| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹94.8 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹95.6 L+₹80,074.50 (0.85%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹99.1 L+₹4.4 L (4.61%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹1.2 Cr+₹21.0 L (22.2%)Admitted-Finance RZ 151 BLOCK Y NEW ROSHANPURA PAPRAWAT ROAD NAJAFGARH SOUTH WEST DELHI DELHI 110043 | WEST DELHI | DELHI | 110043 | L4 | Admitted-Finance | |
| 5 | Rejected-Technical | - | Rejected-Technical Technically not Qualified |
| Sl No | Description | Qty | Unit | M/s S.K.Industries L2 | MODERN CONCEPT CONSTRUCTIONS L4 | M/s. Leonine Constructions L1 | M/s Amrit Lal Behl and Sons L3 |
|---|---|---|---|---|---|---|---|
| 1.001) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | |||||||
| 2.00 | 1.1) All kinds of soil. | 68.39 | Cum | 200 ₹13,678 Lowest | 200 ₹13,678 Lowest | 200 ₹13,678 Lowest | 300 ₹20,517 |
| 3.00 | 2) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 54.17 | Cum | 150 ₹8,125.5 | 150 ₹8,125.5 | 50 ₹2,708.5 Lowest | 200 ₹10,834 |
| 4.00 | 3) Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 45.04 | Cum | 1,250 ₹56,300 | 1,800 ₹81,072 | 800 ₹36,032 Lowest | 2,000 ₹90,080 |
| 5.00 | 4) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | 10.63 | Cum | 5,000 ₹53,150 Lowest | 5,000 ₹53,150 Lowest | 5,500 ₹58,465 | 5,000 ₹53,150 Lowest |
| 6.00 | 5) Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns | 148.44 | Sqm | 225 ₹33,399 | 200 ₹29,688 Lowest | 250 ₹37,110 | 300 ₹44,532 |
| 7.00 | 6) Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). | 36.48 | Sqm | 350 ₹12,768 | 400 ₹14,592 | 250 ₹9,120 Lowest | 450 ₹16,416 |
| 8.007) Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. | |||||||
| 9.007.1) All works upto plinth level: | |||||||
| 10.00 | 7.1.1) M-10 grade plain cement concrete (cement content considered @ 220 kg/cum) | 80.85 | Cum | 5,900 ₹4,77,015 Lowest | 7,500 ₹6,06,375 | 6,000 ₹4,85,100 | 6,500 ₹5,25,525 |
Tender Value
₹1.2 Cr
Closing Date
24 Jan 2022, 3:00 pmClosed
Executive Engineer (CD-III)
MZ-137, Main Building, IIT DELHI 110016
Construction of temporary structure for central fabrication facility, cart lab and A/C maintenance unit Horticulture Nursery-II at IIT Delhi.
2022_IIT_667824_1
IITD/ WORKS(SP- 3757)/2022
Open Tender
Miscellaneous Works
Works
120 days
Indian Institute of Technology Delhi
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,500
Registrar IIT Delhi
Exempted
11 Feb 2022
11 Jan 2022
25 Jan 2022
11 Jan 2022
24 Jan 2022
11 Jan 2022
Amount
1) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
1.1) All kinds of soil.
2) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
3) Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
4) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
5) Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns
6) Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
7) Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.
7.1) All works upto plinth level:
7.1.1) M-10 grade plain cement concrete (cement content considered @ 220 kg/cum)
8) Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
9) Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
9.1) Thermo-Mechanically Treated bars of grade Fe-500D or more
10) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
11) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
11.) Cement mortar 1:4 (1 cement : 4 coarse sand)
12) Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
13) Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
13.1) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
14) Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
15) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
16) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
17) Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
18) Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
18.1) Twin rubber stopper
19) Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
19.1) 80x1.20 mm M.S. laths with 1.20 mm thick top cover
20) Providing and fixing ball bearing for rolling shutters
21) Extra for providing mechanical device chain and crank operation for operating rolling shutters.
21.1) Exceeding 10.00 sqm and upto 16.80 sqm in the area
22) Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
23) Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
23.1) Hot finished welded type tubes
24) Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
25) 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
26) Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
27) Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
28) Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
29) Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
29.1) Ridges plain (500 - 600mm)
29.2) Gutter (600 mm over all girth)
30) Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
30.1) GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
31) Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 48 kg/m3,50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing GI wire etc. complete as per directions of Engineer-inCharge.
32) 12 mm cement plaster of mix :
32.1) 1:4 (1 cement: 4 coarse sand)
32) Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
33) Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :
33.1) Two or more coats on new work
34) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
35) Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
36) Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
37) Providing and laying at or near ground level factory made kerb stone of M- 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
38) Providing and laying factory made coloured chamfered edge Cement Concrete paver blocks of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer’s specifications & direction of Engineerin-Charge. 60mm thick C.C. paver block of M-35 grade with approved colour, design & pattern.
39) Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
39.1) W.C. pan with ISI marked white solid plastic seat and lid
40) Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
40.1) White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
41) Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
42) Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe: 32 mm dia
43) Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm
44) Providing and fixing soil, waste and vent pipes : 100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
45) Providing and fixing soil, waste and vent pipes : 75 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
46) Providing and fixing plain bend of required degree. 100 mm dia: Sand cast iron S&S as per IS : 3989
47) Providing and fixing plain bend of required degree. 75 mm dia, Sand cast iron S&S as per IS - 3989
48) Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm
49) Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :75 mm
50) Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 75 mm outlet : Sand cast iron S&S as per IS - 3989
51) Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall
51.1) 20 mm dia nominal bore
52) Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work
52.1) 20 mm dia nominal bore
53) Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
53.1) 25 to 40 mm nominal bore
54) Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
54.1) 20 mm nominal bore
55) Providing and fixing uplasticised PVC connection pipe with brass unions :
55.1) 45 cm length
55.1.1) 15 mm nominal bore
56) Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
56.1) 20 mm diameter pipe
57) Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
57.1) 20 mm nominal bore
58) Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
59) Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
59.1) 100 mm diameter
60) Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
60.1) 100 mm diameter S.W. pipe
61) Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
61.1) 100x100 mm size P type
61.1.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
62) Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
62.1) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
62.1.1) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
63) Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
63.1) For pipes 100 to 250 mm diameter
64) Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
64.1) For fixed portion
64.1.1) Powder coated aluminium (minimum thickness of powder coating 50 micron)
65) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
65.1) Powder coated aluminium (minimum thickness of powder coating 50 micron)
66) Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
66.1) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
67) Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete
67.1) Upto 5mm depth and 5 mm width
68) Providing and fixing of external wall system on Light gauge steel frame/ Steel Structure work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000, category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make. A grove of 2 mm to 3mm shall be maintained and groves shall be sealed with silicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm and internal face 12.5mm thick gypsum plaster board fixed on 8mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately).
69) Providing and fixing roller blinds, the febric should be screen openness of 5% and composition of 75% PVC 25% polyster with fabric weight of 465 GSM with fire resistance grade of NSPA 701, BS 586 part- II with anodized aluminium channel weight, bracket and hangers etc. the fabric will be approved colour and shed of approved manufacturer complete. Make (VISTA/MAC/Marvel
70) Providing and fixing GI tank Nipple of approved make in PVC tanks as per directions of Engineer-In-Charge.( 20 mm nominal bor)e
71) Providing and Fixing of C.P. Brass bib cock (Short body) of approved quality complete as per the directions of Engineer in-charge. (Make: Jaquar/Marc/Kohler) 15mm nominal bore
72) Providing and Fixing of gun metal gate valve with C.I. wheel of approved quality complete as per directions of Engineer-In-Charge. (Make: Zoloto/Leader/Sant) 20mm nominal bore
73) Providing and fixing fly proof wire guaze to windows, clerestory windows and doors with screws/ washer etc. or by approved means as per manufacturer's specifications. (a) Stainless steel (grade 304) wire guaze of 0.38 mm dia wire and 1.4 mm aperture on both sides. (complete area of shutter will be measured for payment and no extra payment for folding the wire guaze at edges will be made for material and labour etc.)
74) Providing and Fixing of C.P. brass angle valve/angular stop cock for wash basin and geyser and WC points of approved quality complete as per the direction of Engineer in-charge.(Make - Jaquar/Marc/Kohler)
75) Providing and fixing 100mm C.P. grating with or without hole for nahani trap/floor trap of approved make and as per directions of Emgineer-In-Charge.
76) Providing and Fixing hand health faucet of standard size and design with one metre long flexible tube and wall hook complete in all respect.
77) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
77.1) Group C
78) Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
78.1) Group C
79) Wiring for light/ power plug with 2X4 sq.mmFRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as reqd.
80) Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
81) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
81.1) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
81.2) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
81.3) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
81.4) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
82) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
82.1) 3 x 6 sq. mm
82.2) 6 x 6 sq. mm
83) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
83.1) 5/6 A switch
83.2) 3 pin 5/6 A socket outlet
84) Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
85) Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
85.1) 12 Module (200 mmX150 mm)
86) Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. Rate to be taken
87) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
87.1) 125 A, 16 kA,TPMCCB
88) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
88.1) 8 way, Double door
89) Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (MCCB as a incomer)
89.1) 12 way (4 + 36), Double door
90) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
90.1) Single pole
91) Supplying and fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
92) Supplying and fixing following rating, Triple pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
93) Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
94) Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
95) Supplying and fixing 63A, 415 V, 5 pin Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 63A "C" curve, TPNMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
96) Supplying and Fixing DLP U-PVC turnking of 105mm x 50mm on surface etc as required.
97) Supplying and Fixing Full Flexible cover of width 85mm on existing DLP U-PVC turnking etc as required.
98) Supplying and Fixing of 90ͦ internal/external angle in existing DLP U-PVC turnking etc as required.
99) Supplying and Fixing of End cap on existing DLP U-PVC turnking etc as required.
100) Supplying/installation/Testing and commissioning of Recess mounting LED luminaire with chain and hook, equipped with CRCA powder coating housing, anti glare polycarbonate diffuser with energy efficient electronic driver with following features:- Suitable for operating voltage and frequency: 130-300 Va.c, 50 Hz.; wattage not more than 34 Watts;Output lumens not less than 3400 lm; CCT 6500K; Dimension in mm (595X595X70); Nominal surge protection 2.5 kV;Power factor not less than 0.9; Minimum IP protection 20;
101) S/I/T/C of 12 watt LED bulk head fitting made of aluminium bulkhead suitable for 130-300 Aa.c, 50 Hz, wattage not less then 12 watt, output lumens not less than 1200 lm,IP-65 etc as required.
102) S/I/T/C of 1200 mm size (5 star) of double ball bearing,copper winding, capacitor start Ceiling fan of approved make suitable for 230 volt, 50 Hz, sigle phase A.C. supply and complete with all standard accessories such as Motors, Blades & Capacitor, fan box cover i/c wiring the down rod with 1.5 sq.mm FRLS copper conductor wires from the point outlet etc complete as required.
103) S/I/T/C of 10"(250mm) size,copper wound, ventiling fresh air fan of double ball bearing capacitor start,suitable for 230 volt,50 Hz,single phase A.C. supply and complete with accessories such as motor, legs,frame,loober and Nut & bolts etc complete as required.
104) Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
105) Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
106) Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
107) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
108) Providing and fixing 160A,25kA,FP MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in cubicle panel board suitable for 415 volt,3 phase,4 wire,50 Hz A.C supply system fabricated CRCA sheet steel of 2mm thick including cleaning & finishing complete with powder coating in approved shade including drilling holes in cubicle panel, making connections, etc. as required.
109) Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,protective covering and refilling the trench etc as required.
109.1) Upto 35 sq. mm (3.5C x 35 sq.mm)
109.2) Above 35 sq. mm and upto 95 sq. mm (3.5C x 50 sq.mm)
109.3) Above 35 sq. mm and upto 95 sq. mm (3.5C x 95 sq.mm)
109.4) Above 95 sq. mm and upto 185 sq. mm (3.5C x 150 sq.mm)
110) Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
110.1) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) (3.5C x 50 sq.mm)
110.2) Above 95 sq. mm and upto 185 sq. mm (3.5C x 150 sq.mm)
111) Supplying and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size on wall surface as required.
111.1) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) (3.5C x 50 sq.mm)
112.2) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) (3.5C x 150 sq.mm)
112) Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
112.1) 3½ X 35 sq. mm (32mm)
112.2) 3½ X 50 sq. mm (35mm)
112.3) 3½ X 95 sq. mm (45mm)
112.4) 3½ X 150 sq. mm (50mm)
113) Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
113.1) 100 mm dia
114) Supplying, Installation, Testing & Commissioning i/c making foundation of cubical type Feeder Pillar Double Door Outdoor Type suitable for 415V, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with for powder coating for prickling and degreasing in approved shade, having 500 amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 2.5 sq.mm PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears.Size of Feeder Pillar : 1.3 mtr x 1.6 mtr x 300mm deep.
INCOMER
114.1) 1 Nos. 400 Amps. FP MCCB of 36 KA with inbuilt protection.
MAIN BUS BARS
114.1) TPN aluminium bus bars of minimum of 500 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec.
METERING
114.1) 3 Nos. phase indication lights LED type with protection MCB.
OUTGOINGS
114.1) 2 Nos. 200 Amps. FP MCCB of 25 KA with inbuilt protection.
114.1) 3 Nos. 160 Amps. FP MCCB of 25 KA with inbuilt protection.
114.1.1) Total Panel Cubical Type Feeder Pillar AS DESCRIBED ABOVE.
M/s S.K.Industries
M/s Amrit Lal Behl and Sons
MODERN CONCEPT CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
BOQ_702862.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .