| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAdmitted-Finance | ₹2.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.7 Cr+₹57,152 (0.21%)Admitted-Finance | ₹2.7 Cr+₹57,152 (0.21%) | L2 | Admitted-Finance |
| 3 | L3₹2.9 Cr+₹12.8 L (4.66%)Admitted-Finance 43 TRIDEEP BUNGLOW MIDDLE CLASS HSG SOC NEXT TO ARYAN SCHOOL GROUND PALGHAR MAHARASHTRA | PALGHAR | PALGHAR | MAHARASHTRA | 401404 | ₹2.9 Cr+₹12.8 L (4.66%) | L3 | Admitted-Finance |
| 4 | L4₹2.9 Cr+₹15.5 L (5.67%)Admitted-Finance | ₹2.9 Cr+₹15.5 L (5.67%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S DATTATRAY CONSTRUCTION L4 | SVJ INOVABUILD PRIVATE LIMITED L2 | DIPAK S PIMPLE ENGINEERS AND CONTRACTORS L3 | PRANSHU ENGINEERS AND CONTRACTORS PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Providing and laying in cement concrete(RCC/PCC) of 1:1.5:3 at all levels (1 cement, 1.5 crushed
sand, 3 graded stone aggregate of nominal size 20 mm) including consolidation, finishing, curing
etc.. complete as per per drawings, specifications and as directed by the Engineer-in-charges but excluding the cost of shuttering, centering and steel reinforcement. | 160 | Cum | 7,550 ₹12,08,000 | 6,136 ₹9,81,760 Lowest | 6,627 ₹10,60,320 | 7,700 ₹12,32,000 |
| 2.00 | Providing, centering, shuttering Form work using steel plates, timber planks for all types of structures including necessary strutting, proping, staging, supports, bracings etc. and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels. | 1,800 | Sq.M | 575 ₹10,35,000 | 472 ₹8,49,600 Lowest | 700 ₹12,60,000 | 550 ₹9,90,000 |
| 3.00 | Providing and Laying Solid cement concrete block masonry with M-5 Grade of 190/ 140 mm thick in super structure in cement mortar 1:4 (using crushed sand). The rate shall also including scafolding/ staging, drilling of holes (if any) for fixing of rebar by applying chemical or welding or as directed by EIC including Making the cut out opening in masonary for flush concealing DB/plug point/switch box enclosure including dismantling in floor or walls by cutting masonary and making good the damage to walls, painting, etc. existing surface including disposal of rubbish to the naerest dumping ground at a minimum distance of 50m away from the building. Complete all as per drawings and specifications and as directed by the Engineer-in-charge. Note:( Reinforcement will be paid under relevant item) | 900 | Cum | 9,350 ₹84,15,000 Lowest | 9,440 ₹84,96,000 | 9,910 ₹89,19,000 | 10,500 ₹94,50,000 |
| 4.00 | Providing and fixing TMT Steel Reinforcement bars of specified grades manufactured using virgin materials confirming to IS 1786 for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge(Steel supplied by contractor). | 24 | MT | 95,000 ₹22,80,000 | 89,680 ₹21,52,320 Lowest | 92,190 ₹22,12,560 | 90,000 ₹21,60,000 |
| 5.00 | Providing and fixing of Hollow metal Two Hour fire rated doors(Single/ Double leaved) consisting of door frame and shutters and all hardware fittings as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specifications. The recommended fire doors shall have type test report from NABL cerified lab for minimum rating of 2 hours with vision panel. Deviation in specification and sheet thickness other than what is mentioned in the test certificates shall not be allowed. Proper label confirming the type of door and the hourly rating shall be mandatory. Door shall include fixing 4 nos heavy duty stainless steel 304 grade ball bearing, fire tested stainless steel butt hinges of size 100 x 75 x 3.00 mm (heavy weight) with suitable stainless steel screws, mortise / dead lock , a pair of 200 mm long stainless steel handles, 250 mm long stainless steel tower bolt / concealed tower bolt etc. frame hollow portion filled with PCC 1:2:4, necessary hold fast embedded in concrete, fixing in concrete with anchor fasteners. finished with Polyurethane painting of approved colour complete all as per drawings and specifications and as directed by the Engineer-in-charge | 65 | Sq.M | 13,550 ₹8,80,750 | 11,800 ₹7,67,000 Lowest | 12,883 ₹8,37,395 | 12,500 ₹8,12,500 |
| 6.00 | Providing and fixing fire rated Steel Rim Panic Exit Device of approved brand & quality in single leaf door upto 1000mm wide including all accessories etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. | 15 | nos. | 18,500 ₹2,77,500 | 9,440 ₹1,41,600 Lowest | 10,079 ₹1,51,185 | 12,000 ₹1,80,000 |
| 7.00 | Supplying and fixing Rolling shutters as per ISI standards made out of required size of MS lathes 18 gauge interlocked together throughout entire length and jointed together at the end by end locks mounted on specially designed pipes shaft with brackets, side guides and arrangements for inside & outside locking with push and pull operation complete including the cost of providing and fixing necessary springs of required size and M. S top cover of required thickness for rolling shutters Rolling shutters (Laths Interlocked) gear operated type with handles including top hood 1.25mm mm thick complete all as per drawings and specifications and as directed by the Engineer-in-charge. | 250 | Sq.M | 6,550 ₹16,37,500 | 7,906 ₹19,76,500 | 5,791 ₹14,47,750 Lowest | 6,700 ₹16,75,000 |
| 8.00 | Extra over the cost of rolling shutters for providing and fixing motorized arrangements( with
remote & manual operation) including designing, control panels, limit switches, required wiring
and cables from panel to motor and required size of shaft etc all as per standard specifications including commissioning and testing complete all as per drawings and specifications and as directed by the Engineer-in-charge.(only power supply point will be provided) | 14 | Each | 75,000 ₹10,50,000 | 24,780 ₹3,46,920 | 60,747 ₹8,50,458 | 24,000 ₹3,36,000 Lowest |
| 9.00 | Extra over the cost of rolling shutters for providing wicket gate of specified size in the M.S rolling
shutters including fixing with fixing arrangements, hinges, locking arrangements, frames etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge. | 40 | Sq.M | 4,500 ₹1,80,000 Lowest | 7,670 ₹3,06,800 | 6,688 ₹2,67,520 | 4,850 ₹1,94,000 |
| 10.00 | Providing 20 mm thick plastering using Ready mix external plastering compound for external faces of brickwork / concrete surfaces including water proofing compound @ 2% by weight of cemen, preparation of the surface, curing, cleaning scaffolding up to 10 metres height complete.all as per specifications including forming drip moulds wherever necessary,including Providing and fixing G.I. chicken mesh in the junctions of concrete & brick work / masonry (including cutting, fixing with nails in position before plastering) and complete all as per drawings and specifications and as directed by the Engineer-in-charge. | 10,000 | Sq.M | 705 ₹70,50,000 | 737.5 ₹73,75,000 | 855 ₹85,50,000 | 700 ₹70,00,000 Lowest |
Tender Value
₹3.2 Cr
EMD Value
₹6.4 L
Closing Date
9 Jun 2025, 3:00 pmClosed
Project Director, INRPC
Project Director INRPC, BARC TARAPUR
Peripheral block masonry with allied works of Block-102B and associated areas at INRPC, BARC, Tarapur.
2025_NRB_861396_1
BARC/NRB(T)/PTC123/2025/817
Open Tender
Civil Works
Item Rate
INRPC, BARC, Tarapur
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹6.4 L
16 Jul 2025
24 May 2025
11 Jun 2025
24 May 2025
9 Jun 2025
24 May 2025
Amount
Providing and laying in cement concrete(RCC/PCC) of 1:1.5:3 at all levels (1 cement, 1.5 crushed sand, 3 graded stone aggregate of nominal size 20 mm) including consolidation, finishing, curing etc.. complete as per per drawings, specifications and as directed by the Engineer-in-charges but excluding the cost of shuttering, centering and steel reinforcement.
Providing, centering, shuttering Form work using steel plates, timber planks for all types of structures including necessary strutting, proping, staging, supports, bracings etc. and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels.
Providing and Laying Solid cement concrete block masonry with M-5 Grade of 190/ 140 mm thick in super structure in cement mortar 1:4 (using crushed sand). The rate shall also including scafolding/ staging, drilling of holes (if any) for fixing of rebar by applying chemical or welding or as directed by EIC including Making the cut out opening in masonary for flush concealing DB/plug point/switch box enclosure including dismantling in floor or walls by cutting masonary and making good the damage to walls, painting, etc. existing surface including disposal of rubbish to the naerest dumping ground at a minimum distance of 50m away from the building. Complete all as per drawings and specifications and as directed by the Engineer-in-charge. Note:( Reinforcement will be paid under relevant item)
Providing and fixing TMT Steel Reinforcement bars of specified grades manufactured using virgin materials confirming to IS 1786 for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge(Steel supplied by contractor).
Providing and fixing of Hollow metal Two Hour fire rated doors(Single/ Double leaved) consisting of door frame and shutters and all hardware fittings as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specifications. The recommended fire doors shall have type test report from NABL cerified lab for minimum rating of 2 hours with vision panel. Deviation in specification and sheet thickness other than what is mentioned in the test certificates shall not be allowed. Proper label confirming the type of door and the hourly rating shall be mandatory. Door shall include fixing 4 nos heavy duty stainless steel 304 grade ball bearing, fire tested stainless steel butt hinges of size 100 x 75 x 3.00 mm (heavy weight) with suitable stainless steel screws, mortise / dead lock , a pair of 200 mm long stainless steel handles, 250 mm long stainless steel tower bolt / concealed tower bolt etc. frame hollow portion filled with PCC 1:2:4, necessary hold fast embedded in concrete, fixing in concrete with anchor fasteners. finished with Polyurethane painting of approved colour complete all as per drawings and specifications and as directed by the Engineer-in-charge
Providing and fixing fire rated Steel Rim Panic Exit Device of approved brand & quality in single leaf door upto 1000mm wide including all accessories etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge.
Supplying and fixing Rolling shutters as per ISI standards made out of required size of MS lathes 18 gauge interlocked together throughout entire length and jointed together at the end by end locks mounted on specially designed pipes shaft with brackets, side guides and arrangements for inside & outside locking with push and pull operation complete including the cost of providing and fixing necessary springs of required size and M. S top cover of required thickness for rolling shutters Rolling shutters (Laths Interlocked) gear operated type with handles including top hood 1.25mm mm thick complete all as per drawings and specifications and as directed by the Engineer-in-charge.
Extra over the cost of rolling shutters for providing and fixing motorized arrangements( with remote & manual operation) including designing, control panels, limit switches, required wiring and cables from panel to motor and required size of shaft etc all as per standard specifications including commissioning and testing complete all as per drawings and specifications and as directed by the Engineer-in-charge.(only power supply point will be provided)
Extra over the cost of rolling shutters for providing wicket gate of specified size in the M.S rolling shutters including fixing with fixing arrangements, hinges, locking arrangements, frames etc. complete all as per drawings and specifications and as directed by the Engineer-in-charge.
Providing 20 mm thick plastering using Ready mix external plastering compound for external faces of brickwork / concrete surfaces including water proofing compound @ 2% by weight of cemen, preparation of the surface, curing, cleaning scaffolding up to 10 metres height complete.all as per specifications including forming drip moulds wherever necessary,including Providing and fixing G.I. chicken mesh in the junctions of concrete & brick work / masonry (including cutting, fixing with nails in position before plastering) and complete all as per drawings and specifications and as directed by the Engineer-in-charge.
Extra for Plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof
Above 10 metres but up to a height of 13 metres
Above 13 metres but up to a height of 16 metres
Above 16 metres but up to a height of 19 metres
Above 19 metres but up to a height of 22 metres
Above 22 metres but up to a height of 25 metres
Above 25 metres but up to a height of 28 metres
Above 28 metres but up to a height of 31 metres
Above 31 metres but up to a height of 34 metres
Above 34 metres but up to a height of 37 metres
Providing U3 finish for RCC Surfaces rendering smooth top of the suspended floors ,landings and staircases (treads and risers), walls, slab soffits etc. including grinding / carborandum stone for repairing surface defects in areas where forms are removed, ridges at form joints, honey-combed areas, damage resulting from the stripping of forms and bolt holes including chipping / tooling of bulges and ridges, rubbing, cleaning, necessary scaffolding / staging etc. with C.M 1:2 (using Crushed sand) including a floating coat of neat cement and protecting the surface subsequent to cleaning complete all as per drawings and specifications and as directed by the Engineer-in-charge.
Supply and embedment of 14 SWG heavy duty hot dipped GI conduit pipe(25mm Dia) along with all accessories such as bends, junction box, socket, check nut, fish wire etc. including making threads, bends, removing burrs, connection of accessories, drawing of fish wire, laying in RCC slab, beam and wall, cutting & Laying in brick wall, etc. as required under the instruction of Engineer-in-incharge. Deep junction box of min 75mm deep or as required shall be provided.
Supply
Installation
Supply and erection of GI enclosure fabricated out of 2mm thick pre galvanised GI sheet steel with required cutting, welding, bending, stiffners as per drawings and embed in concrete or brick wall, cutting brick wall to suit size, etc as required under the instruction of Engineer-In-Charge.
Supply
Installation
Supply and embedment of copper earth plate/pad of size 40 mm wide x 6mm thick x 550 mm long having 10 nos. of 10 mm dia . Tapped hole for outgoing connections and 11 mm dia. Rod on back side for brazing of 2 nos. 95 sq. mm copper conductor including brazing, connection with suitable hardwares, mounting arrangement etc. as required. ( 95 sqmm conductor is not included in this item)
Supply and laying 14 SWG Cu-ETP grade bare solid tinned copper conductor concealed in concrete, RCC slab, including cutting, clamping, brazing, connection etc as per drawing or as per instructions by Engineer-InCharge
Supply
Installation
Concelaed/Surface Installation of 95 Sq.mm tinned stranded bare copper earthing conductor in Brick wall along with making of chasing, finishing of wall as per technical specification and instruction of engineer in charge. (Conductor to be provided as FIM by department)
Supply and installation of Heavy duty Class-C GI pipe to be laid in concrete slab/wall or brick wall for laying cables.
Supply of required material and making of exothermic braze joints of copper conductor with other conductor or copper earthing pad including removal of burrs and debris as per technical specification and instruction of engineer in charge.
SVJ INOVABUILD PRIVATE LIMITED (BID ID -3227136)
DIPAK S PIMPLE ENGINEERS AND CONTRACTORS (BID ID -3228574)
M/S DATTATRAY CONSTRUCTION (BID ID -3227866)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 9.20 MB
TenderFilePTC123.pdf
Tender Documents • 14.16 MB
TechnicalBidPTC123.xls
Additional Documents • 0.07 MB
BOQ_905567.xls
BOQ • 0.34 MB
BOQ.xls
BOQ • 0.34 MB
BOQ_2.xls
BOQ • 0.07 MB
Tenderdocument.pdf
Tender Documents • 14.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .