Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹33.9 L+₹7.0 L (25.8%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹36.7 L+₹9.7 L (35.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹40.4 L+₹13.4 L (49.6%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹40.5 L+₹13.5 L (50.1%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
4 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
REPAIR MAINTENACE OF LT ELECTRIC SUPPLY DISTRIBUTION PANELS LT UG CABLES AND ALLIED WORKS AT 512 ABW UNDER AGE EM II IN GE C KIRKEE
2021_MES_485761_1
8512/E8 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE CENTRAL KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹80,000
Yes
20 Dec 2021
2 Nov 2021
6 Dec 2021
2 Nov 2021
4 Dec 2021
17 Nov 2021
2 Nov 2021 - 16 Nov 2021
60 days
Amount
Material & Labour for disconnecting old unsv main switch any type and supply & fixing, connecting to existing cable with new MCCB, 4 pole, 63 Amps, 25 KA, including sheet metal enclosure duly powder coated fixed on existing angle iron stand with nuts, bolts etc complete all as specified and as directed by Engr-in-Charge. Make:- Legrand , Cat No:- 669716 or equivalent in Schneider/L&T as approved by GE.
All as per Item No 1.00 Above but MCCB, 4 pole, 100 Amps, 25 KA Make:- Legrand, Cat No:- 669718 or equivalent in Schneider/L&T as approved by GE.
All as per Item No 1.00 Above but MCCB, 4 pole, 125 Amps, 25 KA Make:- Legrand, Cat No:- 669719 or equivalent in Schneider/L&T as approved by GE.
All as per Item No 1.00 Above but MCCB, 4 pole, 160 Amps, 36 KA Make:- Legrand, Cat No:- 669070 or equivalent in Schneider/L&T as approved by GE.
All as per Item No 1.00 Above but MCCB, 4 pole, 200 Amps, 36 KA Make:- Legrand, Cat No:- 669071 or equivalent in Schneider/L&T as approved by GE.
All as per Item No 1.00 Above but MCCB, 4 pole, 250 Amps, 36 KA Make:- Legrand, Cat No: 669072 or equivalent in Schneider/L&T as approved by GE.
Supplying, fixing, jointing and testing heat shrinkable Straight through joint, with and including jointing materials and necessary earth work suitable for 1100 V , XLPE LT cable of size 25-50 sqmm , 3.5/4 core, complete all as specified and as directed by Engineer in Charge.
All as item no 7.00 above but cable size 70-120 Sqmm
All as item no 7.00 above but cable size 150-185 Sqmm
All as item no 7.00 above but cable size 240-300 Sqmm
Material and Labour for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed by Engineer in Charge.
Supply, Laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in old location in replacement as directed with and including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed by Engineer in charge of following size:-
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 Sqmm 3.5 core
185 Sqmm 3.5 core
300 Sqmm 3.5 core
400 Sqmm 3.5 core
Note for Item No 12: (i) During laying of cable, any damage to the existing services will be made serviceable without any extra cost within 24 hrs. (ii) contracor should visit the site before quoting the rate for understaniding the scope of work.
Supply and Fix 'light grade' galvanised iron tubing with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed by Engineer in Charge of the following bores :-
100 mm bore
50 mm bore
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6 Sqmm complete all as specified and as directed by Engineer in Charge.
Supply, installation, commissioning and testing of outdoor type Bus Bar LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar, fabricated in factory having modern fabrication, duly powder coated painted, dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The panel shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate, front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level including PCC work complete all as specified and as directed by Engineer in Charge. CPRI test report applicable (PTTA) as per IS should be provided by the manufacturer.
Supply, installation, commissioning and testing of outdoor type LT panel box, platform mounted, outdoor type, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar, pre-wired and fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-65 and general construction conforming to IS : 13947. The panel shall be made out of 3.00mm thick CRCA mild steel sheet duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level with and including PCC work complete all as specified and as directed by Engineer in Charge. CPRI test report applicable (PTTA) as per IS shall be provided by the manufacturer. The panel shall be comprising of the followings:-
Incommer:- MCCB 4 pole, 320A, 36kA, thermal & magnetic release - 01 Nos Make: Legrand (Cat No: 667654) or equivalent in Schneider/ LT as approved by GE.
Outgoing: (a) MCCB 4 pole 200A, 36kA, thermal & magnetic release - 02 Nos Make: Legrand (Cat No: 669071) or equivalent in Schneider/ LT as approved by GE.
(b) MCCB 4 pole 100A, 25kA, thermal & magnetic release - 02 Nos Make: Legrand (Cat No: 669718) or equivalent in Schneider/ LT as approved by GE.
(c) Digital Amp meter, volts meter, indicator set (RYB) - 01 Set
Note:- (i) The panel Box shall be designed in such a way that separate compartmet to each switch gear & Bus bar and adequate workable space is made available inside the compartments. (ii) Drawing should be approved by GE before manufacturing. (iii) Two stage inspection of manufacturing i.e. fabrication before powder coating & during swithgear installation, inspection/factory visit of Engg-in-Charge is compulsory to be arranged by contractor at no extra cost. (iv) Contractor shall visit the site to understand the scope of work before quoting the tender.
Supply, installation, commissioning and testing of outdoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar, pre-wired and fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-65 and general construction conforming to IS : 13947. The panel shall be made out of 3.00mm thick CRCA mild steel sheet duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level with and including PCC work. CPRI test report applicable (PTTA) as per IS should be provided by the manufacturer. The panel shall be comprising of the followings:-
Incommer:- MCCB 4 pole 400A, 36kA, thermal & magnetic release - 01 Nos Make: Legrand (Cat No: 667655) or equivalent in Schneider/ LT as approved by GE.
Outgoing: (a) MCCB 4 pole 250A, 36kA, thermal & magnetic release - 01 Nos Make: Legrand (Cat No: 669072) or equivalent in Schneider/ LT as approved by GE.
(b) MCCB 4 pole 160A, 36kA, thermal & magnetic release - 02 Nos Make: Legrand (Cat No: 669070) or equivalent in Schneider/ LT as approved by GE.
(c) MCCB 4 pole 63A, 25kA, thermal & magnetic release - 02 Nos Make: Legrand (Cat No: 669716) or equivalent in Schneider/ LT as approved by GE.
(d) Digital Amp meter, volts meter, indicator set (RYB) - 01 Set
Note :- (i) The panel Box shall be designed in such a way that saperate compartmet to each switch gear & Bus bar and adequate workable space is made available inside the compartments (ii) Drawing should be approved by GE before manufacturing. (iii) Two stage inspection of manufacturing i.e. fabrication before powder coating & during swithgear installation, inspection/factory visit of Engg-in-Charge is compulsory to be arranged by contractor at no extra cost. (iv). Contractor should visit the site to understand the scope of work before quoting the tender.
Supply, installation, commissioning and testing of Indoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar, pre-wired and fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-65 and general construction conforming to IS : 13947. The panel shall be made out of 3.00mm thick CRCA mild steel sheet duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level with and including PCC work complete all as specified and as directed by Engineer in Charge. CPRI test report applicable (PTTA) as per IS should be provided by the manufacturer. The panel shall be comprising of the followings:-
Incommer:- MCCB 4 pole 400A, 36kA, thermal & magnetic release - 01 Nos Make: Legrand (Cat No: 667655) or equivalent in Schneider/ LT as approved by GE.
Outgoing: (a) MCCB 4 pole 250A, 36kA, thermal & magnetic release - 01 Nos Make: Legrand (Cat No: 669072) or equivalent in Schneider/ LT as approved by GE.
(b) MCCB 4 pole 160A, 36kA, thermal & magnetic release - 06 Nos Make: Legrand (Cat No: 669070) or equivalent in Schneider/ LT as approved by GE.
(c) MCCB 4 pole 100A, 25kA, thermal & magnetic release - 02 Nos Make: Legrand (Cat No: 669718) or equivalent in Schneider/ LT as approved by GE.
(d) Digital Amp meter, volts meter, indicator set (RYB) - 01 Set
(Note : (i) The panel Box shall be designed in such a way that saperate compartmet to each switch gear & Bus bar and adequate workable space is made available inside the compartments (ii) Drawing should be approved by GE before manufacturing. (iii) Two stage inspection of manufacturing i.e. fabrication before powder coating & during swithgear installation, inspection/factory visit of Engg-in-Charge is compulsory to be arranged by contractor at no extra cost. (iv). Contractor should visit the site to understand the scope of work before quoting the tender.
Supply, installation, commissioning and testing of Indoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar, pre-wired and fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-65 and general construction conforming to IS : 13947. The panel shall be made out of 3.00mm thick CRCA mild steel sheet duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. CPRI test report applicable (PTTA) as per IS should be provided. The panel shall be comprising of the followings:-
Incommer:- MCCB 4 pole 400A, 36kA, thermal & magnetic release - 01 Nos Make: Legrand (Cat No: 667655) or equivalent in Schneider/ LT as approved by GE.
Outgoing: (a) MCCB 4 pole 250A, 36kA, thermal & magnetic release - 02 Nos Make: Legrand (Cat No: 669072) or equivalent in Schneider/ LT as approved by GE.
(b) MCCB 4 pole 200A, 36kA, thermal & magnetic release - 02 Nos Make: Legrand (Cat No: 669071) or equivalent in Schneider/ LT as approved by GE.
(c) MCCB 4 pole 160A, 36kA, thermal & magnetic release - 08 Nos Make: Legrand (Cat No: 669070) or equivalent in Schneider/ LT as approved by GE.
(d) Digital Amp meter, volts meter, indicator set (RYB) - 01 Set
Note : (i) The panel Box shall be designed in such a way that saperate compartmet to each switch gear & Bus bar and adequate workable space is made available inside the compartments (ii) Drawing should be approved by GE before manufacturing. (iii) Two stage inspection of manufacturing i.e. fabrication before powder coating & during swithgear installation, inspection/factory visit of Engg-in-Charge is compulsory to be arranged by contractor at no extra cost. (iv). Contractor should visit the site to understand the scope of work before quoting the tender.
Supply, installation, commissioning and testing of Indoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar, pre-wired and fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-65 and general construction conforming to IS : 13947. The panel shall be made out of 3.00mm thick CRCA mild steel sheet duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. CPRI test report applicable (PTTA) as per IS should be provided by the manufacturer. The panel shall be comprising of the followings:-
Incommer:- 1600A FP ACB (50kA), 415 Volts with microprocessor based protection unit with draw out version, incl all Protection with LCD touch screen multicolour display with battery backup all as specified and as directed by Engr-in-Charge. Make - Legrand/ L&T/Schneider as approved by GE.
Outgoing: (a) MCCB 4 pole 400A, 36kA, thermal & magnetic release - 01 Nos Make: Legrand (Cat No: 667655) or equivalent in Schneider/ LT as approved by GE.
(b) MCCB 4 pole 160A, 36kA, thermal & magnetic release - 02 Nos Make: Legrand (Cat No: 669070) or equivalent in Schneider/ LT as approved by GE.
(c) MCCB 4 pole 100A, 25kA, thermal & magnetic release - 15 Nos Make: Legrand (Cat No: 669718) or equivalent in Schneider/ LT as approved by GE.
(d) Digital multifunctional meter with suitable CT and indicator set (RYB) - 01 Set
Note:- (i) The ACB panel Box shall be designed in such a way that saperate compartmet to each switch gear & Bus bar and adequate workable space is made available inside the compartments. (ii) Drawing should be approved by GE before manufacturing. (iii) Two stage inspection of manufacturing i.e. fabrication before powder coating & during swithgear installation, inspection/factory visit of Engg-in-Charge is compulsory to be arranged by contractor at no extra cost. (iv). Contractor should visit the site to understand the scope of work before quoting the tender.
Material and Labour earthing GI Strip complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR2020-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and as directed by Engineer in Charge. NOTE:- The unit rate quoted by contractor includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
Material and Labour for connecting galvanised iron ( GI ) strip 32 X 6 mm, in replacement to the existing earthing to eqpts complete all as specified and as directed by Engineer in Charge.
TULAJA ENTERPRISES
M/S. OM ENTERPRISES
metro electrical services
M/S. Niksun Electro-Infra Private Limited
T.H.ASSOCIATES
PAMS ENTERPRISES
JP ENTERPRISES
AN-ICON Engineering Technologies And Infrastructure Developments Pvt. Ltd
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .