| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC 00 BACHUAPAR RAJESULTANPUR ALAPUR AMBEDKAR NAGAR UTTAR PRADESH 224176 | AMBEDKAR NAGAR | UTTAR PRADESH | 224176 | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.2 L+₹4.4 L (15.7%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | SANJEEV ENTERPRISES L2 | SB ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00Filtration of transformer oil of transformers / FRMUs of following capacity installed at various locations to achieve di-electric strength not less than 60 KV at 2.5mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as specified and as directed. | |||||
| 1.01 | 630 KVA | 1,000 | Litre | 8 ₹8,000 Lowest | 11.99 ₹11,990 |
| 1.02 | 2000 KVA 02 Nos | 1,000 | Litre | 8 ₹8,000 Lowest | 11.99 ₹11,990 |
| 2.00 | Supply and topping up of transformer oil with di-electric strength not less than 60 KV in to the conservator tank/ body tank of the transformer/ OCB/ RMUs etc. at various locations complete all as specified and as directed. | 1,100 | Litre | 140 ₹1,54,000 | 109 ₹1,19,900 Lowest |
| 3.00 | M & L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate), "mild steel angle iron frame" made out of MS angle iron of size 40x 40 x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No 3" and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and as directed. | 4 | Each Job | 3,500 ₹14,000 Lowest | 5,009 ₹20,036 |
| 4.00 | Dismantling existing earthing and providing new Chemical Earthing complete with copper earth plate of size 90x60cmx5mm & copper earth strip 50x6mm with 50 KG and Backfill Compound, buried directly in ground [Rocky Soil] with earth pit not less than 2.25 m deep below ground level with top edge of Plate not less than 1.50 m below normal ground level connected to existing Copper Earth Strip by means of Stainless Steel bolts, nuts, check nuts and washers all as per IS – 3043 including testing on completion complete all as specified and as directed. The earth resistance shall be measured using fall of potential method as per Para 37 of IS – 3043 & combined resistance should be less than 1 Ohms. Note: The unit rate quoted shall be deemed to include for PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS handle 12mm dia, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed. | 3 | Each Job | 40,000 ₹1,20,000 | 39,999 ₹1,19,997 Lowest |
| 5.00M & L for preparation of old painted surfaces of transformers with coarse cloth/ brush and painting throughout externally on exposed surfaces with two coats of smoke grey colour synthetic enamel paint including complete including one coat of white wash for base foundation complete all as specified and as directed. for the following capacity in-door/ out-door type transformer:- | |||||
| 5.01 | 630 KVA | 2 | Each | 5,000 ₹10,000 Lowest | 6,999 ₹13,998 |
| 5.02 | 2000 KVA | 2 | Each | 5,000 ₹10,000 Lowest | 9,999 ₹19,998 |
| 6.00M & L for replacement of Silica gel breather assembly complete with breather unit and silica gel including connecting with proper necessary gaskets if necessary, including removing the unserviceable breather assembly complete all as specified and as directed. | |||||
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
6 Oct 2025, 6:00 pmClosed
CWE
HQ CWE No 2 Delhi Cantt
REPAIR MAINT OF VARIOUS HT ELECTRIC SUB STATIONS (TRANSFORMERS, VCBS/ACB BREAKERS) AND OTHER ALLIED WORKS AT DPL COMPLEX AND RRC PATPARGANJ, ARC MAHIPALPUR, GHITORNI AREA UNDER GE (SW) NEW DELHI-03
2025_MES_713595_2
CWE/SW/TOKEN-01/2025-26
Limited
Electrical and Maintenance Works
Item Rate
180 days
RESTRICTED AREA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE SOUTH WEST NEW DELHI
₹74,000
11 Nov 2025
23 Sept 2025
7 Oct 2025
23 Sept 2025
6 Oct 2025
30 Sept 2025
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .