Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹9.6 L+₹2.6 L (37.0%)Rejected-Finance | L2 | Rejected-Finance Being L2 |
Tender Value
₹10.9 L
EMD Value
₹22,000
Closing Date
14 Nov 2023, 5:00 pmClosed
General Manager Procurement and Contract
Procurement and Contracts Division Salal Power Station Jyotipuram UT of J and K
Modernization/alteration of HOP office and creation of Visitor room along with HOP Sectt. at Administrative Building-II of Salal Power Station
2023_NHPC_771138_1
NH/SPS/CD/NIT09/23-24/393-402
Open Tender
Civil Works - Others
Item Rate
60 days
Salal Power Station Jyotipuram
Please refer Tender documents.
8 documents required · 8 mandatory
₹590
NHPC LIMITED
₹22,000
15 Jan 2024
12 Sept 2023
20 Nov 2023
12 Sept 2023
14 Nov 2023
12 Sept 2023
Amount
CIVIL WORKS
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: 15.7.4 In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead: 15.12.1 Of area of 3 sqm. and below
Dismantling aluminum / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : 6.15.2 Cement mortar 1:4 ( 1 cement : 4 coarse sand)
CEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix: 13.1.2 1 : 6 ( 1 cement : 6 fine sand)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing PVC wall panelling heavy duty along with fixing in position and other infrastructure complete in all respect
Providing and fixing PVC false ceiling heavy duty complete other infrastructure complete in all respect
Providing and fixing Wooden flooring heavy duty complete other infrastructure complete in all respect
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) 22.1.1 For fixed portion Powder coated aluminium (minimum thickness of powder coated 50 microns)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)22.1.2 For shutters of doors, windows & ventilators icluding providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) Powder coated aluminium (minimum thickness of powder coated 50 microns)
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding holdfasts in cement concrete blocks of size 15x10x10cm with cement concrete 1:3:6 (1 cement :3 coarse sand: 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground within 50 meters lead: 14.2.1 Door chowkhats
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) 22.3.2 With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm) 22.3.3 With float glass panes of 8 mm thickness (weight not less than 20.0 kg / sqm)
Electrical Works
Supplying and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63A rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring along with earth wire with the 2 x 10 Sq mm + 1 x 6 Sq mm earth wire of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for circuit/ submain wiring along with earth wire with the 2 x 4 Sq mm + 1 x 4 Sq mm earth wire of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for circuit/ submain wiring along with earth wire with the 2 x 2.5 Sq mm + 1 x 2.5 Sq mm earth wire of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supply Installation & commissioning of pre-wired, LED Tube Light fitting 18/20 Watt, complete with all accessories and tube etc directly on celing/wall including connection with 1.5 Sq mm FRLS PVC insulated copper conductor, single core cable and earthing etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing Modular Stepped type electronic Fan Regulator including connection etc. as required.
Supply Installation, testing and commissioning of squre 1.5X1.5' ceiling LED white pannel light 30 watt in existing fall ceiling with complete connection.
Door status indicator light - for HOP Chamber.
Balwan singh
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .