| 1 | L1₹50.0 LAccepted-AOC GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹50.8 L+₹77,857 (1.56%)Rejected-Finance VILLAGE BHANADA TEH ABADASA DISTT KUTCH PIN 370645 GUJARAT | KACHCHH | GUJARAT | 370645 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹52.0 L+₹2.0 L (3.96%)Rejected-Finance T 1 GARDEN VIEW APARTMENT NEW BANKER COLONY MUNDRA ROAD BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L3 | Rejected-Finance NOT BEING L1 |
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
30 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHIEF ENGINEER CG GOA
HQ CE CG GOA 403806
ADDITION ALTERATION TO P2 BUILDING ALONGWITH TOILETS, BATHROOM AND PROVN FLAG MAST GARDEN LIGHT FOR OFFICER MESS AT CGRA NALIYA AND ELECTRIC SIREN HT POWER SUPPLY WITH CONNECETD ITEMS FOR SHIP SUPPORT COMPLEX AT CG JETTY AT ICGS JAKHAU
2023_MES_581651_1
83008/E8
Open Tender
Civil Works
Item Rate
180 days
JAKHAU
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
AGE (I) CG JAKHAU
₹1.1 L
Yes
18 Apr 2023
17 Feb 2023
1 Apr 2023
17 Feb 2023
30 Mar 2023
16 Mar 2023
Amount
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft loose soil all as specified and directed.
Excavation in trenches not exc 1.5m wide and n. exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and not exc 1.5 depth and getting out in soft/loose soil all as specified and directed.
All as per serial item No 2 above but depth exceeding 1.5 m and not exceeding 3 mtrs and getting out in soft/loose soil all as specified and directed.
All as per serial item No 2 above but in soft/disintegrated soil and getting out all as specified and directed.
Excavation over areas n. exc 1.50 m deep and getting out in soft/ loose soil all as specified and directed
Returning, filling with earth obtaned from excavation, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick etc all as specified and directed.
Removing excavated material at a level not exc. 50m and depositing where directed at a level not exc.1.5 m above the starting point all as specified and as directed.
M & L for Sand filling under floors or in foundations including spreading, levelling, watering and consolidation in layers of n. exc 25cm thick etc all as specified and directed.
M & L for broken stone boulders hardcore of gauge 63mm but n. exc 100mm deposited, spread and levelled in layers n. exc 15cm thick, watered, rammed to a true surface etc complete all as specified and directed.
M&L cement concrete 1:4.8 Type D2 using 40mm stone aggregate in foundations filling and mass concrete all as specified and directed.
M&L 75mm thick cement concrete in floor finish 1:4.8 Type D2 using 20mm stone aggregate etc all as specified and directed.
M&L 100mm thick cement concrete in sub base of floor 1:4.8 Type D2 using 40mm stone aggregate etc all as specified and directed.
M&L Pre-cast cement concrete block masonry Type C5 1:5:8 with solid blocks of any size and setting in cement mortar 1:6, complete all as specified and directed.
M& L for RCC design mix M-30 grade in foundation including raft, footings, foundation beams, plinth beams, bases of columns etc complete all as specified and directed.
M& L for RCC design mix M-30 grade in beams and like etc complete all as specified and directed.
M& L for RCC design mix M-30 grade in columns and like above the top of footing etc complete all as specified and directed.
M& L for RCC design mix M-30 grade in slab etc complete all as specified and directed.
M&L use and waste of formwork to sides of concrete foundations, footing bases of columns, raft & beams, side of soffits (if any) of foundation and plinth beams and similar work, vertical or to batter rough finished surface of concrete etc all as specified & directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns in vertical or to batter rough finished flat surface all as specified and directed.
M&L for Formwork to beams in vertical or to batter rough finished flat surface all as specified and directed.
M&L for Formwork to sides and soffits of suspended slab such as roof slab, floor slab, landings and similar works not exceeding 200mm thick (Horrizontle or sloping) etc all as specified & directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floor, window cills, concrete railings, opening in concrete walls, floor and roofs n. exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar works ecx 10cm but not exc 20cm wide etc all as specified & directed.
M&L for Mild steel bars TMT CRS of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc all as specified & directed.
S& F mild steel TMT CRS bars of 6 to 8mm dia as stirrups, cut to length, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified & directed.
M&L for 20mm thick screed bed in CM (1:3) mixed with water proofing compound as per manufacturers instructions on RCC slab/ chajjas while the concrete is still green and finished even and smooth without using extra cement etc complete all as specified and directed. NOTE: WPC shall be measured and paid sepertely under respective item.
Supply only Integral water proofing compound as specified
M&L for Figured glass 3mm thick, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane etc complete all as specified & directed.
Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, complete as specified by the manufacturer and as per directions of Engineer-in-charge etc complete all as specified & directed.
Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge etc complete all as specified & directed.
S&F 100mm size medium weight butt hinges extrued alluminium alloy with galvanized stainless steel hinge pin anodised by type B-22 etc complete all as specified & directed.
S&F 150mm size handle extrued alluminium alloy fabricated type, anodised etc complete all as specified & directed.
S&F aluminium anodized 150mm length of bolt barrel tower bolts of extrued section etc complete all as specified & directed.
M&L Rendering 10mm thick in CM 1:6 on fair faces of brick work/block or concrete surfaces finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L Rendering 5mm thick in CM 1:3 on fair faces of brick work/block or concrete surfaces finished the surface even and smooth complete all as specified and as directed.
M&L in repair 20mm UPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.
M&L in repair 15mm UPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.
S&F 20mm dia bore Gate valve, Gun-metal, screwed down high pressure with iron wheel head, screwed both ends for iron pipe or for union etc complete all as specified and as directed.
S&F Bib taps, 15mm bore, cast copper alloy CP fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for union etc complete all as specified and as directed.
S&F Two way Bib taps, 15mm bore, cast copper alloy CP fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for union etc complete all as specified and as directed.
S&F PVC valve less, syphonic action type flushing cistern 10 litre capacity, low level, white with inter ball valve, float and handle including brackets and flush pipe of polythelyne of low or high density or PVC, 32mm dia suitable for low level cistern etc complete all as specified and as directed.
S&F for PVC connections 15mm size with PTMT nuts of length 450mm etc complete all as specified and as directed.
S&F for vitreous china wash down water closet pan (Pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe) etc complete all as specified and as directed.
S&F for vitreous china wash hand basin, white Counter sunk incl chromium plated waste fittings, 32mm bore size waste pipe, PVC 65mm long and making good disturbed surfaces to match with the existing etc complete all as specified and as directed.
S&F Pillar taps of 15mm bore, swan neck, cast copper alloy with capstain heads, chromium plated, screwed down high pressure with or without letterd Hot or Cold with long screwed shanks and fly uts, screwed for iron pipe and fixed etc complete all as specified and as directed.
S&F for vitreous china bowl urinal, flat back of size 465 x 355 x 265mm, white including providing & fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe incl fixing supply pipe to flushing cistern, trap and waste pipe etc complete all as specified and as directed.
S & F stop valves fancy type, chromium plated cast copper alloy screwed down high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions in 15 mm bore dia pipe etc complete all as specified & directed.
S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed in 25 mm bore dia. (Minimum weight 20mm-210gms) etc complete all as specified & directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors etc complete all as specified & directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors etc complete all as specified & directed.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with ruber ring joints fixed to wall, etc complete all as specified & directed.
S & F for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, bore of pipe in 110 mm, etc complete all as specifed and directed.
S&F PVC (SWR) bends 110mm bore in mm any radius with access door, etc complete all as specified & directed.
S&F PVC (SWR) bend 75mm bore any redious with access door.
S&F PVC(SWR) 75mm bore in mm vent cowl, etc complete all as specified & directed.
M&L rotational moulded polyethylene water storage tanks (cylindrical verical with closed top) hoisted and fixed in position all as specified in 1000 ltrs capacity complete all as specifed and directed.
S&F tubular towel rail 20 mm dia, D type, 60 cm long between flanges with brass chromium pated bracket etc complete all as specified and directed.
S&F for SS Towel Ring fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) etc complete all as specified and directed.
S&F of Soap dish, any type, fixed to plugs with chromium plated brass screws, vitreous China white, approximate size 160x 160x90mm etc complete all as specified and directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified etc complete all as specified & directed.
S & F in repair for 20mm dia SS curtain rod with fixing brackets, stops, rollers, etc complete all as spd and directed.
M&L for preparation of newly plastered surfaces & applying three coats of white wash by mechanical means on walls etc complete all as specified and directed.
M&L for preparation of newly plastered surfaces & applying three coats of white wash by mechanical means on ceilings/concrete surface etc complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2(40 mm graded aggregate) as in sub base surface etc completed all as specified.
M&L Screed bed or bedding layer or mortar 15mm layer of mortar 15mm thick for laying floor finishes in CM 1:4 etc completed all as specified.
M&L Non Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc completed all as specified.
M&L for rendering 10mm thick in CM 1:4 as backing coat to receive dado finished etc completed all as specified.
M&L for 450/300x200x7mm thick glazed coloured ceramic tiles as in vertical surface and jointed in neat cement slurry and pointed in white or coloured cement to match, etc complete all as specified & directed.
M&L PVC(SWR) floor trap/ nahani trap, plain with grating including jointing to waste pipe with solvent cement dia of outlet 75 mm etc complete all as specified and directed.
M&L Mild steel Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc.Fe-290(Gde-165) etc complete all as specified and directed.
S&F 150 mm bore reinforcement cement concrete pipe class NP2 laid and jointed complete with collar etc. complete all as specified and as directed.
M&L concrete bed in PCC 1:4:8 type D-2 to drain pipes of 150 mm bore including packing under and hunching against the sides of pipes after they are laid and tested etc. complete all as specified and as directed.
M&L cutting into existing man holes for connecting new drains of 150mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel 1/2 round or 3/4 section in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required etc. complete all as specified and as directed
M&L precast RCC 1:2:4 type B-1, using 20mm graded stone aggregate for manhole cover including placing over manhole all as specified including demolition of old RCC manhole covers etc. complete all as specified and as directed. Note: - Reinforcement shall be measured and paid separately under respectively items.
M&L cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate as in bed blocks, coping etc including necessary form work etc. complete all as specified and as directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in 15 mm thick screed bed cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps and other similar situations etc complete all as specified and directed.
S&F brass Chromium plated shower roses 125mm size with or without swivel joints suitable for fixing with 15 mm bore pipe including shower arm 15mm bore size with bend of 45 degree with flange etc. complete all as specified and directed
S&F salt glazed stone ware gully traps square or rounded mouthed type P or S of size 150 x 150cm etc complete all as specified and directed.
S&F 75mm bore PVC (SWR) junction single, (single T provided with access door), equal or unequal etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single, (single T provided with access door), equal or unequal etc complete all as specified and directed.
M&L for providing PVC sheet wall panelling of thickness 5mm(±0.25) consisting of panels of desired size stuck on inner frame work of 50 mm wide strips of 5 mm(±0.25) thick prelam PVC sheet. The panel & strips shall be density of 600 kg/Cum manufacture by an ISO-9001-2015 certified company. The strips should have in their centre a grove of 6 mm width and 1 mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10 inches between 2 PVC strips. The PVC strips shall be fixed to the wall using 65 mm long M.S. screws through the grove in the strips by using PVC fasteners. The distance between the two screws shall not be more then 200 mm. A groove of 2mm may be left at the joint of two panels for the aestehtic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optimally, a strips of 5 mm (±0.25) thick PVC sheets of width 75 mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement, etc complete all as specified & directed.
S&F powder coated aluminium frames incl sliding tracks, etc for doors, windows, ventilators, partitions with one or more rebates including jointing cleats for fixing, fittings like hinges, handles,locks, and also standerd closing and opening systems for louvers glass etc complete all as specified and as directed.
M&L for 5 mm thick figured glass pin head type and glazing with oil putty in square n.exc 0.5 sqm in each pane, etc all as specified and as directed.
M&L for Anodised aluminium snap grid of size of grid 605 x 605mm frame work for false ceiling Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified
M&L for Perforated particle board/tiles of 12mm thick for insula-tion and accoustic purposes,60x60 cm in size, fixed with nails to aluminium frame work or with staples on snap grid in ceiling,flat or sloping complete all as specified all as specified.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as per specified and directed.
M&L for rendering 15mm thick in cm 1:4 (10+5) finished even and smooth (without using extra cement) using integral water proofing compound Note ; Integral water proofing compond will be measured and paid separately, etc. complete all as per specified and directed.
Material & Labour for applying Two coats of 100% Premium acrylic Emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces, etc. complete all as per specified and directed.
S&F for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 ms/sqm) land on primed surface by forced applicationetc. complete all as per specified and directed.
M& L for Post construction Anti termite treatment by chemical emulsion (Immidacloprid 30.5 SC) as approved by IS 6313( part 3) : 2013 to Ground floor buildings adhering to following specifications: a) For internal area drill holes of 12-mm dia at 300 cms C/C along the inner junction of wall and floor in the entire premise. Water based chemical emulsion will be injected under pressure into these holes with dosage until refusal or maximum up to 1 Lit per hole. Minimum 400 ml chemical emulsion needs to be fill per hole. b) For external area drill holes of 12-mm dia at 300 cms C/C along the external junction of wall and floor in the entire premise. Water based chemical emulsion will be injected under pressure into these holes with dosage of 2.25 ltrs per rm. c) All drilled holes to be sealed with white cement and matched with surrounding wall finishes. d) Treatment to wooden fixtures: At point of contact of wood work by chemical emulsion ( in oil or kerosene based solution) @0.50 lt/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm center to centre and sealing the same to match existing finish. e) Treatment to termite tubes: Visible shelter mud tubes will be removed and the infested area treated with water based chemical emulsion. All the drilled holes will be sealed and made good using cement. f) Treatment to be done by specialist agency licensed by IPCA and approved by Eng in charge. Specialist agency need to give written warranty for 5 years with yearly inspection and contact details to be displayed on board for attendance of complaint. Note : plinth area of the building will be measured Specialist agency : PCI, Elite corporation, paragon pesticides or IPCA licensed approved by AGE (I)
S&F SS grating dia 125 mm dia, etc complete all as specified & directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level),etc completed all as specified.
M & L for light shade , Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, etc completed all as specified.
Demolition of cement concrete (unreinforced) any description and in any position not otherwise specifically provided for complete all as specified and as directed
Material and labour for 150mm thick cement concrete 1:2:4 type B-1 using 20mm graded agg as in flooring finished even and smooth without using extra cement, etc. complete all as per specified and directed.
Material and labour for cement concrete 1:3:6 type C-2, 75 mm thick using 40mm graded stone aggregates as in sub base without using extra cement, complete finished fair and even all as specified and as directed.
Material and labour for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete
Material and labour preparing New or previously untreated Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
Welded steel wire fabric supplied and fixed complete( n exc 4.00kg/sqm) to wood or steel members complete, all as specified.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps and platforms and like in 15 mm thick screed bed cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Material and labour for 20 mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, etc. complete all as per specified and directed.
Supply and fixing for Material & Labour for providing and fixing stainless steel (Grade 316) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing for stainless steel chain of grade SS/316 as in flag post including all fixing arrangements fixed grouted with and including necessary anchor bolts steel fasteners including welding grinded the corners for smoothening including necessary hook arrangements for flag rope etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing for Iron GI Flag Mast Pole GI coated of varying diameter including pulley assembly etc. complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 Sqmm, PVC insulated, unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and existing sunk type pressed steel terminal switch box 1.6mm thick with bakelite laminated sheet top cover 3mm thick, brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories for one light point/fan point controled by one one way swich complete all as specified and directed.
(a) One light point/bell point controlled by one way 5 Amps SP switch
(b) One exhaust fan point controlled by one, one way switch.
(c) One 5 pin 5 Amps socket outlet on same board with other switch
(d) One 5 Pin 5 Amps socket outlet on independent board with other switch.
Ditto all as per item No 104 above but with 2.5 Sqmm cross sectional area electric cable for 15 Amp socket outlet on independent board, complete all as specified and directed
Supply and fixing of switch piano type, flush button single pole, one way 5 Amps, complete all as specified and directed.
Supply and fixing of switch piano flush type 15 amps, single pole one way 240 volts complete all as specified and directed.
Supply and fixing of socket outlet 5 Amps, 5 Pin, flush type, complete all as specified and directed.
Supply and fixing of socket out let 2 in 1,multipurpose 3 pin 15/16 Amp flush type complete all, as specified & directed.
Supply and fixing ceiling rose surface bakelite 3 terminals 63.5 x 17 mm.
Supply and fixing recess mounted LED luminaire 18 watt, 6500k, compact, aluminium die cast housing edge lit slim panel square fixture with opal diffuser separate electronic driver.
Supply and fixing LED batten 10 watt, 2' ,230V complete
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp aluminimum painted bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with all fixing accessories complete all as specified and directed.
Supply and fixing of MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door IP-43 DB's , made out of sheet steel enclosure, recessed type, factory made powder coated 8 way, 240 volts suitable for housing MCB's including blanking plate complete all as specified and directed.
Supply and fixing of MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
Supply and fixing of MCB SPN, 240 volt, 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.complete all as specified and directed.
Supply and fixing of wall mounted fan 400 mm complete all as specified and directed.
Supply and fixing of Exhaust fan 300 mm sweep metal body complete all as specifies and directed.
Supplying & laying in repair factory made of unreinforced Precast concrete cover of class LV, type 1, flat, size 250 mm x 150 mm x40mm for protection for cable all as specified .
Dry Sand filling in cable trenches for protection of cables with two layers below and above cable and punned down to speicified thickness complete all as specified and as directed. Note: Punned down thickness shall only be measured for payment.
Supply and laying/fixing GI tubing light grade for cable protection of size 50 mm dia all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core
Danger notice plate for HT Pole of size 25 cmX20 cm of 1.6mm thick mild steel sheet viteous enameelled white with latter , figure and conventional skull and bones "DANGER" etc. in signal red colouer and fixed with MS clamps made out of 25mmX3mm MS flat bolts, nuts complete including two coats of aluminium paints over a coat of red oxide primer all as specified and directed.
Material an labour for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) all as specified and directed.
M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed by Engineer in Charge.
M&L for Cement concrete (1:4:8) type D-2 (using 40 mm graded aggregates) in sub- base and foundation filling for poles as mass concrete, complete all as specified and as directed.
M&L for Cement Concrete (1:3:6) type C-2 using 40 mm graded crushed stone aggregates for foundation filling of stays or poles as mass concrete complete with necessary form work required complete all as specified and as directed by Engineer in Charge.
Anti-climbing device, spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole all as specified and directed.
Supply , installation , testing commissioning over head line and at receiving station for 11 KV of ACSR conductor and of suitable size (weasel) & PG clamps, Tee clamp, Tee off clamps, spacers, JC parallel clamps etc complete all as specified.
Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade all as specified and directed.
Supply and install Gang Operated Air break Switch, tripple pole, outdoor mechanically operated from ground level suitable for horizontal or vertical operation mounted with drop out fuses having 12 insulators mounted on steel frames of rating upto 200 Amps complete all as specified and directed
Supplying and fixing in posiotion Lightning Arresters zinc oxide type complete with all fittings, transmission class, discharge capacity 65 kilo amp all as specified and directed
Supply, installation, testing and commissioning step down, 11/.433KVA (at no load) transformer not less than level-2, copper wound, outdoor type complete with standard fittings, platform mounted, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tapings on HT side to vary secondary voltage up to ±7.5% with step ± 2.5% including suitable cable entry boxes on LT and bushings on HT side all as per IS:1180 complete in all respects with standard accessories Dy -11 connection of capacity 250 KVA complete all as specified and directed. Salient features of transformer are as under:- (a) Transformer shall be oil immerse, naturally self cooled cooper wound, winding core type, MS radiator cool tank compete with first fill of transformer oil. (b) The following standard accessories shall also be provided:- (i) Rating and diagram plate (ii) Earthing terminals 2 Nos (iii) Lifting lugs (iv) Thermometer pocket (v) Air release hole with plug (vi) Tap changer with locking provision (vii) Conservator with oil indicator. (viii) Castors with locking provision (ix) Silica Gel breather complete (x) MS terminal box both on HT and LT site (xi) Oil temperature indicator with maximum & minimum temperature rise indicator. (xii) Plain breathing device which would not permit ingress of rain water and insects. (xiii) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xiv) Oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator)
S&F Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 120 KVAR without incoming MCCBs complete all as specified and directed
S&F MCCB 4 Pole, 415 V, with Microprocessor release 250 Amps with breaking capacity 36 KA for APFC panel
Supply and fix double compression copper stain less steel gland for fixing armoured cable in panel of 3½core 300 sq mm size complete all as specified and directed
Supply and fix double compression copper stain less steel gland for fixing armoured cable in panel of 4 core 16 sq mm size complete all as specified and directed
M&L for PCC plateform along with chain link fencing for Transformer complete with steel gate as per TD Drawing complete all as specified and directed
Supply, laying & testing of HT Cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) with stranded aluminium conductor, 11000 volts, grade cross setional area 95 sq mm, 3 core complete all as specified and directed
Supply, laying & testing of LT Cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) with stranded aluminium conductor, 1100 volts, grade cross setional area 300 sq mm, 3.5 core complete all as specified and directed
Supply, laying & testing of LT Cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) with stranded aluminium conductor, 1100 volts, grade cross setional area 16 sq mm, 4 core complete all as specified and directed
Supply and laying/fixing GI tubing light grade for cable protection of size 50 mm dia all as specified and directed.
Supply and laying/fixing GI tubing light grade for cable protection of size 80 mm dia all as specified and directed.
Material and labour for cable jointing kit for 11KV(Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 - 95 Sqmm 3 core complete all as specified and directed
Supply and fix cable jointing kit for 1.1 KV grade cable for termination joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 300 sqmm ,Indoor/Outdoor type complete all as specified and directed
Earth continuity conductor or main earth lead fixed to walls or recesses in chasiss or buried in ground or drawn in conduit pipe or any indicating situation using galvanised iron strip of size 32 x 6 mm complete all as specified and directed
M & L for Rubber mat of 1mtr X 2mtr X 10 mm thick complete all as specified and directed.
Material and labour in repair for earthing complete with galvanized earth plate electrode in 60 cm x 60 cmx 6 mm thick buried directly in ground vertically at a depth not less than 2.25 meter below ground level with top edge of earth plate at depth not less than 1.5 mtr below ground level connecting to and including GI strip 32 mm x 6 mm by means of GI bolts, nuts, check nuts and washer light grade 40 mm dia GI protection pipe and connected to equipment, GI pipe medium grade 20 mm dia for watering an including funnel wire mesh, RCC pit cover and PCC 1;2:4 type B-1 including Rocksalt, charcoal, excavation and earth work disposal of surplus soil shown as plate No 3 of SSR Part - I 2009 and all as specified complete. Note : - The unit rate quoted shall deemed to have included for GI protection pipe, GI earth strip up to 7.5 mtr, GI water pipe, wire mesh , funnel , excavation, RCC pit cover complete.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore GI med grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 incl dismantling of old unsv existing earthing .
Supply and fix horizontal single mounting siren, SS-200, single phase 220/250 V, 6000 RPM, 50 Hz AC having motoer rating of 1/4 HP and 2.0 Kms range complete all as specified and as directed. Make ; Kheraj
M/L for fabrication and fixing canopy made out of 40x40x6 mm angle iron and 2 mm thick sheet steel conforming to Fe.290.Gde-E-165 having size of 75x75x60 cm and slope of 10 degree, mounted on roof top with the help of fastners, nut, bolt, washer etc for protection of siren
M&L Sub main wiring with two single core PVC sheathed insulated cable of 2.5 sqmm size copper multi strandred conductor 1100 volts grade drawn-through and including 20 mm dia rigid PVC conduit of adequate size and conduit and junction boxes, terminal boxes and accessories such as tees. bends elbows, reducers, bell mouth tube ends fixed in wall surface with saddles screwed to walls including one run of 2.5 sqmm copper conductor unsheathed multi stranded earth wire earth continuity conductor. (Two runs of single core cable and one run of 2.5 sqmm copper wire earth continuity conductor and conduit with accessories shall be measured as one length) complete all as specified.
Supply and fix MCB SP 6-32 Amps 'C' curve, 10 KA in existing DB complete all as specified
Supply and fix single phase 230 v, 50 Hz starter of 20 Amp rating including grouting on wall with fastners, nuts, bolts and washers etc complete all as specified.
Supply & fix decorative cast iron light post with twin luminairs arranged at 180 degree angle having 3 mtrs height, all forms true to the pattern/mould with decorative embellishments with 3 nos. of hot dip galvanized type anchor bolts, duly painted with standard colour that is close to characteristic tone of cast iron with Polyurethane paint for a longer service life including luminaires 02 Nos with 12 Watt LED lamps and connectors for incoming/outgoing connections and fixing on PCC foundation complete all as specified. Note: PCC for foundation shall be measured and paid in separate item of BOQ.
Supply and fixing Cone NXG IP 65 bollard light having 1mtr height and 9 W LED with aesthetic touch, innovative design with uniformly lit diffuser at the upper portion including connectors for incoming/outgoing connectctions complete all as specified. Make: Havells, Model: CONENXGBLS8WLED830PSYMTOPCM (1.0 M) or euivalent model of bajaj/philips/C&S
Supply and fix MCB SPN 32 Amps 10 KA in existing LT Panel complete all as specified.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor, stranded served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm nominal cross section, 3 core complete all as specified
Supply and fixing Rigid non-metallic PVC conduit 25 mm bore for passing of cable exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories complete all as specified & directed.
Supply& Fixing GI pipe light grade 40 mm dia bore for crossing under roads.complete all as specified & directed.
M & L for PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) in coping for electric poles or for stay assy etc. complete all as specified and directed .
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in condiut/pipe or fixed on poles or any other indicated situation for loop earthing as required with 4mm dia GI wire complete as specified & directed
M & L for rendering 15mm thick in CM 1:4 in two layers (10 +5mm) finished even and smooth (without using extra cement) using integral water proofing compound. Note: Integral water proofing compound shall be measured and paid seperatly under relevant item
SHREE MOMAY CONSTRUCTION
Venus Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .