Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹94.1 LAccepted-AOC 787 ISMAILABAD 136129 | KURUKSHETRA | HARYANA | 136129 | ₹94.1 L | 1 | Accepted-AOC OK |
| 2 | 2₹1.0 Cr+₹6.0 L (6.41%)Rejected-Finance NEW RAJIV COLONY SAFIDON DISTRICT JIND 126112 | SAFIDON | JIND | HARYANA | 126112 | ₹1.0 Cr+₹6.0 L (6.41%) | 2 | Rejected-Finance L2 |
| 3 | 3₹1.1 Cr+₹16.7 L (17.8%)Rejected-Finance 44 WARD NO 3 INDRI 132041 | KARNAL | HARYANA | 132041 | ₹1.1 Cr+₹16.7 L (17.8%) | 3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
14 Jan 2022, 2:00 pmClosed
Chief Executive Officer
Karnal Smart City Limited
Beautification of Cantonment Church Tower Precinct under Karnal Smart City Mission
2022_HRY_203228_1
KSCL/CEO/2021-22/683
Open Tender
Civil Works
Works
120 days
Karnal
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹2.3 L
25 Feb 2022
8 Jan 2022
14 Jan 2022
8 Jan 2022
14 Jan 2022
8 Jan 2022
Amount
Civil Works signage A type 1500x1200 information carving ,painting and repolishing on 40mm dholpur sandstone ,stone slab fixed between brick foundation(single stone) as shown in drawing and approved by engineer in-charge.
Supplying & installation with all nessesery foundation at site as per drawing detail GFRP Gazebo Victorian style is hand crafted by highly skilled craftsmen using sandwiched resin infusion process, is UV stabilized and weather resistant. It is light in weight, durable, and maintenance free. It is made in a modular form for easy assembly. The Gazebo structure and the roof are made from composites and have a metallic and wood finish look. specification as per drawing & conforming to indian standards, along with submission of the shop drawings for approval, complete in all respects. (Square shape)as shown in drawing and approved by engineer in-charge.
Providing and fixing Porta Cabin Size 8’x 7’x 9 Mild Steel with all nessery foundation,Walls- M.S Corrugated sheet of 1.2 mm thick,Roof – M.S sheet of 1.2 mm thick,Floor – M.S Framing with cross support block area,Bottom frame – ISMC 100mm X 50mm ‘C’ Channel,Top Frame - 63mm X 63mm MS square pipe,Bottom Stiffener – 80mm X 40mm MS square pipe,Side Post – 63mm X 63m,Doors & Vents1 MS door with canopy & handles,1 AC vent (split 1.5 ton ) Mild Steel (external door).2 nos Windows Windows size ( 4’X3’) Bulkheads above and safety grill outside 10mm X 10mm Aluminum powder coated Sliding.Wiring & SwitchesLED light fitting – 2 Cabin fun - 1External door light fitting -1,6 Amp. Point Modular Switch Socket -1,15 Amp . Point Modular Switch Socket -1,Modular Switch Board – 1,MCB main Box.Cabin fun- Surya, Lazer Anchor, Crompton,Wiring - Kalinga,Lights & Switches – Anchor.Insulation & Interiors Wooden framing in the whole container Glass,wool insulation of 50mm6mm laminated ply board,Wooden bittern and beading to cover the joints19mm wooden floor and 1.3 vinyl carpet Wooden Framing - CPLInsulation - Glass Wool.Exteriors4 hooksfor lifting and shifting Paint 1 coat primer and 2 coat epoxy paint Asian Paints.
Electrical works Main Control Panel : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required,Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels. Incomer :100A TPN MCB - 1NOS Outgoing : 25A TPN MCB - 5NOS Indication lamps (RYB) with control MCB - 03 Sets Danger notice plate Make : As listed in UHBVNL
Lighitng Control Panel : Fabrication, supplying and installation of outdoor type cubical panel board of suitable size made out of GI sheet 2 mm thick (14 SWG) and powder coated thereafter, duly compartmentalised having door locking arrangement for protection from rain, dust, duly fixed on GI angle iron frame work of size 50 mm x 50 mm x 6 mm (NS) and having following accessories mounted inside the panel including connection, inter connection with aluminium thimbles, earthing with two nos. earth studs, duly powder coated complete etc. as required,Civil Foundation cost for the panel shall be inclusive. Cable gland plates shall be provided on bottom. 2 Nos. earthing terminals shall be provided. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system, lifting hooks shall also be provided in case of large panels. Incomer :63A TPN MCB - 1NOS Outgoing : 25A TPN MCB - 4NOS Indication lamps (RYB) with control MCB - 03 Sets With Timer & Contactor Danger notice plate Make : As listed in UHBVNL
Static white 42W-48W Projector/Floodlight Luminaire Supply of Static white surface mounted Narrow/Medium beam Projector luminaire suitable for outdoor applications of Facade Lighting. Luminaires should be enabled with high power LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric distribution. With glass cover, clear/powder coated. Luminaire luminous flux range 2700-3000 Lm, Luminaire having ON/OFF control only. The luminaire should have options for various beam angles: 8⁰/15⁰/25⁰/35⁰/ 60⁰/30⁰x50⁰. Power consumption should be between 42W to 48W at steady state full intensity. Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral/ separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66 or higher. Housing should be made of pressure Die cast Aluminium with 3-4mm thick safety glass. Impact resistance level should be suitable to site condition minimum IK07. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. LEDs of CREE / LUMILED / OSRAM / SEOUL / SAMSUNG reputed make shall be used for the light fittings. Luminaire should be BIS approved. Cat. Ref. Bajaj RP series or equivalent Fixture must includes suitable driver with weather proof enclosure (IP66) inculding all type of connectors junction boxes are required for connection
Static 450W Warm White LED Projector Luminaire SITC of Static white surface mounted Narrow/Medium beam Projector luminaire suitable for outdoor applications of Facade Lighting. Luminaires should be enabled with high power LEDs, should consists of highly efficient, UV and temperature-resistant optics with symmetric distribution. With glass cover, clear/powder coated. Luminaire luminous flux range 19350 Lm(±10%) Luminaire having On/OFF control only. The luminaire should have options for various beam angles: 8⁰/15⁰/25⁰/35⁰/60⁰/30⁰x50⁰. Power consumption should be 450W steady state full intensity. Power factor of the luminaire shall be more than 0.90. Luminaire should be provided with suitable integral/separate non-integral power supply unit. The lumen maintenance L70@ 25 °C of the LED shall not be less than 70% of the initial lumen after 50,000 burning hours. Ingress Protection should be IP 66 or higher. Housing should be made of pressure Die cast Aluminium with 3-4mm thick safety glass. Impact resistance level should be suitable to site condition minimum IK07. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. LEDs of CREE / LUMILED / OSRAM / SEOUL / SAMSUNG reputed make shall be used for the light fittings. Luminaire should be BIS approved. Cat. Ref. Bajaj WW series or equivalent. Fixture must includes suitable driver with weather proof enclosure (IP66) inculding all type of connectors junction boxes are required for connection
STATIC 28W - 30W Burried Uplighter SITC of STATIC recessed mounted Narrow/Medium/Wide beam luminaire suitable for outdoor applications of Facade Lighting, depending on design by the contractor and site requirement. Luminaires should be enabled with high power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature-resistant lenses, suitable for architectural lighting as per design requirement. The luminaire should have options for various beam angles i.e. from 8° to 80°, actual will depend on the design by the contractor and site requirement. Power consumption should be between 28W to 30W at steady state full intensity, Luminaire luminous flux range of 1170- 1230 Lm. Light fixture should be standard DMX512 protocol compatible, Color rendering index CRI ≥ 80 and power factor of complete luminaire ≥ 0.90, at white colour. Luminaire should be provided with suitable integral/ separate non-integral power supply unit. Lumen maintenance of at least L70@50,000 burning hours at 25°C. The luminaire should have powder coating Die Cast aluminium housing with minimum 5-6mm thick safety glass with stanless steel cover.Ingress Protection ≥ IP 67. Impact resistance level ≥ IK10 . Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +50°C, Operating Humidity : 10%-90%. THD should be less than 15%. Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Connectors if used should be IP67 male/female connectors for loop through wiring. The LED Luminaires and external drivers drivers if used should be BIS certified. The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted post the issuance of LOA to the successful bidder and before the supply of material. Fixture must includes suitable driver with weather proof enclosure (IP66) inculding all type of connectors junction boxes are required for connections. Make of LEDs -LEDs of CREE / LUMINOUS / OSRAM / SEOUL / SAMSUNG/LUMILED /NICHIA.
Supply and Installation of 5mtr high URBAN ARCHITECTURE LIGHTING DECORATIVE POLE with 140 mm bottom diameter & 60 mm top diameter Black painted Galvanised pole in different cross section with gold colour painted decorative cast aluminium rings. Base plate is welded to pole with 4 nos. mounting holes. Supplied along with 4nos of M16X450 long 'J' type EN 8 grade foundation bolts along with template. Decorative pole should be supplied with Bakelite sheet with 2 Nos of 6A SP MCB and stud type connector suitable for cable termination upto 4Cx 16Sq mm cable. Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1 :5: 10 of required dimensions for decorative poles and specifications complete in all respects and as per directions of Engineer-in-charge
Post Top Light : Supply & Installation 45W decorative Led Post Top having Spun aluminium powder coated finished canopy,having Die-cast aluminum graphite grey powder coated spigot & Opal acrylic diffuser provided at LED area to minimize glare.The LEDs should be Low power LED & it should be connected in series and parallel combination with better heat dissipation arrangement.LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level)>=70lumens/watt, Minimum system Lumens 150 lm ±10%. CCT up to 3000K ±355K, CRI >70, PF >0.95,IP65. Luminaire is wired with inbuilt driver with 5kV surge protection and an operating Voltage Range of 140 to 280V C,50Hz. The driver should be specially designed to have high voltage, open and short circuit protection.Luminaire mounting should be Suitable for 60mm OD pipe entry with fixing bolts.The fixture should comply with the parameters as per IS10322, EMC / EMI compliance. Bajaj Cat. Ref.ARIAN - BGCT W4 LED WW LUMINAIRE MAKE : Phillips / OSRAM / Wipro / Crompton / Bajaj / Havells /Surya /Keselec. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM.
Supply of PVC insulated multi core electrical copper armored 3C x 2.5 Sq mm power cable having less electrical losses. This PVC insulated and round sheathed wire features a bright multi strands copper conductors and it supports voltage grade up to 1100V. (As per actuals depending upon the site condition)
Supply of PVC insulated multi core electrical copper armored 3C x 4 Sq mm power cable having less electrical losses. This PVC insulated and round sheathed wire features a bright multi strands copper conductors and it supports voltage grade up to 1100V. (As per actuals depending upon the site condition)
Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I) 4C x 6 sqmm Al Ar cable
Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I)4C x 10sqmm Al Ar cable
Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I) 4C x 16 sqmm Al Ar cable
Supply of following size XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part - I) 4C x 25 sqmm Al Ar cable
SITC of additional accessories for installing the lights as per the final drawing, consisting of conduits, joints, fastners, GI flat, channels, angles etc as required.
SITC of GI Earth busbar
O&M 2 Mali for 15 days a month, Maintenance of fine grass lawn for one year including fertilizer application, DAP @ 20gm/sqm, urea 40gm/sqm, watering, weeding, top dressing with good earth and manure mixture 2:1 @ 0.01cum per sqm, maintaining fine level, regular mowing and removal of rubbish with all lifts and leads,Maintenance of shrub for one year including weeding, hoeing, plant protection, watering from Deptt. source, application of 10 ml chlorpyriphos four times(as and when required) in a year , 0.0289cum FYM each, 20 gm urea and 20 gm DAP twice, replacement of casualty etc. with same species and same age of plant. In addition with 1 no. of electrician(for 10 days a month & 2 nos of Guard (with dress) for Per day for each shift for 1 year.
Bidder Name
Amount
The Swami Co-op. L and C Society Ltd.(GSTN-06AADAS9878A1Z9)
M/S Singla Construction Co.(GSTN-06BDPPS4086R1ZE)
Parveen Contractor(GSTN-NA)
Parveen Contractor
M/S Singla Construction Co.
The Swami Co-op. L and C Society Ltd.
M/S Singla Construction Co.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .