Loading…
Loading…
Tender Value
₹53.6 Cr
EMD Value
₹63.6 L
Closing Date
27 Jun 2026, 3:00 pm
DGM BSBCCL MUZAFFARPUR
DEPUTY GENERAL MANAGER MUZAFFARPUR
BSBCCL, Hospital Road, Sastri Nagar, Patna 800023
ANIL KUMAR
CGM
Rajkiya Ambedkar Residential Girls High school (Cap-720) at Sheohar.
132868
08/BSBCCL/2026-27 GR 01
Open Tender
CIVIL
Muzaffarpur
• (1) Audit report of last five years duly audited by C.A
• (2) Attached Banker' certificate on and after Date of tender publish.
• (3) Attached as per sec 2- 1.4(b) bidders must declare themselvess their all existing commitment hiding fact be sufficient causefor rejection.(Form C1 & C).
• (4) Bidding Capacity = (AxNx3-B) should be equal to or more than the cost of the work and where N=Time of completion of the project.
• (5) The contracting firm/agency shall be a well established and reputed firm specialised in the trade and registered as a legal entity for a minimum period of 10 years and having experience and capacity in the execution of similar works.
• (6) In case of joint venture analysis based on joint venture documents only should be submitted ( The documents will be submitted as per RCD letter no 8131 dt 24.7.12 related to J.V)
• (7) Contractor/ firms should have achieved during last five years i
n any one year a minimum Annual financial turn over (In all c
lasses of Civil Engineering Construction works only) at least
50% of the cost of work ,ending on 31st March 2026. The annual turn over of previous years will be adjusted to 2025--2026 price level based on annual inflation of 8% (eight percent).
• (8) The Contracting firm/ Agency Should have satisfactory completed as a prime contractor during last five years, ending (one month before date of tender).(Form B) As given below.
• (9) The Contracting firm/ Agency Should have satisfactory completed as a prime contractor during last five years, ending (one month before date of tender) Contractors/Firm's should have completed 3 - works costing not less than 40% of Estimated cost. OR, Contractors/Firm's should have completed 2 - works costing not less than 60% of Estimated cost. OR,Contractors/Firm's should have completed 1 - work costing not less than80% (Eighty Percent) of Estimated cost. The completion certificate shall be issued by employer not below the rank of Executive Engineer or project manager. In case of private client thecompletion certificate and Valuation of Project issued by employer should be certified by the Retired Engineer/ Registered Valuer of Nationalized Bank/Insurance Company/ Income TaxDepartment. The bidders shall have to also submit good quality digital photographs of the completed projects.
• (10) Similar nature of works means --- construction of Group Housing Buildings/ Township or Institutional buildings/ multistoried Buildings for State Govt. / Central Govt./ PSU Sector or any other nationally acclaimed organization in India only/Private Firm's or Individual Firm's.
• (11) The contracting Firm/Agency should have adequate capacity of carrying out plumbing works , fire fighting and electrical works [through "1A CLASS" Electrical Contractor].It is mandatory to attache valid registration & Experience Certificate.
They should also indicate name of the specialized Fire fighting agency.
• (12) Firm should have required experience only in any state of India.
• (13) The contracting firm /agengy should produce evidence of acce
sss to lines of credit and availability of other financial resource
facilities ( 10% of cost of work)
• (14) The bidders shall furnish under taking that he would be able to invest a minimum cash up to 25% of cost of work
• (15) Not abandoning work, not properly completing the contract ,
or financial failures/weaknesses etc.
• (16) NOC FOR DEBAR
• (17) Oath of follow labour Rule and Regulations as per Govt. norms.
• (18) Personal and Establishment.(Form E & E1)
• (19) PLANTS AND EQUIPMENT (Form F)
• (20) Pan,GST,Registration With Dept.,CHARACTER ISSUE BY District Magistrate.
• (21) IF SUB CONTACTROR MUST BE ATTACHED CHARACTER CERTIFICATE.Experience Certificate of identified Sub Contractor (Electrical/PHE) will be valid. Experience Certificate should be issued by at least Executive Engineer and equivalent officer. It is Mandatory to Attached Mutual Affidavit and Registration & Experience Certificate of Sub Contractor.
• (22) Solvency Certificate of Value not less than 40% of the estimated cost.certified by his Bankers after the Date of Tender.
CIVIL
PERCENTAGE
L1
1
22 documents required · 22 mandatory
₹10,000
Processing Fee: 5900
₹63.6 L
CGM,BSBCCL
3 Jun 2026
3 Jun 2026
30 Jun 2026
3 Jun 2026
27 Jun 2026
3 Jun 2026
12 Jun 2026
Earth work in excavation over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m ; disposed earth to be levelled and neatly dressed.
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
per 50 kg cement
Metre
TMTC-500- 8mm dia .
TMTC-500-10 mm dia.
TMTC-500-12 mm dia.
TMT FE-500-16 mm dia.
TMT FE-500-20 mm dia.
TMT FE-500-25 mm dia.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :
Cement mortar 1:6 (1 cement: 6 coarse sand ) - 250 mm th Brick work
Half brick Masonary Cement mortar 1.:4 (1 cement: 4 coarse sand ) - 125 mm th Brick work
Brick work with bricks of class designation 100A in foundation and plinth in :
cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with bricks of class designation 100A in foundations and plinth in :
Cement mortar 1:4 ( 1 cement: 4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia . M.S. bars at every third course of half brick masonry ( with FPS brick).
Extra tor Brick work in superstructure above plinth level upto floor V cum
Metre
Steel windows
Providing and fixing ISI marked steel wire gauged doors, windows and ventilators of standard rolled steel sections, joints mitered and welded with 15x3 mm lugs, 10 cm long , embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using galvanized M.S. wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm with 12 mm mild steel beading complete including applying a priming coat of approved steel primer, but excluding the cost of other fittings except necessary hinges or pivots as required
metre
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Metre
1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.
IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.
IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area.
IVth course of 400 micron thick PVC sheet (overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm
Providing plinth protection 750 mm wide consisting of 12 mm thick cement plaster 1;6 with neat cement punning over 75 mm thick P.C.C. (1:3 :6) over brick flat soling over 75 mm thick local sand filling all complete
Metre
Compacting original ground Compacting original ground supporting subgrade (Loosening of the ground upto a level of 500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of table 300-2 for subgrade construction)
Construction of subgrade and Earthen Shoulder (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)
Granular Sub-Base with Graded Material ( Table:- 400- 1) Plant Mix Method (Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.)
Rate per cum for grading-II Material
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Trees
Shrubs / Creeps
Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I.
Bricks (Lead - 1 km kutcha + 7 km pucca)
Coarse Sand (Lead- 171 km) from Koilwar
Stone Chips (Lead-244 km) from Manpur, Gaya
Stone Metal (Lead-244 km)
Local sand (1 km kutcha + 2 km pucca)
Earth (1 km kutcha + 2 km pucca)
Cement
Bricks
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
per litre
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge.
Providing, fixing, testing and commissioning of CP brass swan neck wall mounted sink mixer with wall flange and swinging casted spout complete as required and making good the walls wherever required.
Providing, Fixing air freshner on wall face with necessary rawl plugs and steel screws complete in all respects, including cutting and making good the wall wherever required.
Providing, Fixing satin finish stainless steel AISI 316 grade wall mounted coat hooks on door with CP brass wall brackets and CP brass screws complete in all respects, including cutting and making good the wall wherever required.
Providing, Fixing, testing and commissioning of adjustable type wash basin with elbow oprated tap for handicap toilet complete with brackets, tracks, waste pipes and other accessories complete including cutting and making good the walls wherever required.
Providing, Fixing, testing and commissioning of raised toilet seat with cover for handicap toilet including providing & fixing CP bolts, nuts, fisher/anchor bolt are required for hangong of WC complete with all accessories. Including cutting & making good the walls & floors wherever required.
Providing, Fixing, testing and commissioning of wall mounted 32 mm dia seamless stainless steel tube coated with nylon non-slip gripping surface hinged Hand Rail 750 x 100 mm complete in all respects, including cutting and making good the wall wherever required.
Providing, Fixing grab bar fabricated from 32 mm dia seamless stainless steel tube coated with nylon non-slip gripping surface 600 mm long grab bar in toilets for physically handicapped complete in all respects, including cutting and making good the wall wherever required. For Wash Basins & Water Closet.
Supply, Fixing, testing & commissioning of storage type stainless steel water cooler with inbuilt RO system, including angle valve and flexible connection piping of the following capacity. It shall have C.P brass push cock complete with inlet float valve (with angle valve) with all plumbing and electrical accessories, inlet, outlet, overflow and PVC drain out connection to F.D complete as required.
Metre
Metre
Metre
Metre
Metre
Metre
Providing and fixing, testing and commissioning of reducing floor drain of 110x63 mm OD as floor drain in cement concrete 1 : 2 : 4 float with floor complete in all respects.
Providing and fixing, testing and commissioning of uPVC multi angle inlet hight riser fittings with 3 or 4 side inlets of 40, 50 & 63 mm size and fixed to uPVC traps with drip seal/m-seal/solvent cement joint complete in all respect.
Providing and fixing cast brass Clean Out plug with suitable insert keys for opening, male threaded joint with G.I. socket lead caulked to soil pipe/waste pipe of C.I. and C.I.(LA) pipe as required complete
100mm dia
Providing, fixing, jointing and testing of uPVC pipes conforming to IS 4985 class III (6 kg/cm2) including injection moulded fittings with bosses like bends, tees, adoptors etc. suitable for rubber ring jointing complete including fixing to walls with clamps and hanging from ceiling to grade on adjustable supports.
40 mm dia
50 mm dia
63 mm dia
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
Metre
Metre
Metre
Metre
Metre
Metre
metre
metre
metre
metre
metre
20 mm nominal bore
Providing, fixing, testing & commissioning of vertical multistage centrifugal pumping set with stainless steel SS-304 stage casing and SS304 impellers with stainless steel SS304 shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440 volts, 3 phase, 50 Hz AC supply with pressure gauge and with gunmetal isolation cocks, vibration elimination pads etc. complete with base and frame, nuts and bolts and necessary RCC foundations as per requirement as per instructions and pump shall have following duty.
Pumps for Domestic Water Supply (Hydropneumatic)
Providing,fixing, testing & Commissioning of Sump Pumps for lifting water from drainage sumps in plant room
Complete piping 100mm dia common delivery upto 5m as per enclosed tentative layout. (The pipe should be preferably CI LA/heavy duty G.I) -- 1 Set
80mm dia butterfly valve.-- 2 Nos
80 mm dia NRV valve.-- 2 Nos
Necessary cables from pump set to control panel (position of panel marked in enclosed layout in plant room).-- 1 Set
Electrical switch panel having all necessary accessories & safety devices of standard specifications. (Panels with sump pumps near each sump as per site conditions). - 1 No.
Automatic built-up water level controller with necessary length of cable upto control panel.
Providing and fixing brass Single acting air valve PN 1.6 of approved quality with bolts, nuts, rubber insertion, tail pieces, tapers etc. if required as complete.
25 mm dia
Providing and fixing motorised butterfly valve with float type sensors suitable for 240 volts with working pressure rating of not less than 5 kg/cm2 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box etc., complete.
Metre
Metre
Metre
Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia
Pipes, cables etc exceeding 300 mm dia
Metre
Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
metre
Metre
metre
Metre
metre
Metre
metre
metre
metre
Supply fixing 2 HP Motor Pump (1 Unit) with 32 mm dia clamp (1 Unit), Suitable Length of cable, Panel Board & Starter (1 No.), centre Guide (6 Nos.) Machine Up and Down etc. all complete
Metre
Metre
Metre
Metre
Metre
Providing and fixing of weather proof standard HOSE CABINATE ( 0.6 M x 0.45 M x 0.3 M ) having central opening glazed door with 6 mm thick clear glass including necessary locking arrangement with Allan key, power coating with PO red paint and for housing 2 nos. RRL hose pipe, 1 No branch pipe. as reqd.
Providing & making drainage provision for the riser with 25 mm dia BALL VALVE completed as required
Supplying of XLPE/PVC insulated Sheathed (Heavy Duty) armoured electric cable with aluminium conductor of 1.1 KV graded con. IS 1554 Part I upto date amendment etc as required of following size
Power Cable 4 core x 16 mm2
3.5 core 35 sqmm
ABC Powder Type (Stored Pressure) Fire Extinguisher, 4 kg. Capacity, ISI mark (IS:15683), squeeze grip valve, operating temperature (+5) degree Celcuis to (+55) dgree Celcuis for Class 3A Type of Fire Filled with MAP ABC Powder, Complete in all respect
CO2 Type Fire Extinguisher, 4.5 Kg Capacity, ISI Mark (IS:15683) squeeze grip valve, operating temperature (-30) deg Cel to (55) deg cel. For Class 13B type of Fire Fitted with 1 Mt. Hose & PVC Horn, Complete in all respect.
Structure is made up of 40 mm dia CRC tube with thickness 18 gauge. Horizontal base is made from steel sheet the thickness 14 gauge. Horizontal base will be stiffened with appropriate longitudinal 3 v shape sheet and lateral stiffeners 2 steel pipes with powder coating. Manufactured out of ISO 9001, ISO14001 and OSHSAS 18001 certified Plant and product certified for BIFMA performance test (Size : 2000 x 900 x 650 mm (H)
Supplying and fixing of Mattress (size : 75"x36" x 2" thick) at site, with complete in all respect or as per direction of E/I
Dimension : DESK - 600 W x 480 D x 750 H SEAT - 868 H x 500 W x S 450 Finish/Coating : Powder Coating Material : MILD STEEL TUBULAR SECTION OVAL Tube 35 x 15 SQ. Tube 25x25 and PLB & Moulded wood Total Weight : 23Kg Available Base Frame : Knock down Features : >SEMI KNOCKDOWN > 11 TANK HOT ZINC PHOSPHATING PRE TREATMET PROCESS > Powder Coated
Size: Executive Desk Size - 1800mm (W) x 900mm (D) x 750mm (H) Side Unit - 1800mm (W) x 600mm (D) x 675mm (H) Combination of metal and wood reflects dynamism. Sleek floating top gives aesthetic and trendy look. Open rectanglular section legs with small modesty gives the table trendy, airy open look.
Size : 2.40 m x 1.05m x 750mm Providing & making meeting table of given size made of 35mm thick block board with 1.0mm thick laminate at top and 1-1/2" TW beading on all the sides with proper niche in between beading and laminate edge 25mm thick round laminated pedestal and wooden frame work 75 x 62mm T.W bracket as top support including polishing of wooden frame work and melamine finish all complete as per drawings.
Class room desk - 2 seater with pedestal storage unit (for Class room) & sitting Desk (size : 1050 x 450 x750 (H)) Supply,Fabrication & Installation of class room table top 19 mm thick prelimanated board with 2mm PVC edge banding , supported on MS square Hollow section (size : 40 mm x 40 mm) frame complete with wire manager at table top all fitting & assecories as per drawing & direction of E/I.
Seat/Back Assembly: The seat is made up of 1.2 ±0.1cm thick hot pressed plywood measured as per QA method described in OCP-QLTA- P14-18 and upholstered with fabric moulded Polyurethane Foam. The back is made up of 1.2 ±0.1cm hot pressed plywood upholstered with fabric moulded polyurethane foam. The back ply and foam is designed with contoured lumber support for comfortable seating posture. Mid Back Size - 48cm (W) x 64.5cm (H). Seat Size - 51cm (W) x 48cm (D) Armrest (Adjustable): The armrest top is made up of moulded polyurethane (P.U) and mounted on to a drop lift height adjustable type M.S. tubular armrest support chrome plated. The armrest height is adjustable up to 6.5±0.5cm in 5 steps & also has swivel adjustment of 22° ± 2° on both sides. Knee Tilt Synchro Mechanism with Seat Deapth Adjustment Mechanism: The mechanism is designed with the following features - 360° revolving type, Single point control, Front pivot for tilt with feet resting on ground ensuring more comfort, Tilt tension adjustment, 4-position locking with anti-shock feature, Seat back tilting ratio of 1:2 & Seat depth adjustment of 6.0 ± 0.5cm can be locked in 6 positions. Adjustable Backrest: The backrest consists of a sliding up down mechanism, which can be adjusted in the range of 7.5 ± 0.5cm and can be locked in 4 positions for correct position of lumber support. Pneumatic Height Adjustment: The pneumatic height adjustment has an adjustment of 9.0 ± 0.3cm. Pedestal Assembly: The pedestal is fabricated from 0.2 ± 0.2cm thick HR sheet (IS : DD 1079 / HR skin pass), chrome plated and assembled with injection moulded black polypropylene hub cap and 5 nos. twin wheel castors. The pedestal is 66.0±0.5cm Pitch-center dia. (76.0 ± 1.0cm with castors). Twin Wheel Castors: The twin wheel castors are injection moulded in black Nylon.
S/F ct site Godrej steel Multifux system of size 7' x 36 " x 18" with 7 nos. shalves of galvanised steel sheet with M.S steel angle frame of size 40x40x8 mm. Complete with supplying and fixing at site with including painting etc. as per direction of E/I
Table for class room/office (size : 1200 x 900 x 750) Supply, Fabrication & Installation of table made of Powder coated MS frame with 18mm thick prelaminated board top complete in all respect with wire manager lockable drawers etc. all complete as per drawing and direction of E/I
Work Surface: 25mm Thick (±1mm) Base Material - 25mm MDF Board on top PU painting of Minium 2H hardness with 75% glass as per color chart, combination color graphics on the centre. Color as per color chart. Brown laminate on bottom. Specially profiled edge for comfort. Understructure: Bend pipe understructure of MS. Powder Coated. Pipe dia. 38mm, 2mm thk. Understructure fitted with top by SS machine screws. Legs: MS Powder coated legs for PU top & SS legs for membrane top. 38mm dia pipe legs are fixed with understurcture and table top. Glide: Plastic Glide fixed at the understructure to prevent the damage of table top druing stacking. Size: Ground Base - 2450mm (L) x 1175mm (W). Surface Top - 2400.8mm (L) x 1050.4mm (W) & Height - 750mm (H)
Seat/Back: Seat & Back are injection moulded in PP. They are snap fitted on the understructure assembly and fixed with self-taping screws Approx. Back Size : 37.0cm (W) x 25.5cm (H) Approx. Seat Size : 40.5cm (W) x 40.5cm (D) Understructure Assembly: The understructure assembly is a welded frame assy. with the upper frame made of dia. Ø 1.9±0.02cm x 0.2±0.016 thk. and legs made of Ø 1.9±0.02cm x 0.16±0.0128cm thk. M.S. E.R.W tubes and black powder coated (DFT 40-60 microns)
Size : Depth (D) - 57.0 cm Width (W) - 58.0 cm Height (H) - 88.0 cm Seat Height (SH) - 47.5 cm The seat & Back are made up of Cushion covered with rexine. Behind all this is a robust tubular framework that makes the chairs durable.
Providing and fixing in position magnatic white board on walls including teak wood edge moulding. Complete with all necessery hardware, polish etc as per direction of E/I Size : 8' x 4'
3 sector chair (Chrome) Made of Cushion with high density cold cured self -skinned pre -molded foam of 50-60 density the shape of plywood. Upholstery is done by using high-pressure pneumatic spray glue and pneumatic press over crome base & legs etc. all complete as per direction of E/I
Computer Table - (size : 900 x 600 x 905 mm) computer Lab Supply and installation of Prelaminated particle board of wood finish on both side and top on hard wood frame with drawer, Cabinet and wire manager complete with all necessary hardware and as per drawing design and direction of E/I.
Computer Chair : Supply and installation of Telemate medium back chair with single point lock tilting mechanism castor and latherlite sheet over PU foam sheet complete on crome base
Point
Point
Point
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
meter
meter
8 way , Double door
NORMAL PANEL-SCHOOL
40 A to 63 A rating, Four pole MCB, "C" curve, 10 KA breaking capacity
DG PANEL-SCHOOL BUILDING
40 A to 63 A rating, Four pole MCB, "C" curve, 10 KA breaking capacity
40 A to 63 A rating, Four pole MCB, "C" curve, 10 KA breaking capacity
40 amps ratings, TPN MCB, "C" curve 10 KA breaking capacity
Supply and fixing surface mounted 10/12 watt LED type bulk-head fitting comprising of presure die cast housing with acrylic diffuser (IP65) protection and complete with integrated electronic driver etc. directly on wall / ceilling including connections etc. as required. (But without lamp)
Metre
Metre
Metre
Metre
Providing and fixing of lightning conductor finial, made of 25 mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate i ncluding holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
meter
Metre
Metre
Metre
meter
Metre
Metre
Metre
Jointing copper /G.I. tape (with another copper/ GI tape, base of the finial or any other metallie object) by riveting /nut bolting/sweating and soldering etc as required.
meter
meter
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
125A FP 25KA MCCB with extended rotary handle - 1 nos.
11 KV DOUBLE POLE STRUCTURE Supply, erection, testing and commissioning of 2 pole structure for providing 1 No. 11KV,400A GOS in accordance with IE rules, & local authority specification and drawings and comprising of the following.
SITC of 11 KV/433,500 KVA Outdoor Type Compact SubStation with Oil Type Transformer
Supplying, installation, testing & commissioning of factory made automatic power factor control panel of following KVAR capacity having single phase MPP type, self healing, low loss capacitor filled with suitable capacitor grade oil & housed in AL can mounted on modular racks of max 50 KVAR capacity and minimum 12.5KVAR and having current limiting contactor circuit to supress switching inrush current to improve capacitor life. The system shall have multistep microprocessor based power factor controller.
Supplying, installation, testing & commissioning of floor mounted cubical type(42 Sq.FT) LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,having following capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 25 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears, switch gears to cable alley with required size of Al. bus bars and control wiring with 2.5 .sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-
Supplying, installation, testing & commissioning of floor mounted cubicall type (25 Sq.Ft) LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,having following capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 25 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears, switch gears to cable alley with required size of Al. bus bars and control wiring with 2.5 .sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-
Supplying, installation, testing & commissioning of floor mounted cubical type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,having following capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 25 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears, switch gears to cable alley with required size of Al. bus bars and control wiring with 2.5 .sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-
Supplying, installation, testing & commissioning of floor mounted cubical type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,having following capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 25 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears, switch gears to cable alley with required size of Al. bus bars and control wiring with 2.5 .sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-
Supplying, installation, testing & commissioning of floor mounted cubical type (25 sqft) LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,having following capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 25 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears, switch gears to cable alley with required size of Al. bus bars and control wiring with 2.5 .sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-
Carbon dioxide (CO2) type fire extinguisher (conforming to IS 2878) with cylinders fully charged of capacity 4.5 Kg.) mounted on wall hooks.
Dry chemical powder type fire extinguisher of 6 kg capacity as per IS 2171 mounted on wall hooks
G.I. buckets of 5 Nos. 9.5 litres capacity painted with red oxide paint and written with White paint 'Fire' and mounted on free standing stand as required including filling with dry sand.
First aid box as approved by St. John Ambulance Brigade/Indian Red Cross conforming to IS : 2217-1963.
Shock treatment chart in Hindi and English duly mounted on a wooden frame with glass
Rubber mat 914.4 mm. wide and 12 mm. thick to withstand 3.3 KV dielectric strength as per IS 5424 - 1969.
Rubber mat 914.4 mm. wide and 12 mm. thick to withstand 11 KV dielectric strength as per IS 5424 - 1969.
Rubber gloves of 11 KV grade as per IS 4770-68.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supply, installation, testing and commissioning of Silent Type diesel generating set comprising of CPCB IV Model 199 BHP @ NTP , 1500 RPM Coupled to 160KVA LEYROMER 3 PHASE 415 VOLT ,50 HZ Alternator mounted on acommon base frame along with other accessories i.e. fuel tank AMF CONTROL PANEL, BATTERY WITH LEADS AND ACOUSTIC ENCLOSURE (CPCB-4 Standard)
25 mm dia MS fuel (Considering DG set shall be placed at a distance of 5-6 from fuel tank
Set of fiiting accessories such as valves, tees, elbows etc.
Smart-UPS On-Line, 5.4 kW / 6 kVA with 1 hour Backup12 V 65 AH SMF Battery UPS Toplogy Double Conversion On-Line, Power Rating (VA / Watts) 5400Watts/6000VA, Form Factor Rack/Tower Convertible; Output Power Capacity 5400 Watts/6000 VA, Max Configurable Power 5400Watts/6000VA, Nominal Output Voltage 230V, Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage, Efficiency at Full Load 94.00%, Output Voltage Distortion Less than 3%,Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz,Crest Factor 03:01,Waveform Type Sine Wave, Output Connections (1)*Hard Wire 3-wire (8)*(H N + G) IEC 320 C13(8),Bypass Built-in Bypass, Output Short Circuit Protection Yes,Parallel Redundancy (Option) 1 + 1, Nominal Input Voltage 230V,Input Power Factor>0.98,Input Frequency 40-70Hz,Input Connections Terminal Block, Protection Thermal Circuit Breaker (250VAC/20A), Input voltage range for main operations full load 160 - 285V, Input voltage range for mains operation half load 160-285V, High Voltage withstand Capability 420 VAC, Green Mode Range 210-250 VAC (230 V), Battery Type Mintenance - free sealed Lead-Acid battery with suspended, electrolyte. 12V 65 Ah SMF battery for 60 Min Battery Back up.
Supply and erection of 4 metre height Hot-dip galvanized octagonal street light pole with top dia 70 mm and bottom dia A/F 130 mm , made of 3 mm thick sheet along with base plate of size 220 x 220 x 12 mm small door opening for junction box mounting including 6 A 'C' series SP MCB, connector , and suitable size foundation bolts with template as required (But without pole foundation)
Single arm, 1000 mm
Supplying and fixing watt LED type street light with minimum efficacy 100 Im/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc. on pole/building including connection earthing the body etc as required.
Supplying & drawing 3x2.5sq.mm size FR PVC insulated copper conductor single core cable in the existing pipe as rqd.
Supply and fixing fabricated Feeder pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator, with 40mm X 40mm X 5mm angle iron stand and complete in all respect etc and must be CPRI approved panel manufactures. (But without RYB LED lamp, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears, PCC work etc.)
Meter
Supply, erection, testing and commission of lift travelling from ground floor to 4 th floor, stopping at 5 floors and opening on one side only with/without attendant complete with light in lift shaft and lift pit, providing ladder in lift pit, providing necessary scaffolding required for erection of lifts and minor buildings work comprising of cutting holes and making good the same for the car, counter weight, brackets, call buttons and indicators and including painting of all steel items as required.
After Warrenty/ Guarenty
Supply, erection, testing and commission of lift travelling from ground floor to 4th floor, stopping at 5 floors and opening on one side only with/without attendant complete with light in lift shaft and lift pit, providing ladder in lift pit, providing necessary scaffolding required for erection of lifts and minor buildings work comprising of cutting holes and making good the same for the car, counter weight, brackets, call buttons and indicators and including painting of all steel items as required.
After Warrenty/ Guarenty
Supply, erection, testing and commission of lift travelling from ground floor to 3 rd floor, stopping at 4 floors and opening on one side only with/without attendant complete with light in lift shaft and lift pit, providing ladder in lift pit, providing necessary scaffolding required for erection of lifts and minor buildings work comprising of cutting holes and making good the same for the car, counter weight, brackets, call buttons and indicators and including painting of all steel items as required.
After Warrenty/ Guarenty
Supply, Installation, Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mountedon Aluminium/GI structure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286/ IEC61215, IS/IEC61730-Part-1, IS/ IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% attheend of 25 years. b)Power Conditioning Unit (PCU) of 350-800V DC Input voltage range and 400V AC, three phase, 4 wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion
Item Code. SOR-22
Earth work in excavation over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m ; disposed earth to be levelled and neatly dressed.
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
per 50 kg cement
Metre
TMTC-500- 8mm dia .
TMTC-500-10 mm dia.
TMTC-500-12 mm dia.
TMT FE-500-16 mm dia.
TMT FE-500-20 mm dia.
TMT FE-500-25 mm dia.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :
Cement mortar 1:6 (1 cement: 6 coarse sand ) - 250 mm th Brick work
Half brick Masonary Cement mortar 1.:4 (1 cement: 4 coarse sand ) - 125 mm th Brick work
Brick work with bricks of class designation 100A in foundation and plinth in :
cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with bricks of class designation 100A in foundations and plinth in :
Cement mortar 1:4 ( 1 cement: 4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia . M.S. bars at every third course of half brick masonry ( with FPS brick).
Extra tor Brick work in superstructure above plinth level upto floor V cum
Metre
Steel windows
Providing and fixing ISI marked steel wire gauged doors, windows and ventilators of standard rolled steel sections, joints mitered and welded with 15x3 mm lugs, 10 cm long , embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using galvanized M.S. wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm with 12 mm mild steel beading complete including applying a priming coat of approved steel primer, but excluding the cost of other fittings except necessary hinges or pivots as required
metre
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Metre
1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.
IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.
IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area.
IVth course of 400 micron thick PVC sheet (overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm
Providing plinth protection 750 mm wide consisting of 12 mm thick cement plaster 1;6 with neat cement punning over 75 mm thick P.C.C. (1:3 :6) over brick flat soling over 75 mm thick local sand filling all complete
Metre
Compacting original ground Compacting original ground supporting subgrade (Loosening of the ground upto a level of 500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of table 300-2 for subgrade construction)
Construction of subgrade and Earthen Shoulder (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)
Granular Sub-Base with Graded Material ( Table:- 400- 1) Plant Mix Method (Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.)
Rate per cum for grading-II Material
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
Trees
Shrubs / Creeps
Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I.
Bricks (Lead - 1 km kutcha + 7 km pucca)
Coarse Sand (Lead- 171 km) from Koilwar
Stone Chips (Lead-244 km) from Manpur, Gaya
Stone Metal (Lead-244 km)
Local sand (1 km kutcha + 2 km pucca)
Earth (1 km kutcha + 2 km pucca)
Cement
Bricks
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
per litre
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge.
Providing, fixing, testing and commissioning of CP brass swan neck wall mounted sink mixer with wall flange and swinging casted spout complete as required and making good the walls wherever required.
Providing, Fixing air freshner on wall face with necessary rawl plugs and steel screws complete in all respects, including cutting and making good the wall wherever required.
Providing, Fixing satin finish stainless steel AISI 316 grade wall mounted coat hooks on door with CP brass wall brackets and CP brass screws complete in all respects, including cutting and making good the wall wherever required.
Providing, Fixing, testing and commissioning of adjustable type wash basin with elbow oprated tap for handicap toilet complete with brackets, tracks, waste pipes and other accessories complete including cutting and making good the walls wherever required.
Providing, Fixing, testing and commissioning of raised toilet seat with cover for handicap toilet including providing & fixing CP bolts, nuts, fisher/anchor bolt are required for hangong of WC complete with all accessories. Including cutting & making good the walls & floors wherever required.
Providing, Fixing, testing and commissioning of wall mounted 32 mm dia seamless stainless steel tube coated with nylon non-slip gripping surface hinged Hand Rail 750 x 100 mm complete in all respects, including cutting and making good the wall wherever required.
Providing, Fixing grab bar fabricated from 32 mm dia seamless stainless steel tube coated with nylon non-slip gripping surface 600 mm long grab bar in toilets for physically handicapped complete in all respects, including cutting and making good the wall wherever required. For Wash Basins & Water Closet.
Supply, Fixing, testing & commissioning of storage type stainless steel water cooler with inbuilt RO system, including angle valve and flexible connection piping of the following capacity. It shall have C.P brass push cock complete with inlet float valve (with angle valve) with all plumbing and electrical accessories, inlet, outlet, overflow and PVC drain out connection to F.D complete as required.
Metre
Metre
Metre
Metre
Metre
Metre
Providing and fixing, testing and commissioning of reducing floor drain of 110x63 mm OD as floor drain in cement concrete 1 : 2 : 4 float with floor complete in all respects.
Providing and fixing, testing and commissioning of uPVC multi angle inlet hight riser fittings with 3 or 4 side inlets of 40, 50 & 63 mm size and fixed to uPVC traps with drip seal/m-seal/solvent cement joint complete in all respect.
Providing and fixing cast brass Clean Out plug with suitable insert keys for opening, male threaded joint with G.I. socket lead caulked to soil pipe/waste pipe of C.I. and C.I.(LA) pipe as required complete
100mm dia
Providing, fixing, jointing and testing of uPVC pipes conforming to IS 4985 class III (6 kg/cm2) including injection moulded fittings with bosses like bends, tees, adoptors etc. suitable for rubber ring jointing complete including fixing to walls with clamps and hanging from ceiling to grade on adjustable supports.
40 mm dia
50 mm dia
63 mm dia
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
metre
Metre
Metre
Metre
Metre
Metre
Metre
metre
metre
metre
metre
metre
20 mm nominal bore
Providing, fixing, testing & commissioning of vertical multistage centrifugal pumping set with stainless steel SS-304 stage casing and SS304 impellers with stainless steel SS304 shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440 volts, 3 phase, 50 Hz AC supply with pressure gauge and with gunmetal isolation cocks, vibration elimination pads etc. complete with base and frame, nuts and bolts and necessary RCC foundations as per requirement as per instructions and pump shall have following duty.
Pumps for Domestic Water Supply (Hydropneumatic)
Providing,fixing, testing & Commissioning of Sump Pumps for lifting water from drainage sumps in plant room
Complete piping 100mm dia common delivery upto 5m as per enclosed tentative layout. (The pipe should be preferably CI LA/heavy duty G.I) -- 1 Set
80mm dia butterfly valve.-- 2 Nos
80 mm dia NRV valve.-- 2 Nos
Necessary cables from pump set to control panel (position of panel marked in enclosed layout in plant room).-- 1 Set
Electrical switch panel having all necessary accessories & safety devices of standard specifications. (Panels with sump pumps near each sump as per site conditions). - 1 No.
Automatic built-up water level controller with necessary length of cable upto control panel.
Providing and fixing brass Single acting air valve PN 1.6 of approved quality with bolts, nuts, rubber insertion, tail pieces, tapers etc. if required as complete.
25 mm dia
Providing and fixing motorised butterfly valve with float type sensors suitable for 240 volts with working pressure rating of not less than 5 kg/cm2 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box etc., complete.
Metre
Metre
Metre
Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia
Pipes, cables etc exceeding 300 mm dia
Metre
Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
metre
Metre
metre
Metre
metre
Metre
metre
metre
metre
Supply fixing 2 HP Motor Pump (1 Unit) with 32 mm dia clamp (1 Unit), Suitable Length of cable, Panel Board & Starter (1 No.), centre Guide (6 Nos.) Machine Up and Down etc. all complete
Metre
Metre
Metre
Metre
Metre
Providing and fixing of weather proof standard HOSE CABINATE ( 0.6 M x 0.45 M x 0.3 M ) having central opening glazed door with 6 mm thick clear glass including necessary locking arrangement with Allan key, power coating with PO red paint and for housing 2 nos. RRL hose pipe, 1 No branch pipe. as reqd.
Providing & making drainage provision for the riser with 25 mm dia BALL VALVE completed as required
Supplying of XLPE/PVC insulated Sheathed (Heavy Duty) armoured electric cable with aluminium conductor of 1.1 KV graded con. IS 1554 Part I upto date amendment etc as required of following size
Power Cable 4 core x 16 mm2
3.5 core 35 sqmm
ABC Powder Type (Stored Pressure) Fire Extinguisher, 4 kg. Capacity, ISI mark (IS:15683), squeeze grip valve, operating temperature (+5) degree Celcuis to (+55) dgree Celcuis for Class 3A Type of Fire Filled with MAP ABC Powder, Complete in all respect
CO2 Type Fire Extinguisher, 4.5 Kg Capacity, ISI Mark (IS:15683) squeeze grip valve, operating temperature (-30) deg Cel to (55) deg cel. For Class 13B type of Fire Fitted with 1 Mt. Hose & PVC Horn, Complete in all respect.
Structure is made up of 40 mm dia CRC tube with thickness 18 gauge. Horizontal base is made from steel sheet the thickness 14 gauge. Horizontal base will be stiffened with appropriate longitudinal 3 v shape sheet and lateral stiffeners 2 steel pipes with powder coating. Manufactured out of ISO 9001, ISO14001 and OSHSAS 18001 certified Plant and product certified for BIFMA performance test (Size : 2000 x 900 x 650 mm (H)
Supplying and fixing of Mattress (size : 75"x36" x 2" thick) at site, with complete in all respect or as per direction of E/I
Dimension : DESK - 600 W x 480 D x 750 H SEAT - 868 H x 500 W x S 450 Finish/Coating : Powder Coating Material : MILD STEEL TUBULAR SECTION OVAL Tube 35 x 15 SQ. Tube 25x25 and PLB & Moulded wood Total Weight : 23Kg Available Base Frame : Knock down Features : >SEMI KNOCKDOWN > 11 TANK HOT ZINC PHOSPHATING PRE TREATMET PROCESS > Powder Coated
Size: Executive Desk Size - 1800mm (W) x 900mm (D) x 750mm (H) Side Unit - 1800mm (W) x 600mm (D) x 675mm (H) Combination of metal and wood reflects dynamism. Sleek floating top gives aesthetic and trendy look. Open rectanglular section legs with small modesty gives the table trendy, airy open look.
Size : 2.40 m x 1.05m x 750mm Providing & making meeting table of given size made of 35mm thick block board with 1.0mm thick laminate at top and 1-1/2" TW beading on all the sides with proper niche in between beading and laminate edge 25mm thick round laminated pedestal and wooden frame work 75 x 62mm T.W bracket as top support including polishing of wooden frame work and melamine finish all complete as per drawings.
Class room desk - 2 seater with pedestal storage unit (for Class room) & sitting Desk (size : 1050 x 450 x750 (H)) Supply,Fabrication & Installation of class room table top 19 mm thick prelimanated board with 2mm PVC edge banding , supported on MS square Hollow section (size : 40 mm x 40 mm) frame complete with wire manager at table top all fitting & assecories as per drawing & direction of E/I.
Seat/Back Assembly: The seat is made up of 1.2 ±0.1cm thick hot pressed plywood measured as per QA method described in OCP-QLTA- P14-18 and upholstered with fabric moulded Polyurethane Foam. The back is made up of 1.2 ±0.1cm hot pressed plywood upholstered with fabric moulded polyurethane foam. The back ply and foam is designed with contoured lumber support for comfortable seating posture. Mid Back Size - 48cm (W) x 64.5cm (H). Seat Size - 51cm (W) x 48cm (D) Armrest (Adjustable): The armrest top is made up of moulded polyurethane (P.U) and mounted on to a drop lift height adjustable type M.S. tubular armrest support chrome plated. The armrest height is adjustable up to 6.5±0.5cm in 5 steps & also has swivel adjustment of 22° ± 2° on both sides. Knee Tilt Synchro Mechanism with Seat Deapth Adjustment Mechanism: The mechanism is designed with the following features - 360° revolving type, Single point control, Front pivot for tilt with feet resting on ground ensuring more comfort, Tilt tension adjustment, 4-position locking with anti-shock feature, Seat back tilting ratio of 1:2 & Seat depth adjustment of 6.0 ± 0.5cm can be locked in 6 positions. Adjustable Backrest: The backrest consists of a sliding up down mechanism, which can be adjusted in the range of 7.5 ± 0.5cm and can be locked in 4 positions for correct position of lumber support. Pneumatic Height Adjustment: The pneumatic height adjustment has an adjustment of 9.0 ± 0.3cm. Pedestal Assembly: The pedestal is fabricated from 0.2 ± 0.2cm thick HR sheet (IS : DD 1079 / HR skin pass), chrome plated and assembled with injection moulded black polypropylene hub cap and 5 nos. twin wheel castors. The pedestal is 66.0±0.5cm Pitch-center dia. (76.0 ± 1.0cm with castors). Twin Wheel Castors: The twin wheel castors are injection moulded in black Nylon.
S/F ct site Godrej steel Multifux system of size 7' x 36 " x 18" with 7 nos. shalves of galvanised steel sheet with M.S steel angle frame of size 40x40x8 mm. Complete with supplying and fixing at site with including painting etc. as per direction of E/I
Table for class room/office (size : 1200 x 900 x 750) Supply, Fabrication & Installation of table made of Powder coated MS frame with 18mm thick prelaminated board top complete in all respect with wire manager lockable drawers etc. all complete as per drawing and direction of E/I
Work Surface: 25mm Thick (±1mm) Base Material - 25mm MDF Board on top PU painting of Minium 2H hardness with 75% glass as per color chart, combination color graphics on the centre. Color as per color chart. Brown laminate on bottom. Specially profiled edge for comfort. Understructure: Bend pipe understructure of MS. Powder Coated. Pipe dia. 38mm, 2mm thk. Understructure fitted with top by SS machine screws. Legs: MS Powder coated legs for PU top & SS legs for membrane top. 38mm dia pipe legs are fixed with understurcture and table top. Glide: Plastic Glide fixed at the understructure to prevent the damage of table top druing stacking. Size: Ground Base - 2450mm (L) x 1175mm (W). Surface Top - 2400.8mm (L) x 1050.4mm (W) & Height - 750mm (H)
Seat/Back: Seat & Back are injection moulded in PP. They are snap fitted on the understructure assembly and fixed with self-taping screws Approx. Back Size : 37.0cm (W) x 25.5cm (H) Approx. Seat Size : 40.5cm (W) x 40.5cm (D) Understructure Assembly: The understructure assembly is a welded frame assy. with the upper frame made of dia. Ø 1.9±0.02cm x 0.2±0.016 thk. and legs made of Ø 1.9±0.02cm x 0.16±0.0128cm thk. M.S. E.R.W tubes and black powder coated (DFT 40-60 microns)
Size : Depth (D) - 57.0 cm Width (W) - 58.0 cm Height (H) - 88.0 cm Seat Height (SH) - 47.5 cm The seat & Back are made up of Cushion covered with rexine. Behind all this is a robust tubular framework that makes the chairs durable.
Providing and fixing in position magnatic white board on walls including teak wood edge moulding. Complete with all necessery hardware, polish etc as per direction of E/I Size : 8' x 4'
3 sector chair (Chrome) Made of Cushion with high density cold cured self -skinned pre -molded foam of 50-60 density the shape of plywood. Upholstery is done by using high-pressure pneumatic spray glue and pneumatic press over crome base & legs etc. all complete as per direction of E/I
Computer Table - (size : 900 x 600 x 905 mm) computer Lab Supply and installation of Prelaminated particle board of wood finish on both side and top on hard wood frame with drawer, Cabinet and wire manager complete with all necessary hardware and as per drawing design and direction of E/I.
Computer Chair : Supply and installation of Telemate medium back chair with single point lock tilting mechanism castor and latherlite sheet over PU foam sheet complete on crome base
Point
Point
Point
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
meter
meter
8 way , Double door
NORMAL PANEL-SCHOOL
40 A to 63 A rating, Four pole MCB, "C" curve, 10 KA breaking capacity
DG PANEL-SCHOOL BUILDING
40 A to 63 A rating, Four pole MCB, "C" curve, 10 KA breaking capacity
40 A to 63 A rating, Four pole MCB, "C" curve, 10 KA breaking capacity
40 amps ratings, TPN MCB, "C" curve 10 KA breaking capacity
Supply and fixing surface mounted 10/12 watt LED type bulk-head fitting comprising of presure die cast housing with acrylic diffuser (IP65) protection and complete with integrated electronic driver etc. directly on wall / ceilling including connections etc. as required. (But without lamp)
Metre
Metre
Metre
Metre
Providing and fixing of lightning conductor finial, made of 25 mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate i ncluding holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
meter
Metre
Metre
Metre
meter
Metre
Metre
Metre
Jointing copper /G.I. tape (with another copper/ GI tape, base of the finial or any other metallie object) by riveting /nut bolting/sweating and soldering etc as required.
meter
meter
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
125A FP 25KA MCCB with extended rotary handle - 1 nos.
11 KV DOUBLE POLE STRUCTURE Supply, erection, testing and commissioning of 2 pole structure for providing 1 No. 11KV,400A GOS in accordance with IE rules, & local authority specification and drawings and comprising of the following.
SITC of 11 KV/433,500 KVA Outdoor Type Compact SubStation with Oil Type Transformer
Supplying, installation, testing & commissioning of factory made automatic power factor control panel of following KVAR capacity having single phase MPP type, self healing, low loss capacitor filled with suitable capacitor grade oil & housed in AL can mounted on modular racks of max 50 KVAR capacity and minimum 12.5KVAR and having current limiting contactor circuit to supress switching inrush current to improve capacitor life. The system shall have multistep microprocessor based power factor controller.
Supplying, installation, testing & commissioning of floor mounted cubical type(42 Sq.FT) LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,having following capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 25 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears, switch gears to cable alley with required size of Al. bus bars and control wiring with 2.5 .sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-
Supplying, installation, testing & commissioning of floor mounted cubicall type (25 Sq.Ft) LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,having following capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 25 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears, switch gears to cable alley with required size of Al. bus bars and control wiring with 2.5 .sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-
Supplying, installation, testing & commissioning of floor mounted cubical type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,having following capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 25 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears, switch gears to cable alley with required size of Al. bus bars and control wiring with 2.5 .sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-
Supplying, installation, testing & commissioning of floor mounted cubical type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,having following capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 25 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears, switch gears to cable alley with required size of Al. bus bars and control wiring with 2.5 .sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-
Supplying, installation, testing & commissioning of floor mounted cubical type (25 sqft) LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade,having following capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 25 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears, switch gears to cable alley with required size of Al. bus bars and control wiring with 2.5 .sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-
Carbon dioxide (CO2) type fire extinguisher (conforming to IS 2878) with cylinders fully charged of capacity 4.5 Kg.) mounted on wall hooks.
Dry chemical powder type fire extinguisher of 6 kg capacity as per IS 2171 mounted on wall hooks
G.I. buckets of 5 Nos. 9.5 litres capacity painted with red oxide paint and written with White paint 'Fire' and mounted on free standing stand as required including filling with dry sand.
First aid box as approved by St. John Ambulance Brigade/Indian Red Cross conforming to IS : 2217-1963.
Shock treatment chart in Hindi and English duly mounted on a wooden frame with glass
Rubber mat 914.4 mm. wide and 12 mm. thick to withstand 3.3 KV dielectric strength as per IS 5424 - 1969.
Rubber mat 914.4 mm. wide and 12 mm. thick to withstand 11 KV dielectric strength as per IS 5424 - 1969.
Rubber gloves of 11 KV grade as per IS 4770-68.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supply, installation, testing and commissioning of Silent Type diesel generating set comprising of CPCB IV Model 199 BHP @ NTP , 1500 RPM Coupled to 160KVA LEYROMER 3 PHASE 415 VOLT ,50 HZ Alternator mounted on acommon base frame along with other accessories i.e. fuel tank AMF CONTROL PANEL, BATTERY WITH LEADS AND ACOUSTIC ENCLOSURE (CPCB-4 Standard)
25 mm dia MS fuel (Considering DG set shall be placed at a distance of 5-6 from fuel tank
Set of fiiting accessories such as valves, tees, elbows etc.
Smart-UPS On-Line, 5.4 kW / 6 kVA with 1 hour Backup12 V 65 AH SMF Battery UPS Toplogy Double Conversion On-Line, Power Rating (VA / Watts) 5400Watts/6000VA, Form Factor Rack/Tower Convertible; Output Power Capacity 5400 Watts/6000 VA, Max Configurable Power 5400Watts/6000VA, Nominal Output Voltage 230V, Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage, Efficiency at Full Load 94.00%, Output Voltage Distortion Less than 3%,Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz,Crest Factor 03:01,Waveform Type Sine Wave, Output Connections (1)*Hard Wire 3-wire (8)*(H N + G) IEC 320 C13(8),Bypass Built-in Bypass, Output Short Circuit Protection Yes,Parallel Redundancy (Option) 1 + 1, Nominal Input Voltage 230V,Input Power Factor>0.98,Input Frequency 40-70Hz,Input Connections Terminal Block, Protection Thermal Circuit Breaker (250VAC/20A), Input voltage range for main operations full load 160 - 285V, Input voltage range for mains operation half load 160-285V, High Voltage withstand Capability 420 VAC, Green Mode Range 210-250 VAC (230 V), Battery Type Mintenance - free sealed Lead-Acid battery with suspended, electrolyte. 12V 65 Ah SMF battery for 60 Min Battery Back up.
Supply and erection of 4 metre height Hot-dip galvanized octagonal street light pole with top dia 70 mm and bottom dia A/F 130 mm , made of 3 mm thick sheet along with base plate of size 220 x 220 x 12 mm small door opening for junction box mounting including 6 A 'C' series SP MCB, connector , and suitable size foundation bolts with template as required (But without pole foundation)
Single arm, 1000 mm
Supplying and fixing watt LED type street light with minimum efficacy 100 Im/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc. on pole/building including connection earthing the body etc as required.
Supplying & drawing 3x2.5sq.mm size FR PVC insulated copper conductor single core cable in the existing pipe as rqd.
Supply and fixing fabricated Feeder pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator, with 40mm X 40mm X 5mm angle iron stand and complete in all respect etc and must be CPRI approved panel manufactures. (But without RYB LED lamp, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears, PCC work etc.)
Meter
Supply, erection, testing and commission of lift travelling from ground floor to 4 th floor, stopping at 5 floors and opening on one side only with/without attendant complete with light in lift shaft and lift pit, providing ladder in lift pit, providing necessary scaffolding required for erection of lifts and minor buildings work comprising of cutting holes and making good the same for the car, counter weight, brackets, call buttons and indicators and including painting of all steel items as required.
After Warrenty/ Guarenty
Supply, erection, testing and commission of lift travelling from ground floor to 4th floor, stopping at 5 floors and opening on one side only with/without attendant complete with light in lift shaft and lift pit, providing ladder in lift pit, providing necessary scaffolding required for erection of lifts and minor buildings work comprising of cutting holes and making good the same for the car, counter weight, brackets, call buttons and indicators and including painting of all steel items as required.
After Warrenty/ Guarenty
Supply, erection, testing and commission of lift travelling from ground floor to 3 rd floor, stopping at 4 floors and opening on one side only with/without attendant complete with light in lift shaft and lift pit, providing ladder in lift pit, providing necessary scaffolding required for erection of lifts and minor buildings work comprising of cutting holes and making good the same for the car, counter weight, brackets, call buttons and indicators and including painting of all steel items as required.
After Warrenty/ Guarenty
Supply, Installation, Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mountedon Aluminium/GI structure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286/ IEC61215, IS/IEC61730-Part-1, IS/ IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% attheend of 25 years. b)Power Conditioning Unit (PCU) of 350-800V DC Input voltage range and 400V AC, three phase, 4 wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT 08.pdf
NIT • 1.42 MB
BOQ_Sheohar.xls
NIT • 2.41 MB
NIT 08.pdf
NIT • 1.42 MB
SBD_SHEOHAR.doc
NIT • 8.66 MB
CHECK LIST FOR CONTRACTORS.pdf
NIT • 1.76 MB
JVG.pdf
NIT • 1.20 MB
BOQ_Sheohar.xls
NIT • 2.41 MB
Download all tender documents and submit your bid