Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 CrAccepted-AOC 583 URBAN ESTATE II HISAR 125005 | HISAR | HISAR | HARYANA | 125005 | ₹14.0 Cr Quoted ₹14.6 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹15.1 CrRejected-Finance | ₹15.1 Cr | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹15.4 CrRejected-Finance | ₹15.4 Cr | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹15.7 CrRejected-Finance | ₹15.7 Cr | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹17.2 CrRejected-Finance | ₹17.2 Cr | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹9 L
Closing Date
18 Oct 2022, 6:00 pmClosed
Chief Engineer Delhi Zone
HQ Chief Engineer Delhi Zone, Delhi Cantt-10
PROVN OF SAILORS MARRIED ACCOMMODATION (40 DUS) (K-BLOCK) AT CHANAKYABAGH NEW DELHI
2022_MES_511585_3
CA No CEDZ/TOKEN-13 OF 2022
Open Tender
Civil Works
540 days
Delhi Cantt
MES contractor enlisted in MES under class S cat a i having deposited Standing Security of Rs 1100000.00 with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹3,000
GE New Delhi
₹9 L
Yes
25 Mar 2023
14 Sept 2022
20 Oct 2022
14 Sept 2022
18 Oct 2022
28 Sept 2022
14 Sept 2022 - 26 Sept 2022
Amount
INTERNAL WATER SUPPLY S & F 15 mm bore angular stop valve, half or quarter turn, cast copper alloy chromium plated all as specified and directed.
S&F 15mm bore health faucets fancy type chromium plated ABS body with 1 meter SS braided conection pipe complete all as specified and directed.
S&F in repair CP Wall mixer (wall mounted model) 3-1 system (Code: Jaquar VTG-9281 or equivalent from approved list of makes of E-in-C's branch and as approved by GE.) with provision for telephonic shower and overhead shower complete with 115mm long pipe connecting legs and flanges. Hand shower (Code : HSH-1721 or equivalent from approved list of makes of E-in-C's branch and as approved by GE.) 105mm dia round shape multi flow with air effect (ABS body & face plate chrome plated) with rubbit cleaning system and over head shower 105mm dia round shape single flow (ABS body chrome plated with gray face plate) with rubbit cleaning system Code (Code : OHS-1709 or equivalent from approved list of makes of E-in-C's branch and as approved by GE) and with shower arm 20mm x 600mm long round shape for wall mounted shower with flange complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY S&F LED Tube Light of 20/22 Watt 230Volt(size 4 ft) , box type complete with LED Tube Light 20 Watt & all accessories internally prewired including connecting up with three core sheathed flexible copper conductor cable of suitable size complete all as specified.
S&F in LED Tube light fitting 10 watt ( 2 ft ) white 230 Volt AC complete including connecting up with three core twisted flexible copper conductorr cable all as specified.
Supply and fixing aesthetically designed Wall mounted decorative wall LED light of 9 W fixture with opal diffuser to give glare free light including suitable LED lamp of 8 W having Lamp base E27 complete all as specified and directed.
Supply and fixing aesthetically designed Wall mounted decorative mirror LED light of 3.6 W fixture with opal diffuser to give glare free light including suitable LED lamp of 3.6 W having Lamp base E27 complete all as specified and directed.
S &F of 2x2 Panel light surface mounted LED light of 36 W fixture with opal diffuser to give glare free light including suitable LED light of 36 W complete all as specified.
Supply and fixing aesthetically designed Wall/Ceiling mounted decorative downlighter LED light of 12 W fixture with opal diffuser to give glare free light including suitable LED lamp of 12 W complete all as specified.
Supply and fixing of Building security light fitting 25 watt outside the building including GI bracket of suitable size,fixing with clamp all as specified & directed
Supply and fixing ceiling fan 5 star rating (Opal white) economy range high speed having full copper motor & ribbed alluminium blades for higher air delivery,power coating provides longer life complete with accessories 230 volts 1200 mm sweep,300 RPM with air delivery 255/265 Cum/min including making arragement to hanging of fan to ceiling with proper hook nut bolts complete all as specified & directed
Supply and fixing Exhaust Fan 300 mm Sweep, 240 Volt, AC 50 HZ , Metal body, heavy duty including lovers with and including cutting bricks/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement morter complete all as specified and directed
Supply and fixing Exhaust Fan 230 mm Sweep, 240 Volt, AC 50 HZ , PVC body , heavy duty including louvers with and including cutting bricks/stone boulders wall for fixing of fan and finished the cutting surface even and smooth by using cement morter complete all as specified and directed.
S&F AC single phase static energy meter of accuracy class 1.0, 240 V, 50 Hz with Backlit LCD display of rating 5 - 30 A, (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box complete all asspecified and directed.
S&F AC three phase static energy meter of accuracy class 1.0, 415 V, 50 Hz with Backlit LCD display of standard rating , (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box complete all asspecified and directed.
S&F HOT press moulded SMC Meter box of inside dimensions 250x150x155 mm with hinged doors and all accessories required for fixing 01 nos single phase digital electronic meter complete all as specified and directed
Supply, Installation, testing & commissioning factory made and tested (incl CPRI type test certified) LT pillar box (KIOSK) outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, haing bus bar chamber with insulated copper bus bar 525 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15 CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder caoted finish over one coat of red oxide primer outside and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable Is 694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:_ (LT Feeder Pillar)
Supply and laying on wall with proper fixture or using cable tray of size 16 sqmm x4 core XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor complete all as specified and directed
S&F VTPN DB's 415 Volts, IP-43, with MCCB 63 AMP, 4 pole as incommer, 4 way with 200 Amps rated copper bus bar double door type complete all as directed
AREA DRAINAGE S&F Factory made steel fibre reinforcement concrete (SFRC) cover of medium duty 70-75mm thick with perforated holes 50mm dia and set in CM 1:6 complete all as specified.
RAIN WATER HARVASTING SYSTEM M&L for drilling 250 mm dia borehole by DTH cum Rotary at any depth below the ground level in any kind of rock/soil up to 40 m depth including disposal of surplus soil to a distance not exe 50 mtr away all as specified and directed.
S&F self preforted unplasticised PVC pipes 250 mm dia of pressure rating 10 kg/Sqcm fixed complete to wall or ceiling or in floors complete all as specified.
EXTERNAL WATER SUPPLY Supply , laying jointing testing ductile iron pipe with spigot socketed ends class K-9 conforming to IS 8329 with inside cement mortar lining laid in trenches of 100mm bore size complete including joints and jointing materials suitable for DI pipes all as specified and directed
Supply , laying jointing testing ductile iron pipe with spigot socketed ends class K-9 conforming to IS 8329 with inside cement mortar lining laid in trenches of 80mm bore size all as specified and directed
EXTERNAL ELECTRIC SUPPLY Supply installation testing and commissioning factory made and tested (incl CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type plateform mounted suitable for 415 volts 3 phase 4 wire 50 Hzs AC supply system having bus bar chamber with insulated aluminium bus bar 500 Amps rating installed on porcelain insulators. The panel shall be dust and virmin proof IP 65 protection and made of 3.15mm CRCA MS sheet and 40x40x6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, front opening type with provisions for cable entry with double door shutter and locking arrangement including provision of 65mm godrej freedom lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The shouild be suitable for housing in and including the following :-
(a) INCOMING :
(i) MCCB 4 pole 320 Amps 50 KA rating capacity - 01 No
(iv) CTs with ratio 400/5 class ISI marked - 01 Set of three
(v) LED type indicating lamp (R.Y.B) - 01 Set of three
(b) OUTGOING
(i) MCCB 4 pole 415 volts 250 Amps rating and repturing cap 35 KA - 02 No (incl 1 spare)
(J) MCCB 4 pole 415 volts 63 Amps rating and repturing cap 25 KA - 02 No (incl 1 spare)
(k) MCB DP 32Amps with astronomical timer and 32 A contactor etc complete for street light-01 Set
Supply installation testing and commissioning factory made and tested (incl CPRI type test certified) LT feeder pillar box (KIOSK) indoor type plateform mounted suitable for 415 volts 3 phase 4 wire 50 Hzs AC supply system having bus bar chamber with insulated aluminium bus bar 600 Amps rating installed on porcelain insulators. The panel shall be dust and virmin proof IP 65 protection and made of 2 mm CRCA MS sheet and 40x40x6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside, front opening type with provisions for cable entry with double door shutter and locking arrangement including provision of 65mm godrej freedom lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The shouild be suitable for housing in and including the following :-
(a) INCOMING :
(i) MCCB 4 pole 400 Amps 50 KA rating capacity - 01 No
(iv) CTs with ratio 400/5 class ISI marked - 01 Set of three
(v) LED type indicating lamp (R.Y.B) - 01 Set of three
(b) OUTGOING
(i) MCCB 4 pole 415 volts 320 Amps rating and repturing cap 50 KA - 02 No ( Incl one spare)
S&F LED street light fitting 1x45 Watt IP-65 complete with fixing bracket of suitable size GI pipe light grade not less than 1 mtr length, connection wire from pole box to light fitting of 2x1.5 sqmm and 1 x 1.5 Sqmm as earth wire in steel conduit as required complete in all respect as directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
FIRE FIGHTING & FIRE ALARM SYSTEM Supplying, erecting &commissioning following Fire cabinet:-
a)Supplying and fixing single headed internal hydrant valve with instantaneous gun metal /SS coupling of 63 mm dia with cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal cap and chain as required.
b)Providing and installation of 63 mm dia,2 X15 Mtr long rubber lined woven jacketed hose pipe, type- A (Reinforced rubber lined) of IS636-1988 complete with necessary instantaneous spring lock type coupling at the ends to match with landing valve / hose pipe / branch pipe with gunmetal/SS male & female couplings (IS:903:1993)(Make : PADMINI/OMEX/TORRENT)
c)1no gun metal branch pipe with nozzle (63mmx20mm) with Gun metal gate/ ball valve (20mm)
d) Two keys in recess type compartment for break glass
e) Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post Office Red drum and brackets, Conforming to IS 884 with upto date amendments, complete with the following as required. (a) 30 m. long 20 mm (nominal internal) dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585 (b) Drum and brackets for fixing the equipments on wall, Connections from riser with 25 mm dia stop valve & M.S. Pipe (c ) branch pipe with nozzle of 20 mm for hose reel conforming to IS-8090
f)The double door with frame of size 1000mm X 1650mm made of 18 gauge ,4mm inside glass painted red.
DG SET Supply, installing, commissioning and testing complete of Manufacturer or OEM (Original Eqpt Manufacturer) manufactured and tested silent Diesel Engine driven generating set capable of delivering 40 KVA (32 KW),or nearest higher rating 415 volts (AC 3 Phase, 4 wire system of supply), 50 Hz to operate at a powers factor of 0.8. The DG set shall consist of a diesel engine coupled through flexible coupling to a matching alternator and mounted on AVM pads (As per respective Mnufacturer Design ) on a common base frame all as specified complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete and shall comprise of the following: -
(a) ENGINE (PRIME MOVER): Diesel engine 1500 RPM of suitable HP as recommended by manufacturer but not less than 43 BHP (at NTP) water cooled, Turbocharged aircooled, 1 x90 AH 12 volts electric battery start, confirming to BS 5514,BS 649 and IS 10000 complete with fly wheel and all standard fittings/ fixtures as per manufacturing practice including suitable engine control panel with tachometer, lub oil temp & pressure gauges, water temp gauge, and frequency meter (digital type) (including safety shutdown contents) and also including self starter, dynamo, fuel tank etc.
(b) ALTERNATOR : AC alternator, self excited, self regulated, self ventilated, brushless design, conforming to BS 2613 / 5000, 3 phase , 415 volts, 4 wire rated line current 45 amps for output PF 0.8, 1500 RPM, insulation class ‘H’ Temprature Reise H @ 40 Deg C; Enclosure IP 23 confirming to IS-4722 / BS-2613 complete with AVR with + 1 % voltage regulation, directly coupled to and match the above engine.
(c) Anti-vibration pads for mounting engine – alternator assembly on the base frame/ plate.
(d) BASE FRAME:One no. MS Fabricated adequately machine Channel Common Base Frame with lifting facility,pre-drilled foundation holes suitable for permanent installation on concrete foundation for direct grouting or on anti-vibration mountings which will be suitable to receive the offered engine and alternator duly coupled through a flexible coupling. A suitable coupling guard shall also be provided
(e) Silencer: Critical Grade and exhaust gas piping system of suitable dia MS pipe of 'B' class of required legth as per CPCB norms with necessary bends, supports and clamps anti vibration mounting inulated with rockwool 50 mm thick with wire mesh and aluminium clading complete all as specified
(f) Fuel tank of 100 Litres/specified by the manufacturer, made of 14 SWG CRCA MS sheet, duly powder coated and provided with float, gauge and fuel float switch.
(g) Emission limit & smoke limit for DG set shall be as per CPCB norms applicable at the time of execution.
AMF Panel:-
Fabricating, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 40 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyzer to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including for following:
MCCB 63 Amps. 4 Pole
(a) 2 Nos over voltage relay, 2 Nos reverse power relay and 2 Nos under voltage relay.
(b)3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering
(c) Energy analyzer unit to indicate current voltage frequency power factor and KWH
(d) Indicating lamps for load on mains and load on set
(e)Fuse for instruments
(g) Main supply failure monitor
(h) Supply failure timer
(i)Restoration timer
(j)Control unit with three impulse automatic engine start/ stop and failure to starty lockout
(l) Impulse counter with locking and reset facility
(i) Audio/ Video annunciation for
(ii) High water temperature
(iii) Low lubricating oil pressure
(iv) Engine over speed
(v) Engine fails to start
(vI) Full load/ maximum load warming
(a) LED Light Ultra slim decorative aluminium casted, recess mounted square fixture in white with opal diffuser and separate electronic driver, suitable for low depth ceiling -12W BLAZE SQUARE with complete accessories including necessary wiring - 04 Nos. Make:- Havells (cat part no. LHEBMFP6IZ2W012) or equivalent model in CG/Philips.
(b) Single phase centrifugal type cross flow blower 270 cu meter/hour-02 Nos.
(c) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per as Per IS(minimum efficiency class equivalent to IE 2 and operating gearless box with independent main sheave rim.
(d) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size
(e) Micro processor based VVVF type main controller with closed loop system.
(f) Type of signal system FIGS fixtures with dot matrix display and car position indicator in car all fixture in SS face plate (both insided/out-side).All Buttons should be with brail marking and luminous.
(g) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking, connect to complete cell and provn of through & other accessories.
(h) IInbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside the lift car to alert the persons trapped inside they are being rescued.
(j) Provision of governor grooved belt and along with belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator to nearest landing of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology.
(k) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches.
(l) Door Sensor not less than 74 beam, 2D infra red full length.
(m) Provision of fire man switch complete at ground floor fitted in box including SS face plate.
(n)Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown
(o) Do's & Don’ts chart on stainless steel to be installed inside the car cabin.
(p)A three Pin plug socket with switch for hand lamp shall be fitted top of the lift car for use by person working there on.
(a) LED Light Ultra slim decorative aluminium casted, recess mounted square fixture in white with opal diffuser and separate electronic driver, suitable for low depth ceiling -12W BLAZE SQUARE with complete accessories including necessary wiring - 04 Nos. Make:- Havells (cat part no. LHEBMFP6IZ2W012) or equivalent model in CG/Philips.
(b) Single phase centrifugal type cross flow blower 270 cu meter/hour-02 Nos.
(c) Electrically operated with electric motor AC 415 Volts, 3 Phase 50 HZ of suitable capacity as per as Per IS(minimum efficiency class equivalent to IE 2 and operating gearless box with independent main sheave rim.
(d) Electric cabling and wiring in FRLS copper cable including all necessary PVC conduits ISI marked of suitable size
(e) Micro processor based VVVF type main controller with closed loop system.
(f) Type of signal system FIGS fixtures with dot matrix display and car position indicator in car all fixture in SS face plate (both insided/out-side).All Buttons should be with brail marking and luminous.
(g) Provn of travelling cable with copper conductor FRLS of suitable size & core or required wiring to intercom speaking, connect to complete cell and provn of through & other accessories.
(h) IInbuilt ARD (Automatic Rescue Device) with maintenance free batteries operated to bring the car cage to the nearest floor level in case of power failure, which includes power failure of one or more phase. Emergency light and at least one fan inside the lift car shall be operational till the rescue operation and an audio and visual indicator shall be provided inside the lift car to alert the persons trapped inside they are being rescued.
(j) Provision of governor grooved belt and along with belt monitoring device which can ensure to prevent from any breakage of belt and taking elevator to nearest landing of suitable size, buffer springs as per manufacture's design, car cabin having powered doors and inspection box at top of the car cabin, compact high efficiency drive combined with suspension Traction Media Technology.
(k) Provision of safety guarding equipments such as 02 Nos pit switches controller, guarding pit, pulley, guarding pit ladders, facia plate to cover free space between car cabin and hoist way & switches.
(l) Door Sensor not less than 74 beam, 2D infra red full length.
(m) Provision of fire man switch complete at ground floor fitted in box including SS face plate.
(n)Provision of "Press and Speak" system to be connected with lift complaint cell compatible with exchange. Provision of Automatic call registration in case of breakdown
(o) Do's & Don’ts chart on stainless steel to be installed inside the car cabin.
(p)A three Pin plug socket with switch for hand lamp shall be fitted top of the lift car for use by person working there on.
AVIATION LIGHT S & F Aviation obstruction light (Twin) aviation Yellow painted die cast Al alloy housing, red coloured polycarbonate dome and accessories suitable for LED 2x6 watt complete all as specified and directed.
HOT WATER SUPPLY S & F electric water heater storage type steel body with copper innner tank and heating element upto 2 KW capacity 25 Ltr, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
DEMOLITION AND DISMANTLING Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work or any type complete all as specified and directed.
Description of Work / Item(s)
Amount
Total amount of Sch 'A' Section I (Building work) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section I)
Total amount of Sch 'A' Section II (Internal Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section II)
Total amount of Sch 'A' Section III (Internal Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section III)
Total amount of Sch 'A' Section IV (Area Drainage) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IV)
Total amount of Sch 'A' Section V (Sewage Disposal) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section V)
Total amount of Sch 'A' Section VI (Road, Path & Culvert) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VI)
Total amount of Sch 'A' Section VII (Compound wall, fencing & Gate) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VII)
Total amount of Sch 'A' Section VIII (Rain Water Harvesting System) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VIII)
Total amount of Sch 'A' Section IX (External Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IX)
Total amount of Sch 'A' Section X (External Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section X)
Total amount of Sch 'A' Section XI (Fire Fighting E/M WORKS) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XI)
Total amount of Sch 'A' Section XII (DG Set) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XII)
Total amount of Sch 'A' Section XIII (Lift) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIII)
Total amount of Sch 'A' Section XIV (LIGHTENING PROTECTION) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIV)
Total amount of Sch 'A' Section XV (Demolition & Dismantling) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XV)
Total amount of Sch 'A' Section XVI (Excavation, Earth work & Site Clearance) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XVI)
Global Enterprises
M/s Innovative Coolings and Constructions
AMIT ASSOCIATES
Siya constructions
Global Enterprises
M/s Innovative Coolings and Constructions
Saraogi Infrastructure
AMIT ASSOCIATES
Bidder Name
AMIT ASSOCIATES
Global Enterprises
M/s Innovative Coolings and Constructions
Siya constructions
Saraogi Infrastructure
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid