Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | ₹10.3 L | L1 | Accepted-AOC L1 offerer |
| 2 | L2₹11.0 L+₹77,317.50 (7.54%)Rejected-Finance | ₹11.0 L+₹77,317.50 (7.54%) | L2 | Rejected-Finance L2 offerer |
| 3 | L3₹11.1 L+₹80,999.21 (7.90%)Rejected-Finance | ₹11.1 L+₹80,999.21 (7.90%) | L3 | Rejected-Finance L3 offerer |
Tender Value
₹11.8 L
EMD Value
₹11,800
Closing Date
1 Aug 2024, 3:00 pmClosed
The DGM (CIVIL)
TCMPF Limited ,Aavin illam,Nandanam-35
Repairs and renovation works in the skill Development centre building at Madavaram Milk Colony
2024_TCMPF_463808_1
8694/Engg.2/2024
Open Tender
Civil Works
Works
180 days
Madavaram
Refer tender document
7 documents required · 7 mandatory
₹0
₹11,800
Yes
6 Sept 2024
18 Jul 2024
2 Aug 2024
18 Jul 2024
1 Aug 2024
18 Jul 2024
18 Jul 2024 - 1 Aug 2024
Amount
Removing the existing Partition and Door, Cupboard clearing away with carefully stacking the material useful for reuse etc., complete complying with standard specification and as directed by the Federation Engineer.
Supplying and fixing of stain free nano polish vitrified tiles of size 600 mm x 600 mm x 8mm of best approved quality and colour laid in cement mortar 1:3 ( One of Cement and three of M sand) 30mm thick and pointed with coloured cement neatly including cutting to the required size and shape wherever necessary finishing neatly etc. all complete complying with relevant standard specification and as directed by the Federation Engineer.
Providing and fixing of Wood Partition using 50x25mm Aluminium Section and one side 12mm thick BWR plywood with 2.5mm thick Ayralic PVC laminate finish, as per the drawing etc., complete complying with standard specification and as directed by the Federation Officers. The Model should be get approved from the Federation Engineer.
Providing and fixing of Wooden Finish Readymade Louvers etc., complete complying with standard specification and as directed by the Federation Engineer.
Providing and fixing of Reception Table Main Table size 10'x4' Using 19mm thick BWR plywood inner side half white 0.8mm thick lamniates finish, front side 1mm thick :Laminates Wooden Shade SF Finish and Designser Side 1mm Thick high Gloss Laminates as per the drawing etc., complete complying with standard specification and the model should be get approved from the Federation Engineer.
Providing and fixing Acrylic Letter 6inch( Letter size will be decided according to the board size) , complete complying with standard specification and etc., complete complying with standard specification and the letter should be get approved from the Federation Engineer. (26 Letters).
Providing and fixing of Wooden Frame Work for size of 4x3 feet using 12mm Thick BWR Plywood and all round Teakwood Beeding , as per the drawing etc., complete complying with standard specification and the model should be get approved from the Federation Engineer.
Providing and fixing of SS Material Brass finish Name Board ( Letter size will be decided according to the board size), complete complying with standard specification etc.and the model should be get approved from the Federation engineer and as directed by the Federation Engineer.
Providing and fixing of Foam with Vinyl printing finish Name Board and Size 5'x1' complete complying with standard specification etc., complete and the model should be get approved from the Federation Engineer.
Providing and fixing of Foam with Vinyl printing finish Name Board and 18"x3"etc., complete complying with standard specification and the model should be get approved from the Federation Engineer.
Providing and fixing of SS Sink for a size of 4x3 feet including cost ss stand for sink support of inlet and outlet hose and , SS long body bipcock 2nos,other fittings etc... , complete complying with standard specification and as directed by the Federation Engineer.
Providing and fixing of CP Angle Cock etc complete complying with standard specification and as directed by the Federation Engineer.
Providing and fixing of Two Way Bib Cock With Health Faucet etc complete complying with standard specification and as directed by the Federation Engineer.
Providing and fixing of Brass chromium plated Soap Tray of size150mm x100mm etc complete complying with standard specification and as directed by the Federation Engineer.
Providing and fixing of Brass chromium plated Towel rail of size 60 cm long and 20mm dia with brackets etc complete complying with standard specification and as directed by the Federation Engineer.
Providing and fixing of SS Curtain Rod 20mm dia and Cups with Curtain Clothes etc complete complying with standard specification and as directed by the Federation Engineer.
Providing and fixing of Existing Wooden Frame Structure using 12mm Thick BWR Plywood and all OST Teakwood grains with varnish Finish , as per the drawing etc., complete complying with standard specification and as directed by the Federation Engineer.
Labour charges for removing old iron window and kept at scarp yard in skill development center etc..complete complying with standard specification and as directed by the Federation Engineer.
Supply and fixing the Aluminum window with anodized aluminum natural colour matt finish sliding window in two track inall floors.All the two shutter with sliding arrangements the bottom section should have gutter arrangements so as to drain the water entering and made with extruddaluminum section for frame bottom track [email protected]/m frame top and [email protected]/mshutter section top and [email protected]/mvertical [email protected]/m and interlocking vertical section [email protected]/m with necessaryaccessaries such as rubber beading,aluminumclips,handlestopersandfixing4mmthick plainglass lock Langles,screws and including,conveyance scaffolding if anyetc.,all complete with relevant standard specifications and as directed by the Federation Engineer.
Supplying and fixing in position of aluminium anodized partition with 62x38x2mm extruded box section at bottom vertical and horizontal members. The vertical members are spaced at 90cm c/c and to horizontal members are spaced at 1.20m, 2.10m and 2.40m height as per the requirements at the site and the bottom panels should be covered with 9mm thick PLB exterior grade and the top and middle panels should be fixed at 5mm thick glass with necessary glassing clips, rubber beadings etc., including necessary dismantling holes in the RCC columns, beams masonry wherever necessary with power drill to the extent required and make good the dismantled portion to original condition after fixing as directed by the Federation officers. Aluminum doors with 5mm thick glass of 6 numbers should be provided including necessary supports, hinges and floor springs wherever necessary etc complete as per the standard specifications.
Providing door with aluminum anodized natural colour Powder coated halfglazed halfPLBdoor with outerframe,using alu.Boxsection andofsize101.60mmx44.75mmx1.75mmat1.367kg/mshutterframeatbottomusingalu.boxsectionofsize95.25mmx44.45mmx1.70mmat1.301kg/mattopusingaluminum,boxsectionofsize47.62mmx44.45mmx1.74mmat0.881kg/m,atvertical(lockrail)[email protected]/matvertical plain [email protected]/m and bottom&top panel covered with 12mmthick prelaminated board with necessary accessories suchas rubber beading,[email protected]/m,Langles,doorstopper,handle,morticelock150mmtowerbolt,125mmhinges,screws,PvcWoodenfeltetc.,complete the rate inclusive of labour powerconsumption charges required for febrication if necessary,clipping,dismantling the masonry RCC beams columns orginal condition after fixing etc.the complete the alusurface is to be anodized with matt finish under electrically controlled conditionin accordance with ISIspecification1868/1962 of anodic film thickness for all section all the materials should be got approved by the EE before fixing in position etc complete .
Supplying, fabricating, erecting and fixing Hilux (or) Equivalent Board False Ceiling upto a ceiling height of 4.5m from floor level Using Hilux Board Plain Sheets (10mm thick)etc..complete complying with standard specification and as directed by the Federation Engineer.
Supply and fixing of AC Exhaust fan 450mm(18'') sweep(Light duty) including cost of dismanling holes for exhaust fan and neatly finishing etc..complete complying with standard specification and as directed by the Federation Engineer.
Labour charges for removing of existing vertical blinds &old damaged vinyl flooring and kept at scarp yard in skill development center etc…complete complying with standard specification and as directed by the Federation Engineer.
Supply and fixing of roller blinds it include cost of material,labour,transport charges etc…complete complying with standard specification and as directed by the Federation Officers.Roller blinds shall be got approved by the Federation Engineer.
Supplying, fabricating and erection of MS grill complying with standard specifications. including anchor & connection bolt as specified in the deawing, welding as per IS 816, of approved quality and colour after sand blasting with necessary hire charges of crane, hoisting, equipments, rope charges etc, complete in all respects as directed by the Federation Engineer.
Plain Cement Concrete 1:2:4 using 20 mm size HBG stones for foundation including de-watering if found necessary and laid in layers of not more than 15 cm thick for flooring including rendering the top surface rough to take floor finish including side shuttering if required and compaction ,curing etc., complete as directed by the Federation Engineer and as per the technical Specifications
Earth work narrow excavation for foundation in all soils and sub soils and to full depth as may be directed except hard rock requiring blasting inclusive of shoring, shuttering and baling out water where ever necessary, refilling the sides of foundations with excabvated earth in layers of not more than 15cm thk watered, well rammed , consolidated and depositing the surplus earth on bank with initial lead of 10m and initial lift of 2m, clearing and leveling the site etc., complete as directed by the Federation Engineer and as per standard specifications.
Plain Cement Concrete 1:4:8 using 40 mm size HBG stones for foundation including de-watering if found necessary and laid in layers of not more than 15 cm thick for flooring including rendering the top surface rough to take floor finish including side shuttering if required and compaction ,curing etc., complete as directed by the Federation Engineer and as per the technical Specifications
Brick work in cement mortar 1:5 using II class chamber burnt brick of size 9" x 4½" x 3" to line level and to plumb on one face including necessary scaffolding, racking out joints curing etc., as directed by Federation Engineer and as per standard specifications.- 230 mm thick
Plastering the surface of walls with Cement Mortar 1:5 (One part cement and Five parts M sand), 12mm thick in all floors including curing etc., complete complying with standard specification and as directed by the Federation Engineer.
Supply and Painting ( Exterior / Interior) two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Removing and refixing of ms gate it include cost of material,labour,transport charges etc…complete complying with standard specification and as directed by the Federation Engineer.
Supply and fixing of vinyl flooring 2mm thick it include cost of material,labour,transport charges etc…complete complying with standard specification and as directed by the Federation Engineer.
Supply and fixing of pvc Hylem sheet 3mm thick etc..complete complying with standard specification and as directed by the Federation Engineer.
supply and fixing of sun control film 3mm thick it include cost of material,labour,transport charges etc…complete complying with standard specification and as directed by the Federation Engineer.
BRICK WORK in cement mortar 1: 3 (One cement and three sand) using second class chamber burnt bricks of size 9" x 41/2" x 3" for the Partition walls including hoop iron reinforcement curing etc., complete complying with standard specifications. - 0.115m
Dismantling brick work by using power drilling machine and clearing the debris away from our campus etc… complete as directed by the Federation Engineer and as per standard specification
Supply and fixing 100mm PVC pipe (having working pressure 6 kg. / sq.cm) including screw,clap,pvc adhesive,bend with necessary specials . etc, complete as directed by the Federation Engineer and as per standard specification
Supply and fixing 25mm PVC pipe (having working pressure 10 kg. / sq.cm) including screw,clap,pvc adhesive,bend with necessary specials . etc, complete as directed by the Federation Engineer and as per standard specification
supply and fixing of pvc bipcock etc..complete as directed by the Federation Engineer and as per standard specification
Dismantling tiles by using power chipping machine and clearing the debris away from our campus etc… complete as directed by the Federation Engineer and as per standard specification
GST (Note: The tenderer should quote the amount towards Goods and Service tax (GST) in the appropriate columns in terms of percentage (%). If not quoted, it will be considered that the rate quoted is inclusive of GST.)
SAS CONSTRUCTION (BID ID -1098963)
Thukkaram Builders and Contractors Private Limited (BID ID -1086871)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .