00 | — | — | ||
| Supply, fitting, fixing of wall mounted VTPN DB, Vertical TP MCCB as incomer 4 way double door , IP: 43 Protection, Shrounded Neutral Bar and pan assembly with flexible connecting link., cement spill protector, door earthing with the following:(i) MCCB 100 Amps, 4 pole ,25KA BC= 1 No.(ii) MCB DP 63 Amps, C series, Icn =10KA BC= 2 Nos. (iii) MCB DP 32 Amps, C series, Icn =10KA BC= 4 Nos. | — | — | — | 63,936 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of 8 way Double Door SPN MCB DB with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i)MCB 16 A DP 'C' Series, 10KABC= 4 Nos | — | — | — | 61,050 | |
| — | 48.00 | — | — | ||
| Supply , fitting, fixing of LED streetlight 45 W made up of pressure die cast alluminium alloy housing(heat sink) with tempered protective toughned glass fixed to the housing with SS screws and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07, Operating voltage range: 140-270V ,Lumen efficacy of LED 100 lm/W with PC lens to ensure better uniformity of light distribution powered by integral, isolated electronic LED driver should be as per IEC: 62384/IS:16104(SMPS based constant current supply) with THD<20%, Output Open / Short Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection & other safety tests as per IS 15885 Part-2/ Sec 13. Power factor>=0.95 , color temperature=5700 K ,LED Should be as per LM-80/IS:16105 . For Octagonal Poles. | — | — | — | 2,26,560 | |
| — | 120.00 | — | — | ||
| Supply, fitting , fixing of Batten Intergated type LED fitting 20W, 4 Ft, ultra slim co- extruded polycarbonate channel with integrated electronic driver should be as per IEC: 62384/IS:16104( SMPS based constant current output, THD<20%), IP20 protection, color temperature=6500K, rated input voltage=230V AC, 50 Hz, power factor=0.9, view angle>=120°, lumens output not less than 100 lm/Watt, operating voltage range: 140-270 V AC. LED Should be as per LM-80/IS:16105. Fixture Size:(LXWxH=1156x25x35 mm +/-1) . | — | — | — | 30,120 | |
| — | 50.00 | — | — | ||
| Supply and fitting, fixing of 24 Watt LED Slim, compact, auminum die cast edge lit panel light, recess mounted square fixture with opal diffuser and separate electronic driver. | — | — | — | 77,650 | |
| — | 10.00 | — | — | ||
| Supply installation of Inverter Split Air Conditioner, 1.5 Ton, BEE 5 Star Rated of wall- mounted split type with inverter compressor technology, suitable for efficient cooling with low power consumption. The AC shall have a rated cooling capacity of 1.5 Ton (approximately 5.0-5.2 kW) and shall operate on 230 V AC, 50 Hz single phase power supply. The unit shall be BEE 5 Star rated as per latest BEE norms, with ISEER value not less than 4.6 (or as per current 5-Star classification), ensuring high energy efficiency. It shall be equipped with a high-efficiency rotary inverter compressor, using eco-friendly refrigerant (R-32 or equivalent), suitable for tropical climatic conditions. The indoor unit shall have a low-noise blower, uniform air distribution, washable air filters, and precise temperature control, while the outdoor unit shall be robust, weather-resistant and supplied with a heavy-duty galvanized steel / powder-coated mounting bracket for fixing the outdoor unit. The scope shall include supply and installation of required low-pressure (suction) and high-pressure (liquid) copper connecting pipes of suitable diameter and thickness, properly insulated, of required length as per site installation conditions, complete with flare nuts and fittings, ensuring leak-proof operation.The AC shall include standard safety and protection features such as overload protection, voltage fluctuation protection, and auto-restart. | — | — | — | 4,49,900 | |
| — | 10.00 | — | — | ||
| Supply, installation testing and commissioning Exhaust Fan 300 Mm sweep metallic Type, 230V AC, 50HZ. | — | — | — | 14,730 | |
| — | 30.00 | — | — | ||
| "Supply, installation testing and commissioning of 1400 mm BLDC motor, BEE 5 star rated ceiling fan With regulator enable motor with power of 26 watt with 10% tolerance , motor insulation B type 220-240V 50Hz single phase with Speed minimum 350 rpm minimum air delivery 225CMM complete set of 3 no's. blade , down rods, 2 nos canopies , shackle kit & all remaining accessories including nut bolts Washers complete as required ." | — | — | — | 91,140 | |
| — | 2.00 | — | — | ||
| Supply, installation of pure sine wave inverter 2.5KVA/2 KW , 24V DC with inbuilt LCD display, Protection: Short circuit, Overload, Over Temperature, Low Battery Alarm With Battery Bank Comprising of 2 Nos 150Ah Tall Tubular Lead ACid Battery.Warranty: Inverter: 24 Months, Battery: 36 Months | — | — | — | 1,27,580 | |
| — | 2.00 | — | — | ||
| Supply Installation of online UPS with rated capacity of 1 KVA suitable for continuous and critical power applications, operating on 230 V AC input with wide input voltage range of 110- 300 V AC at 50 Hz. The UPS shall provide regulated 230 V AC output with pure sine wave and zero transfer time, having output voltage regulation within ±1% and frequency stability of ±0.5%. The DC bus voltage shall be 36 V DC, designed to operate with an external battery bank comprising 3 x 12 V lead acid batteries (SMF or tubular). The UPS shall have built-in intelligent battery charger with adequate charging current, input power factor 0.95, output power factor 0.8, and AC-to-AC efficiency of minimum 85% at full load. It shall include comprehensive protections such as input over/under voltage, overload, short circuit, battery deep discharge, over-temperature, and surge protection. The unit shall be provided with LCD/LED display for input/output status, load, battery condition and fault indications, along with audible alarms. Cooling shall be by forced air with low-noise fan. Warranty: 24 Months The Supply of battery Bank 3x42Ah SMF battery is in the scope of work. | — | — | — | 85,598 | |
| — | 1.00 | — | — | ||
| Supply, installation testing and commissioning of Acrylic LED signage, Size: 10x4 Ft( 40 SQ FT) with 4 mm ACP sheet background. The Frame of the Signage board to be fabricated using 1.5 x1 inch , MS square pipe 16 gauge. The Letters to be engraved with be 40mm Acrylic letters. The Power Supply unit will be separate Replaceable Electronic Driver 230VAC/12VDC , 5 Amps to be suitable fixed outside the LED Signage Board.The Signage Board Should have IP65 Degree of Protection . The caption of the LED Signage Board will be trilingual: English, Hindi , Assamese with and caption will be provided by Railways as per requirement for installation . | — | — | — | 1,20,360 | |
| — | 10.00 | — | — | ||
| Supply, installation, fitting, fixing, testing and commissioning of Clip On dual face LED Signage Board of size 24"x18" in Tri-Lingual ( English,Hindi and Assamese) as per direction of Supervisor In-charge at site The Signage Board to be made using 2 Nos. of 8 mm thickness clear Acrylic sheet and Film pest as per the signage design through computerized laser letter and sandwiched with desired color acrylic sheet of 1 mm size in between for creating the base colour (Blue,yellow ,red etc. ). The single face edge light sign board to be made using one no of 8 mm thickness clear Acrylic sheet and engraved as per the sign design through computerized laser and joind with desired colour 1 mm size in between for creating the base colour (Blue, Yellow etc.)of matching colour (Black, White etc.) . The above acrylic section will be fitted into a modular extruded dove toil Standard steel 340 grade quality side as per the dimension given. The two sides and bottom of the above fabricated acrylic section will be covered with suitable size / shape standard aluminium extruded section. The LED system will be placed in the frame inside section . The Power Supply unit will be separate Replaceable Electronic Driver 230VAC/12VDC , 2 Amps to be suitable fixed outside the LED Clip on Signage Board. The LED module have 2 nos. hi-flux SMD cool White colour LEDs ( colour temparature : 6500 K). The module will be connected to parallel mode. The LED system will consist of minimum LEDs in modules for uniform illumination of the edge lit signage face and will have minimum lumen output of 24 lumens per module with power consumption of not mor than 0.60 watt per module including the power supply. The LED system will have operating temperature range of -40 deg. C. to + 60 deg. C . The Signage Board Should have IP65 Degree of Protection .Letter in word a. English b. Hindi c. Assamaese. Also symbolic arrangement should be made within the signage. | — | — | — | 60,180 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing, and commissioning of All-in-One Solar Street Light, 20 W, complete with in-built mono-crystalline solar panel, LiFePO battery, MPPT charge controller, minimum 2 days autonomy, and pre-programmed dimming profile, suitable for outdoor street lighting applications, with automatic dusk-to-dawn operation and protection against over-charge, over-discharge, short-circuit, and reverse polarity, housed in a weather-proof, corrosion-resistant enclosure of minimum IP65 protection, complete with supply and installation of powder-coated tubular steel pole as per manufacturers recomendations, excavation, PCC/RCC foundation, grouting, alignment, curing, fixing of the luminaire on pole with proper orientation for maximum solar exposure, testing of charging, battery backup, dimming function, and commissioning of the complete system, inclusive of all materials, labour, tools, transportation, erection, and incidental works, complete in all respects as per specifications and directions of the Engineer-in-Charge. | — | — | — | 2,60,000 | |
| — | 1.00 | — | — | ||
| Supply,fitting & fixing of 200Amps 4-Pole Changeover switch Conforms to IS/IEC 60947-3,415 Volt,50Hz with door interlock and steel encloser sheet for signalling equipment | — | — | — | 24,310 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of Water cooler storage capacity 80 Ltrs with inbuilt UV and RO water Purifier, cooling capacity : 60 ltrs/hr with Stainless Steel Body. Specification of water cooler: (i) Cooling capacity Ltrs/Hour=60 (ii) Storage capacity=80 Ltrs (iii) No of water Taps= 2 No(iv) Refrigerant: R-134A/R22 (v) Compressor: Hermatically Sealed with suction gas cooled motor equipped with overload protection.(vi) Condenser Fan: Propeller Type (vii) Thermostats: Automatically controls temperature,(viii) Power Supply: 230 V AC+/- 10% , 50 Hz, Single phase, (ix) Water Supply: 3 M to 12 M head(x) Power Supply: 15 Amps , 3 pin plug with proper earth connection. | — | — | — | 69,990 | |
| — | 4.00 | — | — | ||
| Supply, fitting, fixing of Wiring materials for Geyser point wiring from DB/ sub main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 16 A , 3 Module Plate, GI metal flush box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire. . One 16 Amps DP MCB 'B' series in MCB enclosure to be provided near Geyser as controlling switch. | — | — | — | 5,164 | |
| — | 4.00 | — | — | ||
| Supply, fitting, fixing , testing & commissioning of Geyser( storage type water heater), 5 star rated, capacity 25 Ltrs, with external knob for adjustment of temperature, feroglass coating inner tank, shock resistant plug, high density PUF insulation, water resistant and splash proof body with 2 years comprehensive warranty( 4 years warranty on heating element and 7 years warranty on inner tank). | — | — | — | 48,252 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .