| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.5 LAccepted-AOC KAIRU VPO KAIRU 127029 | KAIRU | BHIWANI | HARYANA | 127029 | 1 | Accepted-AOC ok | |
| 2 | 2₹34.1 L+₹4.4 L (14.6%)Rejected-AOC | 2 | Rejected-AOC ok |
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
30 Mar 2021, 3:00 pmClosed
EE PHED TOsham
EE PHED TOsham
Hetampura village providing pumping statio and rising main
2021_HRY_164506_1
No. 3569-3625 dt.16/03/2021
Open Tender
Civil Works
Works
Hetampura
Hetampura village providing pumping statio and rising main
2 documents required · 2 mandatory
₹1,000
₹38,000
Yes
2 Jul 2021
17 Mar 2021
30 Mar 2021
17 Mar 2021
30 Mar 2021
17 Mar 2021
17 Mar 2021 - 30 Mar 2021
Amount
Supply & Erection of Non clog submersible pump with suitable electrical motors with accssories as described in schedule No. II complete in all respect with submersible cable of suitable size 30 M doble length with comlete base frame lifting mono rail chain guide line etc. Raw water pump set (at Jui Canal) 1600 LPM, 35 mtrs head with squirrel cage induction motor 1440 RPM, 3 phase 50 Hz of four star rating
Supply and fixing following C.I. D/F pipe and specials/Sluice valves/ Non Return valves/Bell mouth/Reflex valves including cost of Jointing materials, excavation, laying, jointing reffiling including making adequate support of masonry/concrete steel for delivery/and erection pipe from bell mouth in the collecting tank to the rising main laid by the department as per plan shown from the foundation wall of the pump chamber for all the raw water and clear water pumping sets at water works as per specification given in Scheudle No. II (i) 2 Nos pumps for clear water & 2 Nos for raw water A) Detail of pipe and specials A) CI D/F bends, Reducers, tees etc. for H/W, P/M
(B) C.I. D/F pipe 200mm i/d
Supply, erection, testing and commissioning Wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm and 400 mm deep having following items. a) Main switch 63 Amp. 1 No. & 100 Amp. 1 No. (L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 Volt 1 No. (AE/KAPPA/L&T) c) Amp meter 100x100 mm range 0 to 100 Amp. 2 Nos. (AE/KAPPA/L&T) d) CT 100/3 Nos. (AE/KAPPA/L&T) e) VSS & ASS 1 No. each of approved make f) SPP 1 No. of approved make g) Motor starter, star delta 1 No. for 1600 LPM x 35 M Head Motor (L&T Siemens, ABB) h) Capacity KVAR as per site requirement i) Indicating Lamp - One Set
Supply erection testing and commissionig of LT cables, PVC couper armourd cale includig cost of thimbles lugs for making connection comlete description as per item No. 9 of approved specification From LT pannel to Energy meter 1100 volt 1x16 sqmm 3 core (for 1600 LPMx 35 mtr)
Supply and fixing of insulated rubber matting suitable for 11 KV installation 1 meter x 2 meter x 12 mm / as per panel SPEC for site as per specification given in schdule NO. II complete in all respect
Supply and fixing Ceiling fan 48" complete in all resect
Supply and fixing Sodium waour light 400 watt
Supply erection, testing of light fittings including wire in the Pump chamber with material upto 10 points including switch, button, plug, PVC conduict pipe & copper wire etc. as per approved specifications.
Supply erection, testing and commissioning of disel generating set 30 KVA laying noize control acoustic enclosure radiator colled, 3 phase, 4 wire, 50 cycles 415+(-) 1% volts AC alternator coupled directly through a set of flexible coupling on a common MS Fabricated base frame with diesel engine The rating should be at 1500 RPM Diesel Enginee :- Alternator :- Base Plate Battery 24 V 1 x 120 sq.mm 3.0 core XLPE Aluminum = 20 m Tools A.M.F. Panel (a) Motorised Change over switch 250 Amp. 4 P with fuse base and HRC Links 250 Amp. (b) under voltage /Over voltage relay 2 Nos 415 VAC (c) Engine Start relay 24 VDC 1 No. (d) Electronic Timber 24 VDC 1 No. (e) Electronic Timber 24 VDC 2 No. (f) Aumiliary relay 220 VAC = 2 Nos (g) Aumitiary relay 220 VAC 3 Nos (h) Metering set 415 VAC 1 set (Amp. Meter Volt meter ASS,VSS Phase Indicaters Control fuse frequency meter CTS) (i) Metering set 24 V DC (Amp Meter Volt Meter) (j) Over Load protection for DC 1 No. (k) Battery Charges 24 V DC (Blueron make) (l) Copper bus bar of suitable size (m) KWH meter 96 square mm size (n) Starting fuse button and key switch (on/Off) (o) Engine Protection unit with Audiovisual Alarm and shut down for low lubiricating oil pressure and high coolant temperature (p) Indicating lump for low lubricating oil pressure high collant tempurature, set running, load on, DC Control on Note :- Control pannel shall have the provisoin to provide auto manual failure panel (AMFP)
Rising main Stringing out DI pipe and special casting along trenches and laying the same in trenches to correct alignment and gradients including cartage from Divisional store or nearest railway station to site of work and return of piece of pipe to store. 250 mm internal diameter pipe line laid complete
Cutting DI pipes and specials and chipping or filling surface to a uniform finish. 250 mm i/d
Jointing DI socketted pipes, valves & specials with rubber fitted complete including cost of labour and tools etc. and tested complete. 250 mm i/d
D.I. Tees, Bends, Reducers etc. for distribution system all specials duly ISI marked
Bidder Name
Amount
Ramakant Sharma(GSTN-NA)
Jagbir Singh Contractor(GSTN-NA)
Jagbir Singh Contractor
Jagbir Singh Contractor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .