Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-AOC | L1 | Accepted-AOC Accept due to lower rates | |
| 2 | L2₹3.4 L+₹4,116.05 (1.21%)Rejected-AOC | L2 | Rejected-AOC Reject due to higher rates | |
| 3 | L3₹3.6 L+₹19,639.95 (5.77%)Rejected-AOC | L3 | Rejected-AOC Reject due to higher rates | |
| 4 | L4₹3.6 L+₹23,452.96 (6.89%)Rejected-AOC DELHI ALWAR ROAD SADDIQ NAGAR DISTRICT NUH 122107 | NUH | HARYANA | 122107 | L4 | Rejected-AOC Reject due to higher rates | |
| 5 | L5₹3.8 L+₹37,048.05 (10.9%)Rejected-AOC | L5 | Rejected-AOC Reject due to higher rates |
Tender Value
₹3.8 L
EMD Value
₹8,000
Closing Date
28 May 2020, 5:00 pmClosed
Executive Engineer
Executive Engineer, Provincial Division, PWD (BNR) Br., Nuh
S/R for Training Hall and Construction of underground Water Tank in campus of Animal Husbandry and Dairy Complex at Nuh in Nuh Distt.
2020_HRY_128506_1
PWD/Nuh/Water/Tank/AHD
Open Tender
Civil Works
Works
60 days
Nuh
As per bid document
3 documents required · 3 mandatory
₹500
Yes
Public Work (B and R) Department
₹8,000
Yes
Executive Engineer
15 Jun 2020
14 May 2020
29 May 2020
14 May 2020
28 May 2020
14 May 2020
21 May 2020
Amount
Earth work in excavation in foundations, trenches etc. in all kinds of soil, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry in 15 cm layers with compaction, including disposal of all surplus soil as directed within a lead of 30 Mtrs. (HSR 6.6)
Cement concrete 1:4:8 with stone aggregate 40 mm nominal size in foundation & plinth. (HSR 10.39)
Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centering and shuttering, laid in position, complete in all respect. (HSR. 10.82 + 10.95 (a))
Cement concrete 1:1½:3 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (Straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centering and shuttering, laid in position complete in all respects. (HSR. 10.86 + 10.95 (a))
Cement concrete 1:1½:3 with stone aggregate 20mm nominal size for reinforced concrete work in footing, strips, foundation, rafts, pedestal and approach slabs of bridges etc. but excluding steel reinforcement and including centering and shuttering, laid in position, complete in all respects. (for work upto 1.5 Mtrs. below ground level). (HSR. 10.90 + 10.95 (a))
12mm thick cement plaster on walls (1:6). (HSR 15.7)
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. Painting on wooden surfaces etc. (HSR 16.1)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (Note:- First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.2)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.3)
Applying priming coat with metal primer on new steel or iron work including preparation of surface. Painting on metallic Surfaces etc. (Note: First quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.9)
Painting two coats excluding priming coat with ready mixed paint for metallic surface in all shades on new steel or iron work. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.17)
Cost of aluminum fitting complete for doors and windows, such as tower bolt, handles etc. screws for these fittings (excluding sliding bolt) complete. Single leaf shutter (HSR 17.72 (a))
Supplying and fixing hydraulic door closer, I.S.I. mark, with necessary screws, etc., complete I.S.I. designation No.II (size of door 701 mm to 850 mm) (HSR 17.82 (b))
Providing & Fixing sliding bolt with nuts and screws, etc complete aluminum (size 300 mm x 16mm ) (HSR 17.83 (b))
Factory manufactured panelled door or glazed window, shutters of commercial hard wood, such as hollock, champ, chikrassy & chaplash etc. (non-coniferous timber other than teak, conforming to I.S specification no. 1003, Kiln-seasoned) with 100 mm wide vertical styles, 150 mm wide lock rail, 200 mm wide bottom rail and 100 mm wide other rails, with panels of 15 mm thick, tongued and grooved of commercial hard wood and including cost of iron hinges, screws, chocks/cleats, stops, nails etc. complete, fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position) - (a) 30 mm thick. (HSR. 17.90(a)) - Note I under 17.18
Factory manufactured wire gauze door and window shutters of commercial hard wood such as hollock, champ, chikrassy annd chaplash, etc. (non coniferous timber other teak conforming to I.S specification no. 1003, kiln seasoned) with 100 mm wide vertical styles, 150 mm wide lock rail 200 mm wide bottom rail, and wire gauze of 140 G or 120 G designation including cost of iron hinges, screws, chock/cleats, stops nails etc. complete fixed in position (excluding the cost of any fittings, other than specified above, but including labour for fixing the same in position) (i) 30 mm thick (HSR 17.92 (i) - Note I under 17.18
Factory manufactured Solid Flush Door Shutter, with block board core as per I.S. No. 1659-1969 bonded with water proof type phenol formaldehyde synthetic resin, hot pressed, conforming to I.S. 2202 part I and II, fixed in position, including iron hinges, screws, chocks/cleats and stops etc., (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position. (Note:- reputed make such as Duro, Green, Kitply will be used as approved by Engineer-in-charge). HSR 17.93 (a) - Note 1 under 17.18) Note:- The Agency to whom the work is allotted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. (a) 35 mm thick.
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, grating frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12)
Fe-500 EQR TMT steel bars for RCC works, where not including in the complete rate of RCC including bending, binding and placing in position complete. (NS). Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. From the length so measured, the weight of reinforcement shall be calculated in tones on the basis of IS:1732.Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
Supplying and fixing glass panes including special metal sash putty of approved make (b) Glass panes 4 mm thick, exceeding 40 sq.m areas. MODI, SAINTGOBAIN (HSR 18.30 B)
Constructing brick masonry inspection chamber sizes as given below upto 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent limer mortar 2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2;4 slab 100 mm thick./C.C. topping 50 mm thick with 455 mm x 455 mm 610 mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (HSR 29.84). (a) Size 450 mm x 450 mm
Extra for over 0.30 metre depth of inspection chamber. (a) 450 x 450 mm. (HSR 29.85)
Providing and fixing SFRC manhole covers and frames markd with IS: 12592 including setting the same to correct lines and levels in 1:2 cement sand mortar over manhole including carriage loading, unloading stacking, handling, re-handling etc. complete in all respect to the satisfaction of engineer-in-charge. (c) TYPE: Extra Heavy Duty Set (MD-10) 560 mm Clear Opening). (HSR 29.94)
The Rahul Khan Coop LnC Society Ltd.
Sh. Maqsood Ahmed
M.K. Construction Co.
MOHD.SABIR CONSTRUCTION
Ikbal, Contractor
The Mubeen Coop. LNC Society Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .