| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER. | |
| 2 | L2₹24.8 L+₹2.3 L (10.2%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER. | |
| 3 | L3₹25.7 L+₹3.2 L (14.3%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L3 | Rejected-Finance NOT THE LOWEST TENDERER. | |
| 4 | L4₹28.5 L+₹6.0 L (26.6%)Rejected-Finance FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L4 | Rejected-Finance NOT THE LOWEST TENDERER. | |
| 5 | L5₹29.0 L+₹6.5 L (28.8%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L5 | Rejected-Finance NOT THE LOWEST TENDERER. |
| Sl No | Description | Qty | Unit | PURVA ELECTRICALS AND ENGINEERS L2 | SKS Electricals L7 | Aziz Traders L6 | TRINSIYA ASSOCIATE L1 | ONKAR ELECTRIC AND GENERAL STORE L5 | Adinath Technical Services L3 | Chaulya Enterprises L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install, testing and commissioning in repair factory made out door type LT panel board of size not less than 1.5 mtr X 1mtr X 0.300 mtr, 440 volts , 3 phase , 4 wire system with powder coating provided to make it dust /vermin proof manufactured by CPRI approved manufacturer. The panel shall be made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 1.6 mm thick CRCA sheet,double door with front openable with locking arrangement, provision of threaded earthing stud at bottom, inner shell be compartmentalized, front openable single door system lockable. Inner shell completely vermin proof and to accommodate incoming/outgoing MCCBs, MCBs, and TPN aluminium bus and extension links. Aluminium bus bar of capacity 600 Amps- 4Nos, including neutral duly insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size/rating of epoxy resin insulator all housed in suitable bus bar chamber. All control wires shall be as per the OEM recommendations and shall be properly bunched,tied, ferrulled for proper indentification and crimped with adequate size of lugs and provision and fixing of Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable size of cable glands etc. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete all as specified and directed. The panel shall consists of following accessories:- | 1 | Each Job | 1,10,000 ₹1,10,000 | 1,65,000 ₹1,65,000 | 1,85,000 ₹1,85,000 | 1,21,000 ₹1,21,000 | 92,000 ₹92,000 Lowest | 1,82,718 ₹1,82,718 | 1,50,000 ₹1,50,000 |
| 1.01Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 50mm x 50mm x 6mm with bottam of panel having minimum 60cm height from existing ground/floor level. | ||||||||||
| 1.02Aluminium bus bar strips with proper colour code - 04 No, 600 A capacity, insulator, nuts bolts etc complete. | ||||||||||
| 1.03Indicator Lamp-01 Set (Set of three) | ||||||||||
| 1.04Incommer MCCB 4P 250 Amp, 415V, 36 KA Ics = 100 Icu Adjustable type - 01 No | ||||||||||
| 1.05Outgoing, MCCB 4P 125 amp, 415V, 25 KA Ics = 100 Icu Adjustable type - 01 No | ||||||||||
| 1.06Outgoing, MCCB 4P 100 amp, 415V, 25 KA Ics = 100 Icu Adjustable type - 03 No | ||||||||||
| 1.07MCB TPN 32A,10KA B curve - 01 Nos for Street light panel | ||||||||||
| 1.08Digital Voltmeter 0 to 500 V and Digital Ampmeter 0 to 400A. with selector switich Make-Legrand/Minilac | ||||||||||
| 1.09Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles. | ||||||||||
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
13 Mar 2026, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPAIR REPLACEMENT AND SERVICING OF LT PANEL BOARDS AND LT NETWORK SYSTEM AT AC PLANT LOCATIONS UNDER AOR OF GE MH AND RH KHADKI
2026_MES_753552_1
8854/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹70,000
28 Mar 2026
20 Feb 2026
16 Mar 2026
20 Feb 2026
13 Mar 2026
6 Mar 2026
20 Feb 2026 - 13 Mar 2026
Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 50mm x 50mm x 6mm with bottam of panel having minimum 60cm height from existing ground/floor level.
Aluminium bus bar strips with proper colour code -04 No, 400 A capacity, insulator, nuts bolts etc complete.
Indicator Lamp-01 Set (Set of three)
Incommer MCCB 4P 250 Amp, 415V, 36 KA Ics = 100 Icu Adjustable type - 01 No
Outgoing, MCCB 4P 125 amp, 415V, 25 KA Ics = 100 Icu Adjustable type - 01 No
Outgoing, MCCB 4P 100 amp, 415V, 25 KA Ics = 100 Icu Adjustable type - 03 No
MCB TPN 32A,10KA B curve - 01 Nos for Street light panel
Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles.
Note : (i) Electrical connection from switchgear to bus bar would be through copper cable of suitable size. (ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1 (using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 50mm x 50mm x 6mm with bottam of panel having minimum 60cm height from existing ground/floor level.
Aluminium bus bar strips with proper colour code -04 No, 500 A capacity, insulator, nuts bolts etc complete.
Indicator Lamp-01 Set (Set of three)
Incomer MCCB 4P 250 amp with thermal magnetic release , 415V, 36 KA - 01 No Make Legrand cat no-4220 49 //Havells
Outgoing, MCCB 4P 100 amp with thermal magnetic release , 415V, 25 KA - 02 No (for Distribution panel) Make Legrand cat no-4200 52/Havells
Outgoing, MCCB 4P 63 amp with thermal magnetic release , 415V, 25 KA - 03 No (for Distribution panel) Make Legrand cat no-4200 53 /Havells
Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles.
Supply, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable in repair with stranded aluminium conductor 1100 volts grade confirming to IS-7098 (Part-I-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, PVC sleeve etc including dismantling of old LT UG cables complete all as specified and directed for following sizes . Make :- Havells / Gloster / Finolex / Polycab
300 sq mm 3.5 core .
240 sq mm 3.5 core
150 sq mm 3.5 core
95 sq mm 3.5 core
70 sq mm 3.5 core
50 sq mm 3.5 core .
35 sq mm 3.5 core
25 sq mm 3.5 core
16 sq mm 4 core
NOTE :- Earth work , bricks , riddled earth , GI pipe for protection of cable will be measured & paid under under relevant items of schedule .
Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size 25 Sqmm to 50 Sqmm 3.5 core/4 core cable complete all as specified and directed.
Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size from 70 Sqmm to 120 Sqmm 3.5 core /4 core cable complete all as specified and directed.
Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size from 150 Sqmm to 185 Sqmm 3.5 core/4 core cable complete all as specified and directed.
Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size from 240 Sqmm to 300 Sqmm 3.5 core/4 core cable complete all as specified and directed.
Supply and Fixing in repair of double fitted polymer fabric HDPE fresh air filter(Filter class-G3 as per EN 779) washable/cleanable type having efficiency 95% to 99% down to particle size of 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, of make Thermadyne/ Pall supralon filter / Micron filter complete all as specified and directed of following sizes :-
600 mm x 500 mm x 45mm
600 mm x 600 mm x 45mm
600 mm x 400 mm x 45mm
500 mm x 500 mm x 45mm
500 mm x 400 mm x 45mm
Supply and Fixing in repair of double fitted polymer fabric HDPE fresh air filter(GL-type) washable/cleanable type having efficiency 95% to 99% down to particle size of 5 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, including taking down of make Thermadyne/ Pall supralon filter / Micron filter complete all as specified and directed of following sizes :-
600 mm x 500 mm x 300 mm
600 mm x 600 mm x 300 mm
600 mm x 400 mm x 300 mm
500 mm x 500 mm x 300 mm
500 mm x 400 mm x 300 mm
500mm x 400 mm x 300 mm bag type filter 5 micron
Supply and Fixing in repair of filter "HEPA"(EN-1882) with fibre glass paper filtering media capacited 1000 CFM efficiency 99.97% down to particle size of 0.3 to 0.5 micron aluminium frames box type of size 500x400x300mm including taking down of make Thermadyne/ Pall supralon filter / Micron filter complete all as specified and directed.
Supply and fix in repair MCCB of following capacities complete all as specified and directed:- Make : L & T/Legrand/ABB/Havells
400A,TP.415V,50 Hz, 36 KA adjustable type, ics=100%icu
250A,TP.415V,50 Hz 36 KA adjustable type, ics=100%icu
160A,TP.415V,50 Hz 36 KA adjustable type, ics=100%icu
125A,TP.415V,50 Hz, 25KA adjustable type, ics=100%icu
100A,TP,415V,50Hz,25KA , ics=100%icu
63A,TP,415V,50Hz,25KA , ics=100%icu
40A,TP,415V,50Hz,16KA , ics=100%icu
32A,TP,415V,50Hz,16KA , ics=100%icu
Supply and fixing 415 Volt 10 kA 'C' curve MCB of TP upto 100 Amps and current carrying capacity in the DB \ Panel complete all as specified and directed. Make : L & T/Legrand/ABB/Havells
Supply and fix in repair of contactor of following capacities suitable for existing of panel and sample complete all as specified and directed. Make : L & T, Seimense, Legrand
70A, TP with 2 NO + 2 NC
3TF 52 with 2 NO + 2 NC
3TF 54 with 2 NO + 2 NC
Supply and fix in repair of over load relay following capacities suitable as per the existing sample complete all as specified and directed. Make : L & T, Seimense, Legrand
MN5 of rating 20A to 33A
MN5 of rating 30A to 50A
MN5 of rating 14A to 23A
MN5 of rating 9A to 15A
MN5 of rating 6A to 10A
MN5 of rating 4.5A to 7.5A
Supply and fix in repair of Fuse holder Suitable for Bolted fuse-links rating 20 Amp suitable as per site requirement complete all as specified and directed. Make : L & T, Seimense, Legrand
Supply and fix in repair of Bolted fuse links SG BS type rating 2 Amp to 20 Amp suitable as per site requirement complete all as specified and directed. Make : L & T, Seimense, Legrand
Supply and replace unservisable/rusted blower motor base plate of MS sutiable for 5 HP and 3 HP as per site requirment all as directed the cost of fabrication work for fixing the base plate is included in the cost complete all as specified and directed.
Supply and Replacement AHU blower DIDW fan blower having out velocity not exceeding S.P.(mm/wg) 50 to 60 m/s energy efficent fan with double inlet , double with forward or backward curved impeller for high static pressure mounted on aluminum extended side rail base frame, and to be fitted on the existing AHU for following complete all as specified and directed: Make:Kruger (MH Phase -1 Central AC Plant)
Model : BDB-250-CM D20
Model: KAT "9/9" S D20
Supply and Replacement AHU blower DIDW fan blower having out velocity not exceeding S.P.(mm/wg) 50 to 60 m/s energy efficient fan with double inlet , double with forward or backward curved impeller for high static pressure mounted on aluminum extended side rail base frame, existing AHU of following capacity of Blowers motors ( Phase - 2 Central AC Plant) complete all as specified and directed :-
Blower for Capacity 5 HP motor Make- as per site requirement
Blower for Capacity 3 HP motor Make- as per site requirement
Supply & fixing, testing and commissioning of ACB 4 pole, 415 Volts, 630 Amps, 50KA Manual Draw out type with microprocessor based LSIG & inbuilt temprature rise protection consisting of digital LCD display with battery back up,Current Metering and RS 485 Port. conforming to IS/IEC 60947-2 complete with all accessories , including dismantling old ACB from the existing panel, complete all as specified and directed. Make :- Legrand/Havells/ABB/L&T
Supply & fixing, testing and commissioning of ACB 4 pole, 415 Volts, 800 Amps, 50KA Manual Draw out type with microprocessor based LSIG & inbuilt temprature rise protection consisting of digital LCD display with battery back up,Current Metering and RS 485 Port. conforming to IS/IEC 60947-2 complete with all accessories , including dismantling old ACB from the existing panel, complete all as specified and directed. Make :- Legrand/Havells/ABB/L&T
Supply & fixing, testing and commissioning of ACB 4 pole, 415 Volts,1000 Amps, 50KA Manual Draw out type with microprocessor based LSIG & inbuilt temprature rise protection consisting of digital LCD display with battery back up,Current Metering and RS 485 Port. conforming to IS/IEC 60947-2 complete with all accessories , including dismantling old ACB from the existing panel, complete all as specified and directed. Make :- Legrand/Havells/ABB/L&T
Dismantling and taking out old AHU unit from the room and Supply, Install, Testing and commisiong by OEM new AHU unit with blower motor 7.5 hp and internal coil heater 20 watts and connecting with Inlet and outlet pipe with suitable welding work and refixing the ducting work of the the AHU room complete all as specified by OEM of the AC plant and complete all as specified and directed. Note :- (i) The guarentee of 12 months is to be provide by the the OEM of the AHU Unit for which rates are included in quotated rate. ii) The cost of training to the working staff / operator inclusive in quotated rate. iii) Trial run to be given for at least 72 hours from the changing of the AHU unit . (iv) Contractor has to visit the AC plant and check the AHU room parameters befour quoting the tender. Make:- BLUE STAR/ VOLTAS/ DAIKIN/ CARRIER
Decarbonizing and servicing of LT indoor/outdoor Panel/feeder pillar box of Plant room and AHU rooms any type and cleaning dirt and dust from the panel and removing unserviceable MCCBs, burnt busbars sleeves, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter , replacing burnt, damaged bus bar of any size and fixing proper hanging front and rear openings, welding of hinges including welding of brokieng MS sheet using extra sheets replace burnt thimbles with new existing size thimbles replacing with new MCCB, incluidng dismantling the existing connected cables and re-connecting the same cables, complete all as specified and directed. Note :- (i) The rates are inclusive of any T&P used for cleaning the panels. (ii) The rates inclusive of minor spares ( Nut bolts , washers, insulation sleeves, indicator lamps, CT coils push buttons etc) (iii) Minor fabrication work for reparing the doors ans hinges are included in the quoted cost.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
TENDER8854.pdf
Tender Documents • 0.78 MB
BOQ_844023.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .