| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates | |
| 2 | L2₹23.8 L+₹2.5 L (11.6%)Rejected-Finance H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L2 | Rejected-Finance Higher side quoted amount | |
| 3 | L3₹24.0 L+₹2.6 L (12.4%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L3 | Rejected-Finance Higher side quoted amount | |
| 4 | L4₹24.1 L+₹2.8 L (13.1%)Rejected-Finance AWANTA BHAWAN SOURA SRINAGAR 190011 J K | SRINAGAR | JAMMU AND KASHMIR | 190011 | L4 | Rejected-Finance Higher side quoted amount | |
| 5 | L5₹25.1 L+₹3.8 L (17.7%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L5 | Rejected-Finance Higher side quoted amount |
Tender Value
Refer Docs
EMD Value
₹51,600
Closing Date
15 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
CWE Khumbathang
SPECIAL REPAIR OF 1X200 KVA DG SETAGAINST BER AT SOUTH POWER HOUSE UNDER GE KHUMBATHANG
2023_MES_614299_1
80051/47/E8
Open Tender
Civil Works
Works
150 days
Khumbathang
Class D, Cat b(i)
8 documents required · 8 mandatory
₹500
GE Khumbathang
₹51,600
Yes
6 Oct 2023
18 Aug 2023
16 Sept 2023
18 Aug 2023
15 Sept 2023
1 Sept 2023
Amount
Supply and installation, testing and commissioning of diesel engine driven generating set of capacity 200 KVA (160 KW), 4 cylinder in line 4 stroke,415 Volts, 0.8 power factor at NTP, mounted on common base frame with flexible coupling, 1500 RPM, with silencer pipe protected with asbestos rope independently supported from engine to outside of power house up to 0.50 metre, AVM pads, PCC 1:2:4 type B-I (using 20mm graded crushed stone aggregate) foundation as per manufacturer's design, cold starting kit, battery start with suitable cables for connecting from DG set to panel board and with first fill of lube oil and coolant (DG set shall be capable of operating in temp range of (-35°C to + 35°C) complete including the following (A) PRIME MOVER. Vertical engine of suitable capacity water cooled (Radiator mounted) EG complete 50:50, bore 95 x 115mm, CR 19:1, Displacement 3.3 ltr, ISO 8528-5 G2, CI4+ 15W40, exhaust pipe size 3 inch, mean piton speed 5.75 m/sec, air intake @ 100 % load 160 CFM, exhaust temp 490 degree celcius, closed circuit as per BS-649 or IS-10002 direct injection type turbo charged electric starting system having rated speed 1500 RPM. DG Set conforming IS/IEC 60034-1, IS 1460, ISO 8528/3046/9001 AND IS 13018. Engine protection low lube oil pressure, high/low coolant temp, battery over/under/weak volts, fail to crank/start, sensor failure, cranking lockout, low fuel level and alternator protection over/under voltage, over/under frequency, loss of ac sensing etc. The DG set shall be capable of running 24 hours continously with 10% overloading for one hour in every 12 hours run as per BS-5514/BS-649.
(c) Frequency meter : 01 No (d) KW & KWH meter : 01 No. (e) Moulded case circuit breaker 1 No with overload and short circuit protections (for incoming) as recommended by manufacturer. (f) Set of insulated copper bus bar of suitable capacity (g) Set of indicating lamps (h) Set of instrument fuses (j) Any other fitting/accessories as recommended by the manufacturer. (D) OTHER FITTINGS. (a) Battery Charger. Battery charger having electric circuit consisting of triodes, rectifiers, capacitors and resistance etc. The battery charger should be able to charge the battery at all the time whenever electric supply given to battery charger though control panel or electric power point. Model No 12/48 Make : ELAK or EQUIVELENT. (b) Fuel tank with provision of cleaning of suitable capacity as per manufacturer's instructions capable to store 12 hours running of DG set with supporting fabricated steel stand with all pipes connecting upto fuel pump including oil level indicating gauge, drain & air vent plug etc.
Material and labour for cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 3.5 core 240 sqmm. complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009.00 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32X6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc in hard/dense soil as directed.
Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil all as directed.
Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point all as directed.
M&L for stone dust sand cushioning to UG cable laid in trenches all as specified and directed.
Supplying and laying unreinforced precast concrete cable cover, class LV, type 1 flate size 250mm x150mm x 40mm placed perpendicular of the cable complete.
M/S A K ENGINEERS & CO.
M/S TRADE LINK
EVERGREEN GROUP OF INDUSTRIES
national engineering
SUMEET TRADING CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .