Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹31.0 L+₹2.2 L (7.75%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹36.7 L+₹7.9 L (27.5%)Rejected-Finance T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹36.7 L+₹7.9 L (27.5%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹37.8 L+₹9.0 L (31.3%)Rejected-Finance 74 103 DHANKUTTI KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹48.9 L
EMD Value
₹97,850
Closing Date
22 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I Kanpur
GE I Kanpur Cariappa Road Kanpur 208004
REPAIR MAINT OF LT HT NETWORK AND ALLIED WORKS IN COD AND DGQA AREA UNDER GE(I) KANPUR
2020_MES_346003_1
GE(I)/KAN/T-10 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kanpur Cantt
Class D category b i
7 documents required · 7 mandatory
₹500
GE I Kanpur
₹97,850
Yes
10 Jul 2020
19 May 2020
24 Jun 2020
19 May 2020
22 Jun 2020
3 Jun 2020
60 days
Amount
EnM Schedule
Excavation in trenches / foundation in soft / loose soil not exc. 1.5 metre wide and n'exc. 1.5 m deep for under ground cable / pole foundation and getting out including forming bottom surface to required level or slop, complete all as specified and directed .
All as per item No.2 above but depth exc 1.5 mtr but not exc 3.00 mtr
Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft / loose soil, complete all as specified and directed.
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed.
Supply & spreading local sand obtained from ganga river in trenches for cable cushioning 8 cm under and 15 cm over the cable complete all as specified and directed. Note: Punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as speified and directed. Make: Mehtab tiles Indore/Hind Mosaic Tiles Upleta. Note: Purchase voucher and manufacturer test certificate shall be submitted by contractor while claiming payment.
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed..
M&L for cement concrete ( 1:4:8) type D2 using 40mm graded stone aggregate for foundation filling of poles as mass concrete complete all as specified and directed..
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for protection pipe upto 80 mm bore complete all as specified and as directed by Engineer in Charge. Note: Depth of bore shall not be more than 1 Mtr from original ground level.
Taking out carefully unserviceable LT UG cable of size 6 Sqmm to 35 Sqmm from trenches and relaying same after repairs in same or other indicated location and testing complete all as specified and directed. ( Note: Earth work, sand, bricks will be measured and paid separately)
Taking out carefully unserviceable LT UG cable of size 50 Sqmm to 240 Sqmm from trenches and relaying same after repairs in same or other indicated location and testing complete all as specified and directed. ( Note: Earth work, sand, bricks will be measured and paid separately)
Taking out carefully unserviceable HT UG cable of size 70 Sqmm to 185 Sqmm from trenches and relaying same after repairs in same or other indicated location and testing complete all as specified and directed. ( Note: Earth work, sand, bricks will be measured and paid separately)
Disconnecting and taking out existing unserviceable LT Cables of sizes 6 sqmm to 25 sqmm in any position and removing from site complete all as specified and directed by Engineer-in-Charge.
Supply and laying to wall or poles or fixing or passing through pipe, of 1100 volts grade heavy duty cable with XLPE insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 16 sq. mm nominal cross section 2 core Including making good all distributed wall / flooring/tilling surfaces to match with existing specification complete all as specified and directed. Make: Gloster/Havells/ Paragon/ Grandlay/Kalinga.
All as per srl item No 15 above but cable of size 10 Sqmm 2 core.
All as per srl item No 15 above but cable of size 6 Sqmm 2 core.
All as per srl item No 15 above but cable of size 25 Sqmm 2 core.
Disconnecting and taking out existing unserviceable LT Cables of sizes 25 sqmm to 95 sqmm in any position and removing from site complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out existing unserviceable LT Cables of sizes 120 sqmm to 400 sqmm in any position and removing from site complete all as specified and directed by Engineer-in-Charge.
Supply laying , jointing, testing and commissioning of XLPE insulated, PVC sheathed, strip armoured heavy duty electric cable with aluminium conductor (stranded) working voltage upto 1100 volt confirming to IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of aluminium lugs duly crimped with die press crimping device and cable gland of size 25 Sqmm 3.5 core complete all as specified and directed : Make: Gloster/Havells/ Paragon/ Grandlay/Kalinga. Note : 1.Cable laying and jointing are required to be carried out in short / long stretches as per site requirement 2.Necessary excavation and earth work , sand cusioning, cable cover will be measured and paid separately.
All as per srl item No.21 but cable of size 35 Sqmm 3.5 core.
All as per srl item No.21 but cable of size 70 Sqmm 3.5 core.
All as per srl item No.21 but cable of size 95 Sqmm 3.5 core.
All as per srl item No.21 but cable of size 120 Sqmm 3.5 core.
All as per srl item No.21 but cable of size 185 Sqmm 3.5 core.
All as per srl item No.21 but cable of size 400 Sqmm 3.5 core.
S&F in replacement of Cable jointing kit for 1100 volt grade cable for outdoor/indoor termination end joint heat shrinkable type complete with jointing material and accessories with full sleeves and thimbles suitable for XLPE/PVC armoured aluminium conductor cable of size 16 to 35 Sqmm 3.5/4 core complete all as specified and directed. Make : Denson/ M seal/ 3 M.
All as per item No 28 but for 6 to 25 Sqmm size 2 core.
All as per item No 28 but for 50 to 95 Sqmm size.
All as per item No 28 but for 120 to 185 Sqmm size.
All as per item No 28 but for 225 to 300 Sqmm size.
All as per item No 28 but for 400 to 500 Sqmm size.
S&F in replacement of cable jointing kit for 1100 volt grade cable for straight through termination heat shrinkable type complete with jointing material and accessories with full sleeves and thimbles suitable for XLPE/PVC armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5/4 core complete all as specified and directed.Make : Denson/M seal/ 3 M.
All as per item No 34 but for 25 to 50 Sqmm size.
All as per item No 34 but for 70 to 150 Sqmm size.
All as per item No 34 but for 185 to 240 Sqmm size.
All as per item No 34 but for 300 to 400 Sqmm size.
Disconnecting electrically and taking out old unserviceable HT UG cables any type of size 70 Sqmm 3 core and removing from site complete all as specified and directed.
Disconnecting electrically and taking out old unserviceable HT UG cables any type of size 95/120 Sqmm 3 core and removing from site complete all as specified and directed.
Supply, laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with alumn conductor of cross sectional area 70 Sqmm 3 core 11 KV rated suitable for earthed system including testing and commissioning all as specified and directed Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately. Make of cable:- Gloster/ Polycab/ Incab/ Universal/ CCI/Havells
All as per item No - 41 above but HT 11 KV cable of size 95 Sqmm.
All as per item No .41 above but of size 120 Sqmm 3 core 11 KV.
Supply and fix in replacement of cable straight through jointing kit for 11 KV grade cable termination heat shrinkable type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm. Make of cable end box:- Denson/ M seal/ 3 M.
Supply and fix in replacement of cable straight through jointing kit for 11 KV grade cable termination heat shrinkable type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm. Make of cable end box:- Denson/ M seal/ 3 M.
Supply and fix cable end jointing kit for 11 KV grade cable for indoor termination heat shrinkable type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed. Make of cable end box:- Denson/ M seal/3 M.
Supply and fix cable end jointing kit for 11 KV grade cable for indoor termination heat shrinkable type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed. Make of cable end box:- Denson/ M seal/ 3 M.
Supply and fix cable end jointing kit for 11 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed. Make of cable end box:- Denson/ M seal/ 3 M.
Supply and fix cable end jointing kit for 11 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and directed. Make of cable end box:- Denson/ M seal/3 M.
Dismantling unserviceable ACSR conductor, service feeder or distribution span complete and remove from site all as specified and as directed by Engineer in charge.
Dismantling unserviceable earth wire/cradles wire any size from eye hooks/insulators etc from HT/LT over head lines complete and remove from site all as specified and as directed by Engineer in charge.
Dismantling insulators of any type complete for refixing or remove from site all as specified and as directed by Engineer in charge. .
Dismantling unsv cross-arms of M.S. channel or angle sections etc.and remove from site or reuse complete all as specified and as directed by Engineer in charge. .
Dismantling stay assy complete including excavation for taking out PCC block breaking of PCC block for taking out MS plate and removing from site complete all as specified and as directed by Engineer in charge. . .
Disconnecting, dismantling and taking out old steel tubular pole any size/ length complete and remove from site including making good all disturbed surface to match with existing specifications all as directed.
Unbinding from insulators ACSR conductor any size of LT/HT over head line for repairs. Re-stretching of ACSR conductor to achieve proper sag and rebinding to the insulators using alumn/GI binding wire and making all existing cable connections all as required at site.
S&F Aluminium conductor of any size with steel reinforced all as specified and directed .
Supply and fix galvanized steel wire any size to LT over head line as continuous earth or fabrication of guarding cradles all as required at site or directed.
S & F cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia all as spfd and directed .
S & F in replacemet cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-290 (Gde E-165) grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces, supplied and fixed in repair complete all as specified and as directed. (Note : (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge.(ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only. Cost of the same is included in unit rate of the item and nothing extra shall be paid on this account.)
All as srl item No 60 above but fixing only after painting with one coat of aluminium paint. (retrieved against srl item 53 here in before)
Supply, erecting and installation of steel tubular, swaged pole 9 meters long complete with cast iron base plate, finial taper plug, bolts and nuts and screws as specified of type 410 SP-31 conforming to IS-2713-1980 duly painted with two coat of black bituminous paint throughout, internally and externally up to planting depth and painting remaining portion of pole with two coats of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making / pasting three nos circular strips each of 100 mm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking / stencil writing of pole numbers with black paint including necessary excavation & earth work, removing excavated soil from site complete all as specified & directed. Note :- Necessary Excavation and earth work, PCC Work for foundation / erection of pole assembly will be paid separately under respective items.
Supply, erecting and installation of steel tubular, swaged pole 11 meters long complete with cast iron base plate, finial taper plug, bolts and nuts and screws as specified of type 410 SP-31 conforming to IS-2713-1980 duly painted with two coat of black bituminous paint throughout, internally and externally up to planting depth and painting remaining portion of pole with two coats of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making / pasting three nos circular strips each of 100 mm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking / stencil writing of pole numbers with black paint including necessary excavation & earth work, removing excavated soil from site complete all as specified & directed. Note :- Necessary Excavation and earth work, PCC Work for foundation / erection of pole assembly will be paid separately under respective items.
Disconnecting electrically, dismantling from foundation with due care and setting aside old unserviceable LT panel box any type any size with all accessories and removing from site.
Supply and installation, connecting eclectically & commissioning in replacement of LT feeder pillar box outdoor type of size 0.90 x 0.60 x 0.50 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front door open able with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr- 04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 200 amps rated copper bus bar suitable for 3 phase 4 wire supply system duly drilled holes and making all cable connection with proper thimbles mounted on epoxy based post insulators and one MCCB 200 Amps 4 pole 415 Volt, 35 KA of make of MCCB/MCB : Legrand/ Schneider/Havells/L&T complete all as required at site Make of Panel : .Schneider/Havells/L&T/C&S
M&L for stay assy complete with MS stay plate of size 300x300x6mm thick, galvanised stay strand 7/ 3.15 mm , stay rod 16mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I of 1991 or directed by Engr-in-charge ( Excavation, PCC, and loop type insulators will be measured separately).
M&L for loop type insulator large size with overall dimensions 90x140mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified and directed.
Fixing only insulator any type and any size from HT/LT over head lines retrieved from item No 52 here in before complete all as specified and directed.
S&F Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed.
S&F shackle type insulator, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 115mm dia for 1100 volts grade complete all as specified and directed.
Supply & laying in replacement of GI tubing of 80 mm bore dia , light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, CI Pipe line, culvert etc of required length for cable protection complete all as specified and directed.Make: Jindal / Tata / Prakash Surya as approved by GE.
Supply & laying in replacement of GI tubing of 50 mm bore dia , light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, CI Pipe line, culvert etc of required length for cable protection complete all as specified and directed.Make: Jindal / Tata / Prakash Surya as approved by GE.
Supply & laying in replacement of GI tubing of 40 mm bore dia , light grade conforming to IS 1239- Part-I and ISI marked in trenches, across the road, CI Pipe line, culvert etc of required length for cable protection complete all as specified and directed.Make: Jindal / Tata / Prakash Surya as approved by GE.
Supply and fix bus bar chambers 300 mm long iron clad with 4 Nos 200 Amp rated copper strips complete fixed flush wall and making good the disturbed wall surfaces all as a required at site or directed.
S&F in replacement of bus bar chamber with MCB SP 10-16 Amps-01 No outdoor type of size 400 x 380 x 180 mm made out of MS sheet 3mm thick with copper bus bar three phase & neutral each 320 x 20 x 5mm of size fixed with insulators and fixing on pole with proper clamps, nuts , bolts & washers of required size and making connection of LT cables with thimbles and making good the disturbed wall surfaces incl water proof PVC sticker like danger mark all as required at site.
S & F in replacement of in position retro reflective sign board cut to sizes/shape made out of 3 mm thick high density aluminium sheet including writing letter/number with vinyale sheet based of blue colour base by hot process all weather effected fixed on wall with proper arrangement duly riveted all as directed.
S&F in replacement of notice board made out of plywood board with fixing of cloth of best quality green colour supported by aluminium beading complete of size 1 mtr x 1 mtr fixing on wall with necessary arrangement complete all as specified and directed..
Routine and periodical work required for trimming / cutting of tree branches of any girth, touching /obstructing the over head lines of HT/LT poles of three phase distribution system at places not more than 40 mtr span distance so as to keep minimum 2.0 mtr clearance all around the lines and poles with due care after taking proper electric shoutdown from concern MES competent staff complete disposal thereof ( trimmed branches) to a distance not exceeding 100 metre complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 415 Volts 3 phase 400 Amps 36 KA, thermal magnetic release S1 -01 No (incoming). Make : Legrand/Siemens 3WL (ETU45B) / Schneider NW (6.0A)/L&T/ABB /Indo Asian
All as per item No 79 but MCCB 250 Amps 35/36 KA.
All as per item No 79 but MCCB 100 Amps 25 KA.
All as per item No 79 but MCCB 160 Amps 36 KA.
All as per item No 79 but 63 Amps 25 KA.
Disconnecting, dismantling and taking out old unserviceable street/flood lights any type with bracket/ clamps from pole/ wall and keep in safe custody for reuse at same or other location with all accessories complete all as specified and directed.
Fixing only street/flood light fittings any type received from srl item No 84 complete with bracket/ clamps and connecting electrically with new wire 1.5 Sqmm twin core on same or other location with all accessories as required at site all as spfd and directed..
Repair, maint and of broken doors for LT panel and bus bars by welding and incl fixing of new hinges and other material as required at site complete all as spfd and directed.
Locating of cable fault in underground cable by providing of fault locating mobile machine (applying voltage 1.1 to 11 KV) mounted in van along with DG set with T&P at site for locating exact fault pf LT/HT underground cables complete all as spfd and directed.
M & L for replacement of existing unserviceable LT panel, Installation, commissioning and testing of new LT panel cubical type suitable for outdoor type, factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron frame fixed on RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 400 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-10 nos, MCB FP 63 Amps - 04 Nos and suitable for one incoming MCCB 250 Amps 4 pole 36 Ka, MCCB 250 amps 4 pole 36 ka-01 No, MCCB 100 Amps 4 pole 25 ka -02 Nos, MCCB 63 Amps 25 ka -02 Nos as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site complete all as required at site or directed by Engr-in-Charge. ( Note: 1. MCCBs will be measured and paid separately under respective items.)
All as per item No 88 but for copper bus bar 350 Amps 3 phase 4 wire and for one incoming MCCB 250 Amps 4 pole 35/36 ka, one Nos 160 Amps 4 pole 36 ka, three 63 Amps 25 ka MCCBs as outgoing and MCB FP 63 Amps=04 Nos, MCB DP 63 Amps- 10 Nos. ( Note: 1. MCCBs will be measured and paid separately under respective items.)
All as per item No 87 but for copper bus bar 600 Amps 3 phase 4 wire and for one incoming MCCB 400 Amps 4 pole 35/36 ka, outgoing one No 250 Amps 4 pole 35/36 ka, two Nos 100 Amps 4 pole 25 ka, two Nos 63 Amps 25 ka and MCB DP 63 Amps- 10 Nos, MCB FP 63 Amps=04 Nos. ( Note: 1. MCCBs will be measured and paid separately under respective items.)
M&L Earthing complete with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable complete all as specified & directed by Engr-in-charge Note :- If the desired earth resistance is not found earthing shall be redone by the contractor at no extra cast to the department
S & F Cable route indicator made out of stone patties / PCC block of size 15cm x 15cm x75cm in lengths duly engraved and painted with (HT Cable) with projection of 45 cm above ground level and 30 cm grouted in PCC foundation etc complete all as specified and directed. RCC shall be painted with yellow colour above ground and HT cable 11 KV will be marked with Red colour paint complete all as specified and directed. Note : Rate quoted by the contractor is deemed to be included for earth work and PCC foundation etc.
S & F Cable route indicator made out of stone patties / PCC block of size 15cm x 10cm x75cm in lengths duly engraved and painted with (LT Cable) with projection of 45 cm above ground level and 30 cm grouted in PCC foundation etc complete all as specified and directed.RCC shall be painted with yellow colour above ground and LT cable 1.1 KV will be marked with Black colour paint complete all as specified and directed. Note : Rate quoted by the contractor is deemed to be included for earth work and PCC foundation etc.
Servicing / Calibration to 11/6.6 KV HT VCB/OCB complete including the following (a) Taking out 11/6.6 KV HT VCB/OCB of 400 to 800 Amps rating trolley from HT Panel after switching off electric supply. checking of mechanical system for proper functioning of upward / downward movement of HT VCB/OCB trolley including opening the VCB/OCB & checking the mechanical system. cleaning & servicing the fixed / moving contact & blowing out dust and applying the proper lubrication / greasing and reassembling the VCB/OCB including connection to HT panel complete all as directed. (b) Taking out relay set of any make from HT 11/6.6 KV VCB/OCB panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed. Note:- (i) Testing of above job to be carried out by qualified and experienced person of concerned VCB/OCB (ii) Replacing new items shall be measured and paid separately under respective items of schedule. 3. Minor spares i.e nut, bolt, washers, wire & fuses or other minor parts if required shall deems to be included with the above job.
S&F in replacement of shunt trip coil assembly suitable for HT, VCB/OCB, operating on 30 / 110 volt system and testing complete all as specified and directed. (Make Crompton/GEC/Areva)
S&F in replacement of closing/tripping coil operated on 110/30 volt system as per sample suitable for working of relay of HT VCB/OCB complete all as specified and directed.
S&F in replacement of fabricated gears as required for spring charger of VCB/OCB as per sample complete all as specified and directed..
M&L for disconnecting electrically and dismantling of LT Panel at site and shifting/ refixing in other location and making all electrical connections and making plinth and finishing all surfaces of old panel to match with existing specification of surfaces i.e wall/floor etc all as spfd and directed. Note : Cost of T&P / transportation is included in this item)
M&L for disconnecting electrically and dismantling of HT OCB at site and shifting/ refixing in other location and making all electrical and earthing connections or deposited to MES store yard in area under GE (I) Kanpur all as spfd and directed. Note : Cost of T&P / transportation is included in this item)
Servicing of switch air break gang operated device (GOD) 200 amps, 11/6.6 KV, by cleaning moving / fix contact jaw ,MS jumper / MS jumper carrier including replacement of ACSR Jumpers with PG clamps, nut bolts etc and providing white petroleum jelly and making all connection tightened and aluminium lugs etc complete and testing on full operating etc all as specified and directed.
Taking down carefully transformer any capacity, any make, any type from pole / plinth by dismantling, dis-connecting HT & LT sides, earthings of transformer, supporting angles / cross arms, shifting / transporting transformer carefully from the site and shifting/refixing in other location under GE Kanpur after cleaning and making all electrical/earthing connections all as spfd and directed.
M&L for disconnecting electrically and dismantling of HT VCB at site and shifting/ refixing in other location and making all electrical and earthing connections in area under GE (I) Kanpur all as spfd and directed. Note : Cost of T&P / transportation is included in this item)
Dismantlling top cover of transformer of capacity upto 750 KVA , any make for repair / replacement of HT / LT bushing of transformer or for replacement of top cover gasket or for inspection of transformer or for minor internal repairs of transformer all including draining carefully transformer oil as required / upto the required level and refilling the same, re fixing the top cover of transformer after completion of the work including testing on completion complete all as specified and directed. Note - spare parts will be measured and paid separately
Dismantling old u/s HT 11 KV bushes and fixing in replacement of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity up to 250 KVA.
All as per item No.104 above but exceeding 250 KVA not exceeding 750 KVA.
Dismantling old u/s LT bushes and fixing in replacement of LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, locknuts and rubber seal for indoor/outdoor transformer of capacity not exceeding 250 KVA.
All as per item No 106 above but exceeding 250 KVA but not exceeding 750 KVA.
Repairs to the leaks of transformer from tap switch/ fins/ any pats of body, by replacing gasket / seal , or Repairs to the leaks of transformer body / fins, by welding / brazing etc complete all as specified and directed.
M&L for taking out old burnt winding and rewinding of HT/LT coil of different type, capacity and make of transformer with approved quality supper enamelled copper wire/ strip of approved make of suitable gauge and number of turns along with allied materials like cork sheet, fibre glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. all as required at site or directed.
M&L for cork sheet gaskit 3mm thick cut to shape for the top covers and other places with suitable holes for 11/6.6/0.433 KV transformer of any type/capacity including providing if required suitable size of bolts, nuts and washer for transformer top cover complete for any capacity/size transformer all as specified.
Filteration/dehydration of transformer oil for 11 KV/0.433 KV transformers,11 KV OCB's/PT's with stream line mobile 1250 Ltr per hrs filteration machine.(To be provided by the contractor and quoted prices deemed to include its hire charges) at a temperature from 60-75 degree celsius to achieve dielectric strength of oil 60 KV or over at standard gap as per IS 335 of 1993 (Fourth revision) to remove moisture from winding and core and carrying out IR test of primary and secondary of transformer including testing of transformer complete all as specified and directed. Note: (i) Filtration should be carried out in OFF position, therefore generator and cables will have to be arranged by the contractor at his own cost. (ii) Test result will be recorded before and after filtration of oil and submitted to Engr-in-Charge in a prescribed manner.
Supply and topping up of insulating Oil/pure hydrocarbon mineral oil, clean and sufficiently free from moisture and of other foreign matter as per ISS-335-1993 (fourth revision) incorporating up to date amendment of breakdown value - 60 KV or over at standard gap after filteration for topping up upto required level in transformers & Switchgears and PT's etc complete all as specified and directed and additional characteristics as indicated below: (a) Oxidation stability (i) Neutralization value after oxidation max 0.4 mg. KOH/gm. (ii) Total sludge after oxidation max 0.01% by weight. (b) Break down value 60 KV or over at standard gap (c) SK value up to 8% Make: APAR (POWER OIL) / CASTROL Note: - 1. Test report from manufacturer to be produced. 2. Filtration/dehydration of transformer oil shall be measured and paid separately.
M & L for marking/writing feeder names/ SM No / MES No for HT/LT Electrical Eqpts like VCB, Tfrs, LBS / RMU/panels etc with synthetic enamel paint of Make Asian paints Ltd. Or Stickers equivalent of approved color complete all as specified and directed.
S&F in replacement of HT 11 KV bus bar outdoor type weather and vermin proof factory fabricated CPRI approved duly painted with two coat of enamelled paint, pedestal type made out of mild steel sheet 3.15mm thick, factory made, using angle iron 40mm x 40mm x 6mm and 500mm high, front opening double shutter weather proof , rust proof, dust proof with provision of rubber gasket and locking arrangement including HT bush, insulator & bus bar color code - 03 Nos and making connection with suitable size of thimbles, nuts, bolts and washers etc incl necessary earth work:-
Removing the cover of cable duct for removal of unwanted vegetation/bushes/small plants/ shrubs/soil/old sand from cable duct not exc 3' wide and 3' deep and removing the excavated material to a distance exceeding 50 M and incl filling new river sand, relay the existing cables of any type/sizes and placing the cover after completion all as spfd and directed.
S&F in replacement of tap changer assembly with all accessories for transformer any type up to 750 KVA cap as per sample all as spfd and directed.
Disconnection of transformer of capacity up 750 KVA indoor/outdoor type 11/6.6 KV from LV/HV side including earthing GI strips etc and taking down transformer from plinth/pole all as specified and directed. Note : The rate deemed to be included of all tools and plants.
Transportation of Transformer from site E/M site/yard to workshop for repairing and from workshop to site /yard after repair etc of capacity uo to 750 KVA all as specified and directed . NOTE : The rate deemed to be included of transportation charges.
M/S S.DAYA SINGH
U K Enterprises
VEE KAY ENTERPRISES
Himanshu Construction and Suppliers
DUBEY TRADERS AND ENGINEERS
Bharat Sales Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .